Physical Property Testing Instruments
Filter
Showing 31–60 of 4349 results
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | STB-1225L / STB-1225S |
| Max Load | 2.5 kN |
| Effective Stroke | 850 mm (STB-1225L) / 550 mm (STB-1225S) |
| Crosshead Speed Range | 0.05–1000 mm/min |
| Speed Resolution | 0.01 mm/min |
| Speed Accuracy | ±0.5% |
| Load Accuracy | ±1% of reading (within 1/1 to 1/500 of sensor rated capacity) |
| Auto Range Switching | up to 128× |
| Load Calibration | one-button sensor-integrated calibration with sensor identification |
| Overload Protection | yes |
| Travel Limiters | dual (upper/lower) |
| Dimensions (L×H×W) | 470×1450×335 mm (L) / 470×1050×335 mm (S) |
| Weight | 56 kg (L) / 43 kg (S) |
| Power Supply | AC 100 V, 1Φ, 50/60 Hz, 350 VA |
| Operating Environment | 5–40 °C, 20–80 %RH |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | SV-10 |
| Instrument Type | Oscillatory Viscometer |
| Mounting Style | Benchtop Fixed |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 0.3 mPa·s to 10 Pa·s |
| Temperature Range | 0–160 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1 °C/min |
| Vibration Frequency | 30 Hz |
| Amplitude | 1 mm |
| Repeatability | ±1% of reading (std. dev.) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SV10 / SV-100 |
| Measurement Principle | Sinusoidal fork vibration method (30 Hz) |
| Viscosity Range | SV10: 0.3–10,000 mPa·s |
| SV-100 | 1,000–100,000 mPa·s |
| Repeatability | ±1% of reading (full scale, SD, 20–30 °C, no condensation) |
| Minimum Sample Volume | 35 mL |
| Display | Fluorescent LCD (large-character, high-contrast) |
| Interface | RS-232C standard |
| Temperature Control Option | Compatible with external circulating water bath |
| Software | WinCT-Viscosity (RsVisco) included |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Construction | Titanium-coated vibrating fork sensor (corrosion-resistant, easy-clean) |
| Form Factor | Benchtop fixed-unit system |
| Operating Environment | Ambient temperature (15–35 °C), non-condensing |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4971-E |
| Detection Sensitivity | Fe Ø0.3 mm / SUS Ø0.8 mm |
| Aperture Width | 350 mm |
| Aperture Height Options | 100 mm / 170 mm / 250 mm |
| Through-Height Options | 80 mm / 150 mm / 230 mm |
| Conveyor Belt Width | 250 mm |
| Conveyor Length | 800 mm |
| Display | 7-inch WVGA Color Touchscreen |
| IP Rating | IP65 |
| Communication | Standard Modbus RTU/TCP |
| Data Export | Ethernet + USB (PDF/Chart) |
| Product Memory | 1,000 Recipes |
| Construction | Stainless Steel Frame |
| Drive Mechanism | Direct Gear Drive |
| Brand | A2PS / A2 Photonic Sensors |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | B-POP |
| Pricing | Available Upon Request |
| Brand | ABET Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QE Measurement Systems |
| Pricing | Available Upon Request |
| Light Source | LED-based monochromatic source (DC to high-frequency modulation, no mechanical chopper required) |
| Focal Length | 250 mm |
| Monochromator Drive | Direct-drive grating mechanism |
| Spectral Range | 300–1800 nm |
| Output Coupling | Fiber-coupled, uniform beam profile |
| Detection | Dual-channel lock-in amplifier |
| Device Compatibility | Single-junction and multi-junction photovoltaic devices |
| Measurable Parameters | External Quantum Efficiency (EQE), Incident Photon-to-Current Efficiency (IPCE), Internal Quantum Efficiency (IQE) |
| Bias Voltage Range | ±10 V |
| Current Measurement Range | Up to 100 mA (I–V characterization) |
| Auxiliary Light Source | Optional broadband (white) or custom spectral source |
| Control & Processing | Integrated Windows OS with embedded DSP-based lock-in amplifier |
| Software | Photor™ — full-featured quantum efficiency analysis suite |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Manufactured in Taiwan |
| Model | Abrasion Tester 339 |
| Pricing | Available Upon Request |
| Brand | ABTEC |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A5 |
| Pricing | Available Upon Request |
| THD+N (Typical) | –108 dB |
| Max Input Voltage (Balanced) | 300 Vrms |
| Analog Output Amplitude | 21 Vrms |
| Supported Bluetooth Codecs | SBC, aptX, aptX-LL, aptX-HD, AAC, LHDC (HWA) |
| Digital Interface Options | SPDIF, TOSLINK, AES/EBU, I²S, HDMI, BT, PDM (optional), DSI-O (optional, higher sample rate support) |
| Software API Support | VB.NET, C#.NET, LabVIEW |
| Measurement Capabilities | Level/Gain/Phase, Channel Balance, Frequency Response, THD+N, IMD, SNR, Noise, Crosstalk, Interchannel Phase, DC Level, Frequency Measurement, CMRR, Oscilloscope & Spectrum Monitoring, Stepped Level/Frequency Sweep, DC Level Sweep, Q-Peak Noise |
| Key Features | Internal Chamber Dimensions – Ø250×450 mm (OK-PTC-25) / Ø350×500 mm (OK-PTC-35) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH (saturated steam environment) |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max working pressure 3.0 kg/cm² (safety capacity: 4.0 kg/cm²) |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time | ~30 min (0.0 → 2.0 kg/cm²) |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC cold-rolled steel with electrostatic powder coating |
| Compliance | ASTM D257, DIN 50017, ISO 2231, IEC 60068-2-13, JIS Z 2243, MIL-STD-810H, NACE TM0169, UL 746C |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Key | Internal Chamber Dimensions (PCT-25): Ø250 × 450 mm (D) |
|---|---|
| Internal Chamber Dimensions (PCT-35) | Ø350 × 500 mm (D) |
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 75–100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safety capacity 4.0 kg/cm² |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Control System | Delta color touchscreen PLC (PT-100 sensor), PID-controlled saturated steam temperature & humidity, analog pressure gauge, LED digital timer & temperature display, auto-water replenishment system |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 100–132 °C |
| Humidity Range | 75–100 % RH (Saturated Steam) |
| Pressure Range | 0–200 kPa (gauge), equivalent to 0–2 kg/cm² (gauge) |
| Temp. Uniformity | ±2.0 °C at 100 °C |
| Temp. Fluctuation | ±0.5 °C (unloaded) |
| Humidity Fluctuation | ±3 % RH |
| Ramp Rate | 0.7–1.0 °C/min (unloaded) |
| Temp. Cycling Range | 20–80 °C |
| Time Setting | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Construction | SUS304 Stainless Steel Mirror-Finish Chamber |
| Insulation | High-Density Microglass Wool |
| Cooling System | Hermetic Twin-Stage Refrigeration with Tecumseh (France) Compressor |
| Dual-Door Sealing | Silicone Gasket + Secondary Compression Seal |
| Brand | ACM |
|---|---|
| Origin | Austria |
| Model | LAB.N2 |
| Measurement Range | 0–3 bar |
| Accuracy | ±0.05 bar |
| Repeatability | ±0.02 bar |
| Measurement Time | ≤60 s |
| Data Interface | ACM QUATROL System Integration |
| Power Supply | 24 VDC, 1.5 A |
| Dimensions | Ø32 cm × H56 cm |
| Weight | 8.20 kg |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona 7000 APS |
| Instrument Type | Optical Single-Particle Counter |
| Detection Principle | SPOS (Single Particle Optical Sensing) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles per trillion) |
| Dilution Capability | Auto-dilution up to 10¹¹ #/mL original concentration |
| Regulatory Compliance | FDA 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000 AD |
| Instrument Type | Optical Particle Counter (Single-Particle Optical Sizing, SPOS) |
| Detection Principle | Combined Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for large particle counting (LPC) |
| Compliance | FDA 21 CFR Part 11, cGMP/GLP-ready |
| Software | Embedded audit-trail-enabled control suite with role-based access, electronic signature, and LIMS integration capability |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000 APS |
| Instrument Type | Optical Particle Counter (Light Obscuration / SPOS) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for ≥0.8 µm |
| Max Sample Concentration | 10¹¹ particles/mL (with integrated two-step auto-dilution) |
| Regulatory Compliance | 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Software | Audit-trail enabled, role-based access control, electronic signature, LIMS-compatible |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Acona A7000AD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm |
| Channel Count | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | FDA 21 CFR Part 11, cGMP, GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000APS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024 channels) |
| Sensitivity | 10 ppt (particles per trillion) |
| Max Sample Concentration | 10¹¹ #/mL |
| Compliance | 21 CFR Part 11, USP <729>, ChP 2020 |
| Dilution System | Patented Two-Step Automatic Dilution Module |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000SIS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sizing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Resolution | 0.01 µm |
| Data Channels | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | Acona 7000 SIS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Dual-mode Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Channel Resolution | 1024 channels |
| Size Resolution | 0.01 µm |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona7000APS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single-Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles ≥ 0.8 µm) |
| Max Sample Concentration | 10¹¹ #/mL (with patented two-step auto-dilution) |
| Regulatory Compliance | USP <729>, CP 2020 Vol IV, 21 CFR Part 11, cGMP/GLP-ready |
| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-CYGNUS |
| Instrument Type | Digital |
| Wafer Compatibility | 4" and 6" |
| Ultrasonic Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 2 GHz |
| Bandwidth | 1 GHz |
| XY Repeatability | ±2 µm |
| Z-Scan Range | 70 mm |
| Z-Resolution | 2.5 µm |
| Scan Modes | A-scan, C-scan, T-scan, X-scan (multi-layer C-scan) |
| Integrated Systems | Wafer Map module, BCR reader, Pre-aligner, Spin Coater, Water Jet Scanning, Safety Interlock & Alarm System |
| Motor Drive | High-precision linear servo motors |
| Acoustic Coupling | Water jet coupling |
| Brand | Acoulab |
|---|---|
| Origin | South Korea |
| Model | SAM-DENEB |
| Instrument Type | Digital Scanning Acoustic Microscope |
| Scan Range (X-Y) | 350 mm × 350 mm |
| Spatial Resolution (X-Y) | 0.5 µm |
| Ultrasonic Transducer Frequency Range | 1–500 MHz |
| A/D Sampling Rate | 2 GHz |
| Analog Bandwidth | 1 GHz |
| X-Y Scan Speed | 1000 mm/s |
| X-Y Repeatability | ±0.5 µm |
| Z-Axis Scan Range | 70 mm |
| Z-Axis Resolution | 2.5 µm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Form Factor | PCI Slot-Based Mainframe |
| Channel Capacity | Up to 112 Channels (Configurable via PCI-8 or PCI-2 AE Acquisition Cards) |
| Compliance | Designed for ASTM E1316, ISO 12713, and EN 1330-9 Conformance |
| Interface | PCI Express Backplane with Synchronized Sampling Architecture |
| Power Supply | Industrial-grade 100–240 VAC, 50/60 Hz |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–70 °C |
| Dimensions (W×D×H) | 483 × 500 × 177 mm (Standard 4U Rack-Mount Chassis) |
| Weight | ≤18 kg |
| Brand | Colloidal Dynamics |
|---|---|
| Origin | USA |
| Model | AcoustoSizer II |
| Particle Size Range | 10 nm – 100 µm |
| Zeta Potential Range | 0.5 nm – 30 µm |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.1 °C |
| Ultrasonic Frequency Range | 1–20 MHz |
| Measurement Principle | Multi-frequency electroacoustic spectroscopy & ultrasonic attenuation spectroscopy |
| Sample Concentration Range | 0.1–40% v/v |
| Standard Sample Volume | 85 mL (optional 20 mL) |
| Measurement Time | Real-time, sub-second spectral acquisition per parameter |
| Brand | AcroEdge |
|---|---|
| Origin | Imported (Non-Chinese) |
| Model | AV-10 |
| Measurement Principle | Rotational (Couette flow geometry) |
| Torque Sensing | High-resolution electromagnetic torque transducer |
| Speed Control | Closed-loop DC motor with optical encoder feedback |
| Output Interfaces | RS-485, USB 2.0, Ethernet (TCP/IP), 4–20 mA analog output |
| Alarm Outputs | Dual programmable digital relay (Hi/Lo) |
| Temperature Compensation | Built-in RTD input (PT100 compatible) |
| Enclosure Rating | IP65 (sensor head), IP54 (controller unit) |
| Power Supply | 24 VDC ±10% |
| Operating Temperature | −10 to +60 °C (electronics), −20 to +150 °C (wetted sensor parts) |
| Wetted Materials | 316L stainless steel, Hastelloy C-276 optional |
| Air/N₂ Purge Port | Integrated on probe housing |
| Configuration | Modular — separate sensing probe and remote control unit |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Caisits |
| Price Range | USD 28,000 – 70,000 |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | Curea |
| Excitation Wavelength | 365 nm |
| Spot Diameter | 2 mm |
| Working Distance | 43 mm |
| Measurement Time | 0.1 s |
| Dimensions (W×D×H) | 50×75×125 mm |
| Weight | ~900 g |
| Application | Real-time non-contact UV-curable resin cure monitoring |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU201 |
| Measurement Principle | Laser Displacement + Load Cell-Based Stress Monitoring |
| Temperature Control Range | –50 °C to 300 °C (programmable ramp/soak) |
| Laser Source | 655 nm Class 1 semiconductor diode (220 µW) |
| Displacement Resolution | 2 µm |
| Force Sensing Range | 5 N (standard), optional ranges: 500 mN, 1 N, 2 N, 10 N, 20 N |
| Force Nonlinearity | ±0.5 % RO |
| Force Repeatability | ±0.5 % RO |
| Heating Power | 450 W (3×50 W elements) |
| Cooling Unit Capacity | 450 W (10–25 °C adjustable) |
| Sample Volume | ~1 mL |
| Compliance | ISO 4216:2021, JIS K6941:2019 |
| Key | Brand: AcroEdge |
|---|---|
| Model | Stency |
| Origin | Imported |
| Force Range | 1–20 N (configurable) |
| Force Accuracy | ±0.1% F.S. |
| Displacement Resolution | 0.01 mm |
| Maximum Stroke | 60 mm (uniaxial) |
| Positioning Accuracy | ±0.02 mm |
| Test Speed | 0.1–100 mm/s |
| Data Acquisition Rate | 10 Hz (100 ms interval) |
| Max Data Points per Test | 60,000 |
| Sample Width | up to 50 mm (biaxial), 30 mm (uniaxial) |
| Sample Length | ≥5 mm + gauge length |
| Power Supply | AC 100 V ±10%, 2–3 A |
| Operating Temperature | 0–40 °C |
| Compliance | Designed for ASTM D638, ISO 527, and ISO 11843-compliant tensile evaluation of micro-scale specimens |