Empowering Scientific Discovery

Durawash NY-624N Textile Wash Durability Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand NYX
Origin Tianjin, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model NY-624N
Pricing Upon Request
Drum Speed 560 ± 2% rpm
Chamber Material SUS304 Stainless Steel
Wash Liquor Volume 40 L
Specimen Capacity Full Garments or 500 mm × 500 mm Printed/Dyed Fabric Samples
Temperature Range Up to 60 ± 2 °C (Adjustable)
Safety Features Low-Water Alert, Interlocked Door Sensor, End-of-Cycle Audible/Visual Notification
Timer Range 0–999 min (Programmable)
Power Supply AC 220 V, 50 Hz, 15 A
Operating Ambient 10–35 °C
Installation Floor-Mounted with Dedicated Inlet/Outlet Plumbing

Overview

The Durawash NY-624N Textile Wash Durability Tester is an engineered laboratory instrument designed to replicate standardized domestic and commercial laundering conditions for evaluating the wash fastness of printed and dyed textile substrates. It operates on the principle of controlled mechanical agitation within a heated, detergent-laden aqueous medium—mimicking the hydrodynamic shear, thermal stress, and chemical exposure experienced during real-world laundering cycles. The device complies with internationally recognized test protocols including Marks & Spencer’s C15 (Fabric Durability) and P5 (Print Durability) specifications, as well as BS 7907:2010 (Methods of test for colour fastness to washing), and DIN EN TR 16792:2015 (Textiles — Determination of colour fastness to domestic and commercial laundering). Its robust SUS304 stainless steel drum ensures corrosion resistance against alkaline detergents and repeated thermal cycling, while precise temperature regulation (±2 °C tolerance at setpoints up to 60 °C) and reproducible rotational speed (560 rpm ±2%) support method-consistent specimen exposure.

Key Features

  • High-fidelity simulation of M&S C15 and P5 test conditions, enabling direct compliance verification for global retail supply chain submissions
  • SUS304 stainless steel test chamber with seamless welds and polished interior surface for uniform fluid dynamics and long-term chemical resistance
  • Precisely regulated drum rotation at 560 ± 2% rpm, delivering consistent mechanical action across all load configurations
  • Programmable timer (0–999 minutes) with automatic shutdown and multi-stage cycle sequencing capability
  • Integrated safety architecture: door interlock prevents operation when open; low-water level sensor halts heating and agitation; audible and visual end-of-cycle alerts
  • Thermostatically controlled heating system with digital PID feedback loop ensuring ≤ ±2 °C deviation at nominal 60 °C operating point
  • 40-liter wash liquor capacity accommodating full-garment specimens or multiple 500 mm × 500 mm fabric swatches per run

Sample Compatibility & Compliance

The NY-624N accommodates both finished garments and flat textile specimens up to 500 mm × 500 mm, supporting evaluation of screen-printed, transfer-printed, digital-printed, and pigment-dyed surfaces. Its physical configuration and operational parameters align directly with the dimensional, volumetric, and kinetic requirements defined in BS 7907 Annex A and M&S Technical Bulletin TB-0011. All test reports generated using this instrument may be documented under GLP-compliant procedures, and raw data logs—including start time, duration, temperature profile, and cycle completion status—are traceable for internal audit or third-party certification review. While not intrinsically certified to ISO/IEC 17025, the instrument meets the performance criteria required for use in accredited testing laboratories performing ISO 105-C06, ISO 105-E01, and AATCC Test Method 61 validation studies.

Software & Data Management

The NY-624N operates via an embedded microcontroller interface with tactile keypad and LCD display—designed for reliability in industrial lab environments where network connectivity is limited or discouraged. No proprietary software is required for basic operation; however, optional RS-232 or USB-to-serial adapters enable timestamped export of cycle metadata (start time, set temperature, actual temperature at 1-min intervals, elapsed time, completion flag) into CSV format for integration with LIMS or QA documentation systems. All parameter settings are retained through power loss, and the unit supports user-defined test profiles stored in non-volatile memory. For laboratories operating under FDA 21 CFR Part 11 or EU Annex 11 requirements, external electronic logbooks may be configured to capture operator ID, test ID, and result correlation—ensuring audit-ready traceability without modifying the instrument’s firmware.

Applications

  • Pre-shipment validation of garment print durability for Marks & Spencer, Tesco, and other UK-based retailers requiring C15/P5 conformance
  • Developmental screening of reactive, disperse, and pigment-based ink systems for textile digital printing workflows
  • Comparative assessment of binder formulations used in screen and rotary printing pastes
  • Quality assurance testing of dye migration resistance in polyester-cotton blends subjected to high-temperature wash cycles
  • Supporting R&D for OEKO-TEX® Standard 100 Class II and III product certifications where wash fastness is a mandatory criterion
  • Internal benchmarking against ISO 105-C06:2010 (colour fastness to domestic and commercial laundering) for technical textile applications

FAQ

What standards does the NY-624N explicitly support?
It is validated for Marks & Spencer C15 (fabric durability) and P5 (print durability), BS 7907:2010, and DIN EN TR 16792:2015. It also satisfies the mechanical and thermal boundary conditions of ISO 105-C06 and AATCC TM61.
Can the instrument be used for ISO 105-C06 testing with standard steel balls and grey scale assessment?
Yes—when operated with the specified 40 L bath volume, 560 rpm drum speed, and 60 °C temperature setting, it meets the apparatus requirements outlined in Clause 5.1 of ISO 105-C06:2010.
Is plumbing installation mandatory?
Yes—the unit requires dedicated cold water inlet and gravity-fed drain outlet connections, as specified in the installation manual. Recirculation is not supported.
Does the NY-624N include calibration documentation?
Factory calibration certificates for temperature sensor (PT100 class B) and timer accuracy (±0.5 sec/hour) are provided with each unit. Periodic verification per ISO/IEC 17025 Section 6.4 is recommended annually.
What maintenance is required to ensure long-term repeatability?
Monthly cleaning of the drum interior and drain filter, biannual inspection of door gasket integrity, and annual verification of heater element resistance and thermocouple response time.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0