Empowering Scientific Discovery

Beifen Sanpu JAHS-20A Plus Fully Automated Headspace Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Beifen Sanpu
Origin Beijing, China
Manufacturer Type OEM Manufacturer
Country of Origin China
Model JAHS-20A Plus
Price Upon Request
Sample Capacity 20 positions
Vial Size Compatibility 10 mL and 20 mL (customizable up to 100 mL)
Quantitative Loop Volume 1 mL (optional: 0.5 mL, 2 mL, 5 mL)
Sample Heating Range 40–220 °C (optional to 300 °C), ±0.5 °C stability
Valve & Transfer Line Heating Range 40–220 °C (optional to 300 °C), ±0.5 °C stability
Pressure Control 0–0.25 MPa (continuously adjustable)
Pressurization Time 0–999 s
Sampling Time 0–1800 s
Injection Time 0–999 s
Bake-out/Flush Time 0–1800 s
Minimum Time Resolution 1 ms
Carrier Gas Flow Control EPC-compatible (optional)
RSD <1.0% (for 100 ppm ethanol in water)
Interface USB 2.0
Compliance ASTM D6866, ISO 11843-2, USP <467>, FDA 21 CFR Part 11 ready (with optional audit trail software module)

Overview

The Beifen Sanpu JAHS-20A Plus Fully Automated Headspace Sampler is an engineered solution for precise, reproducible, and unattended volatile organic compound (VOC) extraction from solid and liquid matrices prior to gas chromatographic analysis. Based on the principle of equilibrium headspace sampling—where analytes partition between a sealed sample vial’s condensed phase and its vapor phase—the instrument thermally equilibrates samples under controlled temperature and pressure, then introduces the vapor-phase aliquot directly into the GC inlet via pressurized transfer. Designed for laboratories requiring high-throughput routine analysis—such as environmental testing labs (EPA Method 502.2, 8260D), pharmaceutical quality control (USP residual solvents), food safety (AOAC 2012.17), and forensic toxicology—the JAHS-20A Plus delivers robust automation without compromising analytical integrity. Its modular thermal zones, inert flow path architecture, and deterministic timing resolution ensure compliance with GLP/GMP workflows and support method validation per ICH Q2(R2) guidelines.

Key Features

  • 20-position carousel with automatic vial recognition and positional fault avoidance—prevents mechanical collision during loading/unloading even when vials are missing or misaligned
  • Triple-zone independent temperature control: sample incubation oven, six-port valve housing, and transfer line—all maintained within ±0.5 °C stability and calibrated traceable to NIST standards
  • Pressurized headspace injection using inert, de-activated fused-silica or SilcoNert®-treated stainless-steel tubing; zero dead volume design via integrated six-port valve + fixed-volume loop configuration
  • Motor-driven actuation system eliminates reliance on external compressed air or nitrogen—reducing infrastructure requirements and operational hazards
  • 7-inch TFT LCD touchscreen with intuitive graphical interface; animated workflow guidance enables rapid operator training and reduces procedural errors
  • Full parameter programmability via USB-connected PC or front-panel keypad—including pressurization, equilibration, sampling, injection, and post-run purge sequences
  • Built-in self-diagnostic routines: automatic initialization check, carousel homing verification, thermal sensor validation, and real-time error logging with descriptive alarm codes
  • Multi-mode sampling logic: single-vial multi-injection, single-vial single-injection, or sequential multi-vial single-injection—configurable per method step

Sample Compatibility & Compliance

The JAHS-20A Plus accommodates standard 10 mL and 20 mL crimp-top headspace vials (ASTM D3699-compliant), with optional adapters for 50 mL and 100 mL formats. It supports both aqueous and non-aqueous matrices—including polymers, soils, pharmaceutical tablets, beverages, and biological tissues—without matrix-specific hardware modification. All wetted surfaces employ high-inertness materials (e.g., Sulfinert®-coated valves, PTFE/septum-free capillary connections) to prevent adsorption, carryover, or catalytic degradation of reactive VOCs (e.g., formaldehyde, acetaldehyde, ethylene oxide). The system meets essential regulatory prerequisites for validated environments: temperature uniformity mapping per ISO/IEC 17025:2017 Annex A.3, electronic record integrity aligned with FDA 21 CFR Part 11 (when paired with compliant LIMS or GC data systems), and residue solvent quantification accuracy per USP Category 1–3 limits.

Software & Data Management

Instrument control and method development are performed through vendor-provided Windows-based software supporting method templates, sequence scheduling, and real-time monitoring of temperature profiles, pressure transients, and valve actuation timestamps. Raw metadata—including vial ID, run time, ambient conditions, and calibration status—is embedded in exported .csv or .txt files compatible with third-party chromatography data systems (CDS) such as Thermo Chromeleon, Agilent OpenLab CDS, and Shimadzu LabSolutions. Optional EPC integration enables closed-loop carrier gas flow regulation synchronized with injection events. Audit trail functionality—including user login history, parameter change logs, and electronic signatures—is available as a configurable module meeting ALCOA+ data integrity principles.

Applications

  • Pharmaceutical residual solvent analysis (ICH Q3C) across APIs and finished dosage forms
  • Environmental VOC screening in groundwater, wastewater, and soil extracts (EPA 8260D)
  • Flavor and fragrance profiling in beverages, dairy products, and fermented foods
  • Forensic toxicology screening for volatile intoxicants (e.g., ethanol, acetone, isopropanol) in blood and urine
  • Polymer outgassing studies for automotive, aerospace, and electronics packaging materials
  • Quality assurance of cleaning validation swabs and rinse solutions in biopharmaceutical manufacturing

FAQ

Is the JAHS-20A Plus compatible with Agilent and Shimadzu GC systems?

Yes—it provides TTL-level trigger outputs and accepts external start signals, enabling seamless synchronization with all major GC platforms via standard GC-start input interfaces.

Can the instrument be validated for GMP use?

Yes—full IQ/OQ documentation packages are available upon request, including temperature mapping reports, precision/repeatability test protocols, and traceable calibration certificates.

What maintenance intervals are recommended for long-term reliability?

Valve rotor seal replacement every 10,000 injections; transfer line bake-out weekly; quantitative loop inspection quarterly; full system performance verification annually.

Does it support dynamic headspace or purge-and-trap configurations?

No—the JAHS-20A Plus is designed exclusively for static equilibrium headspace sampling. Dynamic headspace requires dedicated purge-and-trap instrumentation.

Is remote monitoring possible over a LAN network?

Not natively—the current architecture relies on direct USB connection; however, integration with lab-wide SCADA or MES systems is feasible via OPC UA gateway solutions (third-party configured).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0