Physical Property Testing Instruments
Filter
Showing 2311–2340 of 4517 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TT DMA |
| Temperature Range | −190 °C to 600 °C |
| Frequency Range | 0.001 Hz to 1000 Hz |
| Fixture Configurations | Dual-cantilever, single-cantilever, 3-point bending, shear, tension, compression |
| Operating Modes | Creep, constant-force (TMA), stress–strain, stress relaxation, isothermal, step-isothermal, multi-ramp thermal profiles |
| Environmental Options | Humidity chamber (up to 85 °C / 85 % RH), liquid immersion cell, gas purge (N₂, air, Ar) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | X3305 |
| IP Rating | IP65 (standard), IP69K (optional) |
| X-ray Source Power | 20 W |
| System Length | 1.8 m |
| Compliance | GMP, NSF/ANSI 169, EHEDG Guideline Doc. 8.2 |
| Application Scope | Small-to-medium packaged food, pharmaceutical, and consumer goods |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | MFR 2100 |
| Sample Volume Requirement | ≥100 µL |
| Frequency Range | 0–100 Hz |
| Gap Adjustment Range | 0.6–30 mm |
| Gap Resolution | 0.625 mm |
| Actuation Mode | Pseudo-Random Squeezing (Patented) |
| Data Acquisition | Real-Time Fourier Transform Analysis |
| Control | Fully Automated Computer-Controlled Gap & Sample Handling |
| Brand | Kägi |
|---|---|
| Origin | Germany |
| Model | Micro IRHD |
| Instrument Type | Microindentation Hardness Tester for Elastomers |
| Standards Compliance | DIN ISO 48, ISO 48:2018, ASTM D1415-19, BS 903-A26 |
| Sample Thickness Range | 1–5 mm (recommended), up to 90 mm (with optional fixtures) |
| Resolution | 0.1 Micro IRHD |
| Dimensions (Tester) | Ø200 mm × 470 mm |
| Dimensions (Controller) | 290 mm × 260 mm × 75 mm |
| Weight | 17.5 kg |
| Control Interface | RS232 serial communication with Windows PC |
| Automation | Motorized Z-stage, programmable dual-weight actuation, auto-positioning sample stage |
| Software Platform | Native MS Windows application with real-time data acquisition, statistical analysis, hysteresis calculation, report generation (PDF/CSV), label printing, and ASCII export |
| Brand | Micro Materials |
|---|---|
| Origin | United Kingdom |
| Model | NanoTest Vantage |
| Instrument Type | Integrated Nanoindentation & Scratch Tester |
| Maximum Indentation Depth | >10 mm |
| Effective Load Range | 500 mN |
| Load Resolution | 3 nN |
| Displacement Range (XY) | 100 µm × 100 µm |
| Displacement Resolution | 0.002 nm |
| Maximum Friction Force | >250 mN |
| Indenter Types | Diamond, Cubic Boron Nitride (c-BN), Sapphire |
| Thermal Drift | <0.005 nm/s |
| Brand | Micro Materials |
|---|---|
| Origin | United Kingdom |
| Model | Xtreme |
| Instrument Type | Nanoindentation and Scratch Tester |
| Displacement Resolution | 0.002 nm |
| Indenter Types | Diamond, Boron Nitride, Sapphire |
| Thermal Drift | < 0.005 nm/s |
| Vacuum Level | 10⁻⁷ mbar |
| Temperature Range (Vacuum) | −40 °C to 1000 °C |
| Load Frame | Electromagnetic Actuation |
| Load Resolution | 3 nN |
| Repeatability Accuracy | < 0.4 µm |
| Compliance | ISO 14577, ASTM E2546 |
| Brand | Micro-field / Guangzhou Micro-field Optical Technology Co., Ltd. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Series | K-Series |
| Pricing | Available Upon Request |
| Probe Diameter | 0.8–8 mm |
| Insertion Tube Length | Standard 0.5–10 m (Customizable up to 30 m) |
| Camera Resolution | ≥1.0 MP |
| Key Features | Quick-swap probe assembly |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 1,350 (FOB) |
| Capacity Options | 1000 kg / 2000 kg / 5000 kg |
| Test Area | 1200 mm × 1200 mm (customizable) |
| Resolution | 1/10,000 full scale |
| Units | kg, N, lb |
| Compression Speed | 10 ± 3 mm/min |
| Machine Dimensions | 1200 mm × 1000 mm × 1400 mm |
| Weight | Approx. 750 kg |
| Power Supply | 220 V AC, 50 Hz |
| Load Cell | High-precision explosion-proof load cell (USA-made) |
| Drive System | Taiwan-sourced AC frequency-controlled motor |
| Actuation | Precision ball screw vertical lift mechanism |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | MIL-STD-810G Method 506.6, IEC 60529 IPX1–IPX6, GB/T 4208, GB/T 2423.38, GJB 150.8 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | –40 °C to +150 °C (standard) |
| Humidity Range | 30–98% RH (standard) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Programmable Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | SUS304 Stainless Steel or A3 Steel with Electrostatic Powder Coating |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1, GB2423.2, GB2423.22, GB2424.1 |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,200 (FOB) |
| Compliance | GB/T 16491, GB/T 1040, GB/T 2790–2792, GB/T 3923.1, GB/T 528, GB/T 17200, GB/T 16825 |
| Load Cell Accuracy | ±0.03% F.S. |
| Resolution | 1/100,000 full scale |
| Encoder | 2500 PPR AC servo motor with Panasonic drive |
| Drive System | Precision preloaded ball screw + linear guideways |
| Safety Features | Stroke limit switch, overload protection (150% transient capacity), real-time upper-limit warning |
| Environmental Compensation | Automatic temperature drift compensation |
| Software Functions | Real-time curve plotting, peak hold, break detection & auto-stop, unit conversion, data export (CSV/PDF), report generation |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP 2020 |
| Pricing | Available Upon Request |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | AutoPore V Series |
| Pore Size Range | 3 nm – 1100 µm |
| Pressure Range | 0.2 – 50 psia |
| Intrusion/Extrusion Volume Precision | < 0.1 µL |
| Compliance | ASTM D4284, D4404, D6761 |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 5390 |
| Principle | Electrical Sensing Zone (Coulter Principle) |
| Size Range | 0.4–1200 µm (20:1 to 30:1 dynamic range per orifice) |
| Concentration Range | 1–1000 ppm (v/v) |
| Sensing Rate | 1–5,000 particles/sec |
| Analysis Time | 10–100 sec (as low as 1 sec) |
| Repeatability | ±1% (n=10, same sample) |
| Reproducibility | ±1.5% (inter-instrument) |
| Electrolyte Compatibility | Aqueous, organic, or solvating organic media |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant software |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELCAT II |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Dynamic Flow Method |
| Number of Gas Inlets | 8 (Pre-treatment), 3 (Carrier), 8 (Pulse), 8 (Mixing) |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±1 °C |
| Heating Rates | 50–500 °C at 70 °C/min |
| Pressure Range | Atmospheric |
| Key Functions | TPD, TPR, TPO, TPRx, Pulse Chemisorption, Single-point BET, Breakthrough Curve Analysis |
| Gas Compatibility | He, Kr, N2, Ar, O2, H2, CO, CO2, NH3, H2O, NO, SO2, H2S, CH3OH, C2H5OH, Toluene, Benzene, and other reactive/volatile species |
| Thermal Conductivity Detector (TCD) | Quad-wire configuration with W–Re or gold-plated tungsten filaments |
| resolution | 1 μV |
| Mass Flow Controllers (MFCs) | 3–4 units |
| Sample Volume Capacity | 0–1 cm³ |
| Pulse Loop Volumes | 0.3 cm³, 1 cm³, or custom |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BELMASS II |
| Instrument Type | Chemisorption Analyzer with Integrated Online MS Detection |
| Gas Inlet Ports | Up to 16 |
| Temperature Stability | ±0.001 °C |
| Supported Techniques | TPD, TPR, TPS, Pulse Titration, BET Surface Area Analysis (via coupled gas dosing) |
| Mass Range | 1–200 amu |
| Detector | Faraday Cup / Continuous Dynode Electron Multiplier (C-SEM) |
| Minimum Detectable Concentration | <1 ppm (gas-dependent) |
| Scan Speed Options | Auto, 0.01–10 sec per amu (selectable) |
| Detection Channels | Up to 16 simultaneous mass channels |
| Sample Interface | Heated capillary transfer line (up to 300 °C), integrated dry scroll pump |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Model | BELPORE Series |
| Measurement Volume Range | 0.5–2 cm³ |
| Pressure Range | Vacuum to 414 MPa |
| Volume Measurement Accuracy | Better than 1% F.S. |
| Pressure Measurement Accuracy | Better than 0.1% F.S. |
| Maximum Data Points | 10,000 (intrusion) + 10,000 (extrusion) |
| Certified | CE, ISO 9001 |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP HP |
| Pressure Range | Up to 20 MPa (optional: 13.5 MPa) |
| Pressure Sensor Options | 1, 1.5, 2, 3.5, 13.5, or 20 MPa (±0.08% F.S.) |
| Temperature Control Range | 4.2 K – 673 K (via liquid He/N₂ cryostats, resistive furnaces, Peltier units, and air-bath thermal management) |
| Gas Inlets | 6 total (1 He for dead-volume calibration, 1 compressed air, 4 adsorptive gases) |
| Vacuum System | Optional turbomolecular pump + vacuum gauges |
| Compliance | Built-in compressibility factor (Z) and virial coefficient correction for non-ideal gas behavior |
| Sealing | Swagelok® filter-faced ferrules (0.5 µm pore size) |
| Thermal Stability | Air-bath manifold & reference chamber (15–35 °C, ±0.1 °C) |
| Software | BELSIM™ (isotherm modeling, PCT analysis), optional BELDyna™ (kinetic modeling: concentration vs. time, effective diffusivity, mass transfer coefficients) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELSORP MAX G |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Volumetric Gas Adsorption (Dynamic & Static Mode) |
| Number of Analysis Stations | 3 or 6 |
| Operating Temperature Range | 10–35 °C |
| Storage Temperature Range | 0–50 °C |
| Temperature Control Accuracy | ±1 °C |
| Vacuum System | Dual-stage rotary vane pump, ultimate vacuum ≤1 × 10⁻³ mmHg (≤0.13 Pa) |
| Pressure Sensors | 1 Torr, 10 Torr, and 1000 Torr high-precision capacitance manometers |
| Minimum Detectable Pressure Change | <1 × 10⁻⁵ Pa |
| Free Space Calibration | AFSM™ (Automatic Free Space Measurement) patented technology |
| Isotherm Range | P/P₀ = 1 × 10⁻⁷ to 0.997 at 77 K (N₂) and 87 K (Ar) |
| Brand | Microtrac |
|---|---|
| Origin | Japan |
| Model | BELSORP MINI X |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption (Combined with Dynamic Pre-evacuation) |
| Analysis Stations | 4 |
| Surface Area Range | ≥0.01 m²/g (no upper limit) |
| Pore Size Range | 0.35–500 nm |
| Pressure Range | 0–133.3 kPa |
| Measurement Theory | Static Volumetric Method + Advanced Free Space Monitoring (AFSM™) |
| Compliance Options | FDA 21 CFR Part 11, IQ/OQ Documentation Package Available |
| Brand | Microtrac MRB |
|---|---|
| Origin | USA |
| Model | AutoChem II 2920 Series |
| Temperature Range | Ambient to 1100 °C (furnace), –100 °C (CryoCooker), up to 150 °C (gas lines) |
| Detection | High-Linearity TCD with corrosion-resistant filament |
| Gas Control | 12 independent gas inlets, 4 precision mass flow controllers |
| Analytical Modes | Pulse chemisorption, TPR, TPD, TPO, TPRx, vapor-phase adsorption |
| Vapor Capability | Integrated steam generator for pyridine, water, benzene, etc. |
| Cooling | KwikCool rapid furnace cooling system |
| Compliance | Designed for GLP/GMP environments |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC FLEX |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Reproducibility | ≤1% RSD |
| Temperature Control Range | 10–35 °C |
| Temperature Stability | ±0.1 °C (with optional Peltier module) |
| Detection Method | Dynamic Light Backscattering (180° geometry) with full-range Mie theory-based data inversion |
| Sample Volume | as low as 2 µL |
| Sample Concentration Limit | up to 40 vol.% (non-dilutive measurement) |
| Zeta Potential Range | –3000 mV to +3000 mV (when coupled with STABINO ZETA) |
| Molecular Weight Estimation | via hydrodynamic diameter and Debye plot correlation |
| Optical Architecture | Fixed-focal-length fiber-optic probe with laser amplification detection |
| Data Processing Algorithm | Frequency Power Spectrum (FPS), not conventional Photon Correlation Spectroscopy (PCS) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | NANOTRAC WAVE II |
| Zeta Potential Range | ±200 mV |
| Temperature Operating Range | 0–90 °C (programmable ramp) |
| pH Resolution | 0.1 |
| Temperature Accuracy | ±0.1 °C |
| Particle Size Range | 0.3 nm – 10 µm |
| Concentration Range | 100 ppb – 40 % w/v |
| Detection Angle | 180° (backscatter) |
| Repeatability | ≤1% |
| Theoretical Basis | Full-range Mie theory with non-spherical particle correction factor |
| Compliance | ISO 13321, ISO 13099-2:2012, ISO 22412:2008 |
| Software Compliance | FDA 21 CFR Part 11 (electronic signatures, audit trail, user access control) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500 Series |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Laser Diffraction) | 0.01–2,800 µm |
| Image Analysis Range | 0.75–2,000 µm |
| Repeatability | <1% |
| Measurement Time (Laser Diffraction) | 10–30 s |
| Measurement Time (Dynamic Image Analysis) | ~60 s |
| Light Source | Patented Triple-Solid-State Laser (Laser Diffraction) / High-Intensity Stroboscopic LED (Image Analysis) |
| Detection Angle Range | 0.02°–163° |
| Detector Array | 151 logarithmically spaced silicon photodiodes |
| Image Sensor | 5 MP, 2456 × 2058 resolution, 15 fps (optional high-speed camera available) |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, data integrity controls) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500SI |
| Measurement Principle | Laser Diffraction & Dynamic Image Analysis |
| Size Range (Laser Diffraction) | 0.01–2800 µm |
| Size Range (Dynamic Imaging) | 0.75–2000 µm |
| Repeatability | ±0.1% |
| Light Source | Triple Solid-State Red Lasers (635 nm) + High-Intensity Stroboscopic LED |
| Detector Array | 151 Logarithmically Spaced Silicon Photodiodes, Acceptance Angle: 0.02°–163° |
| Imaging Sensor | 5 MP CMOS, Resolution: 2456 × 2058 |
| Analysis Time (LD) | 10–999 s |
| Analysis Time (Imaging) | 60 s per field |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Data Integrity Controls |