Petroleum Specialized Analytical Instruments
Filter
Showing 391–420 of 439 results
| Brand | TANAKA (Japan) |
|---|---|
| Origin | Japan |
| Model | AAP-6 |
| Standards Compliance | ASTM D611, ISO 2977, GB/T 262 |
| Temperature Range | Ambient to 160 °C |
| Heating Rate | 10 °C/min (up to 10 °C below expected aniline point), then 2 °C/min |
| Safety Cutoffs | Auto-stop at +10 °C above expected aniline point or at 170 °C (whichever occurs first) |
| Sample Handling | Modular dual-section test vessel (removable lower section for solid/semi-solid sampling and weighing) |
| Cleaning | In-situ tube cleaning without disassembly |
| Display Interface | Color-coded status indicators (standby / active test / completion) |
| Dimensions | Compact integrated footprint |
| Control System | Embedded microprocessor with repeat-test automation and no sample replacement required between runs |
| Cooling Requirement | External cooling bath or chilled vessel mandatory for ambient temperatures <20 °C |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ABL-8 |
| Test Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Applicable Standards | GB/T 21789, IP 170, ISO 13736, ISO 1516, ISO 1523 |
| Temperature Range | −30 °C to +80 °C |
| Ignition System | Dual-mode (Gas Flame & Electric Spark) |
| Repeatability | High |
| Cooling Method | Peltier-based Semiconductor Cooling |
| Display | 5.7-inch Color LCD |
| Data Storage Capacity | 200 Test Records |
| Atmospheric Pressure Compensation | Integrated Barometric Sensor |
| Safety Features | Auto Fire Suppression, Fault Diagnostics, Wind Shield Enclosure |
| Compliance Support | ASTM D3278, ISO/IEC 17025 Traceability Framework, GLP Audit Trail Ready |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACO-100 |
| Test Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ISO 2592, ASTM D92, IP 36 |
| Ignition Source | Electric or Gas Pilot Flame |
| Temperature Range | Ambient to 400 °C |
| Data Storage Capacity | 200 test records |
| Interface Options | USB, RS-232 |
| Optional Accessories | Thermal Printer, USB Keyboard, USB Flash Drive |
| Security | Password-protected test program |
| Safety Features | Auto-ignition detection, auto-extinguishing system (activated upon flash point confirmation or sustained flame ≥5 s) |
| Brand | Tanaka Scientific Instruments |
|---|---|
| Origin | Japan |
| Model | ACR-6 |
| Heating Power | 1.3 kW |
| Ignition System | Pilot Flame with Manual Lighting of Pilot Tube |
| Cooling Method | Forced Air Cooling via Fan |
| Temperature Monitoring | Thermocouple-Based Flame Detection |
| Control System | Electronic Time Relay |
| Power Supply | 100/220 V AC, 50/60 Hz, 1.4 kW |
| Compliance | ASTM D189, IP 13, GB/T 268 |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ACR-M3 |
| Standards Compliance | ISO 10370, ASTM D4530, GB/T 17144 |
| Gas Flow Control | Auto-switching between 150 mL/min and 600 mL/min |
| Sample Capacity | 6 × large crucibles (5.0 g each) or 12 × small/medium crucibles (0.15–3.0 g each) |
| Heating Temperature | 500 °C ± 2 °C under inert gas atmosphere |
| Residue Weighing Resolution | 0.1 mg (requires external analytical balance) |
| Condensate Collection | Integrated high-temp resistant, explosion-proof condensate bottle |
| Front-panel Float Flowmeter | Visual flow verification and calibration support |
| Automation Level | Fully automated thermal ramping, dwell, cooling, and end-of-test audio alert (10 s) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AD-7 |
| Temperature Range | 0–450 °C |
| Condenser & Receiving Chamber Cooling | Peltier-based with internal recirculating coolant |
| Temperature Resolution | 0.1 °C |
| Condenser Temp Control Range | 0–69.9 °C (±0.2 °C accuracy) |
| Receiving Chamber Temp Control Range | 0–50 °C (±0.05 °C accuracy) |
| Distillate Rate Control | 2–10 mL/min (PID-regulated, factory default 4.5 mL/min) |
| Initial Boiling Point (IBP) Detection | Infrared photoelectric sensor |
| Dry Point Detection | Manual visual or optional automatic sensor |
| Heating System | 24 V/600 W vortex-type heater with forced-air cooling |
| Safety Systems | Flame detection sensor, automatic power cutoff, integrated fire suppressant discharge, flask support misalignment lockout, sensor fault monitoring |
| Data Storage | 5,000 test records |
| Test Method Presets | 200 programmable modes |
| Interfaces | RS-232C, Ethernet (for TDAS/LIMS), USB |
| Display | 10.4″ capacitive touchscreen LCD |
| Atmospheric Pressure Compensation | Automatic or manual input |
| Compliance | ASTM D86, ASTM D850, ASTM D1078, GB/T 6536 |
| Software | TDAS (Test Data Acquisition System) with curve export, remote operation, and printer output (thermal paper) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | AFP-102 |
| Standards Compliance | ASTM D6371, IP 309, EN 116, JIS K2288, SH/T 0248 |
| Cooling Method | Integrated Peltier thermoelectric module (no formaldehyde or external chiller required) |
| Temperature Range | Ambient to –60 °C |
| Temperature Resolution | 0.1 °C |
| Cooling Modes | Linear ramp and stepwise (isothermal) cooling |
| Detection Principle | Dual-point optical meniscus tracking via LED-photodiode system with dedicated mechanical mounting bracket |
| Sample Compatibility | Diesel fuels, heating oils, biodiesel blends, and other middle distillates |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | APM-100 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Applicable Standards | ASTM D93, GB/T 261, ISO 2719 |
| Ignition Source | Dual-mode (Gas Flame & Electric Spark) |
| Temperature Range | Ambient to 370 °C |
| Data Storage Capacity | 200 test records |
| Interface | USB (for keyboard, flash drive, and LIMS export) |
| Security | Password-protected test program |
| Safety Features | Integrated thermal cutoff, flame detection interlock, and automatic lid closure |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASC-8C |
| Test Method | Closed-Cup Equilibrium Method |
| Operating Mode | Fully Automatic |
| Applicable Standards | ISO 3679, ISO 3680, ASTM D3278, ASTM D7236, IP 534 |
| Temperature Range | −30 °C to +100 °C |
| Ignition Source | Dual-mode (electric spark or gas flame) |
| Repeatability | High |
| Atmospheric Pressure Compensation | Integrated barometric sensor |
| Data Storage Capacity | 200 test records |
| Output Options | Thermal printer, USB export, LIMS integration |
| Security | Password-protected user interface |
| Compliance | Designed for GLP-compliant laboratories and routine QC environments |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ASP-6 |
| Measurement Method | Ring-and-Ball (Dual-Sample) |
| Temperature Range | Ambient to 200 °C |
| Display | 5.7-inch LCD, 0.1 °C resolution |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Interface | RS-232C serial port |
| Power Supply | AC 220 V, 50/60 Hz, 12 A |
| Dimensions (W×D×H) | 230 × 440 × 420 mm |
| Weight | Approx. 14 kg |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | AVP-30D2 |
| Test Range | 0–196 kPa (0–2.0 kgf/cm²) |
| Bomb Dimensions | 2/3 standard length, 1/3 standard volume |
| Pressure Sensor | Integrated semiconductor transducer |
| Display | 180 mm × 100 mm LCD |
| Oscillation | Lever-driven, ±15° tilt, 6 s cycle |
| Water Bath | Stainless steel, ~35 mL capacity, PID temperature control with motorized circulation |
| Power Supply | AC 220 V, 50/60 Hz, 15 A |
| Dimensions (W×D×H) | 400 × 600 × 740 mm |
| Weight | ~45 kg (empty bath) |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | LF-1 |
| Standards Compliance | GB/T 12579–1990, ASTM D892–84, JIS K2518–1991 |
| Temperature Control | Dual-bath PID system (24 °C and 93.5 °C) |
| Bath Volume | Ø300 × 460 mm each |
| Temperature Stability | ±0.2 °C |
| Heating Power | 600 W (24 °C bath), 2 × 1000 W (93.5 °C bath) |
| Cooling Input Power | 600 W |
| Working Medium | Distilled water |
| Stirring Motor Power | 25 W |
| Air Pump Power | 6 W |
| Gas Diffuser | Ø25.4 mm, pore size <80 µm, air permeability 3000–6000 mL/min |
| Graduated Cylinder | 1000 mL |
| Air Flow Rate | 94 ± 5 mL/min |
| Timer Resolution | 1 s |
| Power Supply | AC 220 V, 50 Hz |
| Total Rated Power | 3.3 kW |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | MPC-6 |
| Test Method | ASTM D6749 (Air-Pressure Method), ASTM D97, ISO 3016 |
| Sample Volume | 4.5 mL |
| Temperature Interval | 1 °C or 2 °C |
| Repeatability | Pour Point ±1 °C (1 °C interval) / ±3 °C (3 °C interval) |
| Cooling Source | Integrated Peltier Module |
| Compliance | ASTM, ISO, GLP-ready architecture |
| Data Output | Auto-generated report with timestamped test logs |
| Brand | Tanaka |
|---|---|
| Origin | Japan |
| Model | SDL-2 |
| Standards Compliance | GB/T 7305-1987, ISO 6614:1983, ASTM D1401-1967 |
| Temperature Range | Ambient to 95 °C |
| Number of Test Stations | 5 |
| Cylinder Dimensions | Φ32 mm × 225 mm |
| Bath Dimensions | Φ300 mm × 300 mm (hardened glass) |
| Heating Power | 1.5 kW |
| Bath Stirrer Motor | AC 220 V, 25 W |
| Sample Agitator Motor | DC 24 V, 80 W |
| Timer Channels | 5 independent digital timers |
| Power Supply | AC 220 V, 50 Hz, 7.5 A |
| Control Unit Dimensions | 360 mm (W) × 400 mm (D) × 130 mm (H) |
| Test Chamber Dimensions | Φ360 mm × 590 mm (D × H) |
| Brand | TANAKA |
|---|---|
| Origin | Japan |
| Model | ST1011 |
| Temperature Range | Ambient to 130 °C |
| Temperature Stability | ±0.2 °C |
| Number of Test Positions | 6 |
| Heating Power | 2 kW |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 260 × 450 × 455 mm |
| Weight | 20 kg |
| Construction | Full stainless-steel housing |
| Compliance | ASTM D130, IP 154, ISO 2160, GB/T 5096 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | NOACK S2 |
| Price | Upon Request |
| Category | Laboratory Instrument |
| Test Parameter | Evaporation Loss of Lubricating Oils |
| Compliance Standard | ASTM D5800 |
| Dimensions (W×D×H) | 55 × 40 × 33 cm |
| Weight | 33.85 kg |
| Voltage | 220 V |
| Frequency | 50/60 Hz |
| Heating Method | Solid-State Metal Heater (Wood’s Metal-Free) |
| Vacuum System | Integrated Vacuum Pump with Automatic Control |
| Vacuum Level | 20 mm H₂O |
| Test Temperature | 250 °C (±0.1 °C accuracy) |
| Test Duration | 60 min |
| Safety Features | Over-Temperature Protection, Heat-Shield Enclosure |
| Certification | CE |
| Data Output | RS232 Serial Interface for Printer |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantum |
| Pricing | Upon Request |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SBT DC-II |
| Pricing | Upon Request |
| Dimensions (W×D×H) | 32 × 51 × 74 cm |
| Weight | ~36.3 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Cooling Range | +90 °C to –45 °C (±0.1 °C stability) |
| Max. Cooling Rate | 60 °C/h |
| Heating Capability | Up to 90 °C |
| Sample Capacity | 2 simultaneous tests |
| Control | Single PC can manage up to 4 units |
| Safety Certifications | CE compliant |
| Transport Dimensions | ~81 × 76 × 104 cm |
| Transport Weight | ~125 kg |
| Compliant Standards | ASTM D5133, ASTM D7110, ILSAC GF-2 through GF-6 (A&B), API SL/SM/SN, GB 11121, SH/T 0732, JPI-5S-56-99 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV CDT |
| Product Type | Laboratory Instrument |
| Compliance Standards | ASTM D8544, SAE J3200 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV WCT |
| Product Type | Laboratory Instrument |
| Compliance | SAE J3200 (in development), ASTM method under preparation |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBR |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS2100E-F / TBS3000 |
| Price | Upon Request |
| Dimensions (Viscometer) | 18 × 30.5 × 35.5 cm |
| Dimensions (Control Unit) | 46 × 46 × 15 cm |
| Dimensions (Auto-sampler, optional) | 46 × 51 × 61 cm |
| Weight (Viscometer) | 15.5 kg |
| Weight (Control Unit) | 9 kg |
| Weight (Auto-sampler) | 25.4 kg |
| Voltage | 220–240 V AC |
| Frequency | 50/60 Hz |
| Sample Volume | 50 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Temperature Range | 40 °C to 200 °C (±0.1 °C stability) |
| Shear Rate Range | 5×10⁴ s⁻¹ to 7×10⁶ s⁻¹ |
| Speed Steps | 12 discrete settings (800–8000 rpm) |
| Overtemperature Protection | Programmable safety limit |
| Compliance | CE-marked |
| Shipping Weight (Manual System) | 68 kg |
| Shipping Weight (Auto System) | 72.5 kg |
| Shipping Dimensions (Manual) | 61 × 81 × 89 cm |
| Shipping Dimensions (Auto) | 61 × 81 × 127 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS 3000 |
| Product Type | Laboratory Instrument |
| Test Parameter | HTHS Viscosity |
| Compliance Standards | ASTM D4683, ASTM D6616, SAE J300, GB/T 6538 |
| Dimensions (W × D × H) | 66 × 66 × 48 cm |
| Weight | 38.5 kg |
| Power Supply | 100–240 VAC, ≤6 A, 50/60 Hz |
| Viscosity Range | 1–30 mPa·s (cP) |
| Sample Volume | 40 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Auto-sampler Capacity | 1–40 samples per sequence |
| Temperature Control Setpoints | 80 °C, 100 °C, 150 °C (±0.1 °C) |
| Shear Rate Range | 5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature) |
| Display | Digital touchscreen interface |
| Safety Features | Automatic torque motor and stator heater shutdown upon power interruption |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TEOST |
| Pricing | Upon Request |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TFAB |
| Product Type | Laboratory Instrument |
| Test Parameter | Foam Characteristics |
| Compliance Standards | ASTM D892, IP 146, ISO 6247 |
| Dimensions (W×D×H) | 61 × 61 × 53 cm |
| Weight | 72.5 kg |
| Power Supply | 220 V, Single-phase, 10 A, 50/60 Hz |
| Heating Medium | Forced Air |
| Motor | DC-driven, maintenance-free |
| Aeration Head | Stainless steel cylindrical head with pre-heated air supply |
| Air Flow System | Dual integrated mass flow meters |
| Air Flow Rate | 94–200 mL/min (±5 mL/min) |
| Temperature Range | 20–175 °C (±0.1 °C) |
| Test Programs | Four standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C) |
| Sample Volume | 200 mL |
| Test Capacity | Six 1000-mL graduated cylinders |
| Display | Touchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking |
| Safety | Dual thermal protection (fuse + current-limiting fuse), CE certified |
| Shipping Weight/Dimensions | ~90 kg / 71 × 71 × 122 cm |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Laboratory Instrument |
| Model | SB+2 |
| Application Scope | Lubricating Oil & Low-Temperature Fluid Characterization |
| Compliance Standards | ASTM D5133, D7110, D2983, D4684, D445, D97, D2500 |
| Temperature Range | +30 °C to –70 °C |
| Temperature Control Accuracy | ±0.1 °C (programmed), ±0.03 °C (manual) |
| Cooling Rate | 1 °C/h (for Brookfield Scan/Gel Index), Isothermal for Brotz–Feldt Viscosity |
| Bath Medium | Methanol (temperature-dependent) |
| Dimensions (W×D×H) | 48 × 61 × 69 cm |
| Net Weight | ~86 kg |
| Power Supply | 220 VAC, 50/60 Hz |
| Safety Certifications | CE |
| Transport Weight (Bath Unit) | ~123 kg |
| Transport Dimensions (Bath Unit) | 66 × 59 × 122 cm |
| Brand | TE / Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TS |
| Detection Principle | Combustion Microcoulometry |
| Portability | Benchtop (Non-portable) |
| Analyte | Total Sulfur (S) |
| Measurement Range | 0.0020–500 mg absolute sulfur |
| Detection Limit | 0.020 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D3229, ASTM D5453, ASTM D7039, ISO 20846, ISO 20884, IP 512, UOP 97, EN ISO 20846, SH/T 0689 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP582 |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 150 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 600 W (main) + 1000 W (auxiliary) |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Timing Range | 1 min to 24 h |
| Time Display | LED digital |
| Temperature Display | 7-segment LED |
| Sample Capacity | Up to 12 copper strips (4 test wells per bath, configurable multi-bath operation) |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1800 W |
| Dimensions (W×D×H) | 480 × 360 × 520 mm |
| Weight | 18 kg |
| Compliance Standards | GB/T 5096, GB/T 7326, ASTM D130, ASTM D4048, SH/T 0232, SH/T 0023, ISO 6251 |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP651 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 100 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ≤4 °C |
| Temperature Resolution | 0.1 °C |
| Bath Temperature Setpoints | 54 °C ±1 °C (standard), 82 °C ±1 °C (for viscous oils) |
| Stirring Duration | 5 min (automated) |
| Stirrer Positioning | Descends to 6 mm above cylinder bottom |
| Cylinder | 100 mL calibrated glass cylinder |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | ≤1600 W |
| Dimensions (W×D×H) | 510 mm × 360 mm × 580 mm |
| Net Weight | 23.5 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Brand | TimePower |
|---|---|
| Model | TP683 |
| Measurement Principle | Oxygen Bomb Combustion with Mercury Nitrate or Barium Chloride Titration |
| Compliance | DL/T 433, GB/T 388 |
| Max Operating Pressure | ≥20 MPa |
| Ignition Voltage | 12–24 V DC |
| Repeatability (RSD) | ≤0.0006% (w/w) |
| Ambient Temperature Range | 10–40 °C |
| Relative Humidity | 30–80% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 300 × 300 × 390 mm |
| Cooling Method | Integrated High-Flow Air Cooling |
| Net Weight | 8.7 kg |