Physical Property Testing Instruments
Filter
Showing 1471–1500 of 4493 results
| Brand | Generic OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,200 (FOB) |
| Brand | OEM / Custom Brand Available |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2012, MIL-STD-2164A |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Operating Ambient | 25°C ±6°C, Unloaded |
| Control Method | PID-Based Balanced Temperature & Humidity Control (BTHC) |
| Refrigerant | R404A (Non-CFC, ODP = 0) |
| Compressor | Tecumseh/Taikang Hermetic Scroll Compressor |
| Noise Level | ≤60 dB(A) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 13,800 (FOB) |
| Power Supply | AC 220 V, 1-Phase, 50/60 Hz, 15 A, 4 kW |
| Internal Chamber Geometry | Cylindrical Stainless Steel (AISI 304) |
| Sealing Principle | Reverse-Pressure Dynamic Gasket Engagement |
| Pre-Test Purge | Vacuum-Assisted Air Exchange with Particulate Filter (≤1 µm) |
| Water Consumption | ≤1.2 L per 200 h continuous operation |
| Safety Protection | Dual-Limit Threshold Monitoring (Temperature/Pressure), Auto-Interlock Door Locking, Over-Pressure Relief Valve |
| Compliance | Designed to support ASTM D471, IEC 60068-2-30, MIL-STD-810H Method 507.7, and ISO 16750-4 test protocols |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Chamber Dimensions | Ø300 mm × L500 mm (Cylindrical) |
| External Configuration | Vertical Standing |
| Inner Tank Material | SUS316 Stainless Steel (3 mm thick) |
| Outer Casing Material | SUS316 Stainless Steel (1 mm thick) |
| Insulation | Rockwool + Rigid Polyurethane Foam |
| Steam Generator | Finned Seamless Stainless Steel Heating Tube with Platinum-Plated Surface |
| Humidity Range | 95–100 %RH (Saturated Steam Mode) |
| Temperature Range | RT+10 °C to 125 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Stability | ±1 %RH |
| Control Method | Direct Sensor-Based Feedback (Not Calculated from Saturation Tables) |
| Pressure Safety | Dual-Circuit High-Temperature Solenoid Valve, Overpressure & Overtemperature Cut-off, Manual & Emergency Depressurization, Interlocked Pressure-Activated Door Lock |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.3–1993 |
| Water Replenishment | Automatic On-the-Fly Refill System |
| Drying Function | Integrated Electric Dry-Out Cycle Post-Test |
| Display Interface | Real-Time P–T Correlation View per IEC/ISO Saturation Curve Reference |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB) |
| Temperature Range | –70°C to +150°C (Standard Configurable) |
| Humidity Range | 20–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Uniformity | ±1.0°C / ±3.0% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Temperature Range Options | A: 0–150°C |
| B | −20–150°C |
| C | −40–150°C |
| D | −70–150°C |
| Humidity Range | 20–98% RH (optional: 5–98% RH) |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Temp Uniformity | ±0.5°C |
| Humidity Uniformity | ±2.5% RH |
| Temp Stability | ±2.0°C |
| Humidity Stability | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Refrigerant | R404A/R23 (environmentally compliant) |
| Controller | Touchscreen LCD with English/Chinese interface |
| Interior Material | SUS#304 stainless steel |
| Viewing Window | Multi-layer tempered glass with conductive ITO film |
| Sealing | Dual-layer high-tension heat-resistant gasket |
| Safety | Real-time fault detection, automatic power cutoff, over-temperature/over-humidity protection |
| Compliance | MIL-STD-810G (via GJB 150.3/150.4), IEC 60068-2-1 (Cold), -2-2 (Dry Heat), -2-30 (Cyclic Humidity), GB/T 2423.1–2423.4 |
| Key Specifications | Temperature Range: Up to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Control Method | PID-controlled BTHC (Balanced Temperature and Humidity Control) System |
| Compliance | GB/T 2423.1–1989 (Test A), GB/T 2423.2–1989 (Test B), IEC 60068-2-1, MIL-STD-2164A, GJB 1032–1990, GJB 234–1985 |
| Protection Features | Independent overtemperature cutoff, dry-run protection for humidifier, low-water-level shutdown, compressor overload/overheat/overcurrent protection, high-pressure refrigerant switch, circuit breaker, and earth-leakage protection |
| Operating Conditions | Measured at ambient 25°C ±6°C, no-load state |
| Construction | Fully welded stainless steel inner chamber, insulated double-wall design with high-efficiency polyurethane foam |
| Air Circulation | Adjustable axial fan with balanced airflow distribution |
| Controller | Imported touchscreen PID controller with multi-segment programming, data logging, and real-time trend display |
| Customization | External dimensions and internal volume configurable per user requirements |
| Key Features | Microprocessor-based color touchscreen controller with Chinese/English interface |
|---|---|
| Refrigeration system | hermetic low-noise dual-stage compressor with eco-friendly refrigerants R404A/R23 |
| Temperature range options | 0 to 150°C, −20 to 150°C, −40 to 150°C, or −70 to 150°C |
| Humidity range | 20–98% RH (optional: 5–98% RH) |
| Temp. uniformity | ±0.5°C |
| Humidity uniformity | ±2.5% RH |
| Temp. fluctuation | ±2.0°C |
| Humidity fluctuation | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Heating rate | ~4.0°C/min |
| Cooling rate | ~1.0°C/min |
| Standard accessories | two SUS#304 shelves, four casters + four leveling feet, 2.5 m power cable (AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire) |
| Key Specifications | Temperature Range: -40°C to +150°C (typical, model-dependent) |
|---|---|
| Humidity Range | 20%–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Airflow Uniformity | ±1.5°C / ±3% RH (in working zone) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A–2018 |
| Safety Protections | Dry-run protection for humidifier, independent overtemperature cutoff, low-water level alarm, compressor overload/overheat/overcurrent protection, high-pressure refrigerant switch, circuit breaker, earth-leakage circuit interrupter (ELCI) |
| Construction | Seamless stainless steel inner chamber, double-wall insulation, P.I.D.-controlled BTHC (Balanced Temperature & Humidity Control) system with SSR-driven heating/humidification |
| Controller | Touchscreen HMI with programmable ramp-soak profiles, real-time data logging, USB export, optional Ethernet/RS485 interface |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (excl. tax & shipping) |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 7,200 (approx. based on ¥50,000 at 1 USD ≈ ¥6.95) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 2,650 (FOB Reference) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (approx. ¥19,000) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Control System | PID-based Balanced Temperature & Humidity Control (BTHC) |
| Safety Protections | Dry-run protection for humidifier, independent over-temperature cutoff, low-water level interlock, compressor overload/overheat/overcurrent protection, high-pressure refrigerant switch, circuit breaker, earth-leakage circuit interrupter (ELCI) |
| Operating Ambient | 25°C ± 6°C, no-load condition |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Structural Design | Full-arc exterior, flat non-reactive door handle, customizable external dimensions |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB) |
| Temperature Range | -40°C to +150°C (typical) |
| Humidity Range | 20–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Uniformity | ±1.5°C / ±3% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Operating Ambient | 25 °C ±6 °C, Unloaded |
| Cooling Water Requirement | 10–28 °C, 0.1–0.3 MPa |
| Protection Systems | Dry-run protection for humidifier, independent overtemperature cutoff, low-water-level interlock, compressor overload/overheat/overcurrent protection, high-pressure refrigerant switch, circuit breaker, RCD leakage protection |
| Control Method | Balanced Temperature-Humidity Control (BTHC) with PID-driven SSR output |
| Refrigeration | Capillary tube-based automatic capacity modulation system |
| Cabinet Design | Seamless arc-shaped stainless steel interior, flat non-reactive door handle, touch-screen controller with multi-segment programming |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 7,200 (Reference FOB) |
| Temperature Range | −70°C to +180°C (typical) |
| Humidity Range | 20–98% RH |
| Control Stability | ±0.5°C / ±2.0% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,000–4,200 (FOB, varies by configuration) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 29,500 (FOB) |
| Temperature Range | −65 °C to +150 °C |
| Humidity Range | 20–95 % RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Stability | ±1.5 % RH |
| Heating Rate | ≥2.5 °C/min (from +20 °C to +85 °C in ≤60 min) |
| Cooling Rate | ≥1.0 °C/min (from +20 °C to −40 °C in ≤70 min) |
| Refrigeration | Dual-stage mechanical refrigeration (hermetic compressors: Tecumseh or Embraco) |
| Refrigerant | R404A / R23 |
| Humidification | Stainless steel steam generator |
| Insulation | 100 mm high-density fiberglass + polyurethane foam |
| Interior | Mirror-finish SUS304 stainless steel |
| Exterior | Powder-coated A3 steel or brushed SUS304 |
| Viewing Window | Multi-layer tempered glass with conductive film defogging & Philips LED lighting |
| Power Supply | 3-phase 5-wire AC 380 V ±10 %, 50 Hz, PE grounding |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,000–4,200 (FOB ex-works, subject to configuration and certification requirements) |
| Temperature Range | −70°C to +180°C |
| Humidity Range | 10%–98% RH |
| Control Accuracy | ±0.5°C (temp), ±2.5% RH (humidity) |
| Uniformity | ±1.5°C (temp), ±3% RH (humidity) |
| Ramp Rate (typical, no load) | 1–3°C/min (heating), 0.7–2.5°C/min (cooling) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1:2022, IEC 60068-2-2:2022, GJB 1032A–2021, MIL-STD-2164A–2018 |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (FOB Reference) |
| Temperature Range | −40°C to +150°C |
| Humidity Range | 20%–98% RH |
| Control Accuracy | ±0.5°C / ±2.5% RH |
| Uniformity | ±1.5°C / ±3% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Brand | Third-party OEM |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Quoted Price | USD 3,000 (ex-works, excluding diagnostics, parts, or on-site labor) |
| Key | Temperature Range: -20°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Compliance | GB/T 5170.2, GB/T 5170.5, GB 2423.1, GB 2423.22, GB 10589, GB 11158 |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Control Method | PID-controlled BTHC (Balanced Temperature & Humidity Control) System |
| Construction | Full-capillary refrigeration circuit with auto-load capacity modulation |
| Operating Condition Basis | Measured at ambient 25°C ±6°C, no-load |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -70 °C to +200 °C |
| Humidity Range | 20–98% RH |
| Vibration Force | 300–5000 kgf (peak) |
| Frequency Range | 2–2000 Hz |
| Maximum Displacement | 25.4–51 mm (peak-to-peak) |
| Control Architecture | Independent Multi-Mode Control System (Standalone Temp/Humidity/Vibration or Fully Integrated Combined Operation) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -20°C to 150°C / -40°C to 150°C / -60°C to 150°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ≤ ±2°C |
| Ramp Rate | 0.7–1.0°C/min |
| Insulation Thickness | 100–120 mm |
| Viewing Window | Multi-layer tempered glass with conductive anti-fog film |
| Test Port | One Φ50 mm port on left side (customizable) |