| Key Features | Stainless steel test chamber |
|---|---|
| Humidity control | 30–65% RH |
| Rotating sample rack | 1 rpm, 360° continuous rotation |
| Gas flow velocity | 8–16 mm/s |
| Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-1 | 2004 |
| Electrical supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, ±0.5 °C stability |
| Humidity range | 30–65 % RH |
| Sample rack rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | OK |
|---|---|
| Model | OK-CY Series |
| Type | Environmental Test Chamber |
| Application | Ozone Resistance Testing of Polymers and Rubber |
| Temperature Range | 25–80 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + 7″ Color Touchscreen HMI |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotating (1 rpm), Static/Dynamic Configurable |
| Gas Flow Velocity | 8–16 mm/s |
| Safety Protections | Leakage, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Compliance | GB/T 7762, ISO 1431-1, ASTM D1149, JIS K 6259 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5-year service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leakage/short-circuit/overheat/motor-overcurrent protection |
| Interface | 4–20 mA analog output, RS232 communication port |
| Calibration Port | Integrated metrology interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,200 (FOB Shanghai, ex-works reference only) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Sample Rotation | 360° motorized turntable, 1 rpm (static/dynamic test modes optional) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Communication Interface | RS232, 4–20 mA analog output |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Nondispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Control Accuracy | ±10 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Sensor | Nondispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens S7-1200 PLC |
| Output Interface | 4–20 mA analog, RS232 serial |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,200 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Temperature Stability | ±0.5 °C |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Safety Protections | Leakage, Short-Circuit, Overtemperature, Motor Overheat, Overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume | 80 L / 225 L / 500 L / 1000 L |
| Internal Dimensions (W×H×D, cm) | 40×50×40 |
| External Dimensions (W×H×D, cm) | 100×170×90 |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Imported UV Absorption Analyzer with 4–20 mA Output & RS232 Interface |
| Sample Rack | Motor-Driven, 360° Continuous Rotation (1 rpm), Cycloidal Trajectory Compliance |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weintek Color Touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage Current, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel ozone test chamber with fully enclosed silent-discharge ozone generation circuit |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, fluctuation ±0.5 °C |
| Humidity range | 30–65 % RH |
| Sample rack | 360° continuous rotation at 1 rpm (static/dynamic modes optional) |
| Gas flow velocity | 8–16 mm/s |
| Control system | Weilun color touchscreen + Siemens PLC |
| Ozone sensing | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Output | 4–20 mA analog + RS232 digital interface |
| Safety | Leakage, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power supply | AC 380 ±5 V / 50 ±0.5 Hz |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Mounting | Dynamic (360° rotation at 1 rpm) & Static options |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Ozone Detection | Non-dispersive UV Sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppmv (pphm) |
| Temperature Range | 25–40 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Sample Rack Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 yr) |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage, short-circuit, over-temperature, motor overheat, over-current |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output Interface | 4–20 mA analog output, RS232 serial communication |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | Palas |
|---|---|
| Origin | Germany |
| Model | U-SMPS 1700 |
| Particle Size Range | 2–400 nm |
| Particle Concentration Range | 0–10⁸ particles/cm³ |
| Classification Channels | Up to 128 (logarithmic or linear stepping) |
| Measurement Time per Scan | As low as 30 s |
| Compliance | ISO 15900 (Differential Mobility Analysis), EN 13274-6, ASTM F3233 |
| Interface Options | USB, LAN, WLAN, RS-232/485 |
| Display | 7-inch capacitive touchscreen GUI |
| Data Logging | Integrated high-resolution time-stamped recorder |
| Interoperability | Compatible with third-party DMAs, CPCs (e.g., TSI, Grimm), and electrometers |
| Brand | PAMAS |
|---|---|
| Origin | Germany |
| Model | S40 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Particle Size Channels | 8 user-configurable thresholds |
| Compliance Standards | ISO 4406:1987 / ISO 4406:1999 / SAE AS4059D / NAS1638 |
| Power Supply | 90–230 V AC, 50 Hz |
| Weight | ~9 kg |
| Dimensions | 300 × 140 × 300 mm |
| Display | Backlit touchscreen LCD |
| Data Interface | RS-232C (ASCII 8-bit) |
| Internal Storage | 500 measurement records |
| Sampling Pressure Range | 0–420 bar |
| Viscosity Limit | ≤200 cSt (unpressurized), ≤350 cSt (pressurized), ≤1000 cSt (lubricating oil systems) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 1,350 (FOB) |
| Drive System | Taiwan-made AC Frequency-Controlled Motor |
| Actuation | Precision Ball Screw Vertical Movement |
| Load Cell | U.S.-Sourced Explosion-Proof Load Cell (±0.5% FS accuracy) |
| Control System | Embedded Microprocessor-Based Controller with Real-Time Data Acquisition |
| Output | Thermal Printer Integrated |
| Safety | Automatic Emergency Stop upon Crush Detection |
| Compliance | Meets ASTM D642, ISO 12048, and TAPPI T804 requirements |
| Brand | TLS |
|---|---|
| Origin | Spain |
| Model | T-2911 |
| Type | Import |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | Paratronix |
|---|---|
| Model | ETA-01 |
| Force Sensor Range | 0.5–25 kg (selectable) |
| Force Resolution | 0.0001–0.001 g |
| Displacement Resolution | 0.0001 mm |
| Stroke Range | 0–310 mm |
| Test Speed | 0.001–45 mm/s |
| Data Acquisition Rate | Up to 4,000 Hz |
| Compliance | GB/T 28304-2012, GB/T 6783-2013, ASTM D1894-90, AACC 16-50 & 74-09, SC/T 3702-2014, NY/T 1180-2006, AFERA 4013/4015/5001/5004, FINAT Method 3/5/6/9/18/22 |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GPT-01 |
| Max Test Pressure | 6.00 MPa |
| Pressure Ramp Rate | 0.4 MPa/s ± 0.1 MPa/s |
| Pressure Range | 0.50–6.00 MPa |
| Pressure Resolution | 0.01 MPa |
| Pressure Accuracy | < ±1.5% F.S. |
| Ramp Rate Accuracy | < ±5% |
| Cycle Time (to 1.60 MPa) | ~4 s |
| Throughput | 5–10 bottles/min |
| Bottle Neck Diameter Compatibility | Φ24–29 mm (customizable) |
| Operating Temp | 0–40 °C |
| RH Limit | < 95% |
| Power Supply | 220 VAC ±5%, grounded |
| External Air Supply Required | 0–0.8 MPa |
| Safety Enclosure | Integrated tempered safety glass |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PMT-100N |
| Max Test Force | 50 N |
| Loading Speed Range | 0.1–200 mm/min (infinitely variable) |
| Force Resolution | 0.01 N |
| Rigidity Measurement Range | 100 N |
| Rigidity Accuracy | ±0.3% F.S. |
| Deflection Resolution | 0.01 mm |
| Support Span Adjustment | 1–60 mm |
| Flexibility Test Frequency | 0.1–1.0 Hz |
| Bend Angle Range | 1–30° |
| Bend Angle Accuracy | ±0.1° |
| Bend Cycle Count | 1–999 cycles |
| Bend Gauge Length | 5–100 mm |
| Gauge Length Accuracy | ±0.1 mm |
| Effective Stroke | 150 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 420 × 350 × 620 mm |
| Weight | ~30 kg |
| Brand | Paratronix |
|---|---|
| Model | PMT-100N |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Maximum Test Force | 50 N |
| Load Speed Range | 0.1–200 mm/min (infinitely variable) |
| Force Resolution | 0.01 N |
| Force Accuracy | ±0.3% FS |
| Deflection Resolution | 0.01 mm |
| Deflection Accuracy | ±0.01 mm |
| Support Span Adjustment Range | 1–60 mm |
| Bending Angle Range | 1–30° |
| Angular Accuracy | ±0.1° |
| Bend Cycle Count | 1–999 cycles |
| Bend Frequency | 0.1–1.0 Hz |
| Bending Gauge Length | 5–100 mm |
| Gauge Length Accuracy | ±0.1 mm |
| Specimen Diameter Range | 0.2–3.4 mm |
| Effective Stroke | 150 mm |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 420 × 350 × 620 mm |
| Weight | ~30 kg |
| Brand | Paratronix |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PMT-100N |
| Max Test Force | 50 N |
| Loading Speed Range | 0.1–200 mm/min (infinitely variable) |
| Force Resolution | 0.01 N |
| Bending Angle Range | 1–30° |
| Bending Frequency | 0.1–1.0 Hz |
| Span Adjustment Range | 5–100 mm |
| Span Accuracy | ±0.1 mm |
| Wall Thickness Modes | Standard / Thin / Ultra-Thin Wall Selection |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 420 × 350 × 620 mm |
| Weight | ~30 kg |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6200 |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Bomb Pressure Rating | 200 atm |
| Bomb Volume | 342 mL |
| Data Storage Capacity | 1000 tests |
| Interface Options | RS-232, USB, Ethernet, Balance Integration, Printer Port |
| Operating System | Linux-based embedded controller |
| Calibration & Reporting | Automatic correction for fuse wire, nitric acid formation, sulfur oxidation, and hydrogen combustion enthalpy |