Empowering Scientific Discovery

Hanna HI98121 Portable pH/ORP/Temperature Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Hanna Instruments
Origin Italy
Model HI98121
Instrument Type Portable
Parameter Type Multi-Parameter (pH, ORP, Temperature)
pH Range -2.00 to 16.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.05 pH @ 25°C
ORP Range ±1000 mV
ORP Resolution/Accuracy 1 mV / ±2 mV
Temperature Range -5.0 to 60.0°C (23.0 to 140.0°F)
Temperature Resolution/Accuracy 0.1°C / ±0.5°C
Calibration Auto-recognition 1–2 point pH calibration (built-in buffers: pH 4.01/7.01/10.01 and pH 4.01/6.86/9.18)
ATC Automatic temperature compensation (-5.0 to 60.0°C)
Power 4 × 1.5 V button cells (LR44)
Dimensions 163 × 40 × 26 mm
Weight 75 g
IP Rating Not specified
Operating Environment -5 to 50°C, up to 100% RH
Auto-off 8 minutes

Overview

The Hanna HI98121 is a compact, field-ready portable meter engineered for simultaneous measurement of pH, oxidation-reduction potential (ORP), and temperature in aqueous solutions. It operates on the fundamental electrochemical principles of potentiometric measurement: pH is determined via the Nernst equation using a glass electrode and reference junction, while ORP is measured as the open-circuit potential (in millivolts) relative to a stable Ag/AgCl reference system. Temperature is acquired via an integrated thermistor sensor, enabling real-time automatic temperature compensation (ATC) across the full operational range (−5.0 to 60.0°C). Designed for reliability in variable environmental conditions — from industrial wastewater monitoring to academic fieldwork and quality control in food processing — the HI98121 delivers laboratory-grade repeatability without requiring benchtop infrastructure. Its robust ABS housing, low-power consumption architecture, and intuitive two-button interface support extended deployment in non-climate-controlled settings while maintaining traceable measurement integrity.

Key Features

  • True multi-parameter capability: Simultaneous display of pH, mV (ORP), and °C/°F on a single high-contrast LCD screen with dedicated unit indicators.
  • Auto-recognition pH calibration: Supports 1- or 2-point calibration with built-in buffer recognition for three standard pH sets (4.01/7.01/10.01 and 4.01/6.86/9.18), eliminating manual buffer selection errors.
  • Factory-calibrated ORP channel: Delivers immediate usability with ±2 mV accuracy; verification and maintenance supported by Hanna’s traceable redox standards (e.g., HI7021 at 240 mV ±50 mV @ 25°C).
  • Automatic temperature compensation (ATC): Integrated thermistor ensures pH and ORP values are corrected per ISO 7027 and ASTM D1293 guidelines for temperature-dependent electrode response.
  • Low-power design: Powered by four LR44 button cells with battery-level indicator and configurable 8-minute auto-off to extend operational life beyond 200 hours.
  • Ergonomic portability: Weighing only 75 g with dimensions of 163 × 40 × 26 mm, it fits comfortably in a lab coat pocket or field kit without compromising structural rigidity or electrode port sealing.

Sample Compatibility & Compliance

The HI98121 is validated for use with standard combination pH/ORP electrodes (e.g., HI1285-5, HI1296B) in liquid-phase samples meeting general aqueous compatibility requirements: conductivity > 50 µS/cm, total dissolved solids (TDS) < 10,000 ppm, and absence of strong oxidizers or organics that may foul the reference junction. It complies with IEC 61010-1:2010 safety standards for electrical equipment used in measurement, control, and laboratory applications. While not certified for GLP/GMP environments out-of-the-box, its calibration traceability (via Hanna-certified buffers), stable mV output, and ATC functionality align with foundational data integrity expectations under FDA 21 CFR Part 11 when paired with documented SOPs and manual audit trails. It is suitable for routine testing referenced in EPA Method 9040C (pH), ASTM D512 (chloride interference assessment), and USP (pH measurement in pharmaceutical preparations).

Software & Data Management

The HI98121 operates as a standalone instrument with no onboard data logging or Bluetooth connectivity. All measurements are displayed in real time and intended for immediate transcription or visual verification. This design prioritizes operational simplicity, electromagnetic immunity, and long-term stability in harsh environments where wireless modules may introduce drift or interference. For laboratories requiring electronic records, Hanna recommends pairing the HI98121 with external documentation protocols — including handwritten logbooks compliant with ISO/IEC 17025 clause 7.7 or spreadsheet-based entry validated per ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate). Electrode performance verification using HI7021 (240 mV ±50 mV @ 25°C) and conditioning with HI7091 (reducing) or HI7092 (oxidizing) solutions supports consistent inter-laboratory comparability.

Applications

  • Environmental monitoring: Field measurement of surface water, effluent streams, and leachate pH/ORP during site assessments per ASTM D3693 and EPA SW-846 Method 9040.
  • Food & beverage QA/QC: Spot-checking brine solutions, fermentation tanks, and rinse waters where rapid pH and redox status inform microbial stability decisions.
  • Aquaculture and hydroponics: Daily tracking of nutrient solution acidity and oxidation state to maintain optimal ion availability and pathogen suppression.
  • Education and training: Undergraduate chemistry labs utilize the HI98121 for introducing core electrochemical concepts — including Nernstian slope validation, junction potential effects, and temperature dependency — due to its transparent calibration logic and stable baseline response.
  • Maintenance diagnostics: Verification of electrode health prior to critical measurements using standardized redox checks, reducing unplanned downtime in production-critical processes.

FAQ

What calibration buffers are pre-programmed into the HI98121?
The meter recognizes two standard pH buffer sets: (1) pH 4.01, 7.01, and 10.01; and (2) pH 4.01, 6.86, and 9.18 — all referenced at 25°C. Buffer identification is automatic upon immersion.
Is ORP calibration required before use?
No. The ORP channel is factory-calibrated and ready for immediate measurement. Users should verify electrode function using HI7021 Redox Standard Solution (240 mV ±50 mV @ 25°C) before critical measurements.
How does automatic temperature compensation (ATC) improve measurement reliability?
ATC applies real-time correction to pH readings based on the thermistor-measured sample temperature, compensating for the inherent temperature dependence of the Nernst slope (≈0.198 mV/pH unit/°C deviation from 25°C), per ISO 3696 and ASTM E70.
Can the HI98121 be used in high-salinity or low-conductivity samples?
It is optimized for conductive aqueous media (>50 µS/cm). In deionized water or ultrapure solvents, unstable readings and slow stabilization may occur due to increased electrical resistance across the reference junction.
What is the recommended electrode maintenance protocol?
Rinse with deionized water after each use; store the combination electrode in HI70300 storage solution. If ORP drift exceeds ±50 mV from HI7021 reference, condition with HI7091 (reducing) or HI7092 (oxidizing) solution per Hanna’s technical bulletin TB002.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0