| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Model | TMA7100 / TMA7300 |
| Temperature Range | –170 °C to 600 °C (TMA7100) |
| Displacement Range | ±5 mm |
| Sensitivity (RMS Noise) | 0.005 µm / Resolution: 0.01 µm |
| Load Range | ±5.8 N (Resolution: 9.8 µN) |
| Heating Rate | 0.01–100 °C/min |
| Sample Max Dimensions | Ø10 mm × 25 mm (cylindrical) or 5 mm × 1 mm × 25 mm (film) |
| Probe Mounting | Cantilever-type |
| Atmosphere Control | Ambient, inert gas, vacuum (~1.3 Pa), optional humidity & swelling modules |
| Load/Displacement Control Modes | Constant force, constant rate, oscillatory (0.001–1 Hz), multi-step sequences (up to 40 steps) |
| Optional Cooling | Automated LN₂ cooling (–150 °C to 600 °C), electronic cooler (–60 °C to 450 °C), forced-air cooling (RT–600 °C), LN₂ Dewar kit (–170 °C to 600 °C) |
| Sample Tube Materials | Quartz (TMA7100), Alumina (TMA7300) |
| Probe Types | Expansion/compression quartz, penetration (standard & conical), tensile (quartz & metal), bending, sapphire dilatometry |
| Brand | HKM |
|---|---|
| Origin | Guangdong, China |
| Model | HGS-W21 (Wireless Indoor Temp/RH Logger), HGS-R5 (433 MHz Wireless Data Concentrator) |
| Communication | 433 MHz ISM-band RF (licensed by China NRR) |
| Storage | Onboard non-volatile memory (≥32,000 records per unit) |
| Alarm | Configurable high/low thresholds with local buzzer |
| Compliance | Designed to support GSP (China Good Supply Practice), GLP (Good Laboratory Practice), and archival environmental control per DA-001–2021 (National Archives Administration of China) |
| Connectivity | Up to 250 wireless sensors per concentrator (HGS-R5) |
| Software | Windows-compatible (Win7–11), real-time graphing, statistical reporting (min/max/avg), audit trail export (CSV/PDF), alarm log with timestamp and event annotation |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HMD-1 |
| Measurement Principle | Oscillating U-tube (Digital Density Determination) |
| Sample Volume | 2 mL |
| Display | Color LCD with backlighted viewing window |
| Power | Rechargeable battery (≥6 h continuous operation) |
| Accuracy | ±0.001 g/cm³ |
| Temperature Control | Peltier-assisted (±0.02 °C stability) |
| Compliance | ISO 12084, ASTM D4052, USP <841> |
| Brand | Huameike (LABULK) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HMK-200 (01081623) |
| Principle | Air Jet Sieving |
| Measurement Range | 3–5000 µm |
| Maximum Load | 2000 g |
| Sieve Stages | Single-stage |
| Brand | LABULK |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Intelligent |
| Display | Digital Readout Panel, Touchscreen, PC Interface |
| Measurement Principle | Fisher Air Permeability (HMK-22), Air Jet Sieving (HMK-200), Static Light Scattering / Mie Theory (AS-2011) |
| Size Range | 0.2–50 µm (HMK-22), 3–5000 µm (HMK-200), 0.1–500 µm (AS-2011) |
| Repeatability | ≤3% (HMK-22), ≤3% (HMK-200), <1% (AS-2011) |
| Porosity Range | 0.25–0.95 (HMK-22) |
| Air Pressure | 0–10 kPa (HMK-200), 5 kPa (HMK-22) |
| Power Supply | 220 V / 50 Hz (all models), 110 V / 60 Hz (HMK-22 optional) |
| Weight | 18 kg (HMK-22), 14.8 kg (HMK-200), N/A (AS-2011) |
| Dimensions | 41.8 × 24.6 × 73.7 cm (HMK-22), 58 × 35 × 35 cm (HMK-200), N/A (AS-2011) |
| Compliance | ISO 13320-1 (AS-2011), ASTM B330 (HMK-22), ISO 4497 (HMK-200) |
| Brand | Hmsense |
|---|---|
| Origin | United Kingdom |
| Model | VL7-100B |
| Instrument Type | Oscillating Viscometer |
| Viscosity Range | 0–100,000 cP |
| Temperature Range | –20 to +120 °C |
| Sample Volume (Standard) | 100 mL |
| Sample Volume (Mini Probe Option) | 10 mL |
| Repeatability | <1% |
| Probe Weight | 700 g (Standard), 500 g (Mini) |
| Display Unit Weight | 500 g |
| Total Length | 305 mm (Standard), 215 mm (Mini) |
| Wetted Materials | ASTM A240 Grade 316 Stainless Steel |
| Housing Material | Delrin® (Polyoxymethylene, POM) |
| IP Rating | IP65 |
| Power Supply | 4 × AA Alkaline Batteries |
| Integrated Temperature Sensor | Yes |
| Calibration Correction | Real-time viscosity/temperature compensation |
| Sensing Surface Finish | Electro-polished Alloy C-22 (N06022) |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Dongguan, Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Class | Video-Based Optical Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Sample Stage Dimensions | 130 × 150 mm (customizable) |
| Max Sample Size | 200 (W) × ∞ (L) × 30 (H) mm |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Tilt Mechanism | Motorized whole-stage tilting for advancing/receding angle and roll-off angle measurement |
| Imaging | Sony 1/1.8″ progressive-scan CMOS sensor (1280 × 1024), 80 fps, rolling shutter |
| Illumination | Imported industrial-grade cold white LED backlight (400–760 nm), PWM-dimmable, >50,000 h lifetime |
| Software | CA V2.0 Static/Dynamic Contact Angle & Surface Energy Analysis Suite (Windows 10 64-bit) |
| Calibration | Traceable certified angle standards (5°, 8°, 30°, 60°, 90°, 120° optional) |
| Data Management | Audit-trail-enabled reporting (PDF/Excel/Word), GLP-compliant history database, role-based user access (operator/admin) |
| Brand | Hokuto Instruments (HOKUTOcn) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | CA/300 |
| Instrument Type | Benchtop Video-Based Optical Contact Angle Meter |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° |
| Contact Angle Resolution | 0.001° |
| Standard Sample Stage Size | 300 × 300 mm (customizable up to 1000 × 1000 mm) |
| Maximum Sample Dimensions | 300 mm (W) × ∞ (L) × 50 mm (H), customizable |
| Surface/Interfacial Tension Range | 0.1–2000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.01 mN/m |
| Surface/Interfacial Tension Resolution | 0.001 mN/m |
| Brand | Hongri Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRJ-C |
| Price | USD 8,200 (FOB) |
| Maximum Output Voltage | 20 kV AC/DC |
| Compliance | GB/T 1408.1–2016, GB/T 13542.1–2009, GB/T 1695–2005, GB/T 3333–1999 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | LA-350 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 100 nm – 1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10 s |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | LA-960 V2 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 5000 µm |
| Repeatability | ±0.1% |
| Measurement Time | 10 seconds |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SA-9650 |
| Instrument Type | Specific Surface Area Analyzer |
| Measurement Principle | Dynamic Flow Method (Gas Adsorption) |
| Number of Analysis Stations | 1–3 |
| Specific Surface Area Range | 0.10 to >2000 m²/g |
| Repeatability | RSD < 1% |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SZ-100 V2 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Characterization System |
| Size Range | 0.3 nm – 10 µm |
| Reproducibility | ±2% |
| Measurement Time | < 2 min |
| Zeta Potential Range | −500 mV to +500 mV |
| Molecular Weight Range | 1,000 – 2×10⁷ Da |
| Detection Angles | 90° and 173° (automatically or manually selectable) |
| Sample Volume | 12 µL – 1,000 µL |
| Measurement Principle for Size | Dynamic Light Scattering (DLS), also known as Photon Correlation Spectroscopy (PCS) |
| Zeta Potential Principle | Laser Doppler Electrophoresis |
| Molecular Weight Determination | Debye Plot Analysis |
| Second Virial Coefficient (A₂) | Yes |
| Integrated Auto-Titrator | Yes (for pH-controlled zeta potential studies) |
| Compliance | NIST-traceable calibration with 100 nm standard particles |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ViewSizer 3000 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 10 nm – 15 µm |
| Repeatability | Not Specified |
| Measurement Time | 6 min |
| Key | Max. Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Sweep Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max. Acceleration | 20 g |
| Vibration Axes | Vertical (Z) + Horizontal (X/Y) |
| Waveform | Sine |
| Programmable Segments | 1–15 segments, each with user-defined frequency & duration, loopable |
| Octave Sweep Modes | 5-step logarithmic (low→high, high→low, low→high→low, repeatable) |
| Power Rating | 2.2 kW |
| Table Dimensions (L×W) | 500×500 mm (customizable) |
| Unit Dimensions (L×H×W) | Vertical unit: 500×200×500 mm |
| Horizontal unit | 500×250×500 mm |
| Input Voltage | 1φ AC 220 V, 50/60 Hz |
| Max. Current | 6 A |
| Frequency Resolution | 0.01 Hz, Accuracy: ±0.1 Hz |
| Table Mounting Pattern | Customizable M6/M8 threaded holes |
| Optional Accessories | Magnesium alloy fixtures, FEM-optimized fixtures, circular/square/octagonal extension tables, thermal isolation pads for environmental chamber integration |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Load Capacity Options | 50 / 100 / 200 / 500 / 1000 kgf |
| Force Resolution | 1/100,000 (1/250,000 for ≤10 kN models) |
| Force Accuracy | ≤0.5% FS (≤0.25% FS for ≤10 kN models) |
| Crosshead Travel | 1000 mm (excl. grips) |
| Test Speed Range | 5–300 mm/min (software-controlled, stepless) |
| Drive System | Panasonic AC servo motor + servo driver |
| Transmission | Precision ground ball screw + timing belt + Liming gearbox |
| Load Cell | Explosion-proof high-precision strain-gauge transducer with auto-thermal compensation, zero drift <0.01% FS/°C, repeatability ±0.03% FS, overload capacity 150% FS |
| Position Feedback | 2500 PPR optical encoder |
| Safety Features | Mechanical stroke limiter, software-based load upper-limit alarm, automatic halt on specimen rupture |
| Data Acquisition | PC-based real-time control and analysis, curve plotting (stress–strain, load–displacement), peak hold, auto-stop on break, unit switching (g/kg/N/kN/lbf), report generation & export (PDF/Excel) |
| Brand | HPHC |
|---|---|
| Origin | Beijing, China |
| Model | CM8310 Series |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Gas Inlet Ports | 8 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.001 °C |
| Heating Rate | 1 °C/min |
| Pressure Range | Atmospheric |
| Test Capabilities | TPD, TPR, TPO, Pulse Chemisorption (Metal Dispersion), Vapor Adsorption, BET Single-Point Surface Area, Multi-Component Competitive Adsorption |
| Detector | Tungsten-Rhenium Alloy Thermal Conductivity Detector (TCD) |
| TCD Count | 1 |
| Mass Flow Controllers | 2 |
| Exhaust Flow Meter | 1 |
| Electric 6-Port Valve | 1 |
| Electric 4-Port Valves | 2 |
| Furnace Control | Dual-point (“Bed Temp” & “Furnace Temp”) |
| Sample Temperature Sensing | Independent RTD or Thermocouple |
| Internal Line Insulation | Up to 300 °C |
| Gas Flow Range | 5–100 SCCM |
| Tubing Material | 1/8″ SS316 |
| Optional Accessories | Integrated Vapor Generator (Continuous & Pulsed Modes), Customizable LOOP Volumes (≥3 Options), Cold Trap (1), Forced-Air Cooling System (1) |
| Brand | HUAXI INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | XD50 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0003 g/cm³ |
| Repeatability | ±0.0002 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Temperature Control Range | 5–65 °C |
| Display | 7-inch Full-Color Touchscreen |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCYQ-STA-1550 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Options | N₂, O₂ |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TGA-605 |
| Temperature Range | Ambient to 1550 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 5 g |
| Mass Sensitivity | 0.01 mg |
| Mass Repeatability | ±0.01 mg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | ±0.1 °C |
| Baseline Reproducibility | ±0.1 °C |
| Sampling Frequency | 0.05–10 Hz (programmable) |
| Dual-Temperature Sensing | Furnace & Sample |
| Control Modes | FTC (Fixed Temperature Control) & STC (Sample Temperature Control) |
| Programmable Temperature Stages | Up to 12 |
| Cycle Repetition | Up to 9999 cycles with auto-data retention |
| Atmosphere Control | Two independent gas lines with software-driven switching |
| Display | 7-inch 24-bit color LCD touchscreen |
| Cooling System | Integrated capillary water-circulation furnace jacket |
| Furnace Design | Modular ceramic insulation with dual-purge gas channels |
| Optional Exhaust Interface | Dedicated port for off-gas coupling to FTIR or MS |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HY-766B |
| Pricing | Available Upon Request |
| Roller Diameter | 150.0 ± 0.2 mm |
| Roller Length | ~500 mm |
| Lateral Traverse per Revolution | 4.2 ± 0.04 mm |
| Test Loads | 2.0 ± 0.1 N, 5.0 ± 0.1 N, 10.0 ± 0.2 N |
| Roller Speed | 40 ± 1 rpm (adjustable) |
| Abrasion Distance | 20.0 ± 0.1 m or 40.0 ± 0.2 m (digitally preset) |
| Display | LCD Controller |
| Sample Rotation Mode | Selectable (Self-Rotating / Non-Self-Rotating) |
| Specimen Holder ID Range | 15.5–16.3 mm (adjustable), Projection Height: 2.0 ± 0.2 mm |
| Holder Axis Tilt | 3° from vertical |
| Holder-to-Roller Axial Offset | ±1 mm |
| Arm Stability | Vibration-free during operation |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-7721C |
| Price | USD 1,760 (FOB Tianjin) |
| Standard Compliance | GB/T 6670–2008, ASTM D3574, ISO 8307 |
| Drop Height (Method A) | 500 ± 0.5 mm |
| Drop Height (Method B) | 460 ± 0.5 mm |
| Ball Mass (Method A) | 16.8 ± 1.5 g |
| Ball Mass (Method B) | 16.3 g |
| Ball Diameter | 16.0 ± 0.5 mm |
| Sample Dimensions | 100 × 100 × 50 mm (L × W × H) |
| Rebound Accuracy | < ±1.5% |
| Measurement Output | Average rebound height, average rebound percentage, statistical summary per test set |
| Control System | Industrial PLC + 7-inch TFT touch HMI (Chinese UI) |
| Data Output | Integrated thermal micro-printer (desktop type) |
| Sensor | High-speed optical distance sensor (non-contact, 1 kHz sampling) |
| Brand | ADVANTEC |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | T5 Plus |
| Instrument Type | Portable Densitometer |
| Measurement Mode | Transmission (Black-and-White) |
| Sample Type | Solid and Liquid (Transparent/Translucent) |
| Density Range | 0–2.000 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Aperture Options | φ1 mm, φ2 mm, φ3 mm |
| Power Supply | AC Adapter (9 V DC, 500 mA) |
| Compliance | ISO 5-3, ISO 5-4, ASTM E308, JIS Z 8722 |
| Software Interface | RS-232C (cable sold separately) |
| Calibration Standards | NIST-traceable calibration film included |
| Operating Temperature | 15–35 °C |
| Relative Humidity | ≤80 % RH (non-condensing) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |