| Key | Internal Dimensions: 400 × 400 × 500 mm (L×W×H) |
|---|---|
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20–98 %RH |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.5 %RH |
| Temp. Uniformity | ±1.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Heating Rate | +20 °C to +150 °C in ≈30 min |
| Cooling Rate | +20 °C to −40 °C in ≈50 min |
| Controller | TEMI880 Touchscreen HMI (Bilingual English/Chinese) |
| Refrigeration System | Hermetic Compressor, R404A/R23 Refrigerants |
| Air Circulation | Multi-wing Centrifugal Fan (Oriental Motor), Horizontal Diffusion + Vertical Thermal Exchange |
| Water Supply | Integrated 25 L Stainless Steel Reservoir with Auto-Replenishment & Low-Water Alarm |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Internal Dimensions | 50 × 75 × 60 cm (W×H×D) |
| External Dimensions | 107 × 175 × 110 cm (W×H×D) |
| Inner Material | SUS#304 Stainless Steel |
| Outer Material | SUS#304 High-Tensile Stainless Steel with Multi-Layer Passivation Coating |
| Insulation | High-Density Glass Wool + Rigid Polyurethane (PU) Foam |
| Refrigerants | R404A & R23 (Zero ODP, Low GWP HFCs) |
| Viewing Window | Multi-Layer Vacuum-Sealed, Explosion-Proof Tempered Glass |
| Air Circulation | Horizontal Diffusion + Vertical Heat Exchange Arc-Type Forced Convection |
| Safety Compliance | Dual-Stage Over-Temp/Over-Humidity Protection, Power-Failure Memory, Door Interlock, Ground Fault Circuit Interrupter (GFCI) |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200–14,800 (FOB, model-dependent) |
| Chamber Volume | 100 L / 225 L / 500 L / 1000 L |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6.0 kW |
| Lamp Life | ≥1,500 h (at nominal irradiance) |
| Spray Cycle | 1–999 min (programmable intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | PS |
|---|---|
| Origin | Switzerland |
| Model | XPT-CP&CV |
| Product Type | Intelligent Online Analyzer |
| Display | Digital |
| Measurement Range | 10 µm – 3 mm |
| Compliance | ASTM E2457, ISO 13322-2, FDA 21 CFR Part 11 (with hardware token & electronic signature) |
| Configuration Options | XPT-P (in-process probe), XPT-C (suspension flow cell), XPT-CP (powder feeder + vibratory dosing), XPT-CV (Venturi vacuum-sampling closed-loop system) |
| Enclosure Rating | IP65 (XPT-CV), Stainless Steel Housing |
| Imaging | High-speed CCD with ultra-short shutter time or pulsed LED illumination |
| Frame Rate | ≥30 fps |
| Data Throughput | Thousands of particles analyzed and stored per second |
| Software Architecture | Parallelized real-time image acquisition and analysis engine |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Model | AccuSizer 780 A9000 FX-MD |
| Detection Principle | Focused Light Obscuration & Single Particle Optical Sizing (SPOS) |
| Size Range | 0.6 µm – 20 µm |
| Maximum Sample Concentration | 1 × 10¹² particles/mL |
| Number of Adjustable Channels | 32 user-defined |
| Flow Rate | 15 – 180 mL/min |
| Sample Volume | 2 – 10 mL |
| Diluent | Ultrapure water (standard), organic solvents (optional) |
| Power Supply | 100–120 VAC, 60 Hz or 220–240 VAC, 50 Hz |
| Dimensions (Counter Unit) | 20 cm × 45 cm × 20 cm |
| Dimensions (Auto-Dilution Unit) | 25 cm × 45 cm × 56 cm |
| Weight | ~30 kg |
| Compliance | ISO 21501-4, USP <788>, <789>, ASTM F2149, FDA 21 CFR Part 11 ready |
| Brand | Particle Sizing Systems (PSS), USA |
|---|---|
| Origin | USA |
| Model | Nicomp ZLS |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | 99% |
| Repeatability | 99% |
| Key Features | Temperature Range: RT+10°C to 132°C |
|---|---|
| Humidity Range | 100% RH (saturated steam) |
| Pressure Range | 0–2.8 kg/cm²(g) (relative gauge pressure) |
| max vessel rating | 4.0 kg/cm²(g) |
| Internal Chamber Dimensions | ∅250×450 mm, ∅350×500 mm (customizable) |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Heating Method | Insulated stainless-steel sheathed heaters with PID + SSR control |
| Humidity & Pressure Generation | Saturated steam via electrically heated water reservoir |
| Circulation | Natural convection of saturated steam |
| Chamber Material | SUS304 stainless steel (interior), SECC steel with electrostatic powder coating (exterior) |
| Compliance | ASTM D3045, DIN 53479, ISO 2231, IEC 60068-2-13, JIS C 0021, UL 746B, MIL-STD-810H, NACE TM0177, BS EN 60068-2-30 |
| Safety Systems | Automatic pressure relief, vacuum break, door interlock with pressure-dependent mechanical sealing, low-water auto-refill, real-time fault diagnostics |
| Brand | OEM |
|---|---|
| Internal Chamber Dimensions | ∅250×450 mm (OK-PTC-25) or ∅350×500 mm (OK-PTC-35) |
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max working pressure 3.0 kg/cm² (absolute), safety limit 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Cabinet | SECC steel with electrostatic powder coating |
| Compliance | ASTM D2247, DIN 50017, IEC 60068-2-66, ISO 11357-4, JIS C 0045, MIL-STD-810H, UL 1598, NACE TM0177, BS EN 60068-2-30 |
| Key Features | Internal Chamber Diameter × Depth: ∅250×450 mm (PTC-25) or ∅350×500 mm (PTC-35) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safe capacity 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0→2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Compliance | ASTM, DIN, BS, IEC, NACE, UL, CNS, ISO, JIS, MIL |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171/GB/T 18854) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (cleaning) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | –0.08 to 0.8 MPa |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601J |
| Instrument Type | Optical Light-Blockage Particle Counter |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signature, Role-Based 5-Tier User Access |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Channel Resolution | 1000 Adjustable Channels (Down to 0.01 µm), Configurable Size Ranges (e.g., 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Measurement Range | 1–450 µm (Extended Options: 0.03–3000 µm) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Repeatability | <2.5% coincidence error at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Regulatory Alignment | ChP 0903 (2015/2020), USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406 |
| Brand | PULUODY |
|---|---|
| Model | PLD-601Q |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±5% typical (per USP <788>, ISO 21501-4, ChP 2020) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GMP/GLP audit trail, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9–2013, GB 8368, ISO 21501-4, ISO 11171, NAS 1638 |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PS-1006 |
| Breakdown Voltage Range | 0–80 kV |
| Step-Up Transformer Capacity | 1.5 kVA |
| Step-Up Rates | 2.0 / 2.5 / 3.0 / 3.5 kV/s (selectable) |
| Electrode Gap | 2.5 mm (standard) |
| Power Supply | AC 220 V ±10%, 50 ±5 Hz |
| Power Consumption | <200 W |
| Ambient Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% |
| Display | Large LCD with Chinese character interface |
| Dimensions | 760 × 670 × 770 mm |
| Weight | 48 kg |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-LD07 |
| Chamber Volume | ≥0.5 m³ |
| Test Voltage Range | 100–600 V AC |
| Electrode Force | 1.0 N ± 0.05 N |
| Electrode Material | Platinum |
| Droplet Volume | 44–50 drops/cm³ |
| Droplet Height Adjustment | 30–40 mm |
| Droplet Interval | 30 ± 5 s |
| Short-Circuit Current Threshold | ≥0.5 A (cut-off after 2 s) |
| Voltage Drop Limit | ≤10% at 1 A ± 0.1 A |
| Power Supply | AC 220 V / 50 Hz |
| Construction | Stainless Steel & Brass Housing |
| Compliance | IEC 60112, IEC 60335-1, GB/T 4207, GB 4706.1, GB 2099.1, VDE 0620 |
| Brand | Product Intelligence and Creativity |
|---|---|
| Origin | Beijing, China |
| Model | PZ-1000SD-A |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Dimensions | 120 × 180 mm |
| Optical Magnification | 0.7–4.5× |
| Surface/Interfacial Tension Range | 0–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Heating System | Programmable High-Temperature Furnace (up to 1600 °C), 30-Step Ramp/Soak Control, ±0.1 °C Stability ≤1000 °C |
| Vacuum System | Molecular Pump, Wide-Range Vacuum Gauge |
| Imaging System | Monochrome Industrial CCD Camera (130 W pixels, 25 fps), Telecentric Zoom Lens |
| Light Source | Adjustable Blue-Tone LED Cold Illumination (Lifespan >25,000 h) |
| Software | Automated Image Analysis Suite with Circle, Ellipse, Oblique Ellipse, Differential Circle/Ellipse, and Dynamic Video Sequence Fitting Algorithms |
| Compliance | GB/T 24368-2009, SY/T 5153-2007, ASTM D724-99(2003), ASTM D5946-2004, ISO 15989 |
| Brand | Product Intelligence & Creativity |
|---|---|
| Origin | Beijing, China |
| Model | PZ-E2 |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | 0–100 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Test Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sample Volume Requirement | ≥3 mL (plate), ≥5 mL (ring) |
| Power Consumption | 100 W |
| Dimensions (L×W×H) | 20 × 35 × 35 cm |
| Weight | 7.5 kg |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-SUN B02-S |
| Xenon Lamp Power | 1800 W |
| Compliance | ISO 105-B02, ISO 105-B04, AATCC TM 16 (Option 2 & 3), AATCC TM 169, M&S C9/C9A |
| Sample Capacity | 31 AATCC pre-cut specimens (1882 cm² total exposure area) |
| Lamp Type | Air-cooled xenon arc lamp |
| Lamp Life | ~1500 hours |
| Temperature Control | Blackboard temperature (35–103 °C), chamber air temperature |
| Humidity Control | Relative humidity (RH) with optional water spray |
| Filter System | Dual-filter assembly (outer borosilicate tube + inner 7-element filter set) for Window-IR (ISO/M&S) or Window-B/SL (AATCC) spectral profiles |
| Brand | Q-LAB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV (Imported from USA) |
| Quotation | Upon Request |
| Illuminant Temperature Range (°C) | Configurable per test standard |
| Black Panel Temperature Range (°C) | 35–80 °C (typical operating range) |
| UV Wavelength Range (nm) | 295–400 nm (selectable via lamp type: UVA-340 or UVB-313) |
| Chamber Dimensions (L×W×H) | 1100 × 500 × 420 mm (standard QUV se model) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SE |
| Chamber Dimensions (L×W×H) | 114 × 50 × 40 cm |
| Light Source Options | UVA-340 or UVB-313 fluorescent lamps |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Black Panel Temperature Range | 35–80 °C |
| Condensation Temperature Range | 40–60 °C |
| Illumination Temperature Range | 45–80 °C |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Power Supply | 120 V / 60 Hz, 16 A or 230 V / 50–60 Hz, 8 A |
| Water Consumption | 8 L/day (condensation mode) |
| Lamp Life (avg.) | 5000 h |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Xe-1 |
| Xenon Lamp Power | 1800 W |
| Lamp Cooling | Air-cooled |
| Lamp Lifetime | ~1500 hours |
| Filter Options | Daylight-F / Daylight-Q / Daylight-B/B / Window-Q / Window-B/SL / Window-SF-5 / Window-IR / Extended UV-Q/B |
| Sample Mounting | Horizontal flat tray |
| Chamber Type | Benchtop |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 105-B02, GB/T 16422.2 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Xe-3-HDS |
| Lamp Type | Air-Cooled Xenon Arc Lamp (3-lamp configuration) |
| Spectral Range | Full-spectrum solar simulation (290–800 nm) |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, or TUV 300–400 nm) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | Ambient to 90 °C (with optional refrigerated cooling unit) |
| Relative Humidity Control | 10–95% RH (standard) |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Sample Capacity | Up to 51 specimens (51 mm × 102 mm) |
| Dual Spray System | Standard (deionized water + secondary solution, e.g., acid rain or detergent) |
| Calibration | AUTOCAL® automated calibration system |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Interface | Touchscreen controller with built-in Ethernet, self-diagnostic alerts, GLP/GMP-ready audit trail logging |
| Brand | QDLaser |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | QVFM Series |
| Pricing | Upon Request |
| Laser Wavelength Options | 405–1064 nm (1–3 wavelengths selectable) |
| Resolution | 720p @ 60 fps (input source) |
| Field of View | 39° (H) × 23° (V) |
| Focus | Autofocus-free (fixed-focus optical design) |
| Scan Modes | Raster and vector scanning |
| Power Consumption | Peak 6.5 W, typical <5.5 W |
| Dimensions | 52.00 × 38.40 × 16.75 mm |
| Laser Packaging | TO-38 or TO-56 hermetic can |
| Output Power Range | 7–220 mW (model-dependent, CW) |
| Primary Applications | 3D machine vision, LiDAR sensing, retinal projection, industrial defect detection, biomedical instrumentation, automotive ADAS components, micro-display systems |
| Brand | QiaoBang Instrument |
|---|---|
| Origin | Jiangsu, China |
| Model | XAD |
| Price Range | USD 125,000 – 210,000 |
| Measurement Principle | Total External Reflection X-Ray Fluorescence (TXRF) with Multi-Channel Capillary Optics |
| Minimum Spot Size | 10 µm |
| Excitation Intensity Gain | 10²–10³× vs. conventional collimators |
| Compliance | ASTM F1689, ISO 3497, IPC-4552A, USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | QiaoBang Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XD1000 |
| Price Range | USD 16,500 – 27,500 |
| Brand | Qigao Instruments (SHQIGAO) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-510G-4 |
| Temperature Range | –50 °C (dual-bath isothermal operation), ±1 °C accuracy |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ≤2 °C across bath volume |
| Cooling Rate | 0.7–1 °C/min |
| Heating Rate | 1–3 °C/min |
| Temperature Resolution | 0.1 °C |
| Control Accuracy | ±0.1 °C (display), ±1 °C (setpoint maintenance) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1500 W |
| Ambient Operating Conditions | ≤30 °C, ≤85% RH |
| Brand | Qingji |
|---|---|
| Origin | Shanghai, China |
| Model | QJ211WS-50KN |
| Maximum Load Capacity | 50 kN |
| Accuracy Class | 0.5 |
| Effective Force Measurement Range | 0.2–100% FS |
| Force Resolution | 500,000 counts (full-scale, unsegmented) |
| Bending Moment Capacity | ≥10,000 N·m |
| Horizontal Load Capacity | ≥40,000 N |
| Lifting Capacity | ≥100 kg |
| Horizontal Travel (4-directional) | ≥1.5 m |
| Vertical Travel | ≥1.6 m |
| Loading Stroke | ≥400 mm |
| Software Platform | Windows-based real-time data acquisition and curve visualization |
| Brand | QINGTAO |
|---|---|
| Model | QT-N1 |
| Measurement Principle | Dual-mode (Eddy Current for Non-Magnetic Substrates, Magnetic Induction for Ferrous Substrates) |
| Measurement Range | 0–1250 µm |
| Resolution | 0.1 µm |
| Accuracy | ±(3% H + 1.5 µm) with Single-Point Calibration |
| Substrate Compatibility | Ferrous metals (Fe, steel) and non-ferrous non-magnetic metals (Al, Cu, Zn, Sn) |
| Coating Types | Non-conductive (paint, enamel, plastic, rubber) and non-magnetic metallic (e.g., Cr, Zn on steel) |
| Probe Options | F1, F1/90°, F10, N1, N1/90°, N10 |
| Data Storage | 500 readings |
| Statistical Functions | MEAN, MAX, MIN, NO, S.DEV |
| Calibration Modes | Single-point & two-point |
| Operating Temperature | −10 °C to 50 °C |
| Power | 2 × AA (1.5 V) |
| Dimensions | 125 × 67 × 31 mm |
| Weight | ~340 g |
| Compliance | GB/T 4956–1985, GB/T 4957–1985 & –2003, JB/T 8393–1996, JJG 889–1995, JJG 818–1993 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJBCJ |
| Impact Energy Range | 0–50 J (with selectable pendulum scales: 5 J, 7.5 J, 15 J, 25 J, 50 J) |
| Impact Velocity | 2.9 m/s |
| Pendulum Pre-lift Angle | 160° |
| Distance from Pendulum Axis to Specimen Center | 230 mm |
| Support Span Options | 40 mm, 60 mm, 70 mm, 95 mm |
| Notch Knife Edge Angle | 30° |
| Knife Edge Radius | 2 mm |
| Anvil Radius (Clamp Radius) | 1 mm |
| Dimensions (L×W×H) | 280 × 250 × 500 mm |
| Net Weight | 50 kg |
| Compliance | GB/T 1043, ISO 179-1, ISO 9854-1, DIN 8078, DIN 53453 |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJBV-212F |
| Maximum Test Load | 100 kN |
| Crosshead Travel | 200 mm |
| Furnace Chamber Diameter | φ50 mm |
| Furnace Length | 450 mm |
| Host Weight | 850 kg |
| Temperature Range | Ambient to 1200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Constant-Temperature Zone Length | >150 mm |
| Load Control Accuracy | ±1% of set value |
| Load Resolution | 0.1 N |
| Deformation Measurement Error | ±0.5% of reading |
| Deformation Range Options | up to 25 mm |
| Load Measurement Accuracy | ±0.5% of reading (from 1% FS) |
| Crosshead Speed Range | 0.01–180 mm/min |
| Power Consumption | 3 kW |
| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QJYL-2000 / QJYL-3000 |
| Max Load Capacity | 2000 kN / 3000 kN |
| Accuracy Class | Class I (per ISO 7500-1 & ASTM E4) |
| Force Range | 10–3000 kN |
| Loading Speed | 1–15 mm/s (adjustable) |
| Internal Clear Distance | 320 mm |
| Compression Platens | 320 × 320 mm or 400 × 400 mm |
| Motor Power | 0.75 / 1.1 / 2.2 kW |
| Net Weight | 1000 kg / 1500 kg |
| Overall Dimensions | ~520 × 450 × 1350 mm or 700 × 540 × 1800 mm |