Empowering Scientific Discovery

GOW-MAC Instrument Co.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTiger HALO 3 H₂O
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200DID
Detector TypeHelium Discharge Ionization Detector (DID)
Detection Limit<5 ppb
Linear Dynamic Range>10⁶
Column Oven Temperature Range+10 °C to 150 °C
Column FormatMicro-packed and 1/8″ packed columns
Flow ControlPrecision Mass Flow Controllers
Sample IntroductionPneumatically Actuated Gas Sampling Valve
Valve ConfigurationsBackflush, Column Selection, Heart-Cut, Series/Bypass
Construction MaterialsElectropolished Stainless Steel with VCR Fittings
Operating ModesManual (for method development) and Fully Automated (for continuous process analysis)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
ModelGM-816
Detection Limit<5 ppb (CH₄, with DID detector)
Linear Dynamic Range>10⁶
Maximum Detector Capacity3 simultaneous detectors (e.g., DID-V, TCD, FPD, FID)
Column/Valve ConfigurationUp to 10 columns and 5 multi-dimensional switching valves
Flow ControlElectronic Pressure Control (EPC)
Power Supply220 V ±10%, 2250 W
Connection StandardVCR fittings for low-dead-volume gas pathways
Valve Oven ProtectionIntegrated valve box with thermal stabilization and contamination isolation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 582
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range0–450 °C
Oven Ramp Rate0.1–50 °C/min
Cool-down Time~4 min (450 °C to 10 °C)
Carrier Gas Flow Range & Control0–45 mL/min
Carrier Gas Pressure Range & Control0–120 kPa
Injector Maximum Operating Temperature450 °C
Injector Pressure Setting Range0–120 kPa
Injector Total Flow Setting Range0–45 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 836 Series
Instrument TypeLaboratory Gas Chromatograph
Column ConfigurationUp to 8 Valves & 10 Columns
Oven Temperature RangeAmbient +4°C to 450°C
Max Ramp Rate120°C/min
Cooling Time450°C to 50°C in ≤4 min
Temperature Resolution0.1°C
Oven Program Steps20–21 ramps
Detector CapacityUp to 3 Independent, Thermally Controlled Detectors
Detector OptionsDID, TCD, FID, PID, FPD, NPD
Flow ControlElectronic Pressure Control (EPC)
Dimensions58 cm × 54 cm × 56 cm
Detection Limits5 ppb (CH₄, DID), 20 ppb (CH₄, FID), 2×10⁻⁹ g/mL (CₙHₘ, TCD), 1×10⁻¹² g (C₆H₆, PID), 50 ppb avg. (FPD), 10 ppb avg. (NPD)
Response Times<0.5 s (DID, TCD, PID), 1 ms (FID)
Linear Dynamic Ranges10⁴–10⁷ (detector-dependent, log-log scale)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200
Instrument TypeOnline Gas Chromatograph
Detector OptionsTCD, DID, FID, PID, NPD, FPD
Column CompatibilityPacked & Micro-packed Columns
Sample IntroductionGas Sampling Valve & Liquid Sampling Valve
Valve ConfigurationUp to 3 Pneumatically Actuated Valves
Oven Temperature Range+10 °C to 150 °C
SoftwareClarity PC Chromatography Data System (CDS)
ConstructionStainless Steel Flow Path
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 1300
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range0–450 °C
Ramp Rate0.1–40 °C/min
Cooling Rate450 °C to 10 °C in ~5 min
Carrier Gas Flow Range & Control0–30 mL/min
Carrier Gas Pressure Range & Control0–100 kPa
Injector Max Operating Temperature450 °C
Injector Pressure Setpoint Range0–100 kPa
Injector Total Flow Setpoint Range0–30 mL/min
Detection Limit10 ppb (N₂ in He)
Detection PrincipleHelium Plasma Emission Spectroscopy
Output Signal4–20 mA analog + dry contact alarms
Configuration Options0–2/0–20 ppm or 0–20/0–200 ppm dual-range modes
Power Options115 V AC or 230 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelMIDAC Dynamic Calibration System
Price RangeUSD 42,000 – 70,000 (FOB)
Instrument TypeLaboratory Gas Chromatography Calibration Standard Generator
Application ScopeUniversal Calibration for GC & FTIR
Gas Dilution StagesTriple-stage
Mass Flow Controllers (MFCs)Multi-channel digital MFC support
Corrosive Gas CompatibilityYes (acidic, alkaline, organic)
Dilution Ratio ProgrammabilityYes, time-scheduled auto-run
Real-time Flow MonitoringYes
Repeatability≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm)
Control InterfacePLC-based with 7″ TFT touchscreen (800×600)
PLC Cycle TimeStandard mode 160 µs
Onboard MemoryDisplay buffer 26 MB
Touchscreen Lifetime≥ 5 years (MTBF)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGM 816 TCD
Instrument TypeLaboratory Gas Chromatograph
Detector TypeThermal Conductivity Detector (TCD)
Application ScopeUniversal for Specialty Gas Analysis
Dimensions (with valve box)82 × 54 × 48.5 cm
Dimensions (without valve box)58 × 54 × 48.5 cm
Analog OutputsDual-channel (1 mV and 1 V)
Column Configuration SupportUp to 10 columns and 7 valves
Baseline CompensationSingle-column dual-channel
Corrosion-Resistant Gas PathwayYes
Diagnostic CapabilitiesReal-time circuit, temperature, and leak diagnostics with automated error alerts and remediation guidance
SoftwareCustomizable chromatography software package supporting remote instrument control, data acquisition, processing, and report generation
Remote AccessBrowser-based UI for method/sequence editing, system log access, and real-time status monitoring
Compliance ContextDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model210 ACE
Detection PrincipleHydrogen Flame Ionization Detection (FID) with High-Selectivity Gas Chromatographic Separation
Detection Limit<30 ppb
Linear Dynamic Range>6 orders of magnitude
ComplianceISBT Standard for Acetaldehyde in Beverage-Grade CO₂
InstallationBenchtop or Rack-Mountable
Control InterfaceFront-panel keypad + optional PC-based software with audit trail capability
Data OutputReal-time concentration display, analog output (4–20 mA), digital logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model880
Operating Temperature400 °C ± 0.2 °C
Temperature Stability±0.2 °C at 400 °C
Heating PowerMax 160 W, Steady-State ~50 W
Dimensions14 × 19 × 31 cm
Input Voltage220 VAC, 50 Hz
Purification Capacity≤200 mL/min (recommended: 100 mL/min)
Output Purity<10 ppb total non-inert impurities (from 5N feed gas)
Compatible Carrier GasesHe, Ar, Ne, Kr, Xe, N₂, H₂
Removable ImpuritiesH₂O, O₂, N₂, H₂, CO, CO₂, CH₄, NOₓ, NH₃, CF₃, CCl₄, SiH₄, low-boiling hydrocarbons
Non-removableHe, Ne, Ar, Kr
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model75-902
Operating Temperature Range0–250 °C
Maximum Working Pressure300 atm
Sample Gas Flow Rate30–50 mL/min
Power Supply230 VAC, 500 W
Dimensions (D×W×H)39.37 cm × 16.51 cm × 30.48 cm
Weight6.80 kg
Inlet Connection1/8″ VCR
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
ModelGM-800
Price RangeUSD 14,000 – 42,500 (FOB)
Linearity Error±2% FS
Repeatability<0.5% FS
Drift<1% FS/7 days
Response Time≤60 s
Explosion ProtectionNot rated
Sensor TypeImported Electrochemical Oxygen Sensor
Output Signal4–20 mA DC (isolated), RS-485 Modbus RTU
Power Supply220 VAC ±10%, 50/60 Hz
Operating Temperature0–45 °C
Enclosure RatingIP65
Calibration IntervalRecommended every 3–6 months
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGM 902
Detector OptionsElectrochemical, Catalytic Bead, NDIR, TCD, PID
Measurement Unitsppm, mg/m³, vol%, %LEL, pphm, ppb, mg/L
Sampling MethodIntegrated diaphragm pump with hydrophobic particulate filter and moisture trap
Environmental RatingSuitable for high-humidity ambient air sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model1400
Measurement Range0–2 ppm / 0–20 ppm / 0–200 ppm H₂O in Ar
Accuracy±0.02 ppm (0–2 ppm), ±0.25 ppm (0–20 ppm), ±2.50 ppm (0–200 ppm)
Response Time (t₉₀)≤10 s
Sample Flow Rate2 scfh (0.88 slpm)
Inlet/Outlet Fittings1/4" VCR inlet, 1/4" Swagelok outlet
Operating Temperature16–35 °C
Max Inlet Pressure10 psig
Detector TypeMicrowave-Induced Plasma Emission Spectroscopy (MIP-ES)
Sensitivity±0.01 ppm (Model 1400-A/1402-A), ±0.10 ppm (Model 1400-B/1402-B)
Output4–20 mA analog + dry contact alarms
Power100 W, 115/230 VAC, 50/60 Hz
Dimensions13.34 × 42.23 × 37.15 cm
Weight11.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 210 SA
Detection PrincipleFlame Photometric Detection (FPD)
Detection TargetTotal Sulfur in Gaseous or Liquid CO₂
Detection Limit<5 ppb for COS
Linear Dynamic Range>3 orders of magnitude
ComplianceISBT Methods 13 & 14
InstallationBenchtop or Rack-Mountable
Operating ModeContinuous or Discrete Flow
CalibrationAutomated Onboard Calibration
Temperature ControlFactory-Set Constant-Temperature Detection Zone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelA16
Instrument TypeLaboratory Gas Dilution Calibrator
Application ScopeUniversal Calibration for Trace Gas Analyzers
Dilution Ratio Range1:10 to 1:10,000 (typical)
Flow Control Accuracy±0.5% of setpoint
Pressure Regulation Range0–100 psig
Temperature Stability±0.1 °C (ambient-controlled environment)
Output Port ConfigurationDual independent calibrated outlets
ComplianceASTM D6420, ISO 6145-3, EPA Method 205
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model21070
Detection PrincipleThermal Conductivity Differential Sensing
Calibration TraceabilityNIST-Traceable Standards
Power Supply115 V / 230 V AC, 50/60 Hz, 4 W
BatteryRechargeable NiMH, 3.6 V, 1650 mAh
Continuous Operation~15 hours
Charge Time<60 min to 95% capacity
Operating Temperature21 °C ± 11 °C (70 °F ± 20 °F)
Dimensions13.34 × 8.26 × 4.60 cm (L × W × H)
Weight0.48 kg (instrument only), 0.28 kg (charger)
DisplayAdjustable-brightness LED bar graph with peak-hold function
Pump TypeDiaphragm
Sensitivity RangeLow (×1) and High (×100) selectable
Response Time Constant & AveragingUser-adjustable
Zero Drift CompensationManual
Audio AlarmAdjustable threshold and volume
Data RetentionFlash memory for user settings
ComplianceDesigned for industrial leak screening per ASTM E2921 and ISO 10648-2 (qualitative detection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
Model20600
Detection PrincipleThermal Conductivity Detection (TCD)
Detector TypeSealed-reference-cell TCD with four filament elements (rhenium-tungsten, tungsten, nickel)
Response Time<10 s
Power SupplyRechargeable battery or AC adapter
CalibrationDual-range, user-configurable for specific binary gas pairs
SensitivityCalibratable to 0.5% O₂ in air
DisplayIntegrated LCD showing direct % concentration reading
Sample HandlingIntegrated diaphragm pump
ComplianceDesigned for field-deployable industrial process monitoring and leak verification per ASTM D1946 and ISO 8573-5 guidelines
Operating EnvironmentPortable, ruggedized housing for ambient industrial site use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGAOMAI
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelGM Explosion-Proof Enclosure
Price RangeUSD 70,000 – 140,000
Instrument TypeExternal Protective Enclosure for Portable Gas Chromatographs
Application ScopeGeneral-Purpose Hazardous Area Deployment
Explosion Protection RatingExdp II BT1 to Exdp II CT6 (GB 3836 Compliant)
IP RatingIP65
Internal Pressure Range30–100 Pa
Power Supply220 VAC ±10%, 50 Hz
Construction MaterialsEP-grade stainless steel tubing (welded or VCR-fitted)
Viewing WindowShatter-resistant explosion-proof borosilicate glass
Certification BasisGB 3836.1–2010, GB 3836.5–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
ModelGM 1900
OriginBeijing, China
Detector OptionsDID-V, TCD, FID
Detection Limit (CH₄)<10 ppb
Operating ModeContinuous 24/7 online analysis
Temperature ControlMicroprocessor-regulated inlet, column oven, and detector zones
User InterfaceHigh-resolution resistive touch LCD panel
Corrosion ProtectionWet-coated wetted surfaces
Compliance FeaturesBuilt-in self-diagnostic, purge gas safeguard, auto-reboot on power recovery, alarm logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 1200
Detection PrinciplePlasma Emission Spectroscopy
Measurement Range0–2 ppm, 0–10 ppm, 0–20 ppm, 0–100 ppm, 0–200 ppm N₂ in Ar
Accuracy±0.02 ppm (0–2 ppm range), ±0.25 ppm (0–10/0–20 ppm ranges), ±2.50 ppm (0–100/0–200 ppm ranges)
Sensitivity±0.01 ppm (Model 1200-A/1202-A), ±0.10 ppm (1200-B/1202-B), ±1.00 ppm (1200-C/1202-C)
Sample Flow Rate2 scfh (0.88 slpm)
Inlet/Outlet Fittings1/4" VCR inlet, 1/4" Swagelok outlet
Operating Temperature16–35 °C (60–95 °F)
Max Inlet Pressure10 psig
Measurement Cell Pressure6 psig
Normal Inlet Pressure2–7 psig
Output Signals4–20 mA analog, dry contact alarms
Power100 W, 115/230 VAC, 50/60 Hz
Dimensions13.34 × 42.23 × 37.15 cm
Weight11.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelClarity
Software TypeChromatography Data System (CDS)
Regulatory Compliance21 CFR Part 11, GLP/GMP-ready
Deployment OptionsClarity (Full), Clarity Lite (Single-Instrument), Clarity Offline (Post-Run Analysis), Clarity SDK (OEM Integration), Clarity OEM (White-Label Customization)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGOW-MAC
OriginUSA
ModelGOW-MAC 200C
Instrument TypeOnline Gas Chromatograph
Application ScopeUniversal Trace Gas Analysis
Detector OptionsPDHID, TCD, FID
Minimum Detection Limit (CH₄)<10 ppb
ConstructionCorrosion-Resistant Wetted Surface Coating
Control InterfaceHigh-Resolution Touchscreen LCD
Compliance ReadyASTM D7623, ISO 8573-5, USP <621>, FDA 21 CFR Part 11 (Software Audit Trail Enabled)