| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ E |
| Instrument Type | Digital PCR System |
| Sample Throughput | 48-well |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL per reaction |
| Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated, walk-away operation |
| Run Time for 48 Samples | 2.5 hours |
| Chip Format | Single disposable cartridge accommodating up to 48 samples |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX700™ HT |
| Instrument Type | Digital PCR System |
| Sample Throughput | 384-well format |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL |
| Effective Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated workflow (droplet generation, thermal cycling, and fluorescence reading) |
| Max. Chip Capacity per Run | 2 microfluidic chips |
| Time to Result | ≤2.5 hours for 96 samples |
| Time to Result | ≤8 hours for 384 samples |
| On-demand Loading | Yes, with independent thermal control per 16-well chip segment |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ S |
| Instrument Type | Digital PCR System |
| Sample Throughput | 192-well format |
| Detection Channels | 7-color simultaneous detection |
| Sample Input Volume | 5 µL |
| Effective Droplet Partitions per Sample | ≥17,000 |
| Automation Level | Fully automated end-to-end workflow |
| Chip Format | 16-well disposable cartridge (scalable to 192 samples per run) |
| Run Time for 192 Samples | 8 hours |
| Run Time for 96 Samples | 5 hours |
| Thermal Cycling | Independent programmable thermal cycling per well |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 384 Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Inter-well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 1–24°C across 12 columns |
| Gradient Accuracy (last column) | ±0.2°C |
| Operating Temperature Range | 0–100°C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96 Deep Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Ramp Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Gradient Uniformity (Within Column) | ±0.4°C within 10 s |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| PCR Licensing | Yes |
| Onboard Memory | >1,000 protocols |
| USB Ports | 4 × Type-A, 1 × Type-B |
| Display | LCD |
| Heating Technology | Instant-On Peltier |
| Thermal Block Design | Patented honeycomb architecture |
| Programmable Interface | Text-based and semi-graphical editing |
| Heat Lid | Adjustable pressure, auto-lift compatible |
| Safety | Password-protected protocol folders |
| PC Connectivity | Windows XP or later via C1000 Touch controller (up to 3 S1000 units per C1000) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96-Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Column Uniformity | ±0.4°C within 10 sec per column at target temperature |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ Dual 48 Well |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Throughput | 2 × 48 wells (0.2 mL tubes or plates) |
| Max Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Gradient Range | 30–100 °C, Span 1–24 °C |
| Temperature Range | 0–100 °C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL) |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.5 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Gradient Range | 1–25 °C |
| Temperature Range | 4–100 °C |
| Gradient Temperature Range | 30–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color LCD touchscreen |
| Cooling Method | Peltier-based |
| Heating Method | Semiconductor-based |
| Warranty | 2 years |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100™ |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL plates or tubes) |
| Max Heating/Cooling Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Uniformity | ±0.4 °C (at 90 °C) |
| Gradient Range | 30–100 °C |
| Gradient Span | 1–25 °C |
| Operating Temperature Range | 4–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color touchscreen |
| Interface | 1 × USB port |
| Brand | BIOER |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | FQD-16B |
| Sample Throughput | 16 wells |
| Maximum Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.1 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96 × 0.2 mL (compatible with single tubes, 8-tube strips, and 96-well plates) |
| Heating Rate | 6.5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Range | 4–105 °C (0.1 °C increment) |
| Fluorophore Channels | 6-channel detection (FAM/SYBR Green I, VIC/HEX/TET/JOE/TAMRA/Cy3 NED, ROX/Texas Red, Cy5, Cy5.5) |
| Dynamic Range | 1–10¹⁰ copies/L |
| Reaction Volume | 10–100 µL |
| Thermal Control Mode | Block control & simulated tube control |
| Heat Lid Temperature | 30–110 °C (default 105 °C) |
| Power Input | 100–240 V, 50/60 Hz, 1000 VA |
| Interface | USB, Bluetooth |
| Dimensions | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Safety Certifications | CE, RoHS 2 compliant |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 6.5°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Detection Channels | 6 |
| Excitation Source | Arrayed Planar LED Light Source |
| Optical Detection | Top-reading, calibration-free, bundled high-end imported optical fiber bundle |
| Thermal Control Architecture | 6-zone independent Peltier-based temperature control |
| Input Power | AC 100–240 V, 50/60 Hz, 1000 W |
| Dimensions (L×W×H) | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Compatible Consumables | 0.2 mL 96-well plates, 0.2 mL single tubes, 0.2 mL 8-tube strips (transparent, white, frosted) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | FQD-A1600 |
| Instrument Type | Real-Time Quantitative PCR System with Integrated Sample-to-Answer Automation |
| Sample Throughput | 16 samples per run |
| Maximum Heating Rate | ≥10 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Inter-well Temperature Uniformity | ≤±0.3 °C |
| Dimensions (L×W×H) | 1850 × 730 × 1530 mm |
| Power Supply | AC 220 V, 50 Hz, 2800 VA |
| Sample Input Format | Compatible with standard cryovials, centrifuge tubes, and clinical collection tubes (e.g., 1.5–2.0 mL) |
| Sample Types | Whole blood, nasopharyngeal/oropharyngeal swabs, urine, animal/plant tissues for DNA/RNA extraction |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TC-96/G/H(b)B1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥5.5 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | Up to 30 °C across block |
| Thermal Lid Temperature & Pressure | Adjustable |
| Control Interface | USB-based multi-unit networking (up to 30 units per PC) |
| Data Storage | Internal memory + USB flash drive support |
| Safety Features | Power-loss recovery, file encryption, Ferrotec Peltier modules |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GeneExplorer |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate |
| Maximum Heating Rate | 6°C/sec |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Gradient Function | 12-column linear gradient (1–30°C) |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Sample Capacity | 96 × 0.2 mL tubes |
| Temperature Range | 4–105°C (0.1°C resolution) |
| Max Heating Rate | 6°C/s |
| Max Cooling Rate | 5.5°C/s |
| Temperature Uniformity | ≤ ±0.2°C |
| Temperature Accuracy | ≤ ±0.1°C (measured 30 s after reaching 55°C, 72°C, or 95°C) |
| Heat Lid Temperature | 30–110°C |
| Gradient Range | 1–30°C |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temperature Increment/Decrement | 0.1–9.9°C |
| Program Storage | Unlimited (2000 onboard + USB/LAN/WiFi expansion) |
| Connectivity | USB, LAN, Wi-Fi |
| Power Input | 100–240 VAC, 50–60 Hz, 600 W |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Net Weight | 10.5 kg |
| Heat Lid Actuation | Single-step mechanical lock |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Max. Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.15°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Display | 10.4″ TFT-LCD capacitive touch screen |
| Cooling Technology | Custom Ferrotec thermoelectric modules |
| Optional Block Surface | Gold-plated (Au) thermal block with TAS (Thermal Alignment System) |
| Connectivity | USB 2.0, RJ45 LAN, Bluetooth 4.0 (with PC wireless control adapter) |
| Temperature Range | 4–105°C |
| Gradient Function | 6 independent zones, adjustable gradient span 0.1–5.0°C per zone |
| Max. Cycle Number | 99 cycles with nested 2-level programming (suitable for nested PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (enables Long PCR protocols) |
| Temp Increment/Decrement | 0–9.9°C (supports Touchdown PCR) |
| Power Input | AC 100–240 V, 50/60 Hz, 800 W |
| Dimensions (L×W×H) | 457 × 316 × 309 mm |
| Net Weight | 14 kg |
| Compatible Consumables | 0.2 mL 96-well PCR plates (full-skirt, half-skirt, unskirted), 0.2 mL single tubes, 0.2 mL 8-tube strips |
| On-board Memory | ≥1,000 protocols |
| Data Export | USB flash drive support |
| Power Failure Recovery | Auto-resume function with full protocol state retention |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | B-48DA |
| Instrument Type | Dual-Block Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48-well (0.2 mL tubes or 8-tube strips) |
| Heating Rate | >4 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Block Uniformity | ≤ ±0.2 °C across wells |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with 2-level nesting |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Control Modes | Block mode and simulated tube mode |
| Interface | RS232, USB, LAN, Bluetooth |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions | 457 × 316 × 309 mm (L×W×H) |
| Safety & Compliance | Supports power-fail recovery, intelligent hot lid control, TAS thermal uniformity technology |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)C |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Max Heating Rate | ≥4 °C/sec |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.3 °C |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | 0.1–9.9 °C per step (Touchdown PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (Long PCR support) |
| Control Modes | Block mode and simulated tube mode |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Net Weight | 8 kg |
| Interface | USB port |
| Data Protection | Power-fail resume function |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C |
| Temperature Range | 4–105 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | Yes |
| Touchdown PCR Support | 0.1–9.9 °C increment/decrement |
| Long PCR Support | Time increment/decrement up to 9 min 59 sec |
| Display | 6.5-inch color LCD touchscreen |
| Connectivity | USB port + Ethernet (LAN) |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Weight | 10 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Sample Capacity | 96-well plate / 12×8 strip tubes / 96×0.2 mL single tubes (bottom-transparent) |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.1°C |
| Fluorescence Channels | 6 (FAM/SYBR Green I |
| Dynamic Range | 1–10¹⁰ copies |
| Excitation Source | Long-life LED |
| Detection Mode | Bottom-scanning optical system |
| Thermal Block Control Modes | Block mode & Simulated Tube mode |
| Gradient Range | 1–36°C |
| Thermal Lid Temp Range | 30–110°C (auto-adjusting) |
| Power Input | 100–240 VAC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Certifications | CE, RoHS 2, MEC, MET, PICC Product Liability Insurance, China NMPA Registration No. 20153400273 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | Long-Life LED |
| Detection Mode | Bottom-Reading Optical System (Patented) |
| Thermal Control | Multi-Point PID with Peltier-based Semiconductor Modules (Ferrotec Custom) |
| Power Input | AC 100–240 V, 50/60 Hz, 650 W |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Interfaces | RS232, USB, Bluetooth |
| OS Compatibility | Windows 7 / 8.1 / 10 |
| Brand | bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene K Plus |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 48 × 0.2 mL (compatible with individual tubes and 8-tube strips) |
| Reaction Volume | 5–100 µL |
| Detection Channels | 4 |
| Excitation Sources | High-intensity LEDs (FAM/SYBR Green I |
| Block Temperature Range | 4–105 °C (0.1 °C resolution) |
| Max Heating Rate | 5 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Inter-well Uniformity | ≤ ±0.1 °C |
| Heat Lid Temperature Range | 30–110 °C (default 105 °C, auto-lift mechanism) |
| Independent Three-Zone Thermal Control | Adjustable gradient range 0.1–6 °C per zone |
| Operating System Compatibility | Windows XP / 7 / 8 / 10 |
| Interface Options | USB, RS232, Bluetooth |
| Power Input | 100–240 V AC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Weight | 28 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-48A |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well |
| Maximum Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | High-Intensity LED |
| Detection Method | Bottom-Optical Fluorescence Detection |
| Thermal Control Architecture | Triple-Zone Independent Peltier Control with Dual-Side Ferrotec Modules |
| Thermal Lid | Motorized Auto-Lift Lid with SOAK Function |
| Compatible Consumables | 0.2 mL Single Tubes (Flat/Capless & Dome/Capped), 0.2 mL 8-Tube Strips (Flat/Capless & Dome/Capped) |
| Interfaces | RS232, USB 2.0, Bluetooth 4.0 |
| Operating System Support | Windows 7/8.1/10 (64-bit) |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene Mini |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 16 × 0.2 mL tubes (flat, optically transparent caps) or 8 × 0.2 mL tubes (flat, optically transparent caps) |
| Reaction Volume | 10–100 μL |
| Dynamic Range | 1–10¹⁰ copies |
| Temperature Range | 0–100 °C (0.1 °C increment) |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Max Heating/Cooling Rate | 5 °C/s |
| Thermal Lid Temperature | 30–110 °C (adjustable, default 105 °C) |
| Fluorophore Channels | F1: FAM, SYBR Green I |
| F2 | VIC, HEX, TET, JOE, TAMRA, CY3 |
| F3 | ROX, Texas Red |
| F4 | CY5, Quasar-670 |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 220 × 240 mm |
| Net Weight | 6.5 kg |
| Safety Features | Short-circuit/open-circuit detection for module/thermal lid/heat sink temperature sensors |
| Interface | USB |
| Preheat Time | None required |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-16A (Mini) |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 16-well (single tubes or 8-tube strips) |
| Max Heating Rate | 5.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 |
| Detection Sensitivity | 1 copy |
| Compatible Consumables | 0.2 mL transparent/white/frosted PCR tubes and 8-tube strips |
| Optical Design | Top-scanning fluorescence detection with optimized light path to minimize stray light |
| Thermal Module | Custom Peltier-based system |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 240 × 220 mm |
| Net Weight | 6.5 kg |
| Interface | RS232 |
| Operating System | Windows 7 / 8.1 / 10 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | LineGene Mini S |
| Sample Capacity | 16 × 0.2 mL tubes or 2 × 8-tube strips (0.2 mL) |
| Power Input | 100–240 V, 50/60 Hz |
| Communication Interfaces | Ethernet port (for PC connectivity), Bluetooth 4.2 |
| Dimensions (L×W×H) | 240 mm × 180 mm × 160 mm |
| Net Weight | 4.0 kg |
| Regulatory Compliance | CE-IVD compliant per EN ISO 13485:2016 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (TC-XP-E), 48×2 dual-block (TC-XP-D), 384-well (TC-XP-F), or 4-slide in situ hybridization platform (TC-XP-H) |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Uniformity | ±0.4 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Control Range | 4–99.9 °C |
| Dimensions (L×W×H) | 470 × 340 × 260 mm |
| Net Weight | 10 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥3.0 °C/s |
| Temperature Accuracy | ≤±0.3 °C |
| Well-to-Well Temperature Uniformity | ≤±0.4 °C at 95 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-EA |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48-well (dual-format), 4-slide in situ hybridization module |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Range | 4–105 °C |
| Dimensions (L×W×H) | 368 × 250 × 285 mm |
| Net Weight | 10.5 kg |