Physical Property Testing Instruments
Filter
Showing 181–210 of 12188 results
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZK2130 |
| Pricing | Upon Request |
| Brand | Aist ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM6100 |
| Measurement Principle | X-ray transmission attenuation (dual-energy correction capable) |
| Measuring Range | 0.1–4.0 mm (steel), 0.01–10.0 mm (aluminum) |
| Accuracy | ±0.2% |
| Resolution | 0.001 mm |
| Response Time | 100 ms (63% to 5% thickness step) |
| Sampling Interval | 200/400/600/800 ms selectable |
| Repeatability | 0.2% |
| Long-term Drift | <±0.24% per 8 h |
| Preheat Time | 1 h |
| Auto-calibration Time | ≤20 min |
| Operating Temp. | 0–40 °C |
| Humidity | ≤95% RH at 30 °C |
| Power Supply | 220 V ±20 V, 50 Hz |
| Power Consumption | ≤250 W |
| Dimensions (Operator Console) | 470 × 365 × 160 mm, 15 kg |
| C-frame Dimensions | 673 × 579 × 189 mm, 35 kg |
| Radiation Safety | Fully shielded |
| Regulatory Certification | CMC (Shanghai) No. 沪制02280027 |
| Brand | Aiyao Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PCA |
| Pricing | Available Upon Request |
| Brand | Aiyao Instruments |
|---|---|
| Model | TCT |
| Measurement Principle | 3ω Method |
| Sample Form | Micro/Nano Thin Films (Supported & Freestanding) |
| Temperature Range | Ambient to 400 °C (Optional Cryogenic Extension Available) |
| Thermal Conductivity Range | 0.1–1000 W/(m·K) |
| Resolution | <0.5% of Full Scale |
| Data Acquisition | High-Precision Digital Source Meter + Dual-Phase Lock-in Amplifier |
| Compliance | ASTM E1461, ISO 22007-2 (Adapted), GLP-Compatible Audit Trail Logging |
| Brand | Aiyao Instruments |
|---|---|
| Model | TEA |
| Measurement Principle | Optical Interferometry |
| Sample Type | Transparent Bulk & Thin-Film Materials |
| Heating Method | IR Heater with PID + Fuzzy Logic Control |
| Temperature Control Mode | Programmable Ramp & Isothermal Hold |
| Vacuum Port | Yes |
| Cooling Interface | Water-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection |
| Origin | Hubei, China |
| Distributor Type | Authorized Domestic Distributor |
| Compliance | Designed for ISO 11359-2 and ASTM E228 Conformance Context |
| Brand | Akrometrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AXP |
| Pricing | Available Upon Request |
| Brand | Akrometrix |
|---|---|
| Origin | USA |
| Model | Customized |
| Sample Size Range | 0.5 mm × 0.5 mm to 400 mm × 400 mm |
| Warpage Resolution | <1 µm |
| Data Acquisition Density | 1.4 million points per 2 seconds |
| Temperature Control | IR heating + convection cooling |
| Temp Range | −50 °C to 300 °C |
| Reflow Simulation Support | up to 300 °C |
| Brand | Akrometrix |
|---|---|
| Origin | USA |
| Model | TTSM |
| Measurement Principle | Non-contact shadow moiré interferometry |
| Temperature Range | Ambient to 300 °C (optional -50 °C to 300 °C) |
| Z-axis Resolution | ≤1.25 µm (AKM600P variant) |
| Field of View | Up to 600 mm × 600 mm (AKM600P), 48 mm × 64 mm (DFP), 70 mm circular (CRE) |
| Data Acquisition Speed | <2 s per full-field measurement (up to 1.4 million data points) |
| Compliance | JEDEC JESD22-B112, JEITA ED-7306, IPC TM-650 2.4.22 (Bow & Twist), IPC-9641, ASTM E2923 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | HY-763 |
| Price | Upon Request |
| Abrasion Standard Compliance | GB/T 1689, BS 903-A9, CNS 734 |
| Wheel Dimensions | Ø150 × 25 mm (36# grit) or Ø150 × 38 mm (40# grit) |
| Applied Load | 27.5 N (standard), configurable |
| Rotational Speed | 76 ± 2 rpm |
| Counter | LCD, 0–999,999 cycles |
| Specimen Tilt Angle | 0°–45° adjustable |
| Calibration Certificate | CNAS-accredited calibration report included |
| Brand | AKTS |
|---|---|
| Origin | Switzerland |
| Model | CALISTO Thermal Kinetics Software |
| Software Modules | CALISTO Acquisition (instrument control for SETARAM systems) & CALISTO Processing (vendor-agnostic data analysis) |
| Compliance | Designed for GLP/GMP environments with audit trail readiness |
| Data Handling | Supports DSC, TGA, and calorimetry datasets from multiple manufacturers |
| Key Mathematical Capabilities | Heat capacity determination, peak deconvolution, inverse filtering, glass transition analysis, decay modeling, custom equation fitting, advanced baseline construction, solid/liquid ratio calculation, reaction kinetics profiling, baseline subtraction, normalization, numerical integration, TMA alpha-point extraction (true α, mean α), temperature calibration correction, mass loss quantification, tare compensation, derivative computation (with configurable filter types), Gaussian & Savitzky–Golay filtering, curve segmentation, slope correction, natural logarithm transformation, inflection point detection, spike removal |
| Output Formats | Native .cali project files, export to PDF, PNG, SVG, CSV, and Word-compatible vector graphics (auto-resized for optimal print/display resolution) |
| Brand | AKTS |
|---|---|
| Origin | Switzerland |
| Model | ThermoKinetics Software Suite |
| Application | Kinetic Analysis of Thermal Data (DSC, DTA, TGA, TG-MS, TG-FTIR) |
| Compliance | ASTM E698, ISO 11358, USP <1031>, ICH Q5C, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Deployment | Windows-based standalone application with optional network license server support |
| Data Import | Native support for NETZSCH, TA Instruments, SETARAM, PerkinElmer, Mettler Toledo, Hitachi thermal analyzers |
| Brand | AOLONG |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AL-CT1020 |
| X-ray Tube Voltage | 20–225 kV |
| Target Type | Reflection Anode |
| Max. Tube Power | 320 W |
| Max. Target Power | 280 W |
| Source-to-Object Minimum Distance | 4 mm |
| Spatial Resolution (JIMA) | 2 µm |
| Number of Axes | 5 |
| Brand | ALISN |
|---|---|
| Model | MTN-150 |
| Type | Mold-Specific Environmental Test Chamber |
| Control System | PID + Fuzzy Logic |
| Display | 4.3" Color TFT Touchscreen |
| Temperature Range | −10 °C to 65 °C |
| Temperature Uniformity (15–45 °C) | ±0.2–0.5 °C |
| Temperature Stability | ±0.1 °C |
| Internal Volume | 150 L |
| Inner Dimensions (W×H×D) | 600×620×405 mm |
| External Dimensions (W×H×D) | 780×1200×802 mm |
| Net Weight | ~125 kg |
| Refrigeration | SECOP (Danfoss) Compressor + EBM Condenser Fan |
| Refrigerant | Eco-friendly R134a or equivalent |
| Insulation | Monolithic Polyurethane Foam (≥60 mm thickness) |
| Sensor | HERAEUS Platinum RTD (Class A, Pt100) |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating Power | 1000 W |
| Safety Features | Over-temperature alarm, compressor overpressure protection, door-open alert, leakage current protection, sensor fault detection, auto-restart after power recovery |
| Data Logging | ≥3 years of timestamped temperature/humidity (if equipped)/status data (non-editable, exportable via USB) |
| Audit Trail | ≥16,000 immutable entries (user actions, alarms, system events) |
| User Management | Up to 5 configurable roles with granular permission assignment |
| Communication Ports | RS232, RS485, USB host/device |
| Sterilization | Built-in UV-C lamp (254 nm) |
| Viewing Window | Tempered double-glazed inner door with silicone-sealed access port (Ø50 mm) |
| Language Support | Switchable English/Chinese GUI |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | MTN-460 |
| Control Method | PID + Fuzzy Logic |
| Display | 4.3-inch Color TFT Touchscreen |
| Temperature Range | –10°C to +65°C |
| Temperature Uniformity (at 25°C) | ±0.2–0.5°C |
| Temperature Stability | ±0.1°C |
| Internal Volume | 464 L |
| Internal Dimensions (W×H×D) | 750 × 1105 × 560 mm |
| External Dimensions (W×H×D) | 933 × 1765 × 960 mm |
| Net Weight | 210 kg |
| Heating Power | 1200 W |
| Compressor | SECOP (Danfoss) |
| Condenser Fan | EBM (Germany) |
| Refrigerant | Eco-friendly R134a or equivalent |
| Temperature Sensor | HERAEUS (Germany) |
| Insulation | Monolithic Polyurethane Foam |
| Door | Double-door structure with tempered glass inner door |
| Port | Ø50 mm silicone-sealed access port on right side |
| Communication Interfaces | USB, RS-232, RS-485 |
| Data Logging | Up to 3 experiment records stored internally |
| Audit Trail | ≥16,000 entries of operator actions and alarms, stored internally and exportable via USB (immutable) |
| User Management | Administrator-configurable up to 5 users with role-based permissions |
| Sterilization | Built-in UV lamp |
| Language Support | Switchable English/Chinese interface |
| Safety Features | Over-temperature alarm, compressor high-pressure protection, power-failure auto-restart, door-open alarm, sensor fault detection, leakage current protection, timer operation, automatic shutdown/recovery |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | STC 250 |
| Instrument Type | Vertical Temperature and Humidity Controlled Chamber |
| Cooling Method | Air-Cooled |
| Temperature Range | –10 °C to 85 °C |
| Humidity Range | 15–98 %RH |
| Temperature Uniformity | ±0.2–0.5 °C |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 %RH |
| Interior Dimensions (W×H×D) | 670 mm × 912 mm × 410 mm |
| Internal Volume | 250 L |
| Refrigerant | R134a |
| Compressor | Secop (Danfoss Group) |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touch screen |
| Data Logging | 10-year continuous storage (non-editable, USB export) |
| Audit Trail | 16,000+ immutable entries (user actions & alarms) |
| Communication Interfaces | RS232, RS485, USB |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 2200 W |
| Operating Ambient | 5–35 °C |
| Cabinet Insulation | Monolithic polyurethane foam (≥40 mm thickness) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA 460 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 %RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 %RH |
| Interior Dimensions (W×H×D) | 770 mm × 1200 mm × 500 mm |
| Interior Volume | 464 L |
| Compressor | Secop (Danfoss Group) |
| Condenser Fan | EBM (Germany) |
| Humidity Sensor | E+E Elektronik |
| Temperature Sensor | Heraeus |
| Insulation | Monolithic Polyurethane Foam |
| Display | 7-inch True-Color TFT Touchscreen |
| Control System | PID + Fuzzy Logic |
| Data Logging | ≥10 years (U盘-exportable, write-protected) |
| Audit Trail | 16,000 entries (U盘-exportable, immutable) |
| User Management | 5 configurable roles |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA 760 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.2–0.8 °C (at 15–45 °C) |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 1300 × 1180 × 500 mm |
| Internal Volume | 767 L |
| Refrigeration System | Inverter-Driven SECOP (Danfoss) Compressor with EBM Condenser Fan |
| Humidity Sensor | Capacitive E+E Electronics Sensor |
| Temperature Sensor | HERAEUS Platinum RTD |
| Insulation | Monolithic Polyurethane Foam (≥120 mm thickness) |
| Control System | 7-inch Full-Color TFT Touchscreen with PID + Fuzzy Logic Algorithm |
| Data Logging | ≥10 years of uneditable timestamped records (U-disk export only) |
| Audit Trail | 16,000+ immutable operation & alarm entries |
| User Management | 5 configurable roles with granular permission assignment |
| Communication Interfaces | RS232, RS485, USB |
| Compliance Support | GLP/GMP-aligned data integrity architecture (21 CFR Part 11–ready configuration optional) |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-1000 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.2–0.5 °C (at 15–45 °C) |
| Temperature Fluctuation | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 1300 mm × 1180 mm × 660 mm |
| Internal Volume | 1012 L |
| Refrigeration System | Inverter-Driven SECOP (Danfoss) Compressor with EBM Condenser Fan |
| Humidity Sensor | Capacitive E+E Electronics Sensor |
| Insulation | Monolithic Polyurethane Foaming |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | ≥10 Years of Immutable Raw Data (U-disk Export Only) |
| Audit Trail | 16,000+ Timestamped Operator & Alarm Events |
| User Management | 5 Configurable Accounts with Role-Based Permissions |
| Communication Interfaces | USB, RS-232, RS-485 |
| Language Support | English / Chinese Switchable |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Chamber Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | 3-year capacity (1-min intervals), exportable via USB, read-only |
| Audit Trail | 16,000+ immutable entries (operations & alarms), USB exportable |
| User Management | 5 configurable roles with hierarchical permissions |
| Communication Interfaces | RS232, RS485, USB-B |
| Compliance Support | GLP/GMP-ready logging, 21 CFR Part 11-compatible audit trail architecture |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-150S |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to +85 °C |
| Humidity Range | 10–98 %RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 %RH |
| Humidity Fluctuation | ±1.5 %RH |
| Internal Dimensions (W×H×D) | 600 × 620 × 405 mm |
| Internal Volume | 150 L per compartment |
| Total Volume | 300 L |
| Power Supply | AC 220 V, 50/60 Hz |
| Heating & Humidification Power | 1500 W × 2 |
| Refrigeration Power | 250 W (R134a) |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | E+E Elektronik, Austria |
| Temperature Sensor | Heraeus, Germany |
| Insulation | Monolithic Polyurethane Foam (≥80 mm thickness) |
| Data Logging | ≥10 years of uneditable raw data storage |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Display | 7-inch full-color capacitive touchscreen |
| Control Algorithm | PID + Fuzzy Logic hybrid control |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-250 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity | ±0.3–0.8 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Interior Dimensions (W×H×D) | 670 × 912 × 410 mm |
| Interior Volume | 250 L |
| Compressor | SECOP (Danfoss Group), Germany |
| Condenser Fan | EBM-Papst, Germany |
| Humidity Sensor | Capacitive, E+E Elektronik, Austria |
| Temperature Sensor | HERAEUS, Germany |
| Insulation | Monolithic Polyurethane Foam |
| Control System | PID + Fuzzy Logic |
| Display | 7-inch Full-Color TFT Touchscreen |
| Data Logging | ≥10 years (non-editable, USB export) |
| Audit Trail | 16,000 entries (user actions & alarms, non-editable, USB export) |
| User Management | 5 configurable roles with granular permissions |
| Communication Interfaces | RS232, RS485, USB |
| Language Support | English / Chinese Switchable |
| Power Supply | AC 220 V, 50/60 Hz |
| Safety Protections | Over-temperature, over-pressure, leakage current, low-water, door-open, sensor fault, auto-restart after power failure |
| Brand | ALISN |
|---|---|
| Origin | Shanghai, China |
| Model | THA-460 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.3 °C |
| Temperature Fluctuation | ±0.2 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Internal Dimensions (W×H×D) | 770 × 1200 × 500 mm |
| Compressor | Secop (Danfoss Group) |
| Condenser Fan | EBM-Papst |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Temperature Sensor | Heraeus platinum RTD |
| Insulation | Monolithic polyurethane foam |
| Power Supply | AC 220 V, 50/60 Hz |
| Data Logging | ≥10 years internal storage, USB export with write-protection |
| Audit Trail Capacity | 16,000 entries |
| User Management | 5 configurable roles with hierarchical permissions |
| Brand | ALISN |
|---|---|
| Model | THA760 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity (at 15–45 °C) | ±0.3 °C |
| Temperature Fluctuation | ±0.3 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Heating/cooling Rate | 1.0–3.0 °C/min |
| Internal Dimensions (W×H×D) | 1200 × 1180 × 540 mm |
| Internal Volume | 760 L |
| Refrigerant | R404a |
| Compressor | SECOP (Danfoss Group) |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Insulation | Monolithic polyurethane foam (≥100 mm thickness) |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touchscreen |
| Data Logging | 3-year storage (1-min interval), USB export, write-protected |
| Audit Trail | 16,000 entries (user actions & alarms), non-modifiable, USB-exportable |
| User Management | 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB host/device |
| Compliance Support | ASTM E145, ISO 17025, ICH Q1, USP <1151>, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-20KV |
| Voltage Range | 0–20 kV (continuously adjustable) |
| Arc Voltage Accuracy | ≤1% |
| Current Acquisition Resolution | Milliampere (mA)-level, real-time sampling |
| Communication Interface | USB 2.0 (up to 3 MB/s), RS-232, Bluetooth 5.0, optional regional Ethernet port |
| Control Mode | PC-based or embedded EPC terminal |
| Electrode Materials | Tungsten carbide, carbon steel, platinum |
| Cabinet Material | AISI 304 stainless steel |
| Compliance Standards | GB/T 1411–2002 (equivalent to IEC 61621:1997), ASTM D495, IEC 149, UL 746A |
| Safety Protections | Dual-stage overvoltage protection, short-circuit interruption, arc fault detection, interlocked safety door, automatic zero-voltage reset, post-test discharge circuit, independent grounding, TVS-based high-voltage surge suppression, software-based misoperation lockout |
| Calibration | Supplied with traceable calibration certificate from nationally accredited metrology institute (CNAS or equivalent) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDH-B |
| Output Voltage Range | 0–20 kV AC |
| Rated Power | 1.5 kVA |
| Test Current Options | 10 mA / 20 mA / 30 mA / 40 mA |
| Electrode Configuration | 110° included angle |
| Electrode Materials | Stainless steel plate electrode (25.4 mm × 12.7 mm × 0.15 mm), Tungsten carbide rod electrode (56 mm × 7 mm × 30 mm) |
| Arc Timing Accuracy | <5 ms |
| Voltage Regulation Error | ≤1% |
| Test Modes | Intermittent arc and continuous arc |
| Compliance Standards | GB/T 1411, IEC 61621, ASTM D495, IPC-TM-650 2.5.1, JIS C 2137, UL 746A |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BES |
| Price | USD 1,700 (approx.) |
| Resistance Range | 1 × 10⁴ Ω to 1 × 10¹⁸ Ω |
| Current Range | 2 × 10⁻⁴ A to 1 × 10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable) |
| Basic Accuracy | ±1% |
| Display | 32-bit LED LCD (simultaneous resistance and current readout) |
| Operating Environment | 0–40 °C, <80% RH |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~2.5 kg |
| Standard Electrodes | Solid disc electrode (Ø100 mm), concentric ring electrode (OD 75 mm / ID 55 ± 0.2 mm), cylindrical electrode (Ø50 mm), point-to-point probe set |
| Shielding Enclosure | 200 mm × 200 mm × 90 mm (internal height 50 mm) |
| Brand | All Precision Instrument |
|---|---|
| Model | BEST-121 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Voltage Range | DC 10 V, 50 V, 100 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | 8 hours |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 285 mm × 245 mm × 120 mm |
| Weight | ~6 kg (main unit) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BG-400A1 |
| Internal Dimensions (W×D×H) | 450 × 450 × 500 mm |
| Temperature Range | 10–300 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | Not Applicable (Dry Heat / UV Only) |
| UV Wavelength | 340 nm (UVA-340 lamp standard) |
| Black Panel Temperature Range | 40–80 °C (adjustable per test protocol) |
| Irradiance Control | 0.63–1.25 W/m² @ 340 nm |
| Chamber Volume | 100 L |
| Heating Power | 2000 W |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | GB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5 |
| Brand | All Precision Instrument |
|---|---|
| Model | BG-800 |
| Nominal Internal Volume | 50 L |
| Internal Dimensions (W×D×H) | 350 × 350 × 410 mm |
| External Dimensions (W×D×H) | 1110 × 870 × 1550 mm |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate (25 °C → 150 °C, unloaded) | ~35 min |
| Cooling Rate (25 °C → −40 °C, unloaded) | ~60 min |
| Power Supply | Standard industrial AC supply (specification compliant with GB/T 10592–2008 and IEC 60068-3-5) |
| Compliance | Designed per ISO 16750-4, ASTM D4329, IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), and GB/T 2423.1–2022 / GB/T 2423.2–2022 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BHG-9102 |
| Internal Dimensions (D×W×H) | 400 × 450 × 550 mm |
| Temperature Range | −40 °C to +150 °C (unloaded) |
| Humidity Range | 20–98 %RH (no active thermal load) |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ≤±0.5 °C (unloaded) |
| Humidity Fluctuation | ≤±3 %RH |
| Heating Rate | ≤40 min (20 °C to 100 °C) |
| Cooling Rate | ≤30 min (20 °C to −20 °C) |
| Control Accuracy | ±2 °C / ±3 %RH |
| Sensor Type | PT100 armored resistance thermometers (temperature & humidity), dry-wet bulb principle for RH calculation |
| Refrigeration System | Single-stage, imported Tecumseh (France) compressor, R404A refrigerant (DuPont), Danfoss (Denmark) expansion valve, Parker (USA) filter-drier, Castel (Italy) solenoid valve |
| Humidification System | Built-in stainless steel water tank with Taiwan-imported electronic level controller, visual glass water-level indicator |
| Controller | Programmable high-resolution color touchscreen HMI, bilingual (English/Chinese), PID + BTHC balanced temperature-humidity control, 10 program groups × 16 segments (160 total), max segment time 99 h 59 min, up to 999 full cycles, USB data logging support |
| Safety Protections | Over-temperature alarm (chamber & compressor), over-current/overload protection, phase failure & ground fault detection, fan motor thermal protection, dry-run prevention for humidifier, fuse and SSR-based zero-crossing power control, leakage current protection |