| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA200 |
| Coupling Technique | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Sensitivity | 0.01 mg |
| DSC Range | ±800 mW |
| DSC Resolution | 0.001 mW |
| Display | 7-inch 24-bit Color Touchscreen |
| Communication Interface | USB 2.0 |
| Gas Control | Dual-channel Mass Flow Controller with Integrated Flow Meters |
| Calibration | Multi-point Temperature & Enthalpy Calibration |
| Software Compliance | Audit Trail, Data Export (CSV, Excel, PDF), GLP-Ready Reporting |
| Brand | DAZHAN |
|---|---|
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1200 °C |
| Heating Rate | 0.1–100 °C/min |
| Max Sample Mass | 5 g |
| Atmosphere Control | Dual-gas manifold with integrated mass flow meters and automated switching |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| TG Sensitivity | 0.1 µg |
| TG Accuracy | 0.01 mg |
| DSC Range | ±1000 mW |
| DSC Resolution | 0.1 µW |
| DSC Accuracy | 0.01 mW |
| Cooling Time (1000 °C → 100 °C) | ≤15 min |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Mass Range | 0.01 mg–3 g (expandable to 30 g) |
| Mass Sensitivity | 0.01 mg |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidative, reductive, static, dynamic) |
| Data Interface | Standard USB |
| Software | Integrated TGA analysis suite with TG/DTG curve processing, Excel/PDF export, multi-point temperature calibration, and audit-ready reporting |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA101 |
| Temperature Range | Ambient to 1200 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Dual-gas inlet with mass flow regulation (inert, oxidizing, reducing, static, dynamic) |
| Balance Sensitivity | 0.01 mg |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Programmable Stages | Up to 5 temperature segments |
| Isothermal Hold Duration | 0–300 min per segment (configurable up to 72 h total) |
| Display | 7-inch Chinese-language LCD |
| Interface | USB 2.0 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DZ-TGA201 |
| Structural Design | Top-loading (elevating furnace) |
| Operating Environment | Ambient pressure |
| Sample Capacity | Single sample |
| Instrument Class | General-purpose TGA |
| Temperature Range | Ambient to 1250 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.01 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Dynamic Weighing Range | 0.01 mg to 3 g (extendable to 50 g) |
| Balance Sensitivity | 1 µg |
| Mass Accuracy | ±1 µg |
| Mass Repeatability | ±1 µg |
| Maximum Sample Mass | 50 g |
| Atmosphere Control | Triple-gas mass flow control (inert, oxidative, reducing) |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Adaptive PID with self-tuning and memory-based multi-segment programming |
| Exhaust Interface | Dedicated outlet for coupling with FTIR, MS, or GC-MS |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose TGA |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Accuracy | ±0.01 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 K/min |
| Maximum Sample Mass | 30 g |
| Temperature Resolution | 0.1 °C |
| Mass Resolution | 0.1 µg |
| Isothermal Hold Duration | Up to 600 min (standard), user-definable |
| Atmosphere Control | Triple-Gas Mass Flow Controller (MFC) System |
| Cooling Time | ≤20 min (1000 °C → 50 °C) |
| Temperature Control Algorithm | Intelligent PID with Self-Tuning & Hybrid Static/Dynamic Optimization |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Principle | Transient Plane Source (TPS) Method |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.00001 W/(m·K) |
| Temperature Range | −30 °C to 200 °C |
| Sample Form Compatibility | Solids (bulk, metallic, powder, film), liquids, gels, pastes, and thermal insulation materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 3.75 mm (Probe #1) or 30 mm × 30 mm × 7.5 mm (Probe #2) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Duration | ≤160 s |
| Power Consumption | <300 W |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Temperature Range | 10–200 °C (Max. 200 °C) |
| Internal Chamber Dimensions | W800×H1200×D800 mm / W1300×H1200×D1100 mm / W2000×H1500×D1000 mm / W1000×H1000×D1000 mm |
| Control System | Programmable Temperature Controller with Paperless Data Logger (DAQ Station CX-1000) |
| Heater Regulation | SCR Thyristor Regulator |
| Cooling System | Water-Cooled or Air-Cooled Chiller (0.75 kW) |
| Safety Features | Dual Overheat Prevention Regulators, Redundant Thermal Cut-offs |
| Energy Efficiency | Optimized Thermal Insulation & Inverter-Driven Circulation |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HM410 |
| Pricing | Available Upon Request |
| Brand | Edmund Bühler |
|---|---|
| Origin | Germany |
| Model | MSP60 |
| Vacuum Chamber | High-vacuum compatible (≤1×10⁻⁵ mbar) |
| Copper Wheel Diameter | 250 mm (solid, optionally water-cooled) |
| Wheel Tilt Adjustment | Continuous angular control for optimized melt jet impingement |
| Crucible Options | 3-piece boron nitride crucible with adapter |
| RF Generator Power | 12 kW or 25 kW (configurable) |
| Temperature Monitoring | Pyrometer range 500–1700 °C (calibration traceable to NIST standards) |
| Melt Volume Capacity | 5–10 g per run |
| Cooling Rate | >10⁶ K/s (typical for amorphous ribbon formation) |
| Control Interface | Integrated touchscreen HMI with real-time display of wheel speed, RF power, melting duration, vacuum level, and pyrometer feedback |
| Auxiliary Systems | Recirculating chiller (required), compressed air supply (4–6 bar), turbo-molecular or diffusion pump train |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-10 |
| Price Range | USD 13,500–40,500 (FOB) |
| Instrument Type | Transient Plane Source (TPS) Method |
| Dimensions (L×W×H) | 250 × 200 × 85 mm |
| Accuracy | ±0.001 W/m·K (for VIP range) |
| Thermal Conductivity Range | 0.001–0.015 W/m·K (VIP materials) |
| Repeatability | ±5% (relative) |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EB 01-II |
| Max Operating Temperature | 300 °C |
| Chamber Configuration | 4 identical-temperature zones |
| Sample Capacity | 24 standard specimens per chamber |
| Temperature Uniformity | ±0.5 °C |
| Heating Method | Channelled aluminum block preheating |
| Airflow | Natural convection, low-velocity, no forced circulation |
| Compliance | IEC 60811-1-2, ISO 188, ASTM D573 |
| Software Interface | PC-connected, wireless data acquisition via laser-guided arm and digital calipers |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EP 04-II |
| Max Operating Temperature | 300 °C |
| Internal Volume | 60 L |
| Air Exchange Rate | Adjustable 3–20 air changes per hour |
| Compliance | IEC 60811, ISO 188 |
| Chamber Airflow | Controlled forced convection |
| Optional Accessories | EB 04AP (external sensor port), EB 04IIW (viewing window with illumination), EB 04IIDC (door interlock safety switch) |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 02II |
| Standards Compliance | ISO 1432, ASTM D1053 |
| Test Stations | 6 independent automated stations |
| Temperature Control | Computer-regulated ramp (–70 °C to +100 °C, optional LN₂ cooling) |
| Output Parameters | RM2, RM5, RM10, RM100 torsional rigidity indices |
| Data Presentation | Real-time graphical curves + tabular export |
| Software | Windows-based control & analysis suite with audit trail capability |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 05II |
| Compliance Standards | ISO 812, ISO 974, ASTM D746, ASTM D2137 |
| Operating Pressure | 6 bar compressed air required |
| Test Principle | Instrumented drop-weight impact with controlled thermal conditioning |
| Temperature Control | Computer-regulated cryogenic chamber (–70 °C to +50 °C typical range) |
| Impact Velocity Measurement | High-speed optical sensor with pre- and post-impact velocity verification |
| Energy Delivery | Adjustable via drop height and calibrated hammer mass |
| Software | Windows-based control & analysis suite with audit trail and report generation |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | ET 06BASEII |
| Temperature Range | −80 °C to +20 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Heating Rate | 1 °C/min |
| Cooling Rate | 0.5 °C/min |
| Temperature Resolution | 0.1 °C |
| Test Stations | 6 |
| Compliance | ISO 2921, ASTM D1329, ISO 812, ASTM D746, ISO 2818 (Gere twist), ASTM D1043 |
| Brand | Elastocon |
|---|---|
| Origin | Sweden |
| Model | EV 01 |
| Compliance | ISO 23529 (Thickness), ISO 815 (Compression Set) |
| Measurement Range | 0–10 mm (with 10 mm reference spacer included) |
| Resolution | 0.001 mm |
| Interface | RS-232 or USB (via optional EC 01.04 interface kit) |
| Software | EC 02 v3.x for data logging, statistical analysis, trend plotting, and report generation |
| Calibration | Traceable to NIST-equivalent national standards (per ISO/IEC 17025-accredited calibration certificate available) |
| [Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #455 |
| Pricing | Available Upon Request] |
| Key | Load Capacity: 100 kg |
|---|---|
| Table Dimensions (Vertical) | 50×20×50 cm (L×H×W) |
| Table Dimensions (Horizontal) | 50×26.5×50 cm (L×H×W) |
| 台面尺寸 (Table Top) | 50×50 cm (L×W) |
| Vibration Axes | Vertical (Z-axis) and Horizontal (X/Y-axes) |
| Frequency Range | 1–600 Hz (standard), up to 5000 Hz (customizable) |
| Sweep Mode | Linear/logarithmic bidirectional sweep with user-defined start/stop frequencies and dwell time |
| Programmable Mode | 15-segment profile, each segment configurable for frequency and duration, repeatable |
| Tuning Mode | Frequency tuning within range under acceleration ≤20 g and displacement ≤5 mm p-p |
| Octave Mode | 15-step octave-up, octave-down, or up-down-up sequences |
| Logarithmic Mode | Three-directional log-sweep (low→high, high→low, low→high→low), repeatable |
| Motor Power | 2.2 kW |
| Peak Displacement | 0–5 mm p-p (adjustable) |
| Peak Acceleration | 20 g (max) |
| Waveform | Sinusoidal |
| Time Resolution | 1 s (programmable) |
| Frequency Display Resolution | 0.01 Hz |
| Frequency Accuracy | ±0.1 Hz |
| Power Supply | 220 V ±20%, 5 A max |
| Acceleration–Displacement Relationship | aₚₑₐₖ = 0.002 × f² × D (with aₚₑₐₖ in g, f in Hz, D in mm p-p) |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 3,600 (excl. tax & freight) |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (W × H × D) |
| Oscillating Pipe Radius | 375 mm |
| Pipe Diameter | Ø15 mm |
| Swing Angle Range | ±45° to ±90° adjustable |
| Nozzle Diameter | Ø0.4 mm or Ø0.8 mm |
| Nozzle Spacing | 50 mm |
| Rainfall Intensity | 600–3600 mm/h |
| Turntable Speed | 1–10 rpm |
| Timer Range | 1 s to 99 h 99 m 99 s |
| Rain Cycle Duration | 1 s to 99 h adjustable |
| Protection Features | Leakage current protection, short-circuit/overload protection, low-water-level alarm, grounding protection (R ≤ 4 Ω) |
| Construction | Outer cabinet — ST12 cold-rolled steel with phosphating + powder coating |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 1–5000 Hz |
| Max. Load Capacity | 150 kg |
| Adjustable Amplitude | 0–5 mm peak-to-peak |
| Acceleration Range | 0–20 g |
| Drive Power | 2.2 kW |
| Input Voltage | 220 V, 50 Hz |
| Vibration Axes | Vertical (Y), Horizontal (X/Z), or Triaxial (X/Y/Z) |
| Waveform | Sine (half/full cycle), programmable |
| Sweep & Logarithmic Modes | 3-directional sweep profiles with 15-segment frequency stepping |
| Programmable Test Sequences | Up to 15 user-defined segments with independent time/frequency/acceleration/amplitude settings |
| Control Interface | Integrated digital controller + optional PC-based software with real-time waveform monitoring, data logging, and report generation (compliant with ISO 10816, ASTM D999, IEC 60068-2-6, MIL-STD-810H) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Moving Mass | 18 kg |
| Table Diameter | 280 mm |
| Max Eccentric Moment | 300 N·m |
| Dimensions (Shaker) | 990 × 990 × 790 mm |
| Weight (Shaker) | 1600 kg |
| Frequency Range | 5–3000 Hz |
| Rated Sinusoidal Force | 14.2 kN |
| Rated Random Force (RMS) | 14.2 kN RMS |
| Max Acceleration | 784 m/s² (80 g) |
| Max Velocity | 2.00 m/s |
| Max Displacement (p-p) | 51 mm |
| Max Payload | 300 kg |
| Power Amplifier Output | 20 kVA |
| Amplifier Dimensions | 550 × 1700 × 800 mm |
| Amplifier Weight | 390 kg |
| Amplifier Type | Switching Mode |
| Total System Power Requirement | 28 kVA |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.3–1993, GB/T 2423.10–1999, JJG 190–1997 |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Max. Sinusoidal & Random Force | 19,600 N (2,000 kgf) |
| Frequency Range (Vertical) | 5–3,000 Hz |
| Rated Acceleration (No Load) | 980 m/s² (100 g) |
| Rated Velocity | 1.85 m/s |
| Peak-to-Peak Displacement | 51 mm |
| Maximum Payload | 300 kg |
| Moving Mass | 22 kg |
| Continuous Operation Time | 20 h |
| Operating Environment | 0–40 °C, ≤90% RH (at 25 °C) |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 3200 Series |
| Frequency Range | 0.0001 – 300 Hz |
| Force Capacity Options | ±225 N or ±450 N (standard) |
| Optional Torsion Motor | 14 N·m or 25 N·m |
| Optional Linear Extension | +150 mm stroke |
| Encoder Resolution | High-resolution optical encoder (torsion mode, up to 62 revolutions) |
| Environmental Compatibility | Integrated with temperature chambers, saline baths, and bioreactors |
| Sensor Range | ±0.002 N to ±450 N (interchangeable load cells) |
| Drive Type | Direct-drive linear electromagnetic motor |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ElectroForce® 5500 |
| Frequency Range | 0.0001 – 20 Hz |
| Force Control Range | ±0.002 N to ±200 N |
| Architecture | Single-Beam Open-Frame Design |
| Environmental Compatibility | Compatible with Incubators & Gloveboxes |
| Optional Fixture | 24-Well Compression Fixture for Multi-Specimen Testing |
| Key Features | Electromagnetic excitation |
|---|---|
| Max. load capacity | 100 kg |
| Frequency range | 1–600 Hz (standard), up to 5000 Hz (optional) |
| Max. acceleration | 20 g |
| Adjustable amplitude | 0–5 mm peak-to-peak |
| Power | 2.2 kW / 3.8 kW |
| Input voltage | 220 V / 380 V AC |
| Platform dimensions | 50 cm × 50 cm (customizable) |
| Unit footprint options | 50×20×50 cm, 50×25×20 cm, 50×25×50 cm (dual-platform configurations available) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Table Surface | 500 × 500 mm |
| Axis Configuration | Vertical + Horizontal Dual-Axis |
| Max. Payload | 50 kg |
| Frequency Range | 1–200 Hz |
| Adjustable Frequency Range | 1–200 Hz (continuous, stepless) |
| Sweep Mode | Programmable linear or logarithmic sweep between user-defined upper/lower limits (e.g., 10–60 Hz, duration 1 min) |
| Peak-to-Peak Displacement (unloaded) | 0–5 mm (amplitude varies with frequency |
| Timing Resolution | 1 s |
| Max. Timing Duration | 99 h 99 m 99 s |
| Drive Power | 2.2 kW |
| Input Voltage | 220 V ±10% AC, 50/60 Hz |
| Max. Current Draw | 5 A |
| Control Architecture | Decoupled controller-shaker design with isolated signal/power paths |
| Compliance | IEC 60068-2-6, ISO 10816-1, ASTM D999, MIL-STD-810H (vibration sections) |
| Key | Table Surface Dimensions: 350×350 / 500×500 / 750×750 / 1000×1000 mm |
|---|---|
| Shaker Body Dimensions (Vertical) | 500×200×500 mm |
| (Horizontal) | 500×250×500 mm |
| Vibration Axes | Vertical (Y) + Horizontal (X) |
| Frequency Range | 1–3000 Hz, Resolution: 0.01 Hz |
| Peak-to-Peak Displacement | 0–5 mm adjustable |
| Maximum Load Capacity | 75 kg |
| Peak Sinusoidal Force | 1500 kgf (≈14.7 kN) |
| Maximum Acceleration | ≤20 g |
| Waveform | Sine (full- or half-wave) |
| Programmable Test Segments | 15 |
| Sweep Modes | Linear, Logarithmic, Step, Octave |
| Time Setting Range | 0–999,999 s |
| Power Consumption | 3.8 kW |
| Input Voltage | 380 V ±20%, 3-phase |
| Rated Current | 10 A |
| Operating Temperature | −10°C to +60°C, Humidity ≤95% RH (non-condensing) |
| Recommended Ambient | ≤28°C with adequate ventilation |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Frequency Range | 1–5000 Hz (±0.01 Hz resolution) |
| Max Load Capacity | 100 kg |
| Peak Force | 2000 kgf |
| Table Size | 500 × 500 × 6 mm (L×W×H) |
| Table Mounting | 25 × M10 threaded holes + 16 × hook slots (70 mm length) |
| Motion Axes | 6-DOF synchronized or selectable 1–3 axis operation |
| Waveforms | Sine (half/full), multi-stage random, road profile simulation, logarithmic sweep, programmable step/segment profiles (15-segment max) |
| Control Modes | Fixed-acceleration sweep, fixed-amplitude sweep, harmonic倍频, linear/logarithmic sweep, time-controlled dwell, amplitude & acceleration modulation |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,800 (FOB) |
| Frequency Range | 10–400 Hz |
| Max. Load Capacity | 100 kg |
| Displacement Amplitude | 0.5–5 mm (peak-to-peak) |
| Driving Principle | Electromagnetic Force Actuation |
| Control Interface | RS-485 Optional |
| Compliance | GB/T 13310-1991, GB/T 2423.10-1995, JJG 190-1997, IEC 60068-2-6 |
| Cooling Method | Natural Convection |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Table Size | 50 × 50 cm |
| Moving Mass | 50–100 kg |
| Input Power | 2.2–3.0 kVA |
| Waveform Options | Sine, Half-Sine |
| Optional Accessories | Amplitude & Acceleration Display Unit, PC-Based Vibration Controller, Thermal-Stable Voltage Regulator, Serial Printer Interface |