Empowering Scientific Discovery

Hach Pre-Packaged Reagent Sets for Total Chlorine Water Quality Testing

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Hach
Origin USA
Manufacturer Type Authorized Distributor
Product Origin Imported
Model Total Chlorine Test Kits
Price USD 36.50 (based on ¥280 at 7.67 CNY/USD)

Overview

Hach pre-packaged total chlorine reagent sets are precision-formulated, ready-to-use test kits engineered for rapid, accurate, and repeatable determination of total chlorine concentration in potable water, swimming pool systems, hospital water networks, and municipal drinking water treatment facilities. These reagents operate on the standardized DPD (N,N-diethyl-p-phenylenediamine) colorimetric method—fully compliant with EPA Method 334.0, ASTM D1253, and ISO 7393-2. The chemistry is optimized to detect combined chlorine (chloramines) and free chlorine simultaneously in a single-step reaction, delivering results within 2 minutes. Designed for field deployment and routine laboratory QC/QA workflows, each kit eliminates weighing, dilution, or calibration drift associated with bulk reagents—ensuring metrological traceability to NIST-traceable standards.

Key Features

  • Pre-measured, vacuum-sealed reagent vials—no pipetting, no weighing, no risk of cross-contamination
  • Stable shelf life of ≥24 months when stored at 2–25 °C; individually barcoded for lot traceability and inventory control
  • Compatible with Hach DR series spectrophotometers (e.g., DR3900, DR6000), portable colorimeters (e.g., Pocket Colorimeter II), and visual comparator methods (e.g., Model 2100P)
  • Measurement range: 0.02–10.00 mg/L Cl₂ as total chlorine (adjustable via sample dilution or instrument method selection)
  • Interference mitigation: Includes EDTA-based masking agents to suppress effects from monochloramine decomposition, high nitrite (>0.5 mg/L), or transition metals (e.g., Fe²⁺, Cu²⁺)
  • GLP-compliant documentation support: Each lot includes Certificate of Analysis (CoA) with assay value, uncertainty budget, and expiration date

Sample Compatibility & Compliance

Validated for use with clarified, filtered, or raw water samples exhibiting turbidity ≤10 NTU and pH 4.0–8.5. Not recommended for highly colored or oxidant-rich industrial effluents without matrix-specific validation. All kits meet regulatory requirements for drinking water compliance under US EPA Safe Drinking Water Act (SDWA) monitoring protocols and WHO Guidelines for Drinking-water Quality (4th ed.). For healthcare facility applications, kits align with CDC’s Guideline for Disinfection and Sterilization in Healthcare Facilities and Joint Commission EC.02.05.01 standards for water system surveillance. Full compliance documentation—including ISO/IEC 17025-accredited stability data and method validation reports—is available upon request for audit readiness.

Software & Data Management

When used with Hach’s AquaTrack™ or LabStation™ software platforms, reagent lot data auto-syncs to instrument method files, enabling automated lot-number logging, expiry alerts, and electronic record retention per FDA 21 CFR Part 11 requirements. Spectrophotometric measurements generate audit-trail-enabled PDF reports with embedded metadata (operator ID, timestamp, instrument serial number, reagent lot ID). Raw absorbance values and calibration curve parameters are exportable in CSV or XML formats for LIMS integration (e.g., Thermo Fisher SampleManager, LabVantage). No proprietary cloud subscription is required—on-premise deployment supports air-gapped network environments common in hospital central sterile supply departments (CSSD) and municipal utility SCADA-integrated labs.

Applications

  • Routine disinfectant residual monitoring in public swimming pools and spas (per CDC Model Aquatic Health Code §6.004)
  • Process control at chlorination contact basins and clearwells in drinking water treatment plants
  • Validation of point-of-use (POU) and point-of-entry (POE) disinfection systems in healthcare settings
  • Emergency response testing during distribution system maintenance or after main breaks
  • Regulatory reporting for state primacy agencies (e.g., TCEQ, NYSDOH) under Total Coliform Rule and Long-Term 2 Enhanced Surface Water Treatment Rule (LT2ESWTR)
  • Educational labs and environmental science curricula requiring CLIA-waived, low-risk analytical procedures

FAQ

Are these reagents compatible with non-Hach instruments?
Yes—when paired with spectrophotometers calibrated at 515 nm (DPD oxidation peak), provided wavelength accuracy is ±2 nm and photometric repeatability meets ±0.005 AU. Validation against Hach reference standards is strongly recommended.

What is the detection limit when using visual comparison?
0.2 mg/L Cl₂ with the Hach Model 2100P comparator, under controlled ambient lighting (CIE Standard Illuminant D65).

Do I need to perform daily calibration verification?
No—each vial contains a pre-validated chromophore yield. However, daily instrument blank verification and weekly secondary standard check (e.g., Hach Chlorine Standard Solution, Cat. No. 2702300) are required per EPA QA/QC guidance.

Can these kits be used for wastewater effluent testing?
Not without matrix-specific method validation. High organic load or suspended solids may quench the DPD reaction; refer to Hach Method 10069 for wastewater-adapted protocols.

Is cold chain shipping required?
No. Refrigeration is unnecessary; however, prolonged exposure above 35 °C degrades reagent stability. Storage below 25 °C is advised for optimal shelf-life retention.