Physical Property Testing Instruments
Filter
Showing 2191–2220 of 4517 results
| Brand | IMCE |
|---|---|
| Origin | Belgium |
| Model | LT80 |
| Operating Temperature Range | 77 K to 473 K (Liquid Nitrogen–Free) |
| Cooling Method | Closed-Cycle Mechanical Cryocooler |
| Price | €100,000 |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiSizer 65X |
| Measurement Principle | STEP-Technology (Spatial and Temporal Extinction Profiles) |
| Sample Throughput | 12 positions simultaneously |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (ISO 13318-2) | 20 nm – 100 µm |
| Stability & Sedimentation Velocity Range | 10 nm – 1000 µm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Acceleration Force | 6 × g to 2300 × g |
| Optical Wavelength Options | 470 nm (blue) and 865 nm (NIR) |
| Sample Volume | 0.05 – 2.0 mL |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (via SEPView software audit trail), GLP/GMP-ready |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFrac |
| Quotation | Upon Request |
| Principle | Centrifugal Fracture Testing (Dynamic Load Application via Rotating Rotor) |
| Max. Centrifugal Force Range | 0.1 N – 6.5 kN |
| Rotational Speed Range | 100 – 13,000 rpm |
| Tensile Strength Measurement Range | up to 80 MPa |
| Sample Capacity | 8 parallel specimens |
| Sample Dimensions | max. 30 × 30 × >1 mm³ |
| Bonded Area Diameter | 7 mm, 10 mm or custom |
| Bonded Surface Materials | metallic & non-metallic substrates |
| Specimen Mass Range | 4.1 g – 38.7 g (Cu/W-based reference: ~58 g) |
| Temperature Control Range | −11 °C to +40 °C |
| Measurement Duration | 1 min – 99 h |
| Compliance | ISO 4624, DIN EN 15870, DIN EN 14869-2, JIS K 5600-5-7 |
| Data Interface | USB |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Max. Power Consumption | 1050 W |
| Net Weight | 56 kg |
| Dimensions (W×H×D) | 380 × 296 × 640 mm³ |
| Software Platform | SEPView® v6.x with real-time critical force calculation, statistical comparison, GLP-compliant audit trail, and FDA 21 CFR Part 11-ready user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiFuge |
| Price | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge® |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis under Controlled Centrifugal Force |
| Sample Throughput | Up to 8 samples per run |
| Rotor Speed Range | 0–4,000 rpm (variable, programmable) |
| Detection Method | Polydisperse near-infrared (NIR) light transmission at 870 nm |
| Spatial Resolution | 10 µm per data point across 5 cm sample path |
| Data Acquisition Frequency | Up to 1 scan/s (adjustable) |
| Temperature Control | 5–40 °C (±0.5 °C) |
| Sample Volume per Cell | 0.1–2.0 mL |
| Compliance | ASTM D7713-19 (Standard Practice for Stability Evaluation of Dispersions by Centrifugation), ISO 13321 (Particle Size Analysis – Photon Correlation Spectroscopy), GLP-ready with audit trail and user access control |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LUMiReader PSA |
| Pricing | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader PSA |
| Measurement Principle | STEP Technology™ (Spatial and Temporal Extinction Profiles) |
| Acceleration Method | Gravimetric Tilt Enhancement (0°–30° tilt, up to 10× g-equivalent separation rate) |
| Detection | Multi-wavelength LED array (470 nm, 525 nm, 625 nm, 850 nm) |
| Optical Sensors | >9,000 high-resolution photodiodes per detector |
| Sample Volume | 0.5–4.0 mL |
| Concentration Range | 0.00015–75 wt% |
| Particle Size Range (PSD) | 500 nm–300 µm (ISO 13317 compliant) |
| Stability Assessment Range | 200 nm–2000 µm |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | up to 22 g/cm³ |
| Temperature Control | Ambient +3°C to 60°C (±1 K) |
| Tilt Angles | 0°, 5°, 10°, 15°, 20°, 25°, 30° |
| Minimum Acquisition Interval | 0.5 s |
| Data Output | Extinction profiles (E(z,t)), velocity distribution Qᵥ(v), intensity-weighted PSD Qᵢₙₜ(x), volume-weighted PSD Q₃(x) |
| Compliance | ISO/TR 13097, ISO 13317, ASTM D7827, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP-ready architecture |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 92,000 – 131,500 (converted at ~¥7.6/USD) |
| Sample Capacity | 12 positions |
| Temperature Control | 4 °C to 60 °C (±1 K) |
| Acceleration Range | 6×g to 2300×g |
| Particle Size Range (by STEP-Technology) | 20 nm – 100 μm (stability & sedimentation velocity) |
| Concentration Range | 0.00015 wt% – 90 wt% |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical System | Multi-wavelength transmission scanning (650 nm, optional 470 nm & 870 nm) |
| Measurement Principle | Spatial and temporal extinction profiling (STEP-Technology) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (software audit trail enabled), GLP-ready |
| Sample Volume | 0.05 mL – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 68,000 – 95,000 |
| Sample Capacity | 12 positions |
| Measurement Principle | Spatially Resolved Extinction Profile Analysis (STEP Technology) |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Sample Volume per Cell | 0.05 mL to 2.0 mL |
| Concentration Range | 0.00015 wt% to 90 wt% |
| Viscosity Range | 0.8 mPa·s to 10⁸ mPa·s |
| Particle Size Range (Stability Mode) | 10 nm to 1000 μm |
| Particle Size Range (ISO 13318-2 Compliant Mode) | 20 nm to 100 μm |
| Density Range | up to 22 g/cm³ |
| Acceleration Range | 6×g to 2300×g |
| Optical Wavelengths | Multi-wavelength source (e.g., 870 nm, optionally 470 nm and/or 650 nm) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFuge |
| Centrifugal Acceleration | up to 1200 × g |
| Sample Capacity | 8 positions |
| Temperature Control Range | 4–60 °C (in three programmable zones) |
| Sample Volume | 0.1–2 mL |
| Particle Size Range | 0.05–1000 µm |
| Concentration Range | 1–90 vol% |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | 0.01–10 g/cm³ |
| Separation Velocity Resolution | 0.01–1000 µm/s |
| Compliance | ISO 13318-2 |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiReader X-Ray |
| Pricing | Upon Request |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader® PSA |
| Measurement Principle | Spatially Resolved Transmission Analysis (SRTA) with Multi-Wavelength Optical Detection |
| Compliance | Designed for GLP/GMP environments |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiSizer |
| Measurement Principle | Spatial-Temporal Extinction Profiling (STEP) Technology |
| Sample Capacity | 12 positions |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (Stability & Distribution) | 10 nm – 1000 μm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical Wavelengths | Multi-wavelength LED sources |
| Sample Volume per Cell | 0.05 – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Compliance | ISO 13318-2, ISO/TR 13097, FDA 21 CFR Part 11 (via SEPView software), GLP/GMP-ready audit trail |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Array Eddy Current Testing Instrument |
| Inspection Method | Automated Scanning |
| Eddy Current Signal Type | Multi-Frequency Eddy Current |
| Design Form Factor | Portable |
| Number of Channels | Customizable |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MAIERIC |
| Measurement Principle | Combined DC-biased hysteresis loop tracing + high-frequency Barkhausen noise detection |
| Signal Acquisition | Dual-channel synchronized B–H and MBN waveform capture |
| Excitation Frequency Range | 0.1–100 Hz (programmable) |
| MBN Bandwidth | 20 kHz–1 MHz (programmable bandpass filter) |
| Data Output Format | .db (binary database with timestamped MBN, B, H waveforms) |
| Interface | Wi-Fi-enabled real-time PC control |
| Compliance | Designed for ASTM E1444/E2884-compliant magnetic testing workflows |
| Software Features | Real-time x–y scalable plotting of B(H), H(t), and MBN(t) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH Hysteresis Loop & Barkhausen Noise Analyzer |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-frequency MBN detection |
| Excitation Frequency Range | 1 Hz – 1 kHz (programmable) |
| Signal Acquisition | Simultaneous B (flux density), H (magnetic field strength), and MBN (Barkhausen noise) waveforms |
| Data Output Format | .db (binary database with timestamped raw channels) |
| Real-time Display | Adjustable XY scaling for B–H loop, H(t), MBN envelope, and time-domain MBN burst trains |
| Connectivity | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 backup |
| Filtering | Programmable bandpass filter (10 kHz – 1 MHz, 3rd-order IIR) for MBN |
| Amplification | Programmable preamplifier gain (20 dB – 60 dB, 10 dB steps) |
| Compliance | Designed per IEC 60404-4 (magnetic materials — methods of measurement of DC magnetic properties) and ASTM A341/A341M (standard test method for direct-current magnetic properties of materials) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | BH-MBN-1000 |
| Measurement Principle | Dual-mode electromagnetic induction + Hall-effect field sensing + high-sensitivity MBN coil detection |
| Excitation Frequency Range | 1 Hz – 10 kHz (programmable) |
| MBN Bandpass Filter | 20 kHz – 2 MHz (adjustable center frequency & bandwidth) |
| Signal Acquisition | Simultaneous real-time sampling of B (flux density), H (magnetic field strength), and MBN voltage waveform |
| Data Output Format | SQLite (.db) with timestamped raw channels, calculated coercivity (Hc), remanence (Br), and MBN RMS/peak amplitude |
| Interface | Wi-Fi 802.11n (IEEE 802.11 compliant), USB 2.0 fallback |
| Software Platform | Windows 10/11 native application with GLP-compliant audit trail logging (user action timestamps, parameter change history, export metadata) |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | CFT-1 |
| Coercivity Range | 1–50 A/cm |
| Measurement Depth | Up to 30 mm |
| Surface Clearance | Up to 6 mm |
| Measurement Speed | ~3.5 s per reading |
| Excitation Levels | 3 adjustable intensity settings |
| Data Storage | 32 GB internal (DB & CSV export) |
| Display | 2K full-touchscreen interface |
| Compliance | Designed for field-deployable non-destructive evaluation (NDE) of ferromagnetic components |
| Interface | USB, HDMI, sensor port |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CFT-Series |
| Pricing | Upon Request |
| Excitation Levels | 3 Adjustable Steps |
| Lift-off Tolerance | Up to 6 mm |
| Measurement Speed | 3.5 s per reading |
| Penetration Depth | 30 mm |
| Coercivity Range | 1–50 A/cm |
| Display | 2K Full-Touch LCD |
| Storage Capacity | 32 GB (DB + CSV export) |
| Measurement Modes | Manual Keypad / Continuous Auto-Scan |
| Calibration | Intelligent Auto-Calibration Routine |
| Imaging | Built-in 1D/2D Mapping Visualization |
| Data Export | Standard DB & CSV formats |
| Compliance | Designed for ASTM E1444/E709-compliant magnetic particle inspection workflows and ISO 10893-1 non-destructive testing requirements |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | MBN-2000 |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Signal Bandwidth | 10 kHz – 2 MHz (programmable bandpass) |
| MBN Preamp Gain | 20–80 dB (software-adjustable) |
| Excitation Frequency Range | 1 Hz – 1 kHz |
| Excitation Voltage Amplitude | 0–20 Vpp (programmable) |
| Data Storage Format | SQLite (.db) with timestamped raw MBN, B, and H waveforms |
| Real-time Display | Dual-axis XY plot (H vs. B, MBN envelope vs. H) with scalable axes |
| Connectivity | IEEE 802.11n Wi-Fi (2.4 GHz), USB 2.0 fallback |
| Compliance | Designed per IEC 60404-6 (magnetic measurement methods), compatible with ASTM A932/A932M (standard test method for Barkhausen noise evaluation of ferromagnetic materials) |
| Brand | MAIERIC |
|---|---|
| Model | MBN-BH Grinding Burn Detector |
| Measurement Principle | Magnetostrictive Barkhausen Noise (MBN) + Quasi-Static B-H Hysteresis Loop Analysis |
| Core Components | U-Core Excitation/Detection Probe with Integrated Hall Sensor & Miniature MBN Pickup Coil |
| Signal Acquisition | Simultaneous Real-Time MBN, B(t), and H(t) Waveforms |
| Data Output | .db Binary Format with Timestamped Raw Signals |
| Connectivity | Wi-Fi Enabled PC-Based Control Interface |
| Software Features | Programmable Excitation Frequency/Amplitude, Adjustable MBN Bandpass Filter, Configurable Pre-Amplifier Gain, Dual-Axis Scalable XY Plotting (B vs. H, MBN vs. Time, H vs. Time) |
| Compliance Context | Designed for GLP-aligned magnetic property evaluation per ASTM A342/A342M (Permeability), ISO 643 (Metallographic Hardness Correlation), and internal QC protocols for aerospace & automotive component manufacturing |
| Brand | MAIERIC |
|---|---|
| Model | MTIA-A |
| Measurement Frequency Range | 0.05 Hz – 10 MHz |
| Basic Accuracy | ±0.05% |
| Impedance Range | 20 mΩ – 1 GΩ |
| Measurement Speed | Up to 10,000 samples/sec |
| Resolution | 0.05 Hz (frequency), 0.01 V (voltage) |
| Excitation Voltage Range | 0.02 V – 2 V |
| Measurement Modes | Four-Terminal (Kelvin), Multi-Channel (up to 128 channels, 16 active simultaneously) |
| Impedance Parameters | Z, R, X, L, C, D, Q, θ |
| Compensation Methods | Open-Short-Load, Open-Load, Short-Load, Load-only |
| Analysis Features | Equivalent Circuit Modeling, Time-Domain Sequence Plotting, Multi-Channel Compensation, Sweep & Multi-Channel Mapping |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | PECT-1 PULSED EDDY CURRENT |
| Design | Portable |
| Inspection Method | Pulsed Eddy Current (PEC) |
| Signal Type | Transient Electromagnetic Response |
| Measurement Integration | Encoder-based Position Tracking |
| Lift-off Tolerance | Up to 160 mm |
| Wall Thickness Range | 1–30 mm |
| Non-ferromagnetic Cladding Penetration | Up to 2 mm |
| Cladding Thickness Variation Compensation | ±50% with ≤±2% measurement deviation |
| Imaging Mode | User-configurable 2D grid mapping with real-time coordinate registration |
| Compliance | Designed for ASTM E2884-23 (Standard Guide for Pulsed Eddy Current Examination), ISO 12718:2019 (Non-destructive testing — Vocabulary — Eddy current testing), and GLP-aligned data integrity workflows |
| Brand | MAIERIC |
|---|---|
| Origin | Anhui, China |
| Model | TEST |
| Measurement Principle | Electromagnetic Induction + Hall Effect + High-Frequency Eddy Current Coupling |
| Core Functions | Simultaneous MBN Signal Acquisition, Quasi-Static BH Loop Tracing, Coercivity & Remanence Calculation |
| Connectivity | Wi-Fi (IEEE 802.11 b/g/n), USB 2.0 |
| Signal Bandwidth | MBN Channel: 50 kHz – 1.2 MHz (programmable bandpass filter), B/H Channels: DC – 10 kHz |
| Data Output Format | SQLite .db (timestamped raw MBN, B, H waveforms + calculated hysteresis parameters) |
| Software Interface | Windows-based GUI with real-time XY scaling, parameter sweep capability, and export to CSV/MAT |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | lgTIRF |
| Pricing | Upon Request |
| Measurement Principle | Light-guided TIRF (not SQUID) |
| Excitation Delivery | FC-PC fiber-coupled (2 m length) |
| Evanescent Field Depth | ~100 nm |
| Compatible Objectives | Dry, water-immersion, oil-immersion |
| Substrate Compatibility | Glass/silica coverslips, optically clear-bottom dishes |
| Excitation Wavelength Range | 190–1000 nm (UV-capable) |
| Configurable Modes | TIRF, SAFM (shallow-angle fluorescence), MSE (microspot excitation) |
| Calibration | Factory-calibrated, angle-stabilized geometry |
| Switching Speed | Instant mode switching between TIRF/SAFM/MSE/epifluorescence/transmission |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / ResoCe Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Makeway |
|---|---|
| Model | MKW-4900 |
| Origin | Shanghai, China |
| Magnet Type | Electromagnet |
| Temperature Range | 300 °C (max) |
| Measurement Principle | Thermally Stimulated Depolarization Current (TSDC) |
| Voltage Range | ±100 V to ±10 kV |
| Software Platform | aixPlorer / Resoce Analyzer |
| Interface | GPIB, Ethernet, ODBC |
| Output Format | ASCII |
| Brand | Makeway |
|---|---|
| Model | MKW-KP002 |
| Origin | Shanghai, China |
| Application Environment | Ambient, Controlled Atmosphere, or Humidity-Regulated Conditions |
| Work Function Resolution | 1–3 meV (2 mm tip), 5–10 meV (50 µm tip) |
| Tip-to-Sample Distance Control | Down to ≤400 nm |
| Digital Control Architecture | Full FPGA-based digital signal processing with ON (Off-Null) detection, Height Regulation (HR), Parallel Plate (PP) oscillation mode, Signal Averaging (SA), Work Function Averaging (WA), Quick-Change Tip (QT), Faraday Cage (FC), TTL Output Channel (OC), Data Export to Excel/Origin (DE) |
| Brand | Makeway |
|---|---|
| Origin | Shanghai, China |
| Model | MKW-KP004 |
| Probe Count | 9 integrated Kelvin probes |
| Maximum Substrate Size | 300 mm (12-inch) wafers |
| Energy Resolution | < 1 meV |
| Probe Tip Diameter | 1.4 mm (metal) |
| Angular Position Sensing Resolution | 1° |
| X-Axis Motorized Travel | > 100 mm, Positioning Accuracy: ±50 µm |
| Rotational Axis | Motorized silicon wafer stage with integrated optical encoder |
| Dead-Zone Minimization | Optimized for small wafers and wafer fragments |
| Work Function Calibration Reference | Integrated HOPG or Au reference |
| Environmental Monitoring | Onboard USB-connected temperature & humidity sensor |
| Faraday Cage | Fully integrated gold-plated steel enclosure |
| Software Control | Scriptable measurement engine supporting user-defined protocols |
| Data Output | Full-wafer, half-wafer, quarter-wafer, line-scan, and point-mode surface potential maps |
| Compliance Framework | Designed for GLP-aligned lab environments |
| Brand | MAS |
|---|---|
| Origin | USA |
| Model | ZetaFinder ZF400 |
| Zeta Potential Range | ±500 mV |
| pH Range | 0–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | ±0.1 |
| Temperature Resolution | ±0.1 °C |
| Accuracy | ±2% |
| Repeatability | ±2% |
| Particle Size Range | 5 nm – 1000 µm |
| Conductivity Range | 0–10 S/m |
| Sample Concentration | 0.1–60 vol% |
| Sample Volume | 30–230 mL |
| Measured Parameters | Particle Size Distribution, Zeta Potential, Isoelectric Point (IEP), Electroacoustic Amplitude (E5A), Conductivity, pH, Temperature, Acoustic Attenuation, Solid Content |