Physical Property Testing Instruments
Filter
Showing 3751–3780 of 4355 results
| Brand | SUNS SANSUN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | WZW-600P |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Rotary Bending Fatigue Tester |
| Maximum Test Load | 20 kN |
| Load Range | 1–100% Full Scale (FS) |
| Rotational Speed | 300–6000 rpm |
| Specimen Diameter | Φ8–Φ20 mm |
| Specimen Length | 1200–1500 mm |
| Support Span Adjustment | Inner span 200–400 mm |
| Load Resolution | 1/250,000 of full scale (constant resolution, no range switching) |
| Load Accuracy | ±0.5% of reading |
| Force Stability | ±5 N (10–50 N), ±10% (50–100 N), ±5% (100–10,000 N) |
| Motor Configuration | 5.5 kW main drive motor + dual 1 kW loading motors |
| Overall Dimensions (W×D×H) | ≈2100×1500×1600 mm |
| Key | Brand: SUNS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SUNS-RT Series |
| Max Test Force | 30–100 kN |
| Accuracy Class | 0.5 |
| Test Space Height | 2100 mm |
| Displacement Resolution | 0.04 µm |
| Effective Test Width | 600 mm |
| Speed Range | 0.001–500 mm/min |
| Pipe ID Measurement Range | 50–200 mm / 200–2000 mm |
| ID Measurement Accuracy | ±1% |
| ID Measurement Resolution | 0.01 mm |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,000 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamps |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature (BPT) Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter System | Custom High-Borosilicate Glass + 30% IR-Blocking Filter (optional) |
| Irradiance Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Display & Control | LCD-based Irradiance Accumulation Meter with Auto-Calculation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Time | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ±8 W/m² |
| UV Sensor | Calibrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Filter Requirement | Optional 30 % IR-reducing filter |
| Irradiance Monitoring | LCD-based integrated radiometric energy integrator |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Calibrated UV Spectral Irradiance Transmitter (Developed by No. 622 Research Institute) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| UV Irradiance | 200 ± 8 W/m² |
| UV Spectral Irradiance Transmitter | Integrated, developed by Beijing Institute of Space Mechanics and Electricity (622 Institute) |
| IR-Reduction Filter | Custom 30% infrared energy attenuation filter (optional, specify at order) |
| Irradiance Monitoring | LCD-based cumulative irradiance meter with real-time auto-calculation |
| Cooling System | Internal forced-air circulation cooling |
| UV Transmitting Filter | Single custom high-borosilicate glass filter |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ± 8 W/m² |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90 % |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50 ± 10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Direct Reflective Illumination |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance | 200 ± 8 W/m² (broadband, 295–450 nm) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| IR Filter | Optional 30% infrared energy rejection filter |
| Irradiance Monitoring | LCD-based Cumulative Irradiance Integrator |
| Cooling Method | Internal Forced-Air Circulation System |
| Irradiance Uniformity | ≥90% across sample plane |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Pig |
| Pricing | Upon Request |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Configuration | Top-mounted, Reflective Direct Illumination |
| Irradiance Uniformity | ≥90% |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| IR Filter | Optional 30% Infrared Energy Blocking Filter |
| Irradiance Monitoring | LCD-Based Cumulative Irradiance Integrator with Real-Time Calculation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass (IR-Reduction ~30%) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (calibrated per ISO 4892-2) |
| Control Display | LCD-Based Irradiance Integration & Cumulative Dose Monitoring |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (Single) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across rack surface |
| UV Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| Filter System | Custom High-Borosilicate Glass + IR-Blocking Filter (removes ~30% infrared energy) |
| Control Interface | LCD-based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Cooling Method | Internal Forced-Air Circulation System |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 requirements |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Sample Capacity | 500 × 400 mm Test Tray |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Uniformity | ≥90% across Exposure Plane |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass + Optional IR-Reduction Filter (30% IR attenuation) |
| UV Monitoring | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Control Interface | LCD-Based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Output | 295–450 nm (UV-A/UV-B/Visible) |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Temperature Range | RT to 85°C (operational test temp: 50 ± 10°C) |
| Humidity Range | 40–70% RH (lighting), 50–90% RH (dark cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Rack | 500 × 400 mm stainless steel rack |
| Irradiation Geometry | Top-mounted, direct-reflection configuration |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across exposure area |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ±8 W/m² (295–450 nm) |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (Calibrated per ISO 17025 Traceable Standards) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm (UV-A/UV-B broadband) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral UV Irradiance Transmitter (developed by China Academy of Engineering Physics, Institute 622) |
| IR Filtering | Optional 30 % infrared energy rejection filter (custom order required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Reflector-Assisted Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90% across Exposure Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Adventure |
| Temperature Range | 5–85 °C |
| Relative Humidity Range | 0–98% RH |
| Sample Mass Capacity | 1–5000 mg |
| In-situ Heating/Drying Capability | up to 300 °C |
| Humidity Generation Method | Dual-gas mixing (dry carrier gas + saturated vapor) with digital mass flow control |
| Compatibility | Raman spectroscopy (via optical fiber), color video microscopy, NIR spectroscopy |
| Modularity | Upgradable to organic vapor sorption |
| Construction | Anti-static stainless steel |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET 100 |
| Measurement Principle | Integrating Sphere-Based Directional-Hemispherical Reflectance (DHR) |
| Spectral Range | Six Discrete Bands (1.5–2, 2–3.5, 3–4, 4–5, 5–10.5, 10.5–21 µm) |
| Incident Angles | 20° and 60° from Normal |
| Measurement Time | ≤10 s per acquisition (after 90 s warm-up) |
| DHR Accuracy | NIST-Traceable Calibration |
| Compliance | ASTM E408-22 |
| Power | Rechargeable NiMH Battery Pack (2 units) |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Weight | 2.1 kg (with batteries) |
| Sample Geometry Support | Flat, convex (≥6″ radius), concave (≥12″ radius) |
| Data Storage | Internal SD card (FAT32 formatted, user-replaceable) |
| Display | Touch-enabled LCD interface |
| Probe Design | Modular, field-replaceable measurement head |
| IR Source | Cr-Al-Co alloy filament emitter |
| Brand | SurfaceOptics (SOC) |
|---|---|
| Origin | USA |
| Model | 410 Vis-IR |
| Spectral Range (VIS) | 335–2500 nm (7 bands) |
| Spectral Range (IR) | 1.5–21 µm (6 bands) |
| Incident Angles | 20° & 60° from normal |
| Measurement Time | ~10 s per acquisition |
| Warm-up Time | 90 s |
| Sample Geometry Support | Flat, convex (≥6" radius), concave (≥12" radius) |
| Compliance | ASTM E903, ASTM C1549, ASTM E408 |
| Weight | 2.1 kg (with batteries) |
| Power | Rechargeable NiMH dual battery pack |
| Operating Temp | 0–40 °C (non-condensing) |
| Storage Temp | −25–70 °C |
| Brand | SYMPATEC |
|---|---|
| Origin | Germany |
| Manufacturer | SYMPATEC GmbH |
| Product Type | Imported |
| Model | QICPIC & MIXCEL |
| Instrument Category | Dynamic Image-Based Particle Analyzer |
| Number of Lenses | 6 |
| Measurement Range | 1–3000 µm |
| Dispersion Method | Wet Dispersion |
| Camera Resolution | 4.2 MP |
| Measured Parameters | Chord Length, Feret Diameter (max/min/mean), Fiber Length, Fiber Diameter, Equivalent Circular Diameter, Sphericity, Aspect Ratio, Convexity, Straightness, Elongation, Perimeter Equivalent Diameter (PED), LEFI, DIFI, VBFD |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | MPT-1102 |
| Load Capacity Options | 6 N (standard), 10 N / 30 N / 50 N / 100 N / 200 N / 300 N (optional) |
| Force Resolution | 0.001 N |
| Accuracy | ±0.03% FS |
| Test Speed Range | 1–500 mm/min (infinitely variable, touchscreen-controlled) |
| Effective Travel | 470 mm |
| Displacement Resolution | 0.01 mm |
| Jaw Width | 30 mm (standard), 55 mm (optional) |
| Peel Angles | 90° and 180° (vertical/horizontal configurations) |
| Temperature Control Option | PTC heating module (RT–100°C standard |
| Compliance Standards | GB/T 25256, GB 8808, GB 2792, ASTM D3330 |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 30 W |
| Dimensions (L×W×H) | 750 × 340 × 116 mm |
| Net Weight | 43 kg |
| Interface | Standard RS232/USB for external data transfer |
| Software Support | Flexpert analysis software (optional), DSM Laboratory Data Management System (optional) |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Spec&Scan 2000 |
| Pricing | Upon Request |