Physical Property Testing Instruments
Filter
Showing 241–270 of 12188 results
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AMI-300HP High-Pressure Chemisorption Analyzer (100 bar) |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable up to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar / 100 bar (dual-range configuration) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira |
|---|---|
| Origin | USA |
| Model | AMI-300S Corrosion-Resistant Chemisorption Analyzer |
| Testing Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional 100 bar) |
| Analytical Capabilities | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | CGS-3 MD |
| Laser Wavelength Options | 660 nm (50 mW DPSS) or 532 nm (50 mW Nd:YAG) |
| Detector Configuration | 4 or 8 parallel APD/PMT detectors |
| Angular Spacing | 16° between adjacent detectors (8-detector mode) |
| Correlator | One or two ALV-7004 multi-tau digital autocorrelators (supporting 4- or 8-channel operation) |
| Application Focus | Time-resolved static and dynamic light scattering (SLS/DLS) of rapidly evolving colloidal, polymeric, and biomolecular systems |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV-CorrTector-II |
| Detector Type | Integrated Avalanche Photodiode (APD) with Multi-τ Digital Correlator |
| Count Rate | >80 Mcps |
| Dark Count Rate | ~250 cps |
| Afterpulsing | Minimized with Embedded Correction Algorithm |
| Peak Quantum Efficiency | 60% |
| QE at 488 nm | 53% |
| QE at 532 nm | 40% |
| Operating Temperature Range | 15–35 °C |
| Dimensions | 120 × 58 × 30 mm |
| Weight | 250 g |
| Interface | Mini-USB 2.0 |
| OS Compatibility | Windows 10 (64-bit) |
| Power Consumption | <2 W |
| Brand | ALV |
|---|---|
| Origin | Germany |
| Model | ALV/CGS-3 |
| Laser Source | 50 mW DPSS, 660 nm |
| Angular Range | 12°–152° |
| Angular Resolution | ±0.025° |
| Angular Accuracy | 0.003° at 25.000° |
| Detector | Dual APD (QE >65% @ 660 nm) |
| Correlation Method | Heterodyne quasi-cross-correlation & auto-correlation |
| Sample Cell | 85 mm OD quartz, centering ≤±5 µm, orthogonality ≤±10 µm, AR-coated 0°/180° windows |
| Temperature Control | Up to 70°C standard |
| Sample Volume Options | Standard cuvette + 5 mm NMR tube adapter |
| Attenuation | 8-step motorized optical density selection |
| Safety Class | EN 60825-1:2014 Class 1 (operational) |
| Compliance | GLP-ready architecture, audit-trail-capable software framework |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AI DC-48 |
| Pricing | Upon Request |
| Maximum Raw Storage Capacity | 768 TB |
| Drive Bay Count | 48 hot-swappable 3.5" SATA/SAS bays |
| Per-Drive Capacity | Up to 16 TB |
| Processor | Intel Xeon Scalable Series (multi-core) |
| Memory | 64 GB DDR4 ECC Registered RAM |
| Network Interface | Dual-port 10 GbE SFP+ with LACP support |
| Data Management Features | Hierarchical metadata tagging, spatial location indexing, thumbnail-based dataset preview, DICOM-compliant query engine, role-based access control (RBAC), automated backup scheduling |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AI-1000 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| X-ray Energy | 80 kV |
| Maximum Sample Diameter | 250 mm |
| Maximum Sample Height | 350 mm |
| Sample Weight Capacity | 5 kg |
| System Dimensions (W×D×H) | 1100 × 660 × 660 mm |
| Contrast Resolution | <1% |
| Minimum Detectable Defect Size | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight | 350 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | AI-2000CT |
| Detector Type | Flat-Panel Detector |
| X-ray Energy | 195 kV |
| Maximum Sample Diameter | 500 mm |
| Maximum Sample Height | 500 mm |
| Maximum Sample Weight | 20 kg |
| System Dimensions (W×D×H) | 1900 × 1000 × 1600 mm |
| Contrast Resolution | <1% |
| Spatial Resolution (Defect Detection Limit) | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight Range | 1500–5000 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AI-3000CT |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| X-ray Energy Options | 250 kV / 320 kV / 450 kV |
| Maximum Sample Dimensions | Ø600 mm × H1000 mm |
| Maximum Sample Weight | 50 kg |
| System Dimensions (L×W×H) | 3500 mm × 2100 mm × 2250 mm |
| Contrast Resolution | <1% |
| Spatial Resolution (Defect Detection Limit) | 0.1 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight | 5000–6000 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AI-4000CT |
| X-ray Energy | 450 / 500 / 600 kV |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Max Sample Diameter | 1200 mm |
| Max Sample Height | 1500 mm |
| Max Payload | 100 kg |
| System Dimensions (L×W×H) | 4000 × 2600 × 3000 mm |
| Contrast Resolution | <1% |
| Spatial Resolution (Defect Detection Limit) | 0.1–0.2 mm |
| Radiation Leakage | <1 µSv/h |
| Net Weight | 10,000–15,000 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AX-1000CT |
| X-ray Source | Microfocus Closed-Tube (80 kV / 100 kV) |
| Detector Type | Flat-Panel Detector |
| Scan Geometry | Translation-Rotation (TR) |
| Spatial Resolution | 5 µm (high-res mode) / 40 µm (standard mode) |
| Field of View | Ø250 mm × H350 mm |
| Sample Weight Capacity | 5 kg / 10 kg (configurable) |
| System Dimensions (L×W×H) | 1100 mm × 660 mm × 600 mm |
| Radiation Leakage | <1 µSv/h at 100 mm from enclosure surface |
| Contrast Resolution | <1% (per ASTM E2737-22) |
| Net Weight | 350 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AX-2000CT |
| Price Range | USD 210,000 – 350,000 (FOB) |
| Detector Type | Digital Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 0.5 µm (with optional nanofocus source & optical coupling) |
| Density Resolution | <1% contrast sensitivity |
| X-ray Energy | 160 kV / 180 kV (configurable up to 200 kV) |
| Maximum Sample Diameter | 320 mm |
| Maximum Sample Height | 500 mm |
| Maximum Sample Weight | 10 kg (standard), 50 kg (optional rotary stage) |
| System Dimensions (W×D×H) | 1950 × 1050 × 1650 mm |
| System Weight | 1500–2000 kg |
| Radiation Leakage | <1 µSv/h at 1 m |
| X-ray Source | Open-tube transmission target microfocus (1.5 µm focal spot) or nanofocus (0.8 µm focal spot) |
| Tube Current Range | 0.01–0.5 mA |
| Max. Tube Power | 80 W |
| Cooling Method | Air-cooled |
| Detector Pixel Size | 139 µm |
| Detector Array | 3072 × 3072 pixels |
| Field of View (FOV) | 427 × 427 mm |
| Optional Detector | Fiber-optic coupled scintillator with 4×/10×/20× magnification lenses |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AX-2000PCT |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Micron-level (10–40 µm) |
| X-ray Energy | 160 kV / 180 kV |
| Maximum Sample Dimensions (L×W×H) | 400 mm × 400 mm × 50 mm |
| Maximum Sample Weight | 5 kg |
| System Dimensions (W×D×H) | 1950 mm × 1050 mm × 1650 mm |
| Focal Spot Size | ≤1.5 µm |
| Pixel Pitch | 85 µm / 100 µm |
| Detector Active Area | 130 mm × 130 mm / 200 mm × 200 mm |
| Detector Pixel Matrix | 1536 × 1536 / 2048 × 2048 |
| Max Tube Current | 0.5 mA |
| Contrast Sensitivity | <1% |
| System Net Weight | 1500–2000 kg |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AX-3000CT |
| Detector Type | Digital Flat-Panel Detector (139 µm pixel pitch, 3072 × 3072 pixels) |
| Scan Mode | Rotation-Only (RO) |
| Accuracy | Micron-Level |
| X-ray Energy | 225 kV / 240 kV / 300 kV |
| Penetration Capability | Sample-Dependent |
| Spatial Resolution | 1.5–2 µm (with optional 180 kV source down to 800 nm) / 3.5 µm |
| Density Resolution | <1% |
| Maximum Specimen Dimensions | Ø600 mm × H800 mm |
| Dimensional Measurement Accuracy | Sample-Dependent |
| Density Measurement Accuracy | Sample-Dependent |
| Max. Sample Weight | 25 kg / 50 kg / 100 kg |
| System Dimensions | 2950 × 1650 × 1950 mm |
| System Weight | 6000 kg |
| Radiation Shielding | Integrated Lead-Lined Enclosure (<1 µSv/h outside cabinet) |
| Cooling | Water-Cooled X-ray Source (500 W max power) |
| Focal Spot Size | 3–5 µm (standard), down to 800 nm (optional 180 kV reflective target) |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | AX-3000CT-D |
| Detector Type | Digital Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | 1.5–2 µm / 3–4 µm |
| Density Resolution | <1% |
| X-ray Energy | 160–300 kV (dual-source configurable: e.g., 180 kV + 240 kV) |
| Maximum Sample Dimensions | Ø600 mm × H1000 mm |
| Sample Weight Capacity | 50 kg / 100 kg / 200 kg |
| System Footprint | 3500 mm × 2000 mm × 2300 mm |
| Focal Spot Size | ≤1.5 µm (nano-focus mode, 180 kV) / ≤4 µm (micro-focus mode, 240–300 kV) |
| Detector Pixel Pitch | 100–200 µm |
| Detector Array Size | Up to 3072 × 3072 pixels |
| Field of View | Up to 427 mm × 427 mm |
| Radiation Shielding | Integrated walk-in lead-lined room (<1 µSv/h ambient dose rate) |
| Brand | Always Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AX-3000CT-M |
| Detector Type | Digital Flat-Panel Detector |
| Scan Mode | Rotation-Only (RO) |
| Accuracy | Micron-Level |
| X-ray Energy | 225 kV / 240 kV / 300 kV |
| Penetration Capability | Sample-Dependent |
| Spatial Resolution | 1.5–2 µm (high-resolution mode) / 3.5 µm (standard mode) |
| Density Resolution | <1% |
| Maximum Sample Dimensions | Ø600 mm × H800 mm |
| Dimensional Measurement Accuracy | Sample-Dependent |
| Density Measurement Accuracy | Sample-Dependent |
| Sample Weight Capacity | 25 kg / 50 kg / 100 kg (configurable) |
| System Footprint | 2950 × 1650 × 1950 mm (L×W×H) |
| Shielding | Integrated Lead-Lined Enclosure Compliant with GBZ 130-2020 |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AX-4000CT |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | 3–5 µm / 3–5 lp/mm |
| Density Resolution | <1% |
| X-ray Energy Options | 225 kV / 240 kV / 300 kV (microfocus source) |
| Maximum Sample Dimensions | Ø1000 mm × H1200 mm |
| Sample Weight Capacity | 50 kg / 100 kg / 200 kg |
| System Footprint | 4000 mm × 2600 mm × 3000 mm |
| Focal Spot Size | ≤5 µm (microfocus), 0.4 mm / 1 mm (high-energy source) |
| Detector Pixel Sizes | 139–200 µm (flat-panel) |
| Pixel Count | up to 4096 (line-array), 2048×2048–3072×3072 (flat-panel) |
| Field of View | up to 427×427 mm (flat-panel), 400–800 mm effective length (line-array) |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AX-5000CT |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Accuracy | Millimeter-level |
| X-ray Energy | 30–450 kV / 500 kV / 600 kV |
| Spatial Resolution | 3 µm / 3–5 lp/mm |
| Density Resolution | <1% contrast sensitivity |
| Maximum Sample Dimensions | Ø1000 mm × H1500–2500 mm |
| Sample Load Capacity | 100 kg / 200 kg / 500 kg (customizable up to 1000 kg) |
| System Footprint | 3500 mm × 1000 mm × 2600 mm |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AX-8000CT |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≥5 lp/mm (high-resolution mode), ≥2 lp/mm (high-penetration mode) |
| X-ray Energy Options | 1, 2, 4, 6, 9, 12, or 15 MeV selectable |
| Inspection Field of View (FOV) | 1000–1500 mm × 1500–2500 mm (customizable) |
| Maximum Sample Weight Capacity | 500–2000 kg (customizable) |
| System Footprint | Fully customizable per facility integration requirements |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Micron-Level |
| X-ray Energy Options | 130 / 160 / 180 / 200 kV |
| Maximum Sample Footprint | 400 × 400 mm or 650 × 650 mm (customizable) |
| System Footprint | 2267 × 2062 mm |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | 160 RT |
| X-ray Energy Options | 160 kV / 225 kV / 240 kV / 300 kV |
| Brand | Always Imaging |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TT-160 Integrated |
| X-ray Energy | 160 kV / 180 kV / 200 kV / 225 kV / 240 kV / 300 kV |
| Max. Tube Voltage | 160 kV |
| Max. Tube Current | 0.5 mA |
| Max. Power (Water-cooled / Air-cooled) | 80 W / 25 W |
| Minimum Focal Spot Size (JIMA) | 1.5 µm |
| Minimum Detail Resolution | <1 µm |
| Anode Target Type | Transmission |
| X-ray Cone Angle | 170° |
| Window Material | 0.3 mm Carbon |
| Controller Form Factor | 19″ 2U Rack-mountable, Integrated High-Voltage Generator |
| Maintenance Requirement | Maintenance-free Operation |
| Brand | AMAE |
|---|---|
| Model | MI-200 |
| Flow Table Diameter | 254 mm ± 2.5 mm |
| Flow Table Thickness | 8 mm ± 0.1 mm |
| Drop Height | 12.5 mm ± 0.13 mm |
| Vibration Frequency | 25 Hz |
| Stroke Count Range | 1–9999 cycles (programmable) |
| Material | Brass flow table (Rockwell hardness ≥ HRB 25) |
| Compliance | ASTM C230-68, IMSBC Code Annex 1 (Moisture Content Testing for Flow Potential Assessment) |
| Sample Size Range | 1 mm ≤ particle size ≤ 7 mm |
| Environmental Requirement | Controlled temperature & humidity chamber, draft-free operation |
| Brand | AMAE |
|---|---|
| Model | MI-600 |
| Origin | Guangdong, China |
| Drive System | Hydraulic Accumulator |
| Tilt Range | 0–50° |
| Tilt Speed | Adjustable ≤ 0.3°/s |
| Angular Resolution | ≤ 0.5° |
| Test Chamber Dimensions | 600 × 400 × 200 mm (L×W×H) |
| Hydraulic Accumulator Dimensions | 500 × 500 × 450 mm (L×W×H) |
| Weight | 150 kg |
| Max Hydraulic Pressure | < 50 kPa/cm² |
| Sample Type | Non-cohesive granular solids ≤ 10 mm particle size |
