Phosphate Silicate Monitor
Filter
Showing 31–40 of 40 results
| Brand | Shenchanghong |
|---|---|
| Model | CHYP-250 |
| Type | Benchtop Laboratory Analyzer |
| Measurement Range | 0.00–50.00 mg/L PO₄³⁻ (as P) |
| Resolution | 0.01 mg/L |
| Accuracy | ≤ ±5% FS |
| Repeatability | ≤ 3% RSD |
| Optical Stability | ≤ 0.002 A/20 min |
| Dimensions (H×W×D) | 130 × 266 × 200 mm |
| Power Consumption | 30 W |
| Weight | < 2 kg |
| Compliance | Designed for ASTM D515-89, ISO 6878:2004, and EPA Method 365.1 workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | 2230XP |
| Type | Online Analyzer |
| Detection Range | 0–5000 ppb (SiO₂) |
| Low-Range Accuracy | Optimized for 0–500 ppb |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Light Source | 810 nm LED (filter-free, fiber-optic-free) |
| Sample Temperature Control | Integrated heater maintains 25 °C |
| Zero Calibration | Performed before each analysis cycle |
| Pump Maintenance Interval | Every 6 months |
| Power Input | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Data Storage | 31 days of calibration and measurement logs |
| Display | Backlit LCD with multi-parameter status view |
| Installation | Panel-mount or wall-mount compatible |
| Compliance | Designed for continuous operation in power generation, semiconductor, and pharmaceutical water monitoring environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2230XP |
| Instrument Type | Online Analyzer |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Enclosure Rating | NEMA 4 |
| Reagent Consumption | 0.2 mL per reagent per analysis |
| Measurement Range | 0–5000 ppb SiO₂ (with enhanced accuracy in 0–500 ppb sub-range) |
| Temperature Control | Heats sample to 25 °C for low-temperature inlet streams |
| Light Source | 810 nm LED (filter-free, fiber-optic-free, maintenance-free) |
| Pump Maintenance Interval | Every 6 months |
| Data Storage | 31 days of calibration and analytical records |
| Display | Backlit LCD with multi-parameter status visualization |
| Auto-Restart Function | Configurable 30-minute timeout after STOP command |
| Sample Interface | Integrated on-line flow cell + optional grab-sample port |
| Installation | Panel-mount or wall-mount compatible |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 2118XP |
| Type | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) |
| Display | Backlit LCD |
| Compliance | Designed for ASTM D4356, ISO 10523, and USP <645> water quality monitoring environments |
| Communication Options | Optional digital communication module (Modbus RTU/ASCII, 4–20 mA analog output) |
| Expandability | Optional second channel for pH or conductivity measurement |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Thermo Scientific 2118XP |
| Instrument Category | Online Analyzer |
| Detection Range | 0–200 ppb |
| Sensor Principle | Iodide-Selective Electrode (ISE) with Onboard Reagent Dosing |
| Display | Backlit LCD |
| Calibration Interface | Guided On-Screen Calibration Workflow |
| Expandability | Optional dual-channel configuration (pH or conductivity), optional digital communication module (Modbus RTU/ASCII, 4–20 mA output) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Orion 8030cX |
| Instrument Type | Online Analyzer |
| Measurement Principle | Heteropoly Molybdenum Blue Colorimetry |
| Detection Range | 0–5000 µg/L SiO₂ |
| LOD | <0.5 µg/L (typical, phosphate-compensated) |
| Enclosure Rating | IP65 |
| Reagent Replacement Interval | ≤100 days |
| User Interface | Capacitive Touchscreen Display |
| Platform Compatibility | Orion 8000 Series Multi-Parameter Platform |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | Timepower |
|---|---|
| Model | TP107 |
| Type | Online Analyzer |
| Origin | Beijing, China |
| Manufacturer | Timepower (Producer) |
| Measurement Principle | Vanadomolybdophosphoric Yellow Colorimetry (Acidic Medium) |
| Display | 7.0-inch Color TFT Touchscreen (Chinese UI) |
| Range Options | 0.00–20.00 mg/L or 0.00–50.00 mg/L |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Drift | ≤±1% F.S./24 h |
| Response Time | < 4 min |
| Cycle Time | ~3 min per channel |
| Sample Flow Rate | 10–40 L/h |
| Sample Temp. | 5–50 °C |
| Suspended Solids | < 5 µm, non-colloidal |
| Ambient Temp. | 5–45 °C |
| Ambient Humidity | ≤90% RH (non-condensing) |
| Reagent Consumption | ~3 L/month |
| Output Signals | Isolated 0–20 mA / 4–20 mA / 0–10 mA (programmable) |
| Alarm Outputs | Independent per channel (flow loss, high/low limit) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤100 W |
| Dimensions (W×H×D) | 460 × 720 × 280 mm |
| Panel Cutout | 670 × 410 mm |
| Weight | 22 kg |
| Compliance | GB/T 6913–2008 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Benchtop Laboratory Analyzer |
| Model | TP306 |
| Measurement Principle | Molybdenum Blue Colorimetric Method (Silicomolybdic Acid Reduction) |
| Display | 5.0-inch TFT color touchscreen with Chinese UI |
| Optical Source | Imported monochromatic cold-light LED (peak λ = 650 nm ± 5 nm) |
| Detection Range | 0–200 µg/L SiO₂ (extendable to 1000 µg/L via dilution) |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% FS or ±1 µg/L (whichever is greater) |
| Repeatability | ≤1.5% RSD |
| Blank Calibration | Automatic zero-point and electronic drift compensation |
| Data Storage | Cyclic memory for up to 256 test records |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Dimensions | 320 × 240 × 180 mm |
| Weight | 4.2 kg |
| Compliance | Designed per GB/T 12149–2019 (Chinese Standard for Silica Determination in Boiler Water and Feedwater), ASTM D859–22 (Standard Test Method for Silica in Water), and ISO 10523:2022 (Water Quality — Determination of pH) |
| Brand | Yetuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YT-2810 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Display | 5.0-inch color TFT touchscreen (Chinese UI) |
| Measurement Range | 0–200 µg/L or 0–2000 µg/L (selectable) |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1% |
| Drift | ±1% F.S./4 h |
| Light Source | Imported monochromatic cold LED |
| Method | Standard colorimetric analysis per Chinese national standard (1,10-phenanthroline method for phosphate |
| Dimensions | 270 mm × 200 mm × 190 mm |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | 30 W |
| Operating Temperature | 5–45 °C |
| Operating Humidity | <90% RH (non-condensing) |
| Weight | 4 kg |
| Brand | Zming Environmental Technology Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Model | HQ-6200 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Performance Colorimetry (Molybdenum Blue Method) |
| Detection Range | 0.05–5 mg/L PO₄–P and 0.5–50 mg/L PO₄–P (dual-range auto-switching) |
| Detection Limit | 0.02 mg/L PO₄–P |
| Sample Cycle Time | ≤5 minutes (from aspiration to result output) |
| Reagent Consumption | <10 µL per measurement |
| Operating Mode | Programmable single-shot, continuous, periodic, or event-triggered measurement |
| Cleaning System | Integrated automated ultrasonic + air-pulse cleaning module |
| Compliance | Designed to support ISO 15586, ASTM D515-18, and EPA Method 365.1 workflows |
| Software Interface | RS485/Modbus RTU, optional Ethernet/IP and OPC UA |
| Enclosure Rating | IP65 |