PCR/Sequencing/Nucleic Acid Analysis
Filter
Showing 61–90 of 399 results
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 384-well |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | Up to 6 independent excitation/emission channels |
| Light Source | 7 high-intensity, long-life LEDs (UV–NIR spectrum) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Scanning Method | 16-channel fiber-optic simultaneous detection |
| Detection Sensitivity | Single-copy DNA template resolution |
| Dynamic Range | 10 logs |
| Gradient Function | 24-column linear temperature gradient |
| Thermal Block | Peltier-based, corrosion-resistant |
| Lid Temperature | Up to 110 °C with auto-adjusting pressure (max. 30 kg/plate) |
| Software | qPCR analysis suite compliant with MIQE guidelines |
| Connectivity | USB, LIMS-compatible |
| Noise Level | ≤60 dB(A) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | 4–6 configurable |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET-mismatched and protein melting-specific configurations |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning system |
| Dynamic Range | 10 orders of magnitude |
| Reaction Volume | 2–30 µL |
| Heat Lid Temperature Range | 30–110 °C with auto-adjusting contact pressure up to 30 kg/plate |
| Software | Free lifetime-upgradable analysis suite supporting absolute quantification, dual-standard-curve relative quantification, ddCt with amplification efficiency correction, melting curve analysis, SNP/allele discrimination, endpoint analysis, and efficiency calculation |
| Acoustic Noise Level | ≤45 dB(A) |
| Brand | analytikjena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | qTOWER384G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Configuration | 6-channel excitation/emission system (field-upgradable from 1–6 channels) |
| Filter Sets | 12 interchangeable excitation/emission filter combinations, including FRET-optimized and protein melting-specific configurations |
| Light Source | RGBW solid-state LEDs (blue, green, red, white) with uniform spectral intensity, zero thermal emission, >50,000 h lifetime |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning (16 wells simultaneously), ROX-free operation with optional passive reference correction |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 logs (10¹–10¹¹ copies) |
| Recommended Reaction Volume | 2–30 µL |
| Thermal Gradient | 24-column linear temperature gradient (enables precise annealing optimization) |
| Thermal Block | Peltier-based, corrosion-resistant, high-thermal-conductivity alloy |
| Heat Lid | 110 °C maximum, auto-adjusting pressure (up to 30 kg/plate), height compensation |
| Software | qPCRsoft — quantitative analysis, dual standard curve, ΔΔCt with amplification efficiency modeling, melting curve analysis, SNP/allelic discrimination, endpoint genotyping, efficiency calculation, MIQE-compliant reporting, LIMS integration (via USB), GLP/GMP-ready audit trail (optional configuration), unlimited installations, lifetime free updates |
| Acoustic Noise Level | ≤45 dB(A) |
| Compliance | Designed and validated per ISO 13485 principles |
| Brand | analytikjena |
|---|---|
| Origin | Shanghai, China |
| Model | qTOWER384G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Heating Rate | 4 °C/s |
| Optical Channels | Up to 6 independent detection channels |
| Excitation/Detection Filter Sets | 12 configurable combinations including FRET-mismatched and protein melting-specific sets |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 logs |
| Recommended Reaction Volume | 2–30 µL |
| Thermal Gradient | 24-column linear gradient |
| Thermal Block | Peltier-based, corrosion-resistant |
| Lid Temperature | Up to 110 °C with auto-adjusting pressure (up to 30 kg/plate) |
| Noise Level | ≤45 dB(A) |
| Connectivity | USB |
| Software | MIQE-compliant reporting, unlimited free installation & lifetime updates |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.15 °C |
| Linear Gradient Range | 12-column independent gradient |
| Detection Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 orders of magnitude |
| Optical Channels | Up to 6 channels (configurable 1–6) |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET and protein melting-optimized configurations |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | Channel-type Photomultiplier Tube (CPMT) |
| Scanning Method | 8-channel fiber-optic simultaneous detection |
| Scan Time | 6 s for full 96-well plate (6-channel mode) |
| Cycle Time | ≤45 min for 40 cycles |
| Thermal Block | Gold-plated pure silver Peltier module |
| Heat Lid | 110 °C max, auto-pressure adjustment up to 10 kg/plate |
| Reaction Volume | 10–80 µL |
| Noise Level | ≤45 dB(A) |
| Connectivity | USB, RS232, Ethernet |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~30 kg |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH & Co. KG |
| Model | SpeedCycler2 |
| Module Options | 96-well LPR (20 µL), 96-well SPR (0.2 mL), 96-well SP (0.2 mL) |
| Max Heating Rate | 15 °C/s (LPR module) |
| Max Cooling Rate | 10 °C/s (LPR module) |
| Temperature Range | 4–105 °C |
| Temperature Accuracy | < ±0.2 °C at 72 °C |
| Temperature Uniformity | < ±0.3 °C at 72 °C |
| Heat Lid Temp | up to 120 °C |
| Control Interface | HID-Pro 320 5.7" color touchscreen or PC via Windows CE-based software |
| Program Storage | 500 protocols on device |
| Dimensions (W×H×D) | 280 × 290 × 250 mm |
| Weight | 12 kg |
| Brand | Antylia/Cole-Parmer |
|---|---|
| Model | HI-200D |
| Temperature Stability (in tube) | ±0.1°C |
| Rotational Speed Range | 0–20 rpm |
| Oscillation Frequency | 5–20 or 15–60 opm |
| Max Operating Temperature | 100°C |
| Min Operating Temperature | Ambient +10°C |
| Temperature Accuracy | ±0.3°C |
| Temperature Uniformity (in tube) | ±0.5°C |
| Chamber Uniformity | ±1.5°C |
| Temp Set Resolution | 0.1°C |
| Dimensions (L×W×H) | 285 × 385 × 555 mm |
| Voltage | 230 V, 50–60 Hz |
| Power Consumption | 750 W |
| Net Weight | 24 kg |
| Brand | Anxuyuan |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AxiLona AXP-100 |
| Instrument Type | Third-Generation Sequencer |
| Medical Device Classification | Non-Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 1–100 kbp |
| Sample Input Requirement | ≥100 ng |
| Throughput | ≤100 Gb per run |
| Base Call Quality | >80% of bases ≥ Q20 |
| Raw Read Accuracy | 99.2% |
| Brand | Anxuyuan |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | AxiLona EL-100 |
| Instrument Category | Nucleic Acid Hybridization Analyzer |
| Pricing | USD 84,000 (FOB Guangdong) |
| Brand | Anxuyuan |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AxiLona FL-100 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 4 samples per run |
| Temperature Control Accuracy | ≤ ±0.5°C |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Models | Kingwell 96, Kingwell 96DW, Kingwell 384 |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 96-well or 384-well format |
| Maximum Heating Rate | 7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Heating Block Material | Gold-Plated Aluminum Alloy |
| Power Output | Up to 750 W |
| Display | 10.1-inch Capacitive Touchscreen |
| Control Interface | On-device GUI + Remote Web-Based Management (HTTP/HTTPS) |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | Pangaea Super 8 Portable |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM/VIC/ROX/Cy5) |
| Reaction Volume | 10–50 µL |
| Optical Detection System | Waveguide-Coupled CMOS Imaging System |
| Dimensions (L×W×H) | 280 × 200 × 230 mm |
| Sample Loading | Motorized Auto-Loading Tray |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Connectivity | RJ45 Ethernet port |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | Pangaea Super 8 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM, VIC, ROX, CY5) |
| Reaction Volume | 10–50 µL |
| Optical Detection System | Waveguide-CMOS Integrated Optical Module |
| Dimensions (L×W×H) | 280 × 200 × 230 mm |
| Sample Loading | Motorized Auto-Loading Carousel |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Connectivity | RJ45 Ethernet port |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Pangaea Super8 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM/VIC/ROX/Cy5) |
| Reaction Volume | 10–50 µL |
| Optical System | Waveguide-CMOS Integrated Optical Detection |
| Dimensions | 280 × 200 × 230 mm (L×W×H) |
| Sample Loading | Motorized Auto-Loading Tray |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Brand | Applied Biosystems |
|---|---|
| Model | 2720 |
| Sample Capacity | 96-well |
| Heating Rate | 2.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.5 °C |
| Operating Temperature Range | 4.0–99.9 °C |
| Heat Lid Temperature | 105 °C |
| Memory Capacity | 100 protocols |
| Tm Calculation | Built-in |
| Power Failure Recovery | Auto-resume |
| NIST-Traceable Calibration | Yes |
| Diagnostic Self-Test | Integrated |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | 2720 |
| Sample Block | Aluminum 0.2 mL 96-well |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.5 °C (35–100 °C) |
| Dimensions (L×W×H) | 36 × 21 × 22 cm |
| Part Number | 4359659 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 3730xl |
| Instrument Type | First-Generation Capillary Electrophoresis DNA Sequencer |
| Read Length Range | 400–600 bp |
| Throughput | 768–3,936 reads/day |
| Detection Accuracy | 99.99% |
| Reproducibility | 90% |
| Run Frequency | 8–72 runs/day |
| Capillary Array Compatibility | 48- and 96-capillary formats |
| Laser Source | 505 nm solid-state laser |
| Temperature Control Range | 18–70 °C |
| Polymer System | POP-7™ polymer |
| Dye Capacity | Up to 6-color detection |
| Unattended Operation | Up to 48 hours |
| Integrated Barcode Reader | Yes |
| Onboard Plate Piercing | Yes |
| Automated Base Calling & Quality Value (QV) Scoring | Yes |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7300 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Reaction Volume | 25–100 µL |
| Detection Channels | 4-color fluorescence detection |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7500 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 48-well formats |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Model | 9700 Series |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 60-well, Dual 96-well, Dual 384-well |
| Ramp Rate | 5 °C/s |
| Temperature Accuracy | ±0.25 °C |
| Well-to-Well Uniformity | ±0.5 °C (30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Model | GeneAmp® 9700 |
| Origin | USA |
| Temperature Accuracy | ±0.25°C (35–100°C) |
| Temperature Range | 4–99°C |
| Ramp Rate | 3.5°C/sec (55–95°C) |
| Block Uniformity | ±0.5°C (35–100°C, 30 sec hold) |
| Heat Lid Temperature | 105°C |
| Display Resolution | 0.1°C (computed sample temperature) |
| Dimensions | 40.6 × 30 × 26 cm |
| Weight | 12.7 kg |
| Sample Formats | Interchangeable blocks — 60-well (0.5 mL), 96-well (0.2 mL), dual 96-well, dual 384-well |
| Software | GeneAmp 9700 Network Software (multi-instrument control) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ProFlex 2×384-well PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 384-well plates |
| Ramp Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (20 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |