| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Maximum Output Voltage | 100 kV |
| Compliance Standards | IEC 60243-1, ASTM D149, GB/T 1408.1, ISO 60243 |
| Voltage Regulation Accuracy | ±1% of full scale |
| Rise Rate Control | Adjustable from 0.1 to 5.0 kV/s (linear or stepwise) |
| Current Detection Range | 0.1 μA to 100 mA |
| Electrode Alignment Tolerance | ≤0.1 mm |
| Safety Certification | IEC 61010-1, CAT III 1000 V |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-100KV |
| Breakdown Voltage Range | 0–100 kV (AC/DC) |
| Voltage Accuracy | ≤1% |
| Test Media | Air or Insulating Oil |
| Electrode Options | 25 mm, 75 mm, 6 mm (spherical, disk, rod configurations) |
| Power Capacity | 5 kVA or 10 kVA |
| Rise Rate | 10 V/s – 5 kV/s (continuously adjustable) |
| Safety Protection | 9-level interlocked protection system |
| Compliance | GB/T 1408.1–2006, GB/T 1695–2005, GB/T 3333–1999, ASTM D149, ASTM D3755, IEC 60243-1 |
| Dimensions (Standard) | 700 × 800 × 1300 mm (L×W×H), 100 kg |
| Dimensions (Large) | 1900 × 1300 × 1700 mm (L×W×H), 200 kg |
| Input Voltage | 220 V AC, 50/60 Hz |
| Maximum Hold Time | 8 hours |
| Data Interface | Optical-isolated acquisition, Bluetooth remote control |
| Software | Windows-based test management with real-time curve plotting, audit trail, export to Excel/Word, user access control, and GLP-compliant reporting |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Output Voltage | AC/DC 0–150 kV |
| Measurement Range | AC/DC 15–150 kV |
| Accuracy | ≤ ±2% |
| Ramp Rate | 1–5 kV/s |
| Hold Time | 0–4 h |
| Leakage Current Setting | 1–30 mA (software-controlled) |
| Input Power | AC 220 V ±10%, 50 Hz ±1% |
| Output Power | 15 kVA |
| Dimensions (L×W×H) | 1980 × 1220 × 1750 mm |
| Weight | 350 kg |
| Operating Environment | 15–30 °C, RH ≤ 85% |
| Grounding Requirement | Dedicated earth electrode ≥1.5 m depth |
| Compliance | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, GB/T 3333, HG/T 3330, GB 12656, ASTM D149 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Output Voltage | AC/DC 0–150 kV |
| Measurement Range | AC/DC 15–150 kV |
| Accuracy | ≤1% |
| Ramp Rate | 0.01–5 kV/s |
| Hold Time | 0–8 h |
| Leakage Current Setting | 1–30 mA |
| Input | AC 220 V ±10%, 50 Hz ±1% |
| Power Output | 15 kVA |
| Dimensions (L×W×H) | 1980 × 1220 × 1750 mm |
| Weight | 350 kg |
| Environmental Operating Range | 15–30 °C, RH ≤85% |
| Grounding Requirement | Dedicated earth electrode ≥1.5 m depth |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV |
| Voltage Ramp Rate | 0.1–3 kV/s (adjustable) |
| Electrode Configuration | 12.5 mm polished spherical electrodes (Ra ≤ 0.2 µm), fixed gap 2.5 mm ± 0.05 mm |
| Breakdown Current Threshold | 1–100 mA (programmable), response time ≤ 10 µs |
| Temperature Control | Integrated oil bath, stability ±1 °C at 25 °C |
| Humidity Limit | <70 % RH in test chamber |
| Compliance | IEC 60156, ASTM D877, GB/T 507, GB 2536 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Range | 0–100 kV AC/DC |
| Ramp Rate | 0.05–10 kV/s (continuously adjustable) |
| Measurement Accuracy | ≤1% for AC/DC voltage |
| Output Ripple Factor | ≤2% |
| Test Duration | 0–48 h (current-free mode) |
| Oil Bath Temperature Range | Ambient to 300 °C |
| Electrode Configurations | φ25 mm & φ75 mm stainless steel electrodes |
| Power Rating | 10 kW |
| Dimensions (L×W×H) | 1600 × 1100 × 1500 mm |
| Working Height | 940 ± 30 mm |
| Work Surface | 1600 × 1100 mm |
| Overcurrent Protection | 1–100 mA |
| Sampling Capacitor | 100 pF / 100 kV |
| Interface | Bilingual (English/Chinese) touchscreen + PC-based control software |
| Safety Compliance | IEC 61010-1, IEC 60243-1, GB/T 1408.1, ASTM D149, ISO 60243-1 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV AC/DC |
| Voltage Accuracy | ≤ ±3–5% |
| Adjustable Ramp Rates | 0.1–5 kV/s (7 preset steps) |
| Test Modes | AC/DC — Uniform Ramp, Stepwise Ramp, Hold-at-Voltage (Dielectric Withstand) |
| Compliance | GB 1408.1–2006, GB/T 1695–2005, GB/T 3333–2008, HG/T 3330–2003, GB 12656–1990, ASTM D149–2022 |
| Electrode Configurations | Ø25 mm & Ø75 mm stainless steel disk electrodes |
| Test Medium | Air or insulating oil |
| Safety Interlocks | 6-level hardware-enforced shutdown (door switch, key-controlled HV disconnect, zero-position lockout, overcurrent cutoff <100 ms, ground fault detection, DC discharge alarm) |
| Software Platform | Windows XP/7/8 native application with real-time curve plotting, multi-curve overlay, region zoom, manual data validation, Excel export, user role management, and audit-trail-capable test logging |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Maximum Output Voltage | 150 kV |
| Compliance | GB/T 1408.1–2016, IEC 60243-1:2013, ASTM D149–20 |
| Electrode Configurations | Cylindrical (6.4 mm & 25 mm diameter), Parallel-plate, Needle-to-plate |
| Voltage Ramp Rates | 0.5–2 kV/s (adjustable) |
| Sample Thickness Range | 0.1–3 mm |
| Environmental Control | 23 ± 2 °C, 50 ± 5 % RH (optional oil bath or SF₆ gas chamber) |
| Safety Standards | IEC 61010-1, Dual Grounding, Interlocked Enclosure, Emergency Stop |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-150KV |
| Breakdown Voltage Range | 0–150 kV AC/DC |
| Voltage Accuracy | ≤2% |
| Rise Rate | 0.1–10 kV/s |
| Output Power | 5–10 kVA |
| Test Medium | Insulating oil or air |
| Electrode Options | 25 mm & 75 mm disc, 6 mm sphere, parallel-plate, cylindrical, conical, wire-type |
| Safety Protection | Nine-level interlock system (including door interlock, overcurrent cutoff <0.1 s, grounding monitoring ≤4 Ω, discharge circuitry) |
| Compliance | GB/T 1408.1–2006, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149–2022 |
| Operating Environment | 15–30 °C, 30–85% RH |
| Dimensions (L×W×H) | 700×800×1300 mm or 1900×1300×1700 mm |
| Weight | 100–200 kg |
| Warranty | 3 years full coverage, lifetime technical support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Breakdown Voltage Range | 0–50 kV AC / DC |
| Voltage Accuracy | ≤1% |
| Test Medium | Air or Insulating Oil |
| Electrode Options | 25 mm, 75 mm, 6 mm spherical/plate electrodes |
| Ramp Rate | 0.1–3 kV/s (adjustable, continuous) |
| Test Modes | Stepwise ramp, constant-rate ramp, withstand voltage (0–6 h), gradient testing |
| Safety Protection | 9-level interlock system (overvoltage, overcurrent, short-circuit, door interlock, zero-voltage reset, post-test discharge, grounding, software lockout, electromagnetic discharge) |
| Power Input | 220 V AC, 5 kVA |
| Dimensions | 700 × 800 × 1300 mm (L×W×H) |
| Weight | ~150 kg |
| Compliance | GB/T 1408.1–2016, GB/T 1695–2005, GB/T 3333–1999, HG/T 3330, GB/T 12656–1990, ASTM D149, ASTM D3755 |
| Software | PC-based control with real-time curve plotting, data logging, audit trail, Excel/Word export, user access control, and GLP-compliant test report generation |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Maximum Output Voltage | 50 kV |
| Compliance | IEC 60243-2, GB/T 1408.2 |
| Voltage Resolution | 0.1 kV |
| Ramp Rate Range | 0.1–5 kV/s (continuously adjustable) |
| Trip Current Threshold | 1–100 mA |
| Electrode Options | IEC-standard spherical/cylindrical electrodes (6 mm or 25 mm diameter) |
| Environmental Control | 23 ± 2 °C, 50 ± 5 % RH |
| Measurement Accuracy | ±1 % of reading (voltage) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Maximum Output Voltage | 50 kV AC/DC |
| Voltage Measurement Range | 0–50 kV (AC/DC) |
| Power Capacity | 5 kVA |
| Rising Rate | 0.1–5 kV/s |
| Voltage Measurement Accuracy | ≤1% |
| Test Modes | Ramp-up, Step-up, and Hold-at-Voltage (Dielectric Withstand) |
| Safety Protections | Nine-level interlock system including overvoltage cutoff, overcurrent trip, short-circuit detection, safety door interlock, zero-voltage reset, post-test automatic discharge (electromagnetic + resistive), independent grounding, and software operation validation |
| Dimensions (L×W×H) | 1200 × 1050 × 1500 mm |
| Net Weight | ~200 kg |
| Compliance | GB/T 1408.1–2016, GB/T 1408.2–2016, GB/T 1695–2005, GB/T 507–2002, DL 429.9–1991, ASTM D149–2022 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50KV |
| Breakdown Voltage | 50 kV |
| Voltage Accuracy | ≤2% |
| Ramp Rate | 10 V/s – 5 kV/s |
| Test Modes | AC/DC, Stepwise, Withstand, Ramp-to-Failure |
| Test Media | Air or Insulating Oil |
| Electrode Options | 6 mm, 25 mm, 75 mm diameter |
| Power Rating | 5 kVA |
| Safety Protection | 9-Level Interlocked Protection |
| Compliance | GB/T 1408.1–2006, GB/T 1408.2–2006, GB/T 1695–2005, ASTM D149 |
| Software | PC-based Control with Real-Time Curve Plotting, Data Logging, Audit Trail, and Multi-Sample Batch Testing |
| Dimensions (L×W×H) | 700×800×1300 mm / 1900×1300×1700 mm |
| Weight | 100 kg / 200 kg |
| Warranty | 3 Years Full Coverage, Lifetime Technical Support |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Dielectric Breakdown Voltage Range | 0–50 kV |
| Input Power | AC 220 V ±10%, 50 Hz |
| Max Output Power | 3 kVA |
| Rise Rate Adjustment | 0.1–5 kV/s (adjustable) |
| Leakage Current Alarm Threshold | Adjustable (0.1–20 mA) |
| Voltage Accuracy | ±1.5% of reading (calibrated annually) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Grounding Resistance Requirement | ≤4 Ω |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Dielectric Breakdown Voltage | 50 kV |
| Compliance | GB/T 1408.1, IEC 60243-1, ASTM D149 |
| Voltage Type | AC/DC selectable |
| Electrode Configuration | Standard spherical/cylindrical electrodes (brass) |
| Safety Enclosure | Interlocked grounded test chamber with emergency stop |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Breakdown Voltage Range | 0–50 kV (AC/DC) |
| Compliance | IEC 60243, ASTM D149, GB/T 1408, GB 16935 |
| Safety Features | Overvoltage/overcurrent protection, automatic discharge, interlocked enclosure |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Maximum Output Voltage | 50 kV |
| Voltage Regulation Range | 0–50 kV AC/DC |
| Ramp Rate | 0.1–5 kV/s (adjustable) |
| Breakdown Detection | Dual-threshold (current ≥1–10 mA + voltage drop >10%) |
| Compliance | IEC 60243-1, ASTM D149, GB/T 1408.1 |
| Safety Enclosure | 1.5 mm 304 stainless steel shielded chamber (≥60 dB shielding effectiveness) |
| Data Acquisition | 100 kHz sampling rate |
| Environmental Compensation | Real-time temperature/humidity correction (0.5%/°C) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJC-50kV |
| Maximum Output Voltage | 50 kV |
| Compliance | IEC 60243, ASTM D149, IEC 60156, GB/T 13542 |
| Electrode Configurations | Sphere-Plate (Φ6 mm sphere vs. 25 mm plate) and Three-Electrode System |
| Temperature Control | 23 ± 2 °C |
| Relative Humidity Control | 50 ± 5 % RH |
| Voltage Waveform | 50 Hz AC sine wave (THD ≤ 5 %) or DC (ripple ≤ 3 %) |
| Safety Enclosure | Explosion-resistant viewing window rated ≥ 75 kV |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ZJD-87 Dielectric Constant and Dissipation Factor Analyzer |
| Price Range | USD 11,200 – 21,000 (FOB Beijing) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJD-87 |
| Price Range | USD 7,000 – 14,000 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-A Dielectric Constant and Dissipation Factor Analyzer |
| Frequency Range | 10 kHz – 60 MHz (DDS Synthesized) |
| Capacitance Tuning Range | 30–500 pF |
| Q Factor Range | 1–1000 |
| Q Resolution | 0.1 (4-digit effective) |
| Q Measurement Accuracy | < ±5% |
| Inductance Measurement Range | 15 nH – 8.4 H |
| Inductance Resolution | 0.1 nH |
| Inductance Accuracy | < ±5% |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit display) |
| Frequency Coverage Ratio | 6000:1 |
| Standard Compliance | GB/T 1409, IEC 60250, JB 7770 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | ZJD-A Dielectric Constant and Impedance Analyzer |
| Frequency Range | 10 kHz – 70 MHz (DDS Synthesized) |
| Q Factor Range | 1–1000 (Auto/Manual Scaling) |
| Q Resolution | 0.1 (4-digit display) |
| Frequency Accuracy | ±3×10⁻⁵ ±1 digit (6-digit precision) |
| Inductance Measurement Range | 15 nH – 8.4 H |
| Capacitance Tuning Range | 30–500 pF |
| Capacitance Resolution & Error | ±1.5 pF or <1% |
| tanδ Measurement Capability | Yes |
| εᵣ (Relative Permittivity) Calculation | Supported via parallel-plate fixture |
| Fixture Electrode Diameter | Φ50 mm / Φ38 mm (selectable) |
| Electrode Spacing Adjustment | ≥15 mm |
| Micrometer Resolution | 0.001 mm |
| Fixture Loss Tangent (1 MHz) | ≤4×10⁻⁴ |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-A |
| Frequency Range | 10 kHz – 110 MHz |
| Q Measurement Range | 1–1000 |
| Tanδ Accuracy | 1×10⁻⁴ |
| εr Accuracy | 0.001 |
| Electrode Diameter | Φ38 mm or Φ50 mm (selectable) |
| Electrode Spacing Adjustment | ≥15 mm |
| Sample Thickness Range | 0.1–10 mm |
| Residual tanδ of Fixture | ≤4×10⁻⁴ @ 1 MHz |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Operating Temperature | 0–40 °C |
| Power Consumption | ~25 W |
| Compliance | GB/T 1409–2006, GB/T 1693–2007, ASTM D150–11, IEC 60250 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZJD-B |
| Price Range | USD 4,200 – 11,200 (FOB Beijing) |
| Frequency Range | 1 kHz – 1 GHz (standard) |
| Dielectric Constant (ε′) Range | 1.0 – 35.0 (resolution: 0.1%) |
| Loss Tangent (tan δ) Range | 1×10⁻⁵ – 1.0 (resolution: 1×10⁻⁵) |
| Sample Compatibility | Solid discs (Ø20–100 mm, thickness 0.1–10 mm), liquids (parallel-plate or coaxial probe), thin films (3-electrode configuration) |
| Temperature Range | Ambient (23 °C ±1 °C) |
| optional thermal chamber | −50 °C to +150 °C |
| Voltage Gradient | 10–500 V/mm (adjustable per sample thickness) |
| Compliance | IEC 60250:2020, ASTM D150-18, GB/T 1409-2006 |
| Calibration | Open/short/load with NIST-traceable polystyrene reference dielectric and certified standard capacitors |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 50 Hz – 1 MHz |
| Test Voltage | 0.1 kV – 10 kV |
| Temperature Control | Ambient to 300 °C |
| Sample Compatibility | Solid discs (Ø25–100 mm, thickness 0.1–10 mm), liquids, thin films |
| Measurement Accuracy | ε ≤ ±1%, tanδ ≤ ±1×10⁻⁴ |
| Compliance | IEC 60250, ASTM D150, GB/T 1409, IEEE 286 |
| Calibration | CNAS-accredited traceability |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 100 kHz – 160 MHz |
| Q Factor Range | 1–1023 |
| Capacitance Measurement | 1 pF – 25 nF |
| Inductance Measurement | 1 nH – 140 mH |
| Main Tuning Capacitor Range | 17–240 pF |
| Accuracy | ±1 pF (≤150 pF), ±1% (>150 pF) |
| Signal Source | DDS Synthesized, Stability ±3×10⁻⁵ ±1 digit |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Operating Temperature | 0–40 °C |
| S916 Dielectric Test Fixture | Parallel-plate Electrodes (Φ38 mm), Gap Adjustment ≥15 mm, Resolution 0.001 mm, tanδ ≤4×10⁻⁴ @ 1 MHz |
| LKI-1 Inductor Set | 10 Standard Inductors (0.05 μH to 10 mH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZRS-2 |
| Temperature Range | 500–1000 °C ±2 °C |
| Glow-Wire Duration | 0–999.9 s ±0.1 s |
| Ignition Time & Flame-Out Time Measurement | 0–999.9 s ±0.1 s |
| Thermocouple | Φ0.5 mm K-type armored |
| Glow-Wire Material | Ni80/Cr20 alloy wire, Φ4 mm |
| Penetration Depth | 7 mm ±0.5 mm |
| Applied Force | 1.0 N ±0.2 N |
| Actuation Speed | 14 mm/s |
| Repeatability Error | ≤1% |
| Compliance | GB/T 5169.10–2017, GB 4706.1, IEC 60695-2-10/11/12/13 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (adjustable) |
| Accuracy | ±1% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | 4.5 kg |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (±10%) |
| Accuracy | ±1% (up to 10¹⁰ Ω), ±5% + 2 digits (10¹¹–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Display | Full-digit LCD, simultaneous resistance and current readout |
| Dimensions | 300 mm × 280 mm × 150 mm |
| Weight | ~3.0 kg |
| Power | AC 220 V, 50 Hz, ~10 W |
| Operating Environment | –10 °C to 50 °C, RH < 90% |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Display | Digital LCD |
| Accuracy | ±1% |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006, GB/T 22042–2008, EN 1149-1:1995, FZ/T 64013–2008, SJ/T 10694–2006 |