| Brand | Ambrell |
|---|---|
| Origin | USA |
| Model | 0112 |
| Frequency Range | 150–400 kHz |
| Power Output | 1–10 kW |
| Power Control Resolution | ±25 W |
| Cooling | Integrated Water-Cooling System |
| Heating Head Cable Length | Standard 3 m (extendable) |
| Display Languages | English, French, Italian, German, Spanish |
| Compliance | CE, UL Listed |
| Remote Interface | RS-232/RS-485 Serial Port |
| Programmable Profiles | Up to 4 user-defined heating modes |
| Optional Accessories | Optical Pyrometer (for closed-loop temperature control), Chiller/Heat Exchanger, PLC Interface Module, Foot Switch, Extended Cable Kits |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Model | EasyHeat |
| Frequency Range | 150–400 kHz |
| Power Output | 1.2–10.0 kW |
| Input Voltage | 105–250 V (1-phase) / 187–520 V (3-phase) |
| Input Apparent Power | 1.6–12.4 kVA |
| Compliance | CE, UL Listed, RoHS Compliant |
| Software | eVIEW™ Process Monitoring & Control Suite |
| Architecture | Versatile Platform Architecture (VPA) |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Manufacturer Type | Industrial Induction Heating System Manufacturer |
| Model | EkoHeat Series (Custom-Configured) |
| Power Rating | 6 kW (typical for lab-scale silicon melting) |
| Operating Frequency | 196 kHz |
| Compliance | CE, UL 508A, RoHS |
| Application Scope | Lab-scale to pilot-scale non-contact induction melting |
| Sample Capacity | 0.7 g to >100 kg (configurable) |
| Crucible Compatibility | Graphite, quartz, ceramic, refractory-lined |
| Thermal Control Precision | ±5 °C (with integrated thermocouple feedback loop) |
| Cooling | Integrated forced-air or optional water-cooling |
| Software Interface | EkoControl™ v4.2 with real-time power/temperature logging and recipe management |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ambrell EKOHEAT® Series |
| Pricing | Available Upon Request |
| [Brand | AMETEK Chatillon |
|---|---|
| Origin | USA |
| Model | DFS2-R-ND |
| Accuracy | ±0.25% of full scale |
| Display | High-resolution LCD, backlit |
| Measurement Modes | Real-time, Peak Hold, Pass/Fail, Statistical Averaging, Load Comparison, Break Detection |
| Units | lbf, ozf, gf, kgf, N (force) |
| Interface | RS-232 |
| Compliance | NIST-traceable calibration certificate available |
| Software | Optional NEXYGEN DF Suite |
| Sensor Compatibility | SLC series load cells (tension/compression), STS series torque sensors |
| Auto-sensing | Automatic transducer identification] |
| Brand | AMPTek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3D Force Measurement System |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | ARB-IPR-1210 (PCI-E) |
| Bus Interface | PCI Express |
| ADC Resolution | 12-bit |
| Sampling Rate | 100 MSPS (selectable: 100/50/25/10/5 MSPS) |
| Input Bandwidth | 0.5–30 MHz (+3 dB) |
| Gain Range | –20 to +80 dB (0.1 dB step) |
| Pulse Generator | Up to 400 V peak (<5 ns rise time), programmable pulse width & damping |
| DAC Memory | 128 KB RAM (64K points) |
| Trigger Modes | Software, external TTL, signal threshold |
| Gate Count | 4 independent gates |
| Time-of-Flight Resolution | 16-bit (10 ns) |
| Amplitude Resolution | 12-bit (488 µV) |
| Operating Temperature | 5–40 °C |
| Form Factor | Full-length PCI-E card |
| Compliance | RoHS, CE, FCC Class A |
| Software Support | LabVIEW and C++ drivers included |
| Standards Compatibility | Designed for ASTM E1158, ISO 12718, and EN 12668-1 compliant ultrasonic testing workflows |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | Cheetah EVO |
| Detector Type | Flat-panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| X-ray Energy | 160 kV |
| Penetration Capability | Up to 350 mm steel-equivalent thickness |
| Precision | Nanoscale |
| Optional Features | Water-cooled X-ray tube (FXT 160.51), High-load capacity (< 20 kg), Low-dose imaging mode, Dose-reduction kit for sensitive components |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Type | Industrial Micro-CT System |
| Model | FF20 CT |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| X-ray Source | 190 kV Water-Cooled Nanofocus Transmission Tube |
| Spatial Resolution (2D) | ≤150 nm |
| Sample Size Capacity | Small to Medium |
| System Dimensions | 2380 × 945 × 2180 mm |
| Base Material | Precision Granite |
| User Interface | Gemini Touchscreen GUI |
| Software Features | HeliExtend Spiral CT, Virtual Rotation Axis, Field-of-View Extension (Horizontal/Vertical), QuickScan & QualityScan Modes |
| Measurement Capabilities | Dimensional Metrology (CT-based GD&T), Defect Detection (<1 µm), Density Quantification, Assembly Verification, Porosity & Inclusion Analysis |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | FF35 |
| Detector Type | Flat-Panel Detector |
| Scan Mode | Translation-Rotation (TR) |
| X-ray Energy | 225 kV (microfocus) / 190 kV (nanofocus) |
| Maximum Penetration | 350 mm steel-equivalent |
| Spatial Resolution | up to 2.5 lp/mm |
| Density Resolution | up to 2.5 lp/mm |
| Measurement Accuracy (Metrology Version) | MPESD = 5.9 µm + L/75 [L in mm] |
| Sample Weight Capacity | up to 50 kg |
| Compliant Standards | SEMI® S2-0818, SEMI® S8-0218, VDI/VDE 2630 |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | FF85 CT |
| Detector Type | Flat-Panel Detector (FPD) & Linear Detector Array (LDA) |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 450 kV (dual-source: up to 600 kV microfocus + 300 kV minifocus) |
| Penetration Capability | 60 mm steel equivalent |
| Measurement Accuracy (Dimensional) | 0.001 mm |
| Density Measurement Accuracy | Up to 0.2% |
| Sample Weight Capacity | 100 kg |
| Max Sample Dimensions | Ø800 mm × H1100 mm |
| System Dimensions | 3700 mm × 2300 mm × 2800 mm (L×W×H) |
| Base Material | Precision Granite |
| Motion Axes | 7-axis motorized manipulator |
| Software Platform | Gemini CTScan Suite (including CTScan 3 LDA support, HeliExtend, ScatterFix 2.0, BHC, MAR) |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis Instruments, Inc. |
| Type | Imported |
| Model | GN1500HS |
| Pricing | Available upon Request |
| Brand | Analysis |
|---|---|
| Model | PM1121 |
| Detection Principle | Geiger-Müller (GM) Tube-Based Ionizing Radiation Monitoring |
| Measurement Range | 0.01–10,000 µSv/h (Dose Rate), 0.01 µSv–9999 mSv (Cumulative Dose) |
| Energy Response | 40 keV–3 MeV |
| Sensitivity | >6000 CPM per µSv/h (relative to ¹³⁷Cs) |
| Alarm Response Time | ≤5 s |
| Operating Temperature | −15°C to +50°C |
| Power Supply | 2×AA batteries (alkaline or rechargeable) |
| Weight | 0.3 kg |
| Dimensions | 135 × 70 × 25 mm |
| Compliance | Designed for IEC 60846-1:2014 (Radiation Protection Instruments – Dose Rate and Dose Meters for Photon Radiation) and compatible with GLP/GMP field-use requirements |
| Brand | Analysis |
|---|---|
| Model | PM1121 |
| Detector Type | Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.01–10,000 µSv/h (dose rate), 0.01 µSv–9999 mSv (cumulative dose) |
| Energy Response | 40 keV–3 MeV |
| Sensitivity | >6000 cps per µSv/h (relative to ¹³⁷Cs) |
| Alarm Response Time | ≤5 s |
| Operating Temperature | −15°C to +50°C |
| Dimensions | 135 × 70 × 25 mm |
| Weight | 0.3 kg |
| Power Supply | Two AA batteries (alkaline or rechargeable) |
| Typical Current Draw | ≤4 mA |
| Display | Dot-matrix LCD with backlight |
| Language Options | English, Chinese, Japanese |
| Compliance | Designed for IEC 61526:2010 (Radiation protection instrumentation — Measurement of personal dose equivalents Hp(10) and Hp(0.07)) and compatible with national occupational radiation safety standards |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Remote-UT |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Dimensions (Module) | 25 × 15 × 7.5 cm |
| Architecture | Embedded PC-based Distributed System |
| Signal Interface | Gigabit Ethernet |
| Compliance | ASTM E317, ISO 16810, EN 12668-1/2/3, ASME BPVC Section V |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Models | T156, T240, T264, T480 |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer | Analysis, Inc. |
| Product Type | Imported |
| Model | TCP Ultrasonic C-Scan System |
| Pricing | Available Upon Request |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 128-105 |
| Channel Capacity | 128 independent DC resistance monitoring channels |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock modules support additional durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Sensing Current Options | 1, 5, 10, 20, 50, 100 mA |
| Max Compliance Voltage | 2.5 V |
| Threshold Tolerance | ±5% |
| Event Detection Sensitivity | 100 ns |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 6 A |
| Dimensions | 11.5" H × 18" W × 15.5" D |
| Weight | 51 lb |
| Interface | USB or RS-232C |
| Software | WinDatalog v5.x for data acquisition, event logging, and statistical analysis |
| Compliance | Designed for GLP/GMP-aligned test environments |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 32-106 |
| Channel Capacity | 32 |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock module supports other durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Channel Test Current | 1, 5, 10, 20, 50, 100 mA |
| Compliance Voltage | ≤2.5 V |
| Threshold Tolerance | ±5% |
| Interface | USB & RS-232C |
| Software | WinDatalog v5.x |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 3 A |
| Dimensions (H×W×D) | 7.5″ × 18″ × 16.5″ |
| Weight | 26 lb |
| Warranty | 1 year parts and labor |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | CTE-360 |
| Temperature Range | –25 °C to +100 °C |
| Compliance | ASTM D696, ASTM E228 |
| Sample Max Cross-Section | 12.5 mm (0.5 in) |
| Recommended Sample Length | 50 mm (2 in) |
| CTE Accuracy | ±3% (full 100 °C range) |
| Power Supply | 100–230 VAC, 50/60 Hz, ≤400 W |
| Dimensions | 43 × 43 × 43 cm (17 × 17 × 17 in) |
| Weight | 9 kg (20 lb) |
| Software | WinCTE v1.x (Windows 7–11, 32/64-bit) |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | Phase12 |
| Heating Current Options | 2 A / 10 A / 20 A / 100 A (Phase12B) |
| Sampling Rate | 1 MHz |
| Temperature Resolution | ±0.007°C (Tj digital), ±0.1°C (display), ±0.2–0.5°C (absolute) |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Heating Voltage Accuracy | ±0.2% rdg + 0.025% FS (50 V) for Phase12 |
| Transient Time Resolution | 1 µs |
| Transient Span | 1 µs – 1000 s |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | PHASE12 |
| Compliance | JEDEC JESD51-1, JESD51-14, JESD51-8, JESD51-12 |
| Thermal Resolution | ±0.007°C |
| Junction Temperature Accuracy | ±0.1°C |
| Voltage Measurement Accuracy | ±0.25% (0–30 V) |
| Current Measurement Accuracy | ±0.25% |
| Sampling Rate | 1 MHz |
| Max Standard Current Output | 18 A |
| Optional High-Current Power Booster | up to 1000 A |
| Junction Sensing Current Options | 1–50 mA |
| Calibration Temperature Range | Ambient to 180°C |
| Input Power | 220 VAC, 5 A, 50/60 Hz |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | STD Event Detectors |
| Pricing | Upon Request |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | STD Event Detectors Accessories |
| Type | Field-Upgradeable Hardware Modules and Interconnect Solutions for Electrical Continuity Interruption Testing |
| Compliance | Designed for use with ASTM F1978, IPC-TM-650 2.6.23, MIL-STD-883H Method 2014, and IEC 60068-2 environmental test correlation workflows |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | TIM1300 / TIM1400 |
| Test Method | ASTM D5470 |
| Sample Diameter | 1.3 in (33 mm) |
| Thickness Range | 0–20 mm |
| Temperature Range | 20–65°C (TIM1300), 20–130°C (TIM1400) |
| Contact Pressure Range | 5–380 psi (34–2600 kPa) |
| Thickness Measurement Accuracy | ±1% + 0.001 in (±25 µm) |
| Thermal Resistance Range | 0.005–8 K/W |
| Power Supply | 100–230 VAC, 50/60 Hz |
| Cooling Requirement | 6 L/min @ 10–35°C, ±0.1°C stability |
| Compressed Air | ≥90 psi (600 kPa), 10 µm filtration |
| Dimensions (H×W×D) | 58×41×43 cm |
| Weight | 19 kg (TIM1300), 21 kg (TIM1400) |
| Brand | ANALYSIS TECH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | TIMTester 1300, TIMTester 1400 |
| Pricing | Upon Request |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | U-AT |
| Instrument Type | Digital |
| Flaw Detection Method | Pulse-Echo |
| Waveform | Pulsed Ultrasonic |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model Variants | UPK-T24, UPK-T36, UPK-T48, UPK-T60, UPK-T72 |
| Water Tank Dimensions (L×W×H) | 600×450×300 mm (UPK-T24) to 4000×4000×900 mm (Custom Large-Format Systems) |
| Motion Axes | 4–8 axes with encoder feedback |
| Positioning Accuracy | ≤ 0.05 mm |
| Maximum Scan Speed | 500 mm/s |
| Ultrasonic Data Acquisition | PCIe-based integrated excitation & 14-bit ADC card |
| Bandwidth | Up to 32 MHz |
| Sampling Rate | 250 MS/s |
| Software Platform | UTwin — Multi-window, multi-modal (A/B/C/3D/CT) scanning and analysis suite |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T156 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 4000 × 1500 × 900 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Model | UPK-T24 |
| Scanning Range | 600 × 450 × 300 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Transducer Configuration | Single-Crystal or Through-Transmission |