HORIBA OM-51 Portable Dissolved Oxygen Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HORIBA
Origin Japan
Model OM-51
Measurement Principle Galvanic Cell with Gas-Permeable Membrane
Dissolved Oxygen Range 0.00–19.99 mg/L (Resolution: 0.01 mg/L)
Saturation Range 0.0–199.9 % (Resolution: 0.1 %)
Temperature Range 0.0–50.0 °C (Resolution: 0.1 °C)
Accuracy (DO) ±0.1 mg/L ±1 digit
Repeatability (DO) ±0.1 mg/L ±1 digit
Power Supply DC 3 V (2 × AA/LR6 batteries)
Weight Approx. 300 g

Overview

The HORIBA OM-51 Portable Dissolved Oxygen Meter is a field-deployable, galvanic cell-based instrument engineered for rapid, reliable measurement of dissolved oxygen (DO), oxygen saturation (% air saturation), and temperature in natural waters, wastewater, aquaculture systems, and laboratory-prepared samples. Unlike polarographic sensors requiring polarization time or frequent calibration, the OM-51 employs a self-polarizing galvanic cell with a gas-permeable Teflon membrane—enabling immediate stabilization upon immersion and eliminating warm-up delays. Its compact, handheld architecture integrates a high-contrast LCD display and intuitive single-button operation, optimized for routine monitoring under variable ambient conditions. The device conforms to standard electrochemical principles defined in ASTM D888 and ISO 5814, supporting traceable DO quantification in compliance with environmental data quality objectives for field surveys and regulatory reporting.

Key Features

  • Galvanic sensor design with integrated temperature compensation—no external probe required; temperature is measured simultaneously with DO via built-in thermistor.
  • Multi-parameter display: simultaneous readout of dissolved oxygen (mg/L), saturation (%), and temperature (°C) on a single screen.
  • High-resolution measurement: 0.01 mg/L resolution in DO mode and 0.1 °C resolution across the full 0.0–50.0 °C operating range.
  • Robust mechanical construction: IP67-rated housing ensures dust-tightness and temporary water immersion resistance—suitable for riverbank, pond-side, or effluent channel use.
  • Low-power operation: powered by two standard AA (LR6) alkaline batteries, delivering up to 200 hours of continuous use without replacement.
  • No zero-point calibration required—factory-calibrated sensor maintains stability over extended deployment intervals, reducing operational overhead in multi-site monitoring programs.

Sample Compatibility & Compliance

The OM-51 is validated for use in freshwater, seawater (with salinity compensation applied manually per user-entered value), treated effluents, and process water streams. It complies with fundamental performance criteria outlined in EPA Method 360.1 and ISO 5814:2012 for electrochemical DO determination. While the instrument itself does not generate electronic audit trails, its analog output and manual data recording workflow align with GLP-compliant field documentation practices when paired with standardized logbooks and chain-of-custody forms. For applications requiring formal validation (e.g., municipal wastewater compliance), users are advised to perform periodic verification using Winkler titration or certified air-saturated water standards.

Software & Data Management

The OM-51 operates as a standalone field instrument without embedded Bluetooth, USB, or proprietary software connectivity. All measurements are displayed in real time and must be recorded manually. This design prioritizes operational simplicity, battery longevity, and immunity to electromagnetic interference—critical attributes for remote deployments where wireless infrastructure is unavailable or unreliable. Users may integrate OM-51 data into broader environmental information systems (EIS) or LIMS platforms through secondary transcription or spreadsheet import. For laboratories requiring automated data capture, HORIBA recommends pairing the OM-51 with external logging accessories (e.g., compatible analog-to-digital converters) or upgrading to the OM-52 series, which supports RS-232 output and optional PC interface modules compliant with FDA 21 CFR Part 11 requirements.

Applications

  • Field-based assessment of aerobic zones in rivers, lakes, and reservoirs during ecological surveys.
  • Real-time monitoring of dissolved oxygen profiles in aquaculture tanks and hatchery recirculation systems.
  • Pre- and post-treatment verification in municipal and industrial wastewater treatment plants.
  • Educational demonstrations of oxygen dynamics in limnology and environmental science curricula.
  • Baseline characterization of groundwater and surface water prior to remediation activities.
  • Emergency response screening during algal bloom events or chemical spills affecting aquatic respiration capacity.

FAQ

Does the OM-51 require membrane replacement or electrolyte refilling?
No—the OM-51 uses a sealed, maintenance-free galvanic cell with pre-filled electrolyte and factory-installed membrane. Sensor lifetime is typically 12–18 months under normal field use; replacement probes (OM-51-P) are available as consumables.
Can the OM-51 measure DO in seawater?
Yes, but salinity must be manually entered (0–50 ppt) to apply appropriate saturation correction. The meter does not include automatic salinity sensing.
Is temperature compensation automatic?
Yes—temperature is measured continuously via an integrated thermistor, and all DO readings are automatically compensated to 20 °C or reported at actual sample temperature, depending on user selection.
What is the recommended calibration frequency?
HORIBA specifies factory calibration traceability; field verification against air-saturated water (at known temperature and barometric pressure) is recommended before each day’s sampling session or after prolonged storage.
Is an AC adapter included?
No—the AC adapter is an optional accessory (model ADP-OM). Battery operation remains the primary and supported power mode.