Physical Property Testing Instruments
Filter
Showing 2401–2430 of 12279 results
| Brand | Fangyuan Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DR89S |
| Measurement Principle | Pulse-Echo Ultrasonic (Single-Crystal Transducer) |
| Thickness Range | 0.15–300 mm |
| Display Resolution | 0.001 mm |
| Measurement Accuracy | ±(0.01 + 0.3% H) mm |
| Probe Frequency | 5 MHz (standard single-crystal contact transducer) |
| Material Compatibility | Carbon steel, stainless steel, aluminum, copper, and other homogeneous metallic substrates |
| Coating Compensation | Yes — supports paint, enamel, plastic, and epoxy layer compensation without surface preparation |
| Operating Temperature | 0–50 °C |
| Data Storage | Internal memory for ≥1,000 readings |
| Output Interface | USB 2.0 for PC data transfer |
| Compliance | Meets ISO 2400:2019 (Ultrasonic thickness measurement — Calibration and verification procedures), ASTM E797-23 (Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method) |
| Brand | Fangyuan Instruments |
|---|---|
| Origin | Guangdong, China |
| Model | DR9000 |
| Measurement Principles | Magnetic Induction (for Fe substrates) & Eddy Current (for non-Fe substrates) |
| Measurement Range | 0–1250 µm (Fe), 0–1250 µm (non-Fe) |
| Resolution | 0.1 µm (≤100 µm), 1 µm (>100 µm) |
| Accuracy | ±(1–3)% of reading or ±2 µm (whichever is greater) |
| Substrate Compatibility | Ferrous (steel, iron) and non-ferrous (aluminum, stainless steel, copper, zinc, brass) |
| Display | 2.4" TFT LCD with backlight |
| Data Storage | Up to 10,000 readings (grouped by batch ID) |
| Interface | USB-C for data export |
| Compliance | ISO 2178, ISO 2360, ASTM B499, ASTM D7091, DIN EN ISO 1461 |
| Brand | Fangyuan Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GB7706 |
| Quotation | Upon Request |
| Specimen Area | 60 × 210 mm |
| Rubbing Speed | 4 adjustable speeds (21 / 42 / 85 / 106 cycles per minute) |
| Applied Load | 4.5 lb (2.04 kg, 20 N) |
| Stroke Length | 60 mm |
| Cycle Count Range | 0–999,999 (auto-stop) |
| Rubbing Contact Area | 50 × 100 mm |
| Power Consumption | 40 W |
| Dimensions (W×D×H) | 300 × 325 × 300 mm |
| Net Weight | 20 kg |
| Input Voltage | AC 220 V, 1 A |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FM-PR-PDS |
| Instrument Type | Optical Particle Counter |
| Detection Threshold | ≥0.1 µm (PSL-equivalent, NIST-traceable) |
| Throughput | Up to 400 Wafers per Hour (WPH) |
| Dual-Side Inspection | Simultaneous front & back surface imaging |
| Compliance | ISO 14644-9 (Cleanroom classification reporting), Supports SCP (Surface Contamination Particle) grading in PDF and GUI |
| Measurement Mode | Static Field-of-View Imaging (no stage motion during acquisition) |
| Application Scope | DUV/EUV photomask pellicles, reticles, semiconductor wafers, advanced packaging substrates, and precision optical substrates |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-PS-PFS-V02 |
| Measurement Principle | Dark-field Mie scattering |
| Measurement Range | 0.5–150 µm |
| Repeatability | ≥90% |
| Measurement Interval | ≤10 s per scan |
| Field of View (FOV) | Ø25 mm (on 50 mm replaceable substrate) |
| Environmental Operation | Ambient pressure and vacuum-compatible |
| Compliance | ISO 14644-9, ISO 14644-17 |
| Output Formats | KLARF, Excel, PDF (ISO-compliant qualification reports) |
| Software | Integrated real-time analysis with annotated imaging and 3D signal profiling |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-PS-PFS-V02 |
| Instrument Type | Optical Particle Fallout Monitor |
| Compliance | ISO 14644-9, ISO 14644-17 |
| Detection Threshold | ≥0.5 µm (NIST-traceable) |
| Sampling Interval | Adjustable down to 10 s |
| Substrate | 2-inch silicon wafer |
| Measurement Output | Deposition Rate (DPRL), particle count, size distribution, spatial density, time-resolved deposition profile |
| Brand | Fastmicro |
|---|---|
| Country of Origin | Netherlands |
| Instrument Type | Optical Particle Counter |
| Model | FM-PS-SAS-V01 |
| Sampling Principle | Tape-based Indirect Extraction |
| Minimum Detectable Particle Size | 0.5 µm |
| Field of View | 225 mm² per scan |
| Scan Time | <5 seconds |
| Sample Carriers | Certified PMC Adhesive Cards & 2-inch Wafer Kit |
| Compliance | ISO 14644-1, ISO 14644-7, USP <788>, ASTM E2457 |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-W-PDS |
| Instrument Type | Optical Particle Counter |
| Field of View (FOV) | 4–12 inch diameter |
| Detection Principle | Dark-Field Microscopy with High-Resolution Digital Imaging |
| Minimum Detectable Particle Size | ≥0.1 µm |
| Configuration | Manual or Automated Wafer Handling |
| Dual-Side Scanning | Optional |
| Measurement Mode | Static FOV Imaging (No Sample Translation During Acquisition) |
| Compliance | Designed for ISO 14644 Cleanroom Environments, Compatible with SEMI Standards for Wafer Inspection |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Instrument Type | Adiabatic Reaction Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Model | ARSST |
| Compliance Basis | DIERS-validated two-phase flow methodology (OSHA-recognized “Exemplary Engineering Practice”) |
| Sample Volume | 5–10 g in 10 mL lightweight quartz test cell |
| Pressure Vessel Capacity | 350 mL rated pressure vessel |
| Operating Modes | Scanning & Isothermal |
| Optional Accessories | High-pressure test cells, Flow-Regime Evaluation Detector (FRED™) |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VSP2 |
| Price Range | USD 135,000 – 270,000 (based on configuration and service package) |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Sample Volume | 116 mL |
| Cell Wall Thickness | 0.01 in (0.254 mm) |
| Thermal Inertia (φ) | ≤ 1.05 |
| Maximum Pressure Rating | >2000 psi (13.8 MPa) |
| Heating | Dual-zone (internal sample heater + external guard heater) |
| Pressure Equalization | Active dynamic compensation |
| Stirring | Optional magnetic stirring (standard & high-torque super-magnetic variants) |
| Cell Materials | 304 SS, 316 SS, Hastelloy C, Titanium, Quartz |
| Test Modes | Closed, Venting (small-scale relief), Isothermal, Dynamic Ramp, Quench Simulation |
| Brand | FemtoTools |
|---|---|
| Origin | Switzerland |
| Model | FT-G Series Nanotweezers (FT-G30, FT-G60, FT-G100) |
| Compatible Systems | FT-GS1000 Micro-Nano Assembler, FT-GS5000 Nano Assembly System |
| Controller | FT-GC01 Nanotweezer Controller |
| Operating Environments | Ambient air, liquid, and high vacuum (SEM-compatible) |
| Force Feedback | Integrated capacitive force sensor (FT-G30 & FT-G100) |
| Displacement Resolution | <1 nm |
| Force Resolution | <100 pN |
| Brand | SHNTI (Distributor) |
|---|---|
| Origin | Switzerland |
| Model Series | FT-RS / FT-FS / FT-S / FT-G / FT-UMS1000 |
| Instrument Type | Nanoindentation and Scratch Tester |
| Maximum Indentation Depth | 1 µm |
| Effective Load Range | 5 nN – 10 mN |
| Load Resolution | 1 nN |
| Displacement Range | ±100 µm |
| Displacement Resolution | 5 nm |
| Maximum Friction Force | 1 mN |
| Indenter Tip Types | Berkovich, Cube-Corner, Flat Punch, Spherical (customizable) |
| Thermal Drift | <0.1 nm/s (at 25 °C, stabilized environment) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FERITSCOPE FMP30 |
| Measurement Principle | Magnetic Induction (Ferrite-Specific Permeability Detection) |
| Display | Backlit LCD, 128 × 64 pixels |
| Probe Interface | Interchangeable modular probe connector |
| Calibration | Single-point calibration across full measurement range |
| Units | % Fe (ferrite number equivalent) and vol.% Fe |
| Compliance | Designed per ISO 8249:2017, ASTM A802, EN 17068 |
| Operating Temperature | 0 °C to 50 °C |
| IP Rating | IP65 (dust- and water-resistant) |
| Power Supply | Rechargeable Li-ion battery (≥10 h continuous operation) |
| Data Output | USB 2.0, optional Bluetooth 4.2 module |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | 45D |
| Chamber Construction | Stainless Steel Enclosure with Polycarbonate Viewing Window |
| Test Angle | Fixed 45° Specimen Mounting |
| Applicable Standards | ASTM D3823, ISO 6927 (adapted), UL 94 HB/VTM-0 pre-screening context, KSL 2017 (Korean Standard for Surface Burning Characteristics) |
| Burner Options | Air-Mix Burner & Micro/Meker Burner |
| Flame Impingement Control | Adjustable Pressure Regulators for Both Burners |
| Timing System | Dual Independent Digital Timers (Afterflame Time & Afterglow Time) |
| Specimen Thickness Limit | ≤5 mm |
| Sample Types | Rigid & Semi-Rigid Flat Panels (Wood, Metal, Plastic Laminates, Paperboard, Thin Composites) |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | HCF-NEK606 |
| Chamber Dimensions (W×D×H) | 1220 × 1045 × 1100 mm |
| External Dimensions (W×D×H) | 1300 × 1125 × 950 mm |
| Frame Material | 50×50×t3 mm Stainless Steel 304 |
| Burner Tube ID | Ø36 mm, SS304 |
| Venturi Mixer | Air/Propane Premixing |
| Air MFC | 77.7 ± 4.8 SLPM (180 L/min) |
| Propane MFC | 15 SLPM (13.5 ± 0.5 L/min) |
| Temperature Sensors | K-type (Ø8.0 mm) & R-type (Ø8.0 mm) Thermocouples |
| Data Acquisition | PC-connected DAQ with Bluetooth antenna pair |
| Control Rack Dimensions | 730 × 650 × 1600 mm, Aluminum Alloy |
| Safety System | Automated Ignition, Interlocked Door, Flame-Out Detection |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | IEC 60754-1&2 |
| Compliance | IEC 60754-1 Ed. 2.0 b:1994, IEC 60754-2 Ed. 1.0 b:1991, GB/T 17650 |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SB 2005 |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Wall Finish | Enamel-coated steel |
| Radiation Source | Optional ISO 5659-2 compliant conical heater (0–50 kW/m²) |
| Photodetector | S4 spectral response photomultiplier tube (dark current <10⁻⁹ A) with silicon photodiode backup |
| Temperature Monitoring | Digital display with calibrated thermocouple |
| Data Acquisition | Integrated software compliant with ISO 5659-2 reporting requirements |
| Gas Sampling | Dedicated port for detector tubes (e.g., CO, HCl, HCN) |
| Calibration | NIST-traceable radiometric calibration certificate available for heat flux meter |
| Brand | FESTEC |
|---|---|
| Origin | South Korea |
| Model | SBI |
| Compliance | EN 13823, GB/T 20284 |
| Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Heat Flux | 31 kW Propane Corner Burner (250 mm × 250 mm × 80 mm) |
| Test Chamber | 3 m × 3 m × 2.4 m (L × W × H) |
| Sampling Duct | Integrated multi-sensor zone for O₂, CO, CO₂, temperature, smoke obscuration (via light extinction), and volumetric flow |
| Data Acquisition | Analog inputs for thermocouples (K-type), differential pressure sensors, gas analyzers |
| Gas Analysis System | Siemens OXYMAT 61 (paramagnetic O₂, 0–25% vol, ±1% FS/week drift, <3 s response) + U23 NDIR (CO: 0–1%, CO₂: 0–10%, ±1% FS/week, <3 s response) |
| Smoke Measurement | Laser-based optical density (OD) at 532 nm, calibrated per ISO 5659-2 |
| Flame Spread Assessment | Lateral Flame Spread (LFS) time to 1.5 m × 1.0 m specimen edge |
| Key Outputs | FIGRA (Fire Growth Rate Index), THR (Total Heat Release), SMOGRA (Smoke Growth Rate Index), TSP (Total Smoke Production), LFS, Droplet Formation Observation |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TIT |
| Price | Upon Request |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FFH |
| Pricing | Available Upon Request |
| Application Field | Transportation Vehicles |
| Compliance Standards | GB 32086–2015, ISO 6941:2003, EN 407, EU Directive 95/28/EC, Volkswagen PV 3357 |
| Power Supply | AC 220 V, 2 A |
| Fuel Gas | Industrial Propane |
| Dimensions (L×D×H) | 340 × 240 × 760 mm |
| Weight | 26 kg |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,100 (approx.) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FID-100W |
| Pricing | Available Upon Request |
| Brand | KLA |
|---|---|
| Origin | USA |
| Manufacturer | Filmetrics (a KLA company) |
| Type | Benchtop Spectroscopic Reflectometry System |
| Model | F3-sX |
| Wavelength Options | 980 nm / 1310 nm / 1550 nm |
| Thickness Range | 15 nm – 3 mm (depending on configuration and film type) |
| Spot Size | 10 µm |
| Material Library | >130 preloaded optical constants |
| Software | FILMeasure 8 (local acquisition & analysis), FILMeasure Standalone (remote data processing) |
| Compliance | Designed for semiconductor fab, R&D, and QC environments supporting GLP/GMP traceability workflows |
| Brand | KLA |
|---|---|
| Origin | USA |
| Model | Filmetrics F50 |
| Measurement Principle | Broadband Spectral Reflectometry |
| Maximum Sample Diameter | 450 mm |
| Stage Type | Motorized R-Theta Platform |
| Scan Patterns | Polar, Rectangular, Linear, and User-Defined |
| Wavelength Options | UV–NIR (model-dependent, e.g., F50-UV: 190–1100 nm |
| F50-NIR | 900–1700 nm) |
| Measurement Speed | Up to 2 points per second |
| Predefined Scan Templates | >30 built-in |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, supports audit-ready data logging per FDA 21 CFR Part 11 requirements when integrated with validated software configuration |
| Brand | Lightigo |
|---|---|
| Origin | Czech Republic |
| Model | FireFly |
| Measurement Principle | Laser-Induced Breakdown Spectroscopy (LIBS) |
| Detection Range | Li to U (nearly all elements in the periodic table) |
| Detection Limit | 1–100 ppm (matrix-dependent) |
| Spatial Resolution | 10–150 µm |
| Imaging Mode | 2D surface mapping & depth-resolved (line-scan or layer-by-layer ablation) |
| Max Scan Area | 100 mm × 100 mm |
| Ablation Rate | Up to 100 Hz |
| Sample Type | Solid materials only (conductive and non-conductive, no vacuum required) |
| Operating Environment | Ambient air or controlled atmosphere (N₂, Ar) |
| Compliance | CE-marked |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HRR-1-X |
| Pricing | Available Upon Request |
| Construction | Full Stainless Steel Enclosure |
| Radiant Heat Flux | 50 kW/m² |
| Ignition Source | 10 kV Electric Spark |
| Specimen Orientation | Horizontal |
| Exhaust Flow Rate | 0.024 m³/s |
| Compliance | JG 158–2004 Appendix H (China Building Industry Standard) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | CMS2/STEP |
| Measurement Principle | Coulometric (Anodic Dissolution) per DIN EN ISO 2177 & ASTM B764-94 |
| Application Scope | Single/Multi-layer Metallic Coatings on Conductive or Non-conductive Substrates (e.g., Fe, Cu, ABS, PCB) |
| Thickness Range | 0.05–50 µm |
| Electrolytic Rate Selection | 0.1–10 µm/min |
| Measured Area | 0.6–3.2 mm² (via interchangeable O-rings) |
| STEP Function | Simultaneous Thickness & Potential Difference Measurement (Ni multilayer systems) |
| Display | High-resolution color LCD |
| Software Features | Graphical voltage curve display, statistical analysis, multi-language UI, configurable units |
| Compliance | DIN EN ISO 2177, ASTM B764-94, DIN 50022 |
| Accessories | V18 semi-automated stand with spherical support & rotating sample plate, 3-position electrolyte bottle holder (100 mL each) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | MP10E |
| Measurement Principle | Electromagnetic Induction (DIN EN ISO 2178, ASTM B499) |
| Display | 60 × 30 mm LCD, dual-line alphanumeric (16 characters per line) |
| Probe Interface | Plug-in connector supporting up to 30 probe types (E- and VxE-series, e.g., EGAB1.3) |
| Auto-Probe Recognition | Yes |
| Data Storage | None |
| Connectivity | None |
| Power Supply | Replaceable or rechargeable batteries |
| Compliance | DIN EN ISO 2178, ASTM B499 |
| Included Accessories | Protective cap, carrying case, batteries, operating manual |
| Excluded | Probes, calibration standards |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | FERITSCOPE MP30E-S |
| Measurement Principle | Magnetic Induction (DIN EN ISO 2178) |
| Measurement Range | 0.1–80 % Fe or 0.1–110 FN |
| Display | Dual-line, 16-character LCD |
| Data Capacity | 100 programs / 1,000 data blocks / up to 10,000 measurements |
| Probe Interface | Auto-identifying plug-in connector |
| Communication | Bidirectional RS232 |
| Power Supply | 9 V alkaline or rechargeable battery, or AC adapter |
| Dimensions | 160 × 80 × 30 mm |
| Weight | 230 g (without battery) |
| Compliance | ANSI/AWS A4.2-91, DIN 32514, IIW Traceable Calibration Standards |
| Included Accessories | Protective cover, carrying case, battery, operator manual |
| Optional Probes | EGAB1.3-Fe (coaxial), EGABI1.3-Fe (internal surface/contour), EGABW1.3-Fe (90° angled) |
| Calibration Kits | Four certified WRC-92 traceable standard sets (0.3/10, 1.5/30, 10/80 %Fe |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fischerscope PMP10 |
| Pricing | Available Upon Request |
| Measurement Principle | Phase-Sensitive Eddy Current Method |
| Compliance | DIN EN ISO 21968 |
| Standard Probe Frequencies | 60 kHz, 240 kHz, 1.25 MHz |
| Software | FISCHER DataCenter (PC-based, supports data transfer, statistical analysis, graphical evaluation, and report generation) |
| Probe Options | ESD20Cu (for planar PCB copper), ESL080 (for through-hole copper plating), ESD20ZN/ESD2.4/ESD20NI (for Zn/Ni on steel) |