Physical Property Testing Instruments
Filter
Showing 1381–1410 of 12274 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-RT-10 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-RT-10 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S-RT-30 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TT-1100 |
| Pricing | Upon Request |
| Brand | Chemplex |
|---|---|
| Origin | USA |
| Product Type | XRF Sample Support Films |
| Model | 100 |
| Thickness | 2.5 µm |
| Format | Roll (3.0" × 300') |
| Material | Mylar® Polyester Film |
| Compliance | ASTM E1361, ISO 8596, USP <233> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 57701 |
| Temperature Range | 0–180 °C |
| Compatibility | Ubbelohde, Ostwald, and Cannon-Fenske capillary viscometers |
| Mounting Options | Standard 4-hole viscometer holder (Ø4/6/8/10 mm) |
| Sensor Interface | Pt-100 RTD port with 2-wire or 4-wire configuration |
| Fluid Circulation | Compatible with CD-200F thermostatic circulator (external) |
| Sealing | ND60 O-ring (22534) and NW60 quick-clamp (07234) included |
| Pump Integration | Supports VZ 5655 VISCO Pump for automated efflux timing |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ALPHA |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 60 – 40,000,000 cP |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.3–100 rpm |
| Speed Steps | 18 |
| Viscosity Accuracy | ±1% of full scale |
| Viscosity Repeatability | ±2% of full scale |
| Display Resolution | 0.01–1 cP |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | USB-B |
| Compliance | CE, RoHS |
| Language Support | 7 languages (including English, German, French, Spanish, Italian, Chinese, Japanese) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | APM / LCP / Heldal |
| Pricing | Upon Request |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer |
| Design | Portable |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.35 – 100,000 mm²/s |
| Compliance | ISO/DIS 3105, ASTM D2515, ASTM D466, NF T 60-100, BS 188, GB/T 11137, SH/T 0654, ISO/IEC 17025 (calibrated at 40 °C and 100 °C) |
| Sample Compatibility | Transparent or opaque liquids |
| Fill Volume | 7–12 mL |
| Total Length | 245–295 mm |
| Calibration | Factory-calibrated with certified K-values and annular timing marks |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Numbers | 05392, 05393, 05396, 05397, 06499 |
| Material Options | Stainless Steel (05392–05397), Polyamide (06499) |
| Angular Tolerance | < 1° |
| Compatibility | Ubbelohde, TC Ubbelohde, Cannon-Fenske Reverse Flow, Micro-Ostwald, Ostwald, and Cannon-Fenske Routine viscometers |
| Application | Manual and automated capillary viscometry in thermostatted baths |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CV003-100 / CV003-001 |
| Instrument Type | Portable Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 – 50,000 mm²/s (cSt) |
| Fill Volume | 11 mL |
| Accuracy | ±0.2% |
| Compliance | DIN 51562-1, ISO 3105, ASTM D445, ASTM D2515, ISO 3104, UNE 400313 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CV005-001 |
| Instrument Type | Portable Capillary Viscometer |
| Viscosity Range | 0.6 – 30,000 mm²/s (cSt) |
| Capillary Diameter | 0.4 mm |
| Compliance | ASTM D445, ISO 3104, ISO 3105, GB/T 265, SH/T 0173 |
| Sample Requirement | Clear, Newtonian or near-Newtonian liquids |
| Operating Environment | Ambient temperature (15–30 °C) |
| Measurement Principle | Gravimetric capillary flow time |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DCA400 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Contact Angle Measurement Range | 0–180° |
| Surface/Interfacial Tension Accuracy | ±0.02 mN/m |
| Measurement Method | Wilhelmy Plate Method |
| Tension Range | 1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Maximum Sample Load | ≤110 g |
| Density Measurement Range (with optional accessories) | 0.5–2.25 g/cm³ |
| Density Readability/Repeatability | ±0.00005 g/cm³ |
| Power Supply | 230 V (−15% / +10%), 50 Hz, 10 VA |
| Dimensions (W × D × H) | 210 × 370 × 380 mm |
| Weight | 8 kg |
| Standard Accessories | Manual-adjustable motorized Z-stage, custom borosilicate glass plate (24 × 24 × 0.15 mm), platinum-iridium Wilhelmy plate, glass measurement beaker, temperature-controlled jacketed cup (optional), Du Noüy ring kit (optional) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DenDi |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Archimedean Buoyancy (Oscillating U-tube not used |
| Density Range | 0 to 3 g/cm³ (0 to 3000 kg/m³) |
| Accuracy | ±0.0005 g/cm³ (±0.5 kg/m³) |
| Repeatability | ±0.00025 g/cm³ (±0.25 kg/m³) |
| Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
| Temperature Range | +15 °C to +30 °C |
| Temperature Accuracy | ±0.01 °C |
| Sample Volume | 100 mL |
| Power Supply | Rechargeable NiMH 9 V / 150 mAh battery (up to 12 h operation) |
| Dimensions (H × L × W) | 135 × 100 × 190 mm |
| Weight | 1.3 kg |
| Compliance | ASTM D1298, ASTM D4052 (for reference correlation), ISO 12185 (petroleum density), DIN 51757, EN ISO 279 |
| Data Storage | 998 timestamped measurements onboard |
| Interface | Infrared (IrDA) for PC and thermal printer connectivity |
| Display | Backlit LCD with multi-unit real-time readout |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 53100 |
| Instrument Type | Portable Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 – 60 mm²/s |
| Fill Volume | 15 – 75 mL |
| Total Length | ~290 mm |
| Capillary Inner Diameter Options | 0.36–1.15 mm |
| Calibration Constant (K) Range | 0.001–0.1 mm²/s |
| Compliance | ASTM D445, ISO 3104, IP 71 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-070 |
| Instrument Type | Density Gradient Tube System |
| Portability | Portable |
| Measurement Medium | Liquids |
| Temperature Range | +5–60 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.01 °C |
| Bath Volume | 25–31 L |
| Heating Power | 2–11 W |
| Circulation Pump Pressure | 0.23–0.45 bar |
| Interface | RS-232 |
| Compliance | ASTM D1505, ISO 1183-1, USP <841> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.1N |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Temperature Range | −40 to +85 °C |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Temperature Repeatability | ±0.1 °C |
| Measurement Depth | 6 m |
| Display | OLED with backlight |
| Data Storage | 3000 readings |
| Battery | NiMH 3.6 V, 2500 mAh (≈40 h operation) |
| Communication | Bluetooth & USB |
| Sensor Materials | SS 316L, NiSpan C, Hastelloy C-22 (optional) |
| Certified | ATEX, IECEx HazLoc |
| Units Supported | g/cm³, kg/m³, lb/gal, lb/ft³, API, SG, ASTM D1250, alcohol tables, relative density at 15 °C / 20 °C / 60 °F / API60 / SG60 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.2N |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ (±0.3 or ±0.5 kg/m³) |
| Temperature Range | −40 to +85 °C |
| Temperature Accuracy | ±0.1 or ±0.2 °C |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ (±0.15 or ±0.25 kg/m³) |
| Temperature Repeatability | ±0.1 °C |
| Max. Immersion Depth | 30 m |
| Data Storage Capacity | 2000 measurements |
| Battery | NiMH 3.6 V, 1500 mAh |
| Operating Time (fully charged) | ~12 h |
| Display | OLED with backlight |
| Sensor Materials | SS 316L stainless steel, NiSpan C, or Hastelloy C-22 (optional) |
| Compliance | ATEX, IECEx, UL/CSA HazLoc |
| Units Supported | g/cm³, kg/m³, lb/gal, lb/ft³, API gravity, specific gravity (SG), ASTM D1250 petroleum tables, alcohol tables, temperature (°C/°F) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.3 |
| Instrument Type | Oscillating U-tube Densimeter |
| Portability | Portable |
| Sample State | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.0003 or ±0.0005 g/cm³ |
| Density Repeatability | ±0.00015 or ±0.00025 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −40 °C to +85 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Pressure Rating | 16 bar (1.6 MPa) |
| Sensor Material Options | SS 316L, NiSpan C, Hastelloy C-22 |
| Intrinsic Safety Certification | ATEX II (2G) EEx ib [ia] IIB T4 (controller), ATEX II 1G EEx ia IIB T4 (sensor) |
| Sample Volume | 250 mL |
| Power Supply | Rechargeable NiMH 3.6 V / 1500 mAh (up to 12 h operation) |
| Dimensions (Controller) | 245 × 225 × 120 mm |
| Dimensions (Sensor) | 180 × 85 × 40 mm |
| Weight | ~6 kg |
| Display | Backlit LCD |
| Data Storage | 1980 entries with timestamp |
| Connectivity | Bluetooth, USB, printer/PC interface |
| Software | Windows-based data acquisition and analysis software |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-250.5 |
| Instrument Type | Portable Buoyancy-Based Density Meter |
| Application | Liquid Density Measurement |
| Density Range | 0 to 3 g/cm³ (0 to 3000 kg/m³) |
| Density Accuracy | ±0.0003 g/cm³ (±0.3 kg/m³) |
| Repeatability | ±0.00015 g/cm³ (±0.15 kg/m³) |
| Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
| Temperature Range (Measurement) | −30 °C to +50 °C |
| Temperature Accuracy | ±0.1 °C |
| Operating Ambient Temperature | −40 °C to +85 °C |
| Viscosity Compensation Limit | up to 2000 cP |
| Intrinsic Safety Certification | ATEX II (2G) EEx ib [ia] IIB T4 (Controller), ATEX II 1G EEx ia IIB T4 (Sensor) |
| Communication | Bluetooth v5.0, Internal Data Storage |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | DM-300 |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ |
| Temperature Range | 0–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Probe Material | 316L Stainless Steel, Nickel-Based Alloy, Hastelloy C-22 |
| Dimensions | 140 × 100 × 290 mm |
| Weight | ~2 kg |
| Compliance | CE (EN 61326, EN 5011, EN 50082-2) |
| Data Interface | Bluetooth |
| Viscosity Compensation | Yes |
| Instrument Type | Oscillating U-tube Digital Density Meter |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Oscillating U-tube Densimeter |
| Portability | Benchtop (Compact Design) |
| Sample Type | Liquids, Emulsions, Pastes |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | DS7700: ±0.001 g/cm³ |
| DS7800 | ±0.0001 g/cm³ |
| Temperature Range | 10–40 °C |
| Temperature Accuracy | ±0.02 °C |
| Sample Volume | <1 mL |
| Measurement Cycle | 1–3 min (including thermal equilibration) |
| Display | 5.7″ TFT Touchscreen |
| Data Storage | Tamper-Resistant Memory (999 entries) |
| Compliance | ASTM D4052, ISO 12185, USP <841>, Ph. Eur. 2.2.39, JP 2.05, OIML R 22, ICUMSA Methods, FDA 21 CFR Part 11, GLP/GMP Audit Trail Ready |
| Interfaces | RS232, USB, Ethernet |
| Dimensions | 220 × 220 × 430 mm |
| Weight | 5.3 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | FCI003 |
| Standard | ISO 2431 |
| Orifice Diameter | 3 mm |
| Viscosity Range | 5–42 cSt |
| Instrument Type | Fixed-geometry efflux viscometer |
| Application Environment | Ambient temperature (25 °C standard) |
| Compliance | ISO 2431, ASTM D1200 (cross-referenced), DIN 53211 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GSA |
| Density Measurement Range | 0.9000–1.0500 g/cm³ |
| Particle Size Range | 0.001–0.1 mm |
| Sample Capacity | 12 simultaneous measurements |
| Temperature Compensation | Automatic, based on Stokes’ law |
| Repeatability | < 2% RSD |
| Compliance | ASTM D422, ISO/TS 17892-4 |
| Programmable Parameters | Soil density, gravitational acceleration, data acquisition interval, sedimentation duration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Hydrom 070 |
| Instrument Type | Density Gradient Tube System |
| Portability | Portable |
| Sample Type | Liquids |
| Temperature Range | 20–60 °C |
| Compliance | Designed for ASTM D1298, ISO 3675 & ISO 12185 compliant density determination |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ISP-1, ISP-2, ISP-1HD |
| Application | Polymer, pulp, and HDPE/PP sample preparation for rotational rheometry and capillary viscometry |
| Compliance | Designed for GLP-compliant workflows with audit-trail-ready data transfer to RPV-1 viscosity software |
| Safety | Integrated self-diagnostic routines and real-time error detection |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M-2000 |
| Instrument Type | Humidity & Temperature Calibration Chamber |
| Humidity Range | 10–95 %RH (at 23 °C) |
| Temperature Range | 10–50 °C |
| Humidity Accuracy | ±1 %RH (10–90 %RH), ±2 %RH (>90 %RH) |
| Temperature Accuracy | ≤±0.2 °C |
| Chamber Humidity Stability | ±0.2 %RH (20–25 °C) |
| Chamber Temperature Stability | ±0.1 °C |
| Chamber Humidity Uniformity | ±0.3 %RH |
| Chamber Temperature Uniformity | ±0.2 °C |
| Humidity Setpoint Response Time (Δ30 %RH) | <10 min |
| Cooling Rate | 1.0 °C/min (ambient 23 °C) |
| Heating Rate | 3.0 °C/min (ambient 23 °C) |
| External Gas Flow Rate | up to 3 L/min (requires external temperature-stable loop) |
| Dimensions (W×D×H) | 450 × 360 × 210 mm |
| Net Weight | 13 kg |
| Digital Interface | RS232 / RS485 (optional) |
| Calibration Certificate | NVLAP-accredited |
| Reference Standard | Dual-Pressure Humidity Generator |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M3000 |
| Temperature Range | 30–360 °C |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±0.3 °C (30–200 °C), ±0.5 °C (200–360 °C) |
| Heating Time | ~4.0 min to 300 °C, ~7.5 min to 360 °C |
| Heating Rate | 1 °C/min |
| Sample Positions | 3 |
| Capillary Diameter | 1.4 mm |
| Interface | RS-232 |
| IP Rating | IP20 |
| Power Supply | 90–264 V AC |
| Dimensions | 210 × 360 × 230 mm |
| Weight | 4.3 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | M5000 |
| Temperature Range | 25–400 °C |
| Heating Time to 300 °C | 4 min |
| Heating Time to 400 °C | 7.5 min |
| Temperature Repeatability | ±0.2 °C |
| Temperature Accuracy | ±0.3 °C (25–200 °C), ±0.5 °C (200–400 °C) |
| Capillary Diameter | 1.4 mm |
| Capillary Measurement Port | 1 |
| Interface | RS232 |
| Ingress Protection Rating | IP20 |
| Power Supply | 85–264 V AC, 47–440 Hz |
| Dimensions (L×W×H) | 230 × 210 × 110 mm |
| Weight | 1.8 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 53610 / 57210 |
| Viscometer Type | Capillary (Ubbelohde) |
| Design Standard | DIN 55350-18, DIN 55526-2, DIN 51562-2 |
| Capillary Geometry | Dilution-type, suspended-level |
| Operating Temperature Range | 10–80 °C (standard), optional -40 to +30 °C or 70 to 150 °C variants |
| Kinematic Viscosity Range | 0.4–8000 mm²/s |
| Sample Volume | 3–4 mL |
| Total Length | ~290 mm (536xx/537xx/538xx), ~350 mm (572xx/573xx/574xx) |
| Calibration | Certified K-value (4 significant digits) available for 536xx (manual use) and 537xx/572xx/573xx (automated systems) |
| Compliance | Traceable to national standards with factory calibration certificate included |