| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SI-111 |
| Operating Wavelength | 8–14 µm |
| Field of View | 22° half-angle |
| Accuracy | ±0.2 °C @ −10 to +65 °C |
| Repeatability | ±0.05 °C @ 10 to +65 °C |
| Response Time | <1 s |
| Output | 60 µV/°C (target), 0–2500 mV (sensor body temperature) |
| Housing | Anodized aluminum with germanium optical window |
| Dimensions | Ø23 mm × 60 mm |
| Weight | 190 g |
| Cable | 4.5 m, 4-conductor shielded |
| Operating Ambient | −55 to +80 °C, 0–100 % RH |
| Power Supply | 2.5 V excitation for thermistor |
| Brand | Applied NanoFluorescence |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Nano Spectralyzer NS3 |
| Pricing | Available Upon Request |
| Brand | Applied Spectroscopy |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TranSpec Lite MC-UVNIR-H |
| Wavelength Range | 190–1020 nm |
| Measurement Range | 0.8–100 µm |
| Accuracy | ±0.005 µm |
| Repeatability | ±0.002 µm (per standard WEG test) |
| Brand | Applytest |
|---|---|
| Model | NMM-1020 |
| Measurement Principle | Eddy Current |
| Power Supply | Rechargeable Lithium Battery (20 h runtime) |
| Minimum Sample Size | 150 × 150 mm (flat) |
| Active Measurement Area | Ø40 mm |
| Measurement Mode | Contact or Non-Contact (non-contact requires optional probe holder) |
| Supported Substrates | Plastic, Glass, Polymer Films, Semiconductor Wafers |
| Bluetooth Data Transfer | Optional |
| Compliance | ISO/IEC 17025-compatible operation environment, supports GLP audit trails |
| Brand | Applytest |
|---|---|
| Model | NMM-1020 |
| Measurement Principle | Eddy Current |
| Power Supply | Rechargeable Lithium Battery (20 h runtime) |
| Minimum Sample Size | 150 × 150 mm (flat) |
| Active Measurement Area | Ø40 mm |
| Surface Compatibility | Flat and Curved Substrates (custom calibration profiles supported) |
| Measurement Modes | Contact and Non-Contact (non-contact requires optional probe holder) |
| Connectivity | Bluetooth (optional) |
| Display | Integrated Touchscreen Interface |
| Compliance | Designed for ISO 2360, ASTM B244, and IEC 61000-4-3 compliant operation |
| Software | On-device measurement management with export to CSV/Excel |
| Key Measurables | Al (5–540 nm), In (24–2700 nm), Cr (24–2600 nm), Ti (102–11080 nm), Cu (3–340 nm), Ag (3–310 nm), Sn (21–2300 nm), Ni (12–1280 nm) |
| Brand | Appo |
|---|---|
| Origin | Switzerland |
| Model | MTA03 |
| Load Range | ±200 mN |
| Load Resolution | 0.5 nN |
| Displacement Range | 0.1 nm to 29 mm |
| Displacement Resolution (short-range) | 0.1 nm |
| Displacement Resolution (long-range) | 1 nm |
| Microscope Working Distance | 95 mm |
| Camera | 3 MP CMOS USB |
| Optical Zoom | 7:1 motorized |
| Illumination Options | Coaxial lens, ring light, diffuse backlight |
| Probe Types | Multiple FT-S microforce sensing probes |
| Optional Modules | FT-G microtweezers for microassembly |
| Brand | ARALAB |
|---|---|
| Model | FITOCLIMA 600 PLH-R / FITOCLIMA 1200 PLH-R |
| Chamber Type | Vertical Upright Environmental Test Chamber |
| Temperature Range | –5 °C to +45 °C (dark), 2 °C to +45 °C (light on) |
| Temperature Uniformity | < ±2.0 °C (light on) |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 40–80 % RH (light on) |
| Humidity Fluctuation | ±0.5 % RH |
| Humidity Uniformity | < ±2 % RH at 4500 Lux, ±5 % RH at full illumination |
| Visible Light Intensity | Up to 26,000 Lux (cold white LED source) |
| Near-UV Irradiance | 30 W/m² (320–400 nm) |
| Light Control Resolution | Adjustable in 1 % increments |
| Illumination Area per Shelf | 0.14 m² |
| Accumulated Light Dose | 1.2 M·Lux (visible, ≤48 h), 200 W·h/m² (near-UV, ≤7 h) |
| Power Supply | 1/N/PE AC 230 V ±10 %, 50 Hz, 16 A |
| Internal Construction | AISI 304 stainless steel |
| External Casing | Powder-coated galvanized steel |
| Insulation | High-density polyurethane foam |
| Controller | ClimaPlus© 7″ color touchscreen interface with non-volatile memory, Ethernet/Wi-Fi/VLAN/VPN connectivity, 32 programmable profiles (24 steps each), password-protected access, built-in data logger (1-year retention), USB export (read-only), real-time diagnostics, alarm history with timestamped event logging, remote monitoring and control via web browser or mobile app |
| Brand | Aralab |
|---|---|
| Model | Fitoterm 150 CTE2 |
| Chamber Type | Vertical Dual-Zone (Hot/Cold) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | –75 °C to +60 °C |
| Transfer Time | ≤ 5 s |
| Test Chamber Dimensions (H×W×D) | 410 × 470 × 650 mm |
| External Dimensions (H×W×D) | 2180 × 950 × 1910 mm |
| Load Capacity | 50 kg |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤ ±1.0 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Heating Rate | 0.2 °C/s |
| Weight | 900 kg |
| Cooling System | Compressor-based, CFC-free |
| Control Interface | 4″ color touchscreen with PLC-based controller |
| Programmability | Up to 50 programs, 50 steps each |
| Data Retention | Non-volatile memory with power-loss recovery |
| Safety | Dual independent PT100 Class A sensors per zone, adjustable high/low temperature limits, audible/visual alarms, heated door with dual-seal locking mechanism |
| Communication | Standard RS232 interface |
| Optional Cooling | Water-cooled (external chiller required) or air-cooled configuration |
| Brand | ARALAB |
|---|---|
| Cabinet Type | Upright Walk-in |
| Humidity Range | 35–90 %RH |
| Temperature Stability | ±0.5 °C |
| Compliance | GMP, FDA 21 CFR Part 11 (audit trail capable), ICH Q1–Q5, WHO TRS 992, EU Annex 15, GSP |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | ASA |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Analog Bandwidth | 10–160 MHz (standard), upgradable to 10–200 MHz |
| Max Sampling Rate | 320 MHz (standard), upgradable to 400 MHz |
| Signal Processing Architecture | Quadrature-based Fourier Transform (FT) with Phase Pulse Detection (PPD) and Adaptive Sampling |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-TK |
| Type | Laboratory Laser Diffraction Particle Analyzer |
| Dispersion Method | Dry & Wet |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Laser Source | Diode-Pumped Solid-State (DPSSL) Laser |
| Wavelength | 532 nm |
| Optical Probe Weight | 2.63 kg (TK1), 2.86 kg (TK2) |
| IP Rating | IP66 |
| Calibration | NIST-Traceable, Single-Calibration-for-Life |
| Signal Processor | ASA2 Advanced Signal Analyzer |
| Software Platform | AIMS (Advanced Imaging & Measurement Suite) |
| Optional Accessories | Anti-Fog Window Shroud, Integrated Thermostatic Heating Module for Sub-Zero/Freezing Environments |
| Brand | AS ONE |
|---|---|
| Model | AD5680 |
| Temperature Range (Internal) | −10 to +50 °C |
| Temperature Range (External Probe) | −50 to +70 °C |
| Relative Humidity Range | 20–100 %RH |
| Display | Simultaneous Temperature (°C), Relative Humidity (%RH), and Real-Time Clock |
| Data Logging | Max/Min Hold Memory |
| Power Supply | Two AA Batteries (Included) |
| Mounting | Wall-Mountable or Desktop-Stable Design |
| External Sensor Cable Length | 3 m (Standard with Model 2-7397-01) |
| Dimensions (W×D×H) | 100 × 25 × 120 mm |
| Weight | 180 g |
| Brand | AS ONE |
|---|---|
| Model | CC-2544-01 |
| Temperature Range | −30 °C to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | ±3–5 %RH (at 23 °C ±2 °C) |
| Humidity Resolution | 1 %RH |
| Data Storage Capacity | 15,000 readings |
| Sampling Interval | 2 s to 24 h adjustable |
| Logging Start Mode | Immediate or Delayed (1–120 s) |
| Alarm Function | Configurable High/Low Thresholds with Visual Indication |
| Display | Dual-line LCD showing real-time temperature/humidity alternately |
| Power | Single AA alkaline battery (typical life ≥12 months at 10-min interval) |
| Weight | 150 g |
| Operating Environment | −30 °C to +70 °C |
| Storage Environment | −50 °C to +90 °C |
| Interface | USB 2.0 |
| Compliance | CE-marked, RoHS-compliant |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model No. | 1-624-01 |
| Instrument Type | Thermo-Hygrometer |
| Minimum Scale | Temperature ±2°C, Humidity ±5% RH |
| Accuracy | Temperature ±2°C |
| Mounting | Wall-Mounted |
| Dimensions | 180 × 180 × 35 mm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Max Load Capacity | 100 kg |
| Frequency Range | 150–300 rpm |
| Stroke Amplitude | 25.4 mm |
| Vibration Mode | Reciprocating (Oscillatory, “Horse-Gallop” Type) |
| Table Dimensions | 1000 × 1100 mm |
| Power Consumption | 1 HP (746 W) |
| Net Weight | 200 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH |
| Input Voltage | AC 220 V (±10%) / 50 Hz or AC 380 V (±10%) / 50 Hz |
| Compliance Standards | EN 71, ANSI Z535, UL 61010-1, ASTM D999, ISTA 3A/3E |
| Brand | Asada |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK3600 |
| Pricing | Available Upon Request |
| Detectable Hole Diameter Range | 0.15–10 mm |
| PCB Size Capacity | 100 × 150 mm to 630 × 650 mm |
| PCB Thickness Range | 0.3–10 mm |
| Max. Hole Count per Board | 150,000 |
| Inspection Speed | 3.5–12.5 m/min (adjustable) |
| Hole Position Repeatability | ±40 µm |
| Hole Dimension Tolerance | ±40 µm |
| Minimum Hole-to-Hole Edge Distance | 0.15 mm |
| Detection Method | Contact Image Sensor (CIS) Proximity Imaging |
| Light Source | Diffuse Long-Strip LED Array |
| Power Supply | AC 220 V, 50 Hz |
| Machine Dimensions (L×W×H) | 3550 × 1200 × 1100 mm |
| Compressed Air Requirement | 0.5–0.7 MPa |
| Weight | 450 kg |
| Brand | ASHMAR SCIENTIFIC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MODEL 110 |
| Pricing | Available Upon Request |
| Brand | ASHMAR SCIENTIFIC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MODEL 110 |
| Pricing | Upon Request |
| Brand | Asida |
|---|---|
| Model | CQ1000 |
| Application | Precision slitting and blanking of uncured fiberglass-reinforced epoxy prepreg (PP) rolls used in PCB and copper-clad laminate (CCL) manufacturing |
| Cutting Principle | Non-contact localized thermal softening followed by mechanical shearing |
| Max. Roll Diameter | 320 mm |
| Cutting Length | 50–750 mm |
| Cutting Width | 200–1270 mm |
| Material Thickness | 0.04–0.3 mm |
| Positioning Accuracy | ±1.0 mm |
| Web Speed | ≤60 m/min |
| Cycle Rate | ≤13 cuts/min (at 500 mm length) |
| Power Supply | 3-phase 5-wire, AC380 V / 50 Hz / ≥40 A |
| Compressed Air | 0.7–1.0 MPa |
| Ambient Requirements | 20 °C ±2 °C, 50 %RH ±5 %RH |
| Footprint | 2600 × 2300 × 1700 mm (L×W×H) |
| Weight | ~1500 kg |
| Avg. Power Consumption | ≤9 kW |
| Compliance | Designed for ISO 9001-aligned production environments |
| Brand | Asida |
|---|---|
| Model | JK3200, JK3600 |
| Detectable Hole Diameter Range | 0.15–10 mm |
| PCB Size Range | 100 × 150 mm to 630 × 650 mm |
| PCB Thickness Range | 0.3–10 mm |
| Max. Hole Count per Board | 150,000 |
| Inspection Speed | 3.5–12.5 m/min (adjustable) |
| Hole Position Repeatability | ±40 µm |
| Hole Dimension Tolerance | ±40 µm |
| Minimum Hole-to-Hole Edge Distance | 0.15 mm |
| Detection Method | CIS Contact Image Sensor (Close-Range Linear Array Imaging) |
| Light Source | Diffuse Long-Strip LED Illumination |
| Power Supply | AC 220 V, 50 Hz |
| Compressed Air Requirement | 0.5–0.7 MPa |
| Dimensions (L×W×H) | 3550 × 1200 × 1100 mm |
| Weight | 450 kg |
| Origin | Guangdong, China |
| Distribution Type | Authorized Distributor |
| Brand | ASIDA |
|---|---|
| Model | ZK2130 |
| Origin | Guangdong, China |
| Type | Domestic |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Accuracy at 50 Ω | ±1% |
| Test Length Range | 0.05–2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.05 Ω |
| Bandwidth | 3 GHz |
| Compliance | IPC-TM-650, IPC-2141 |
| Test Modes | Single-Ended & Differential Impedance, Differential Pair Delay |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-Phase 5-Wire |
| Rated Power | 2.0 kW |
| Operating Ambient Temperature | 2–55 °C |
| Operating Ambient Humidity | 0–85 % RH |
| Compliance | Designed to meet ISO 20653:2013, IPX3/IPX4 rain resistance test requirements for automotive electrical systems |
| Brand | ASLI |
|---|---|
| Model | OK-HAST-25 / OK-HAST-30 / OK-HAST-40 / OK-HAST-50 |
| Internal Chamber Dimensions | Φ25×40 cm / Φ30×50 cm / Φ40×60 cm / Φ50×70 cm |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | Ambient + 0–4 kg/cm² (≈0–392 kPa gauge) |
| Max Continuous Operation | 400 hours |
| Chamber Design Pressure Rating | 2.65 kg/cm² at 140 °C |
| Hydrostatic Test Pressure | 6 kg/cm² |
| Safety Protection | Dual-stage pressure relief (electronic controller + mechanical safety valve) |
| Steam Generation | Independent steam generator chamber |
| Air Purge | Pre-test and in-test cold-air purge function |
| Water Level Monitoring | Immersion-type level sensor with auto-shutdown |
| Door Mechanism | Ergonomic lever-lock system |
| Valve System | High-temperature solenoid valves (dual-circuit configuration) |
| Brand | ASLI |
|---|---|
| Model | OK-ZTH-408 |
| Temperature Range | -55°C to +150°C |
| Temperature Ramp Rate | 15°C/min |
| Vibration Frequency Range | 1–5000 Hz (with PC-controlled option) |
| Vibration Mode | Vertical, Horizontal, or Combined (Vertical + Horizontal) |
| Max. Load Capacity | 50 kg |
| Effective Table Size | 1.0 m × 1.0 m |
| Peak-to-Peak Amplitude | 25.4 mm |
| Speed Display Resolution | 0.1 RPM |
| Drive Motor Power | 1 HP |
| Power Supply | 220 V, 50 Hz |
| Weight | ~300 kg |
| Compliance | GB/T 2423, IEC 60068-2-6 (FC), JJG 189–1997, GB/T 13309–1991, EN, ANSI, UL, ASTM, ISTA Transport Standards |
| Brand | Astera |
|---|---|
| Origin | Guangdong, China |
| Model | XG5120 / XG5130 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current (Software-Limited) | 89 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Geometric Magnification | 12×–48× |
| Repeatability Accuracy | ±40 µm |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| System Dimensions | 2800 × 1550 × 1850 mm |
| Weight | ~2000 kg |
| Power Supply | AC 220 V, 10 A |
| Operating Environment | 22 ± 3 °C, 50 ± 10% RH |
| Computing Platform | 22″ widescreen LCD, Intel Core i3, 2 GB RAM, 500 GB HDD |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Model | D3265 |
| Compliance | ASTM D3265-22 |
| Purity | ≥99.9% ZnO |
| Specific Surface Area | 2.97 m²/g |
| Moisture | 0.09% |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Chamber Material | Imported PVC or FRP (Fiberglass-Reinforced Plastic) |
| Saturated Air Tank | SUS316L Stainless Steel, 1.2 mm Thickness |
| Viewing Window | 8–10 mm Acrylic (PMMA), Impact-Resistant |
| Test Temperature Range | 35°C ±1°C (NSS), 50°C ±1°C (ACSS) |
| Saturated Tank Temp | 47°C ±1°C (NSS), 63°C ±1°C (ACSS) |
| Temperature Uniformity | ≤±2°C |
| Temperature Stability | ≤±0.5°C |
| Spray Rate | 1–2 mL/80 cm²/h (avg. over 16 h) |
| Air Pressure Supply | 1 kg/cm² (two-stage regulation) |
| Control System | Dual PID Digital Controllers (Test Chamber & Saturated Tank), 0.1 s–99.99 h Timer, 0–9999 h Accumulated Time Meter |
| Safety Features | Overload Protection, Over-Temperature Cut-off, Auto-Termination on Time Expiry |
| Brand | ASTR/ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM3300 |
| Price | USD 3,500 (FOB Shanghai) |
| Measurement Range | 1,000–40,000 kJ/kg |
| Accuracy | Relative Standard Deviation ≤0.2% |
| Temperature Resolution | 0.0001 K |
| Test Duration | ~15 min per sample |
| Power Consumption | ≤60 W |
| Dimensions | 650 mm × 390 mm × 450 mm |
| Operating Ambient | 10–35 °C, RH ≤80%, 220 V ±10% AC |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CB11 |
| Quotation | Upon Request |
| Throat Depth | 530 mm |
| Thickness Measurement Range | 0–25 mm |
| Stroke | 25 mm |
| Tabletop Dimensions | 900 × 870 mm |
| Accuracy | ±0.003 mm |
| Display | LCD (mm/inch switchable) |
| Zeroing Function | Arbitrary Position |
| Tabletop Material | Phenolic Resin (Electrical Insulating Board) |
| Power Supply | 220 V AC, 50 Hz / 100 W |
| Net Weight | 120 kg |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Model | XG5 |
| Price Range | USD 70,000 – 140,000 |
| Category | X-ray Radiographic Inspection System for Electronics Assembly |
| Detection Principle | Transmission X-ray Imaging (2.5D) |
| Motion Control | CNC-programmable XYZ-axis movement of X-ray source and image intensifier |
| Image Acquisition | Real-time digital radiography with software-based measurement and pass/fail classification |
| Compliance | Designed to support IPC-A-610, IPC-J-STD-001, and ISO 9001 quality audit workflows |
| Software | Proprietary automated inspection suite with measurement tools (linear distance, circle diameter, concentricity, point-to-center), navigation mapping, and DICOM-compatible image export |