Physical Property Testing Instruments
Filter
Showing 751–780 of 4355 results
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKT |
| Temperature Range | -70 °C to +180 °C |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810 |
| Humidity Control | Capacitive Hygrometer + Steam Humidification (MKT models) |
| Refrigerant | R-452A |
| Controller | MCS Touchscreen with Real-Time Clock, Ramp Function, Internal Data Logger |
| Interface | Ethernet, USB, 230 V Socket on Right Side |
| Safety | Optical & Acoustic Fault Diagnostics, Heated Viewing Window with LED Lighting, Silicone-Sealed Access Ports (50 mm for MKT 115/240 |
| Castors | 4, 2 with Brakes |
| Internal Volume | 115 L / 228 L / 734 L (MKT 115 / MKT 240 / MKT 720) |
| Net Weight | 305 kg / 380 kg / 610 kg |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 700 |
| Measurement Range | 1–2000 mN/m |
| Resolution | 0.0001 mN/m (static), 0.001 mN/m (dynamic) |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring, Wilhelmy Plate, Dynamic Contact Angle, CMC, Surface Free Energy, Washburn Penetration, Adhesion Force, Sedimentation, Density |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 701 |
| Measurement Range | 1–2000 mN/m |
| Resolution (Surface Tension) | 0.001 mN/m |
| Accuracy (Surface Tension) | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.05–0.1 µN |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Motorized Stage Speed | 0.01–500 mm/min |
| Stage Positioning Accuracy | 0.016 µm |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Weight | 13–16 kg |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 702ET |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | −20 to +200 °C |
| Temperature Resolution | 0.01 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance | ASTM D971, IEC 62961 |
| Density Measurement Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Sample Stage Speed | 0.01–500 mm/min |
| Positional Accuracy | ±0.26 µm |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Sigma 703D |
| Measurement Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Display Range | −20 to +200 °C |
| Temperature Display Accuracy | ±0.01 °C |
| Measurement Methods | Du Noüy Ring Method, Wilhelmy Plate Method |
| Density Range | 0–2.2 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Force Resolution | 0.1 µN |
| Weight | 11 kg |
| Dimensions (W×D×H) | 33.3 × 24.4 × 62 cm |
| Power Supply | 85–264 VAC, 47–440 Hz, 13 W |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flex |
| Instrument Type | Video-Based Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.01° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | 100 mm × 320 mm |
| Maximum Sample Size (L×W×H) | 763 × 230 × 435 mm |
| Stage Load Capacity | 26 kg |
| Imaging System | USB 3.0 Digital Camera with 8× Zoom, High-Intensity Monochromatic LED Illumination |
| Image Resolution | 1936 × 1216 (optional Theta Flow high-speed camera available) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow with 3D Topography Module |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface Tension Range | 0.01–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited (L) × 100 mm (W) × 320 mm (D) |
| Max Sample Size | Unlimited (L) × 320 mm (W) × 22 mm (H) |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow HPC High Pressure Chamber |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0.1–179.9° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Sample Stage Dimensions | Unlimited × 100 mm × 320 mm |
| Maximum Sample Size | 765 mm × 230 mm × 435 mm |
| Stage Load Capacity | 29 kg |
| Imaging Sensor | 5.3 MP CMOS, 2592 × 2048 pixels |
| Pressure Control | Automated via integrated precision pump |
| Temperature Range | Ambient to elevated temperatures (optional sub-ambient cooling available) |
| Chamber Design | Piston-driven high-pressure cell with corrosion-resistant wetted materials (e.g., Hastelloy C-276, sapphire windows) |
| Fluid Handling | Dual-path intelligent injection valve for direct syringe-based dispensing and in-line cleaning without pump priming |
| Surface Activity Preservation | Piston displacement maintains constant bulk-phase surfactant concentration during pressure ramping |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow |
| Instrument Type | Benchtop Dynamic Contact Angle Analyzer |
| Contact Angle Range | 0–180° |
| Surface/Interfacial Tension Range | 0.01–2000 mN/m |
| Contact Angle Accuracy | ±0.01° |
| Contact Angle Resolution | 2592 × 2048 (5.3 MP) |
| Imaging System | USB 3.0 Digital Camera with 8× Optical Zoom & High-Power Monochromatic LED Illumination |
| Sample Stage Dimensions | 765 mm × 230 mm × 435 mm (W × D × H) |
| Maximum Sample Weight | 29 kg |
| Environmental Monitoring | Integrated Temperature & Humidity Sensors |
| Software Platform | OneAttension v4.x with Audit Trail, CFR 21 Part 11 Compliance Options |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Flow Wafer |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | Contact angle, surface tension, interfacial tension, surface free energy |
| Contact Angle Accuracy | ±0.1° |
| Sample Stage Sizes | 2", 3", 4", 5", 6", 8", 12" wafers |
| Image Resolution | 2592 × 2048 (5.3 MP) |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m (derived via pendant/sessile drop analysis) |
| Maximum Sample Diameter | 12-inch silicon wafer |
| Stage Load Capacity | 500 g |
| Automated Functions | Motorized XYZ translation + programmable rotation (0–360°), four independent software-controlled dispensers with disposable tips |
| Brand | Biolin Scientific |
|---|---|
| Origin | Finland |
| Model | Theta Lite |
| Instrument Type | Benchtop Video Optical Contact Angle Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Contact Angle Accuracy | ±0.1° (standard), ±0.01° (high-precision mode) |
| Surface & Interfacial Tension Range | 0.01–2000 mN/m |
| Surface & Interfacial Tension Accuracy | ±0.1 mN/m (standard), ±0.01 mN/m (high-precision mode) |
| Camera Resolution | 1936 × 1216 pixels |
| Sample Stage Dimensions (L×W×H) | 495 × 130 × 310 mm |
| Max. Sample Weight Capacity | 5 kg |
| Image Magnification | Fixed optical path with high-magnification telecentric lens system |
| Measurement Modes | Static CA, Advancing/Receding CA, Roll-off Angle, Surface Free Energy (Owens-Wendt, Wu, van Oss), Interfacial Tension, Batch Analysis, Roughness-Corrected CA, Single-Fiber CA |
| Software | OneAttension v4.x (FDA 21 CFR Part 11 compliant audit trail option available) |
| Brand | Biuged |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BGD 309 |
| Cupping Punch Diameter | 20 mm |
| Maximum Indentation Depth | 12 mm |
| Depth Resolution | 0.01 mm (via high-precision linear position sensor) |
| Depth Graduation | 0.1 mm |
| Maximum Test Force | 2500 N |
| Specimen Thickness Range | 0.3–1.25 mm |
| Dimensions (L×W×H) | 290 × 240 × 370 mm |
| Net Weight | 28 kg |
| Brand | Biuged |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BGD 310 |
| Price | Upon Request |
| Punch Diameter | 20 mm |
| Maximum Indentation Depth | 18 mm |
| Depth Resolution | 0.01 mm |
| Maximum Punch Force | 2500 N |
| Specimen Thickness Range | 0.3–1.25 mm |
| Specimen Width Capacity | up to 90 mm |
| Stroke Adjustment Range | 0–18 mm |
| Positioning Accuracy | ±0.01 mm |
| Dimensions (L×W×H) | 466 × 322 × 500 mm |
| Net Weight | 52 kg |
| Brand | Biuged |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BGD 545 |
| Price | Upon Request |
| Measurement Principle | Dual-mode electromagnetic (magnetic induction for Fe substrates |
| Measurement Range | 0.0–5000 µm |
| Resolution | 0.1 µm (<100 µm), 1 µm (100–999 µm), 10 µm (>1000 µm) |
| Accuracy | ≤ ±(3% reading + 2 µm) |
| Minimum Substrate Thickness | 0.2 mm (Fe), 0.05 mm (NFe) |
| Minimum Curvature Radius | Convex 5 mm / Concave 25 mm |
| Minimum Measuring Area | 6 mm² |
| Probe Type | Integrated digital probe with sapphire tip |
| Display | 128 × 48 dot-matrix LCD |
| Power Supply | 2 × 1.5 V AAA alkaline batteries |
| Dimensions & Weight | 101 × 62 × 28 mm / 79 g (including batteries) |
| Units | µm and mil selectable |
| Measurement Modes | Fe, NFe, Auto (Fe/NFe) |
| Compliance | GB/T 4956–2003, GB/T 4957–2003, DIN EN ISO 2808, JJG 818–2005 |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | SVO |
| Temperature Range | -70°C to +180°C |
| Max Operating Temperature | +150°C (standard), up to +200°C (optional) |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Pressure Range | Ambient (760 Torr) down to 0.169 Torr (equivalent to ~200,000 ft altitude) |
| Internal Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Heating Method | Immersed electric heater with thermal fluid circulation |
| Vacuum Control | Auto-regulated solenoid valves for precise altitude simulation |
| Controller | Synergy Quattro touchscreen (320×240 color LCD), PID with auto-tuning, dual-channel capability, real-time clock, USB/RS-232/Ethernet (10/100) connectivity |
| Compliance | Designed for ASTM D573, D865, ISO 188, USP <121>, and GLP/GMP-relevant data integrity requirements (audit trail, user access control, electronic signatures via optional software modules) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | WSP |
| Temperature Range | -70°C to 180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | Ambient to 180°C |
| Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm – 1626 mm × 2616 mm × 2515 mm |
| Cold Zone Range | -75°C to 0°C |
| Hot Zone Range | +85°C to +215°C |
| Internal Chamber Volume per Zone | 2.1 ft³ (≈59.5 L) |
| Transfer Time | ≤10 s |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Purge Gas | Dry Nitrogen |
| Defrost Heater | Integrated in Cold Zone |
| Compliance | MIL-STD-202F Method 107G (Conditions A, B, C, F), MIL-STD-883 Method 1010.7 (Conditions A, B, C, F) |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1 |
| Temperature Range | 50–320 °C |
| Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.3, 4.5 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.2 °C/min), ±0.3 °C (at 1.0 °C/min) |
| Temperature Accuracy | ±0.5 °C (<200 °C), ±0.8 °C (≥200 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm |
| Temperature Resolution | 0.1 °C |
| Key | Brand: Boante |
|---|---|
| Model Range | BAT80/150/250/360/460/600-HSW |
| Origin | Hubei, China |
| Temperature Range | 4–60 °C |
| Temp. Uniformity | ±0.5 °C (within chamber) |
| Temp. Stability | ±0.1 °C |
| Humidity Range | 30–90 %RH (at 15–45 °C ambient operating range) |
| Humidity Control Accuracy | ±1 %RH |
| Humidity Fluctuation | ±3 %RH |
| Display | 7-inch capacitive touchscreen |
| Control Algorithm | Adaptive PID |
| Sensor | PT100 platinum resistance thermometer |
| Cooling System | DC inverter-driven refrigeration |
| Air Circulation | Axial-flow micro-circulation fan system |
| Chamber Material | Mirror-finish stainless steel interior with radius-corner design |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutoff, overload protection |
| Optional Interfaces | RS485, USB, thermal printer output, remote monitoring capability |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT80HS-GA |
| Instrument Type | Vertical Chamber |
| Temperature Range | −70 °C to +150 °C (selectable variants: −60 °C, −40 °C, −20 °C, 0–100 °C) |
| Humidity Range | 20–98 %RH |
| Temperature Uniformity | ≤ ±1.5 °C (at same horizontal plane) |
| Temperature Fluctuation | ≤ ±0.5 °C (high-temp segment), ≤ ±1.0 °C (low-temp segment) |
| Humidity Fluctuation | ±3 %RH |
| Heating Rate | ≥2–3 °C/min (non-linear, no-load, ambient to max temp) |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| External Dimensions | 950 × 870 × 1650 mm (W × D × H) |
| Brand | Boante |
|---|---|
| Model | XFY-200I |
| Type | Electromagnetic Vibratory Sieve Analyzer |
| Measurement Range | 0.03–2 mm |
| Max Sample Load | 3 kg |
| Sieve Diameter Options | 76, 100, 150, 200, 203 mm |
| Vibration Frequency | 1–70 Hz |
| Amplitude Control | Auto-adjusting, digitally regulated |
| Drive System | Electromagnetic (3000 cycles/min at 50 Hz) |
| Display | LCD touchscreen interface |
| Timer Range | 0–99 min (1 s resolution) |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 185 W |
| Noise Level | ≤15 dBA (with acoustic enclosure) |
| Net Weight | 35 kg |
| Dimensions (W×D×H) | 300 × 400 × 600 mm |
| Compliance | Designed for ISO 2591-1, ASTM E11, USP <786>, and GLP-compliant laboratory environments |
| Sieve Types Supported | Woven wire mesh (stainless steel), perforated metal plates, electroformed thin-film sieves, nylon mesh |
| Standard Sieves Supplied | 6 pcs |
| Optional Sieves | Up to 10 pcs |
| Operating Modes | Continuous or intermittent vibration (programmable on/off intervals) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bostwick Consistometer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-DNDC |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Paddle-Type |
| Pricing | Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | V-Series Paddle Spindle (V-71 to V-75, including 5×HB variants) |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP-2000+ |
| Temperature Range (L-Series) | 5–75°C |
| Temperature Range (H-Series) | 50–235°C |
| Shear Rate Range | 10–13,300 s⁻¹ |
| Sample Volume | 24–1700 µL (depending on cone geometry) |
| Cone Angles | 1°, 2°, 4° (standard), custom options available |
| Torque Range | High-torque mode up to 2000+ dyne·cm |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Control Interface | Built-in touchscreen + PC via CAPCALC™ software |
| Cone/Plate Gap Adjustment | Motorized auto-gap calibration |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP1000+, CAP2000+ |
| Instrument Type | Rotational Viscometer (Cone-Plate Geometry) |
| Torque Range | High Torque (181,000 dyne·cm) / Low Torque (7,970 dyne·cm) |
| Shear Rate Range | 0.2–15,000 s⁻¹ (dependent on cone spindle and speed selection) |
| Sample Volume | 24–1700 µL |
| Temperature Control | L-Series (5–75°C), H-Series (50–235°C) |
| Display | 4-line LCD |
| Compliance | ASTM D4287, ISO 2884, BS 3900, GB/T 9751 |
| Software | CapCalc32 (PC-based control, data acquisition, rheological modeling) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CAP2000+ |
| Shear Rate Range | up to 12,000 s⁻¹ |
| Viscosity Range | 0.025–10 cP (with 6 spindles) |
| Sample Volume | < 1 mL |
| Temperature Control | Dual integrated systems |
| Display | Digital LCD |
| Data Acquisition | PC-controlled via proprietary software |
| Compliance | ASTM D4287, ISO 2884, BS 3900 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model Series | CAP |
| Instrument Type | Rotational Viscometer |
| Mounting Style | Benchtop (Fixed) |
| Operating Environment | High-Temperature Capable |
| Viscosity Range | 20 – 1,500,000 mPa·s |
| Temperature Range | 5–235 °C |
| Torque Options | High Torque (ICI Standard): 181,000 dyne·cm |
| Low Torque | 7,970 dyne·cm |
| Speed Range | 5–1000 rpm (995 programmable increments) |
| Sample Volume | < 1 mL |
| Temperature Control | Peltier-based (L-Series: 5–75 °C |
| H-Series | 50–235 °C) |
| [Brand | Aerospace Zongheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | CTN-1 |
| Application | Building Materials Flame Retardancy Testing |
| Measurement Object | Non-combustible/Flame-Retardant Building Materials |
| Repeatability Error | ±0.1% |
| Power Supply | AC 220/380 V, 50–60 Hz, ~0.5 kW |
| Airflow Velocity | (0.260 ± 0.026) m/s |
| Airflow Accuracy | ±0.1 m/s |
| Timer Accuracy | <1 s/h |
| Differential Pressure Range | 0–100 Pa |
| Fuel Gas | ≥95% Methane |
| Test Duration | 10 min |
| Combustion Chamber Material | AISI 304 Stainless Steel |
| Dimensions (L×W×H) | 3020 mm × 1020 mm × 3930 mm] |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Dial Viscometer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–8,000,000 mPa·s |
| Torque Accuracy | ±1% of Full Scale |
| Repeatability | ±0.2% of Full Scale |
| Speed Control | Manual Stepwise (0.3–100 rpm, model-dependent) |
| Calibration Traceability | NIST-Traceable Standard Fluids |
| Power Supply | Universal AC Input (100–240 VAC, 50/60 Hz) |
| Warranty | 2-Year Limited |