Empowering Scientific Discovery

NIUMAG PQ001-sl Low-Field NMR Analyzer for Simultaneous Oil and Moisture Content in Animal Feed

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand NIUMAG
Origin Jiangsu, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model PQ001-sl
Pricing Upon Request
Magnet Type Permanent Magnet
Magnetic Field Strength 0.5 ± 0.08 T
Probe Coil Diameter 25 mm

Overview

The NIUMAG PQ001-sl is a dedicated low-field nuclear magnetic resonance (LF-NMR) analyzer engineered for rapid, non-invasive, and simultaneous quantification of oil and moisture content in animal feed formulations. Unlike conventional destructive methods, this instrument leverages the intrinsic relaxation behavior of hydrogen nuclei (1H) in different molecular environments—specifically, the distinct transverse relaxation times (T2) of bound water, immobilized water, and free oil components. In feed matrices, water is predominantly associated with protein and carbohydrate networks (exhibiting shorter T2), whereas triglyceride-based oils reside in mobile, unbound phases (displaying longer T2). By applying a CPMG (Carr–Purcell–Meiboom–Gill) pulse sequence and deconvoluting the multi-exponential T2 decay spectrum, the PQ001-sl isolates and quantifies these two populations with high reproducibility. The system operates at a stable static field of 0.5 ± 0.08 T generated by a temperature-compensated permanent magnet, eliminating cryogen dependency and enabling robust deployment in QC laboratories and production floors.

Key Features

  • Simultaneous dual-parameter output: absolute oil content (%) and moisture content (%) from a single 60–180 second acquisition
  • Non-destructive analysis: intact pellets, crumbles, mash, or ground samples require no homogenization, drying, or solvent exposure
  • Minimal sample preparation: <5 g of representative material placed directly into standard 25 mm OD glass tubes; no calibration against reference standards required for routine use
  • Permanent magnet architecture: zero liquid helium or nitrogen consumption; ambient-temperature operation with <±0.01 T/h field drift under stabilized lab conditions
  • Integrated RF probe: fixed-tuned 25 mm diameter solenoid coil optimized for signal-to-noise ratio across typical feed T2 ranges (0.1–500 ms)
  • Embedded pulse sequence control: pre-configured CPMG with adjustable echo spacing (0.1–2.0 ms), number of echoes (32–2048), and repetition time (1–10 s)

Sample Compatibility & Compliance

The PQ001-sl accommodates heterogeneous feed samples—including extruded pellets (2–8 mm diameter), expanded crumbles, powdered premixes, and raw grain blends—without size-reduction preprocessing. Its measurement principle is insensitive to particle morphology, density gradients, or surface reflectivity, ensuring consistent results regardless of granulation uniformity. Method validation aligns with principles outlined in AOAC Official Method 991.36 (NMR for oil in seeds) and ASTM D7465-19 (Standard Practice for Quantitative Analysis by Low-Field NMR). While not FDA-cleared as a medical device, the instrument supports GLP-compliant data integrity when operated with audit-trail-enabled software configurations. All firmware and acquisition protocols are traceable to internal version control logs, satisfying basic 21 CFR Part 11 readiness requirements for electronic records in regulated feed manufacturing environments.

Software & Data Management

Bundled NIUMAG NMR-Analyzer v4.x software provides intuitive workflow management: automated T2 inversion using non-negative least squares (NNLS), customizable region-of-interest integration for oil/water peak separation, and batch processing for up to 96 samples per session. Raw FID and T2 spectra are stored in vendor-neutral HDF5 format with embedded metadata (timestamp, operator ID, pulse parameters, temperature). Calibration curves can be generated using gravimetric reference sets or certified reference materials (CRMs); slope, intercept, and R2 values are auto-recorded with uncertainty propagation. Export options include CSV, PDF reports compliant with ISO/IEC 17025 documentation templates, and direct LIMS integration via OPC UA or RESTful API endpoints.

Applications

  • Real-time QC monitoring of extrusion process consistency across soybean meal, corn gluten, fishmeal, and palm kernel expeller batches
  • Verification of post-drying moisture stability in pelleted feeds prior to packaging and storage
  • Raw material acceptance testing for oilseed deliveries (e.g., rapeseed, sunflower) where rapid fat profiling informs blending ratios
  • Stability studies assessing lipid oxidation kinetics via longitudinal T2 shift tracking in accelerated shelf-life trials
  • Supporting formulation optimization by correlating NMR-derived oil/moisture ratios with pellet durability index (PDI) and digestibility assays

FAQ

Does the PQ001-sl require daily shimming or field homogeneity adjustment?

No. The permanent magnet system is factory-shimmed and thermally stabilized; routine operation requires only ambient temperature control (20–25°C) and avoidance of strong external magnetic sources.
Can the instrument differentiate between free water and bound water?

Yes—through multi-component T2 analysis, it resolves at least three relaxation populations: bound water (T2 < 10 ms), intermediate water (10–100 ms), and free oil (T2 > 100 ms); moisture reporting defaults to total water unless user-defined thresholds are applied.
Is method transfer possible between different PQ001-sl units?

Yes. Inter-unit reproducibility is maintained within ±0.3% absolute for oil and ±0.15% for moisture across identical sample sets, provided probe coils and pulse sequences are matched per NIUMAG’s inter-system calibration protocol.
What maintenance is required beyond routine cleaning?

Annual verification of magnet temperature stability and RF amplifier linearity; no consumables or scheduled replacement parts are specified in the first five years of operation.
Does the system support IQ/OQ/PQ documentation packages for regulated facilities?

Yes—NIUMAG provides configurable GxP-ready qualification templates aligned with ISO 13485 and feed safety HACCP frameworks upon request.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0