Physical Property Testing Instruments
Filter
Showing 8251–8280 of 12420 results
| Temperature Range | +100 °C to +132 °C (saturated steam temperature) |
|---|---|
| Humidity | 100% RH (saturated steam) |
| Operating Pressure | 1.5–3.2 kg/cm² (absolute pressure) |
| Time Setting Range | 000–999 hours |
| Pressure Ramp Time | ~45 minutes to reach 1.04 kg/cm² from ambient |
| Temperature Uniformity | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Pressure Stability | ±0.2 kg/cm² |
| Controller | Microprocessor-based PID with PT-100 platinum RTD sensor |
| Safety Features | Interlocked door switch, mechanical safety valve, ABS thermal-insulated door cover, integrated silicone gasket |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,100 (FOB) |
| Inner Chamber Dimensions (cm) | Φ25×35 |
| Temperature Range | 100–132 °C (143 °C optional) |
| Humidity | 100 % RH (saturated steam) |
| Pressure Range | 0.0–4.0 kg/cm² absolute (max safety capacity: 4.0 kg/cm² abs = 1 atm + 3.0 kg/cm² gauge) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.5 °C |
| Chamber Material | SUS316 stainless steel |
| Exterior Material | Powder-coated steel |
| Heating System | Electric immersion heater with thermal cutoff |
| Safety Protections | Dual-stage overtemperature, dual-stage overpressure, emergency mechanical pressure relief, door pressure interlock, water-level alarm & auto-shutdown, heater dry-run protection, humidifier overcurrent protection, manual & automatic pressure release |
| Power Supply | AC 220 V / 50–60 Hz / single-phase OR AC 380 V / 50–60 Hz / three-phase |
| Key | Brand: OEKO Instruments |
|---|---|
| Chamber Dimensions (ID × H) | Φ25×40 cm / Φ30×50 cm / Φ40×60 cm / Φ50×70 cm |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | Ambient + 0–4 kgf/cm² (≈0–392 kPa gauge) |
| Safety Certification | Dual-stage pressure relief, dual overheat protection, water-level sensor auto-refill, 140 °C tank-rated pressure vessel (2.65 MPa hydrostatic test compliance) |
| Max Continuous Operation | 400 hours |
| Steam Generation | Independent steam generator chamber |
| Air Purge | Pre-test and in-process cold-air purge cycle |
| Compliance | Designed for IPC-TM-650 2.6.25, JIS C 5023-4, MIL-STD-202 Method 108, and ISO 16750-4 environmental stress screening protocols |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | 0–4 kgf/cm² (gauge) above atmospheric pressure |
| Internal Dimensions (PCT-25) | Φ25 cm × 40 cm |
| Internal Dimensions (PCT-30) | Φ30 cm × 50 cm |
| Internal Dimensions (PCT-40) | Φ40 cm × 60 cm |
| Internal Dimensions (PCT-50) | Φ50 cm × 70 cm |
| Sealing System | Patented dual-contact gasket design |
| Safety Systems | Dual-circuit high-temp solenoid valve, overpressure/overtemperature cut-off, mechanical anti-opening door lock, manual & automatic pressure release |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pressure Range | 0–4 kgf/cm² above atmospheric pressure (0–392 kPa gauge) |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100% RH saturated steam |
| Internal Chamber Dimensions (D×H, cm) | Φ25×40 |
| Temperature Control Accuracy | ±0.1 °C (PID-controlled digital controller) |
| Safety Features | Dual overheat protection, mechanical safety valve, interlocked door switch, auto-water replenishment, condensate purge system, ABS insulated door cover, integrated silicone door gasket |
| Brand | OEM / Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Pricing | USD 3,950–6,800 (FOB) |
| Internal Dimensions (W×H×D) | Ø250×300 mm / Ø350×400 mm / Ø450×500 mm / Ø650×600 mm |
| Chamber Material | ASTM A240 Type 316 Stainless Steel |
| External Casing | Powder-coated or 304 stainless steel |
| Temperature Range | +10°C to 132°C (optional 147°C custom calibration) |
| Pressure Range | 0–2.5 kg/cm² gauge (0–35.5 psi), max absolute pressure 3.5 kg/cm² |
| Heating Method | Immersed electric heating elements |
| Humidification | Direct steam generation via electric heater |
| Water Replenishment | Stainless steel float valve system |
| Cycle Control | LED digital timer with temperature-triggered start (ASTM E2035-compliant timing logic) |
| Safety Interlocks | Dual mechanical pressure lock, overpressure relief valve (ASME BPVC Section VIII compliant), door-seal integrity verification prior to pressurization |
| Power Supply | 220–240 VAC, 50/60 Hz, single-phase |
| Thermal Stability | ±0.5°C at setpoint (121°C) |
| Circulation | Natural convection steam atmosphere |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-III-X |
| Price Range | USD 1,400–7,200 (FOB) |
| Temperature Range (°C) | -30 to 1700 (selectable configurations) |
| Heating Rate (°C/min) | 0.1–20 (standard setpoint: 5) |
| Temperature Accuracy (°C) | ±1 |
| Sample Diameter (mm) | 5–10 |
| Sample Length (mm) | ≤50 |
| Measurement Range | 5 mm |
| Resolution | 1 µm (optional 0.1 µm digitization) |
| Atmosphere Options | Air, Vacuum (down to 10⁻¹ mbar), Static/Dynamic Inert (N₂, Ar), Reactive Gas (customizable) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PCY-SP |
| Pricing | Available Upon Request |
| Max Operating Temperature | 1000 °C (1200 °C Furnace Limit) |
| Temperature Control | Dual K-Type Thermocouples (Control + Sample Sensing) |
| Control System | Intelligent PID with Programmable Ramp Rates & Segmented Profiles |
| Temperature Accuracy | ±1 °C |
| Heating Element | Ni–Cr (2080) Resistance Wire (Theoretical Max: 1350 °C) |
| Displacement Detection | Optical Grating-Based Linear Encoder |
| Displacement Accuracy | ±0.5% FS |
| Data Acquisition | Real-Time PC-Based System |
| Software Platform | Windows 7/XP Compatible (Bilingual UI), ASTM C338–Compliant Workflow & Reporting Engine |
| Origin | Japan |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PEANUTS |
| Price | Upon Request |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-NS01 |
| Ignition Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Burner Inner Diameter | 9.5 ± 0.5 mm, Length: ~100 mm |
| Adjustable Flame Height | 20–100 mm |
| Flame Application Time Range | 0–99 min 99 sec |
| Chamber Volume | 0.05 m³ |
| Chamber Material | Stainless Steel or Powder-Coated Steel |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Compliance | GB 8410–2006, FMVSS 302, ISO 3795, ASTM D5132 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TG-GC/MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Manufacturer Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | TG-hiden MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-IR |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PerkinElmer TG-IR-GC/MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | Controls (Europe) |
|---|---|
| Origin | Germany |
| Model | PermeaTORR AC+ |
| Power Supply | 24 Vdc / 3 Adc |
| Weight (pump + case) | 10 kg |
| Data Storage | ≥1000 test records (internal microSD) |
| Interface | Touchscreen display + Bluetooth-enabled mobile remote control |
| Vacuum Source | Integrated oil-free miniature vacuum pump |
| Hose Length | Fixed-length flexible hose up to 5 m |
| Compliance | GB/T 50082–2024, SIA 261/1:2019, ASTM C1202, EN 12390-8, Cembureau O₂ permeability protocol |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 68-76 PGX+ |
| Quotation | Upon Request |
| Camera Resolution | 640 × 480 px |
| Frame Rate | 80 fps |
| Minimum Dispensed Volume | 0.5 µL |
| Contact Angle Range | 5°–180° |
| Accuracy | ±1° |
| Dimensions (L×W×H) | 90 × 55 × 90 mm |
| Compliance Standards | TAPPI T458, ASTM D-724, ASTM D-5946, GB/T 30447 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PH |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Upright |
| Temperature Range | −70 °C to +180 °C |
| Humidity Range | 5–98 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Uniformity | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Temperature Resolution | 0.1 °C |
| Humidity Resolution | 0.1 % RH |
| Temperature Control Accuracy | ±0.3 °C |
| Humidity Control Accuracy | ±3 % RH |
| Internal Dimensions (typical) | W500 × H600 × D400 mm |
| External Dimensions (typical) | W1070 × H900 × D650 mm |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PH-80 |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Upright Benchtop Chamber |
| Temperature Range | −70 °C to +180 °C |
| Humidity Range | 20–98 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Uniformity | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Internal Dimensions (W×H×D) | 400 × 500 × 400 mm |
| External Dimensions (W×H×D) | 970 × 800 × 650 mm |
| Temperature Resolution | 0.1 °C |
| Humidity Resolution | 0.1 % RH |
| Temperature Control Accuracy | ±0.3 °C |
| Humidity Control Accuracy | ±3 % RH |
| Temperature Distribution Uniformity | ±1 °C |
| Humidity Distribution Uniformity | ±3 % RH |
| Heating Time (30 °C → 100 °C) | Approx. 70 min |
| Cooling Time (40 °C → 0 °C) | Approx. 45 min |
| Cooling Time (60 °C → −20 °C) | Approx. 90 min |