| Model | Generic Digital Titrator for Laboratory Consumables & Accessories |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 1720E |
| Configuration | Online |
| Measurement Range | 0.0001–9.9999 NTU and 10.000–99.999 NTU (auto-ranging) |
| Resolution | 0.0001 NTU (0–9.9999 NTU) |
| Operating Temperature | 0–50°C (single-sensor), 0–40°C (dual-sensor) |
| Accuracy | ±2% of reading or ±0.015 NTU (whichever is greater) for 0–10 NTU |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | 1720E |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0.0001–9.9999 NTU and 10.000–99.999 NTU (auto-ranging) |
| Resolution | 0.0001 NTU (0–9.9999 NTU) |
| Accuracy | ±2% or ±0.02 NTU (whichever is greater) for 0–40 NTU |
| Repeatability | Better than ±1.0% of reading or ±0.002 NTU (whichever is greater) |
| Response Time | Step response, initial response ~75 seconds |
| Signal Averaging Options | 6, 30, 60, or 90 seconds (user-selectable |
| Sample Flow Rate | 200–750 mL/min |
| Operating Temperature | 0–50°C (single-sensor configuration) |
| Sample Temperature Range | 0–50°C |
| Analog Output | 0/4–20 mA (programmable over 0–100 NTU range) |
| Relay Outputs | Three SPDT relays (230 VAC, 5 A), configurable for alarm or control setpoints |
| Power Supply | 100–230 VAC, 50/60 Hz (auto-sensing) |
| Inlet Fitting | 1/4" NPT female + 1/4" compression fitting (included) |
| Drain Fitting | 1/2" NPT female + 1/2" hose barb (included) |
| Digital Communication Protocols | MODBUS RTU over RS-485 and RS-232 |
| Compliance Standards | Standard Method 2130B, USEPA Method 180.1, Hach Method 8195 |
| Enclosure Rating | NEMA-4X / IP66 |
| Dimensions (Controller) | 25.4 × 30.5 × 40.6 cm |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 1900C Economical |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Operating Temperature | 0–50 °C |
| Accuracy | ±1.5% FS |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 1900C |
| Product Type | Portable |
| Measurement Range | 0–9.99 NTU, 0–99.9 NTU, or 0–1000 NTU (auto-ranging or manual range selection) |
| Resolution | 0.01 NTU (at lowest range) |
| Operating Temperature | 0–50 °C |
| Accuracy | ≤1% (0–1000 NTU) |
| Repeatability | ≤1% (0–1000 NTU) |
| Zero Drift | ±1.5% F.S. |
| Stability | ±1.5% F.S. |
| Linearity Error | 1% |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Weight | 520 g |
| Compliance | EPA Method 180.1 |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 1900C |
| Measurement Principle | Nephelometric (90° light scattering) per USEPA Method 180.1 |
| Range | 0–1000 NTU (auto-ranging) |
| or manual ranges | 0–9.99 / 0–99.9 / 0–1000 NTU |
| Resolution | 0.01 NTU (at lowest range) |
| Accuracy | ±1% linearity error |
| Repeatability | ≤1% (0–1000 NTU) |
| Zero Drift | ±1.5% F.S. |
| Stability | ±1.5% F.S. |
| Power | 4 × AA alkaline batteries or optional AC adapter |
| Operating Temperature | 0–50 °C |
| Weight | 520 g |
| Compliance | Fully compliant with USEPA Method 180.1 |
| Optical System | Dual-detector ratiometric optical design with signal averaging |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Manufacturer |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | UV/Persulfate |
| Measurement Principle | NDIR Detection of CO₂ after Acidification and Catalytic Oxidation |
| Measurement Range | 0–5 mg/L to 0–20,000 mg/L (multi-range) |
| Accuracy | ±2% of reading (non-diluted), ±4% (diluted) |
| Detection Limit | ≤0.015 mg/L at 25°C (0–5 mg/L range) |
| Response Time | T₉₀ ≤ 8 min, T₂₀ ≤ 3 min |
| Sample Pressure | 0.15–6 bar (2–87 psig) |
| Flow Rate | 25–200 mL/min |
| Operating Temperature | 2–70°C (sample), 5–40°C (ambient) |
| Humidity | ≤80% RH at 31°C |
| Communication | RS232/RS485 (optional) |
| Analog Output | Dual 4–20 mA |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Dimensions | 981 × 675 × 20 mm |
| Weight | 54 kg |
| Compliance | USEPA Method 415.1, Standard Methods 5310C, ISO 8027 |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 2100AN |
| Measurement Principle | Nephelometric (90° light scattering) with dual-detector ratio mode |
| Turbidity Range | 0–10,000 NTU |
| Color Range | 0–500 CU |
| Accuracy | ±2% of reading (0–1000 NTU), ±5% (1000–4000 NTU), ±10% (4000–10,000 NTU) |
| Resolution | 0.001 NTU / 1 CU |
| Repeatability | ±1% of reading or 0.01 NTU |
| Minimum Sample Volume | 20 mL |
| Compliance | EPA Method 180.1 |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing at 25 °C) |
| Power Supply | 230 V, 50/60 Hz |
| Weight | 3.43 kg |
| Data Output | Built-in thermal printer, USB interface for HachLink™ software |
| Sample Chamber Purge | Compressed air port for dew prevention |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Type | Benchtop/Laboratory |
| Measurement Range | Turbidity: 0–10,000 NTU |
| Color | 0–500 CU |
| Resolution | Turbidity: 0.001 NTU |
| Color | 1 CU |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing at 25 °C) |
| Accuracy | Turbidity: (1) 0–1,000 NTU: ±0.01 NTU or ±2% of reading |
| (2) 1,000–4,000 NTU | ±5% of reading |
| (3) 4,000–10,000 NTU | ±10% of reading. Color: (1) 0–30 CU: ±2 CU |
| (2) 0–500 CU | ±5 CU |
| Compliance | EPA Method 180.1 |
| Sample Volume | ≥20 mL |
| Measurement Units | NTU, NEP, EBC, ABS, T%, CU, and user-defined units |
| Repeatability | ±1% of reading or ±0.01 NTU |
| Power Supply | 230 V, 50/60 Hz |
| Weight | 3.43 kg |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 2100N |
| Product Type | Benchtop / Laboratory |
| Measurement Range | 0–4000 NTU |
| Resolution | 0.001 NTU |
| Operating Temperature | 10–40 °C |
| Accuracy | ±2% (0–1000 NTU), ±5% (1000–4000 NTU) |
| Power Supply | 230 V, 50/60 Hz |
| Relative Humidity | ≤90% RH (non-condensing at 25 °C) |
| Sample Volume | ≥20 mL |
| Measurement Modes | NTU, NEP, EBC |
| Ratio Measurement | Yes |
| Data Storage | Internal memory with HachLink™ software export capability |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 2100N |
| Form Factor | Benchtop/Laboratory |
| Measurement Range | 0–4000 NTU |
| Resolution | 0.001 NTU |
| Operating Temperature | 10–40 °C |
| Accuracy | ±2% (0–1000 NTU) |
| Sample Volume | 20 mL minimum |
| Measurement Modes | NTU, NEP, EBC |
| Ratio Measurement | Yes |
| Power Supply | 230 V, 50/60 Hz |
| Relative Humidity | ≤90% RH (non-condensing at 25 °C) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 2100N |
| Price | Upon Request |
| Range | 0–4000 NTU |
| Accuracy | ±2% of reading (0–1000 NTU), ±5% of reading (1000–4000 NTU) |
| Resolution | 0.001 NTU |
| Minimum Sample Volume | 20 mL |
| Measurement Modes | NTU, NEP, EBC |
| Ratio Measurement | Yes |
| Signal Averaging | Programmable |
| Sample Chamber Purge | Compressed air compatible |
| Operating Environment | 10–40 °C, ≤90% RH (non-condensing at 25 °C) |
| Power Supply | 230 V, 50/60 Hz |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 2100P |
| Form Factor | Portable (Lab-Grade) |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU (at lowest range) |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–50 °C |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Weight | 520 g |
| Compliance | EPA Method 180.1 |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 2100Q |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Accuracy | ±2% of reading + stray light contribution |
| Stray Light | < 0.02 NTU (FNU) |
| Compliance | EPA Method 180.1 |
| Optical Principle | Ratio-based 90° scattered light detection with simultaneous transmission compensation |
| Ingress Protection | IP67 (excluding sealed cover and battery compartment) |
| Data Storage | 500 measurement records with timestamp, operator ID, sample ID, calibration status, and error logs |
| Power Options | 4 × AA alkaline batteries, rechargeable NiMH batteries (with USB+Power Module), or AC adapter (100–240 V, 50/60 Hz) |
| Interface | USB (supports 22 languages including English) |
| Measurement Modes | Normal, Signal Average, Rapid Settling Turbidity (RST) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 2100Q |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU (at lowest range) |
| Operating Temperature | 0–50 °C |
| Accuracy | ±2% of reading plus stray light contribution |
| Stray Light | < 0.02 NTU (FNU) |
| Measurement Principle | Ratio method—90° scattered light and transmitted light detection |
| Regulatory Compliance | EPA Method 180.1 |
| Light Source | Tungsten lamp |
| Calibration Options | Single-point (0–40 NTU), full-range (0–1000 NTU), or turbidity-to-suspended solids (0–100 mg/L) |
| Calibration Memory | Last 25 successful calibrations |
| Data Storage | Up to 500 measurements with timestamp, operator ID, sample ID, mode, units, calibration status, and error logs |
| Signal Averaging | User-selectable On/Off |
| Reading Modes | Normal, Signal Averaging, Fast-Settling Turbidity |
| RST (Rapid Settling Turbidity) Algorithm | Yes |
| Interface | USB + power module (optional) for direct PC transfer without proprietary software |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 2100Q |
| Measurement Range | 0–1000 NTU |
| Accuracy | ±2% of reading + stray light contribution |
| Stray Light | < 0.02 NTU (FNU) |
| Resolution | 0.01 NTU at lowest range |
| Calibration Options | Single-point RapidCal (0–40 NTU), Full-range (0–1000 NTU), and Turbidity-to-TSS correlation (0–100 mg/L) |
| Data Storage | Up to 500 measurements with timestamp, operator ID, sample ID, calibration status, and error logs |
| Compliance | 2100Q complies with USEPA Method 180.1 |
| Signal Averaging | User-selectable On/Off |
| Measurement Modes | Normal, Signal-Averaged, Rapid-Settling Turbidity (RST) |
| Display Guidance | On-screen calibration & verification prompts |
| Data Transfer | USB + power module (no additional software required) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Hach 2582sc Trace Dissolved Oxygen Analyzer |
| Pricing | Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 3400 |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Pen-style |
| Application Environment | Industrial process, laboratory, and field monitoring |
| Conductivity Range | 0–200,000 µS/cm |
| TDS Range | 0–400,000 ppm |
| Resistivity Range | 0.001–20 MΩ·cm |
| Temperature Range | −20 to +200 °C |
| Accuracy | ±0.01% of reading |
| Minimum Resolution | 0.1 µS/cm |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | 3700E |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Pen-style |
| Conductivity Range | 0–2,000,000 µS/cm |
| TDS Range | 0–9,999 ppm |
| Salinity Range | 0.0–200% |
| Temperature Range | −10 to +200 °C |
| Accuracy | ±0.01% of reading across all ranges |
| Minimum Resolution | 0.1 µS/cm |
| Sensor Interface | Digital (HACH SC-series compatible) |
| Cable Assembly | 6 m sensor cable + 1 m extension cable with digital adapter |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 5000 Online Silicon |
| Measurement Range | 0–5000 ppb as SiO₂ |
| Detection Limit | <0.5 ppb |
| Accuracy | ±0.5 ppb or ±1.0% of reading (whichever is greater) |
| Response Time | 8.8 min (sample temperature 30–50 °C) |
| Ambient Operating Temperature | 10–45 °C |
| Sample Pressure Requirement | 5 ± 3 psig (34.5 ± 20.7 kPa) |
| Sample Flow Rate | 100–300 mL/min |
| Analog Outputs | 0–0.01 V, 0–0.1 V, 0–1 V, or 4–20 mA (user-configurable range) |
| Power Supply | 115/230 VAC, 50–60 Hz |
| Alarm Outputs | 2 concentration alarms, 1 system warning alarm, 1 system shutdown alarm |
| Enclosure Rating | NEMA 4X / IP65 (ABS plastic) |
| Mounting Options | Benchtop or panel-mount |
| Reagent Delivery | Patented pressure-driven reagent metering system |
| Calibration Modes | Programmable auto-calibration with three selectable methods |
| Channel Configuration | Configurable up to 8-channel silicon analysis |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 5000 Phosphate |
| Measurement Principle | Ascorbic Acid Method (Standard Colorimetric) |
| High-Range Measurement | 0–50.0 mg/L PO₄ |
| Low-Range Measurement | 0–5000 µg/L PO₄ |
| Accuracy (High Range) | ±0.5 mg/L or ±5% of reading (whichever is greater) |
| Accuracy (Low Range) | ±4 µg/L |
| Detection Limit | <0.2 mg/L |
| Resolution (Low Range) | 1 µg/L |
| Reagent Delivery | Patented Pressure-Driven System |
| Calibration Options | Manual, Scheduled Automatic, and Programmable Standard Addition |
| Zero Adjustment | Fully Automated per Cycle |
| Diagnostic Capability | Built-in Self-Diagnostic Alarms |
| Flow Interruption Response | Auto-Shutdown & Recovery Protocol |
| Reagent Consumption | Optimized for Extended Unattended Operation |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HACH 5500sc |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Ammonia, Monochloramine, Free Ammonia |
| Range | 0.01–2 ppm as N |
| Accuracy | ±5% or 0.01 ppm (as N) at 5–40 °C |
| Repeatability | ±3% or 0.01 ppm (as N), whichever is greater |
| Detection Limit | 0.01 ppm as N |
| Response Time | <5 minutes |
| Sample Flow Rate | 100–1000 mL/min |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Sample Pressure | 0.17–6.0 bar |
| Sample Temperature | 5–50 °C |
| Power Output | 4 × 0/4–20 mA (600 Ω max load) |
| Communication Options | Modbus RS-485, Profibus DP (with external controller) |
| Enclosure Rating | NEMA 4X / IP56 |
| Dimensions | 804 × 452 × 360 mm |
| Weight | 20.5 kg (empty) |
| Certifications | CE, cETLus, Australian RCM |
| Brand | Hach |
|---|---|
| Model | 8315, 8316, 8317 |
| Construction Material | 316 Stainless Steel |
| Measurement Range | 0.057 µS/cm to 20,000 µS/cm |
| Compliance | ISO 7888, ASTM D1125 |
| Output Signal | 4–20 mA analog or digital (via Hach SC1000/SC200 controller) |
| Process Connection | 3/4" NPT or DIN 11851 sanitary thread (model-dependent) |
| Operating Temperature | 0–80 °C |
| IP Rating | IP68 |
| Calibration | Manual or automatic (with compatible Hach controllers) |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | 8362sc |
| Pricing | Upon Request |
| Measurement Range | pH 2–12 |
| ORP | −1500 to +1500 mV |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±0.05 pH / ±3 mV (at 25 °C, conductivity >1 μS/cm, stable flow) |
| Enhanced Accuracy Mode | ±0.01 pH / ±3 mV (same conditions) |
| Repeatability | 0.01 pH |
| Temperature Sensor Accuracy | ±0.1 °C (0–80 °C) |
| Ambient Operating Temperature | 0–60 °C |
| Ambient Humidity | 0–100 % RH (non-condensing) |
| Sample Flow Rate | 100–300 mL/min |
| Max Sample Pressure | 4 bar (at 25 °C) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 9073 |
| Ion Type | Sodium |
| Measurement Range | 0–0.01 ppb and 0–10,000 ppm (user-selectable) |
| Repeatability | <5% of reading or ±0.05 ppb (whichever is greater) |
| Response Time (T90) | <2 min |
| Analog Outputs | Two 4–20 mA outputs (max. load: 900 Ω) |
| Operating Temperature | 5–45 °C |
| Power Supply | 220 VAC, 50/60 Hz |
| pH Conditioning Required | Yes (pH >10) |
| Electrode Type | Sodium-selective glass electrode |
| Calibration Method | AUTOCAL (automated 1- or 2-point standard addition) |
| Sample Handling | Integrated pH adjustment and acid-tolerant configuration available |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported |
| Model | 9184sc |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 9184sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (HOCl-selective Membrane) |
| Measurement Parameter | Free Chlorine (as HOCl) |
| Range | 0.005–20 ppm (mg/L) HOCl |
| Accuracy | ±2% of reading or ±10 ppb HOCl (whichever is greater) |
| Detection Limit | 5 ppb (0.005 mg/L) HOCl |
| Response Time (t₉₀) | <90 seconds |
| Sample Flow Rate | 200–250 mL/min (automatically regulated) |
| Operating Temperature | 0–45 °C |
| Sample Temperature Range | 2–45 °C |
| Sample pH Range | 4–8 |
| Calibration Interval | Every 2 months |
| Membrane & Electrolyte Replacement Interval | Every 6 months |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions | 270 × 250 mm |
| Storage Temperature | −20–60 °C |
| Inlet/Outlet Fittings | 1/4″ O.D. inlet, 1/2″ I.D. outlet |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 9185sc |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 9187sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | ClO₂ (Chlorine Dioxide) |
| Range | 0.010–2 ppm (mg/L) ClO₂ |
| Accuracy | ±5% of reading or ±10 ppb ClO₂, whichever is greater |
| Repeatability | 0.02 mg/L |
| Resolution | 0.01 ppm |
| LOD | 10 ppb (0.01 mg/L) ClO₂ |
| Response Time (t₉₀) | <90 s |
| Sample Flow Rate | 200–250 mL/min |
| Operating Temperature | 0–45 °C |
| Sample Temperature Range | 0–45 °C |
| Storage Temperature | −20 to 60 °C |
| Calibration Interval | Every 2 months |
| Membrane & Electrolyte Replacement Interval | Every 6 months |
| Inlet Connection | 1/4-in. O.D. tubing |
| Outlet Connection | 1/2-in. I.D. tubing |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions | 270 × 250 mm (10.63 × 9.84 in.) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | Accu4/T53 |
| Configuration | Online Turbidimeter |
| Measurement Range | 0.000–1.000, 0.00–10.00, 0.0–100.0 NTU |
| Resolution | 0.001 NTU |
| Accuracy | ±2% of reading |
| Repeatability | <0.1% of full scale |
| Operating Ambient Temperature | −20 to +60 °C |
| Sample Temperature Range | 0 to 60 °C |
| Sample Flow Rate | 0.19–26.5 L/min |
| Max Sample Pressure | 50 psig |
| Enclosure Rating | NEMA 4X (IP65) |
| Analog Outputs | Two isolated 4–20 mA outputs |
| Relay Outputs | Four SPDT relays |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Light Source | Long-life LED |
| Compliance | EPA Method 180.2 (GLI Method 2) |