Showing 1–30 of 317 results
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 T |
| Spatial Resolution | ≤ 235 µm (isotropic) |
| Scan Time | As low as 8–9 min per sequence |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded, Zero Stray Field |
| Regulatory Compliance | CE Marked, Designed for GLP-Compliant Preclinical Research |
| Application Focus | Mouse Phenotyping, Longitudinal In Vivo Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Field Homogeneity | <10 ppm over 20 mm DSV |
| Gradient Strength | ≥200 mT/m |
| Gradient Slew Rate | ≥1000 T/m/s |
| Spatial Resolution | ≤200 µm isotropic (typical in vivo mouse brain) |
| Scan Time | <10 minutes per standard sequence |
| Cooling | Passive (no cryogens or chiller required) |
| Shielding | Self-shielded, zero fringe field beyond instrument footprint |
| Regulatory Compliance | CE Marked, IEC 61000-6-3/6-4, ISO 13485–certified manufacturing processes |
| Software Platform | Aspect ImageSuite v5.x (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3-mice |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Spatial Resolution | ≤ 235 µm (isotropic, typical in vivo) |
| Scan Time | As low as 8–9 minutes per sequence (T1- or T2-weighted) |
| Cooling | Passive (no cryogens or chillers required) |
| Shielding | Self-shielded, zero fringe field beyond system footprint |
| Compliance | Designed for ISO 13485-aligned manufacturing and GLP-compliant preclinical research environments |
| Software Platform | Aspect ImageSuite™ v5.x (FDA 21 CFR Part 11–ready audit trail, DICOM 3.0 export, multi-sequence reconstruction pipeline) |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5 |
| Instrument Type | Nuclear Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Weight Capacity | Up to 700 g (mouse/rat) |
| Imaging Modes | 2D/3D, In Vivo, Ex Vivo, In Vitro |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded (Zero Stray Field) |
| Typical Resolution | ≤ 234 µm (T2-weighted), ≤ 195 µm (T1-weighted) |
| Acquisition Time | ~4.8–9.1 min per scan |
| Compliance | Designed for ISO 13485-aligned lab environments |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Model | EDUMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Form Factor | Integrated RF-Temperature Control / Spectrometer / Power Control Cabinet |
| Target Use | Undergraduate & Graduate Teaching Laboratory |
| Regulatory Context | Designed for GLP-aligned educational validation and ISO/IEC 17025-compatible pedagogical traceability |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EDUMR-I |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 15 mm |
| Effective Sample Volume | Ø12.5 mm × H25 mm |
| Image Linearity (x/y/z) | >90% |
| Spatial Resolution | <0.08 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | EDUMR-MRI |
| Type | Benchtop NMR Imaging System for Education |
| Magnet Field Strength | 0.5 T (Permanent Magnet) |
| Operating Frequency | ~21.3 MHz (¹H) |
| Gradient Strength | ≥15 G/cm |
| RF Coil Options | Standard 25 mm & 50 mm Diameter Surface Coils |
| Data Interface | USB 3.0 + Ethernet |
| Software Platform | EDU-Imaging Suite v4.x with DICOM Export, K-Space Access, and Pulse Sequence Editor |
| Compliance | CE Marked, Meets IEC 61000-6-3/6-4 EMI/EMC Requirements |
| Safety Class | Class I, EN 61010-1 |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EDUMR20-015V |
| Pricing | Available Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | EDUMR20-015V-2 |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (NMR) Imaging System |
| Sample Compatibility | Solid-Liquid Dual-Phase Samples |
| Form Factor | Desktop Permanent Magnet Platform |
| Compliance | Designed for educational use under IEC 61000-4 electromagnetic compatibility standards and aligned with ISO/IEC 17025 laboratory competence guidelines for teaching instrumentation |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | EDUMR20-015V-3 |
| Field Strength | 0.5 T ± 0.03 T |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Form Factor | Desktop Benchtop System |
| Compliance | Designed for Educational Use in Biomedical Engineering and Medical Physics Curricula |
| Software Platform | Integrated Virtual Data Acquisition & Image Reconstruction Teaching Environment |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | EDUMR20-015V-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Imaging System |
| Sample Compatibility | Solid and Liquid Samples |
| Magnetic Field Strength | 0.5 T ± 0.03 T |
| Form Factor | Desktop Permanent Magnet System |
| Application Domain | MRI Physics Education, Biomedical Engineering Pedagogy, Medical Imaging Training |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EDUMR20-015V-I |
| Instrument Type | Benchtop MRI System |
| Sample Compatibility | Solid and Liquid Samples |
| Magnet Type | Permanent Magnet |
| Static Field Strength | 0.5 ± 0.08 T |
| Probe Coil Diameter | 15 mm |
| Effective Sample Volume | Ø12.5 mm × H25 mm |
| Image Linearity (x/y/z) | >90% |
| Spatial Resolution | <0.08 mm |
| Data Access | Raw k-space data export enabled |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EDUMR20-015V-I |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | EDUVMR |
| Pricing | Upon Request |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Full-Diameter Core Analyzer |
| Instrument Type | Low-Field NMR Spectrometer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnetic Field Strength | 6.2 MHz |
| Minimum Echo Time (TE) | 0.1 ms |
| Longitudinal Spatial Resolution | 1 cm |
| Maximum Core Length | 3.4 cm |
| Maximum Core Diameter | 115 mm |
| Capabilities | T₁/T₂ Relaxometry, T₁–T₂ Two-Dimensional Correlation Mapping |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5-Rat |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Spatial Resolution | ≤100 µm (in-plane, 3D gradient-echo mode) |
| Imaging Modes | T1-weighted, T2-weighted, PD-weighted, 2D/3D spin-echo and gradient-echo sequences |
| Application Focus | In vivo rodent musculoskeletal phenotyping, arthritis progression monitoring, preclinical OA model validation |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Magnet Type | Permanent Magnet |
| Static Magnetic Field Strength | 0.5 ± 0.08 T |
| Larmor Frequency | 21.3 MHz |
| Probe Coil Diameter | 60 mm |
| Application Domain | Geological Core Analysis, Petrophysical Characterization, Soil & Cement Hydration Monitoring |
| Compliance Framework | Designed for ASTM D7264 (flexural properties), ISO 10427 (NMR porosity/permeability correlation), and GLP-aligned data integrity workflows |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MacroMR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase |
| Operating Frequency | 21 MHz |
| Operation Mode | Pulsed NMR |
| Magnet Type | Permanent Magnet (NdFeB) |
| Magnetic Field Strength | 0.3 ± 0.05 T |
| Uniformity Region | Accommodates Multiple Probe Configurations |
| Bore Geometry | C-Type Semi-Open Structure |
| Sample Access | Horizontal Push-Pull Loading |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MacroMR Series |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet (NdFeB) |
| Field Strength | 0.3 ± 0.05 T |
| Uniformity Zone | Designed for Multi-Configuration Probe Integration |
| Core Functionality | T₂ Relaxometry, T₁–T₂ Correlation, NMR Imaging, Porosity & Permeability Quantification, Fluid Saturation Analysis, Wettability Assessment, Microstructural Heterogeneity Mapping |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MacroMR12-150H-I / MacroMR12-150H-HTHP (40 MPa-PMMR) / MacroMR12-110H-I |
| Magnetic Field Strength | 0.3 T ± 0.03 T |
| Magnet Homogeneity | ≤50 ppm |
| Magnet Type | C-shaped open configuration |
| Sample Orientation | Transverse or longitudinal |
| Sample Compatibility | Solid–liquid dual-mode |
| Instrument Class | Low-field NMR spectrometer |
| Compliance | Designed for ASTM D7169, ISO 10101-2, and coal seam gas evaluation protocols per GB/T 29173–2012 and API RP 44 |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MacroMR- |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Analyzer |
| Sample Mode | Solid–Liquid Dual Compatibility |
| Operating Principle | Pulsed Fourier Transform NMR |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid-Liquid Dual-Mode |
| Magnetic Field Strength | 0.3 T ± 0.03 T |
| Magnet Configuration | C-Type Open Magnet |
| Field Homogeneity | ≤50 ppm |
| Maximum Sample Dimension | Ø150 mm × H100 mm |
| Probe Orientation | Transverse/Longitudinal |
| Gradient System | Advanced Integrated Gradient Coil |
| Sample Diameter Range | 25–150 mm |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MacroMR-2 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase Core Samples |
| Field Strength | 0.3 T ± 0.03 T |
| Magnet Homogeneity | ≤50 ppm |
| Magnet Configuration | C-Type Open-Bore |
| Sample Access | Transverse/Longitudinal |
| Standard Operating Conditions | Up to 100 °C / 40 MPa (Customizable to 150 °C / 70 MPa) |
| Probe Options | 1–6 inch diameter |
| Core Imaging Capability | Real-Time T₁/T₂ Mapping & Dynamic Fluid Saturation Monitoring during In-Situ Displacement |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Mode |
| Magnetic Field Strength | 0.3 T ± 0.03 T |
| Magnet Homogeneity | ≤50 ppm |
| Magnet Configuration | C-Type Open Bore |
| Sample Chamber Diameter | Up to 6 inches (152 mm) |
| Maximum Sample Length | 250 mm |
| Standard Operating Environment | 100 °C / 40 MPa |
| Optional Extended Environment | Up to 200 °C / 100 MPa |
| Low-Temperature Capability | Down to −30 °C |
| Gradient Selection | Fixed-Gradient Slice-Selective Imaging |
| Pulse Sequences | Fully User-Accessible 1D/2D Relaxometry & Imaging Sequences |
| Software Platform | Proprietary Core Analysis Suite with GLP-Compliant Audit Trail |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase |
| Model | MacroMR-4 |
| Field Strength | 0.3 T ± 0.03 T |
| Magnet Homogeneity | ≤50 ppm |
| Magnet Configuration | C-Type Open-Bore |
| Sample Access | Transverse/Longitudinal |
| Maximum Sample Diameter | 6 in (152 mm) |
| Maximum Sample Length | 250 mm |
| Standard Operating Environment | 100 °C / 40 MPa |
| Optional Extended Environment | Up to 200 °C / 100 MPa |
| Low-Temperature Capability | Down to −30 °C |
| Supported Pulse Sequences | CPMG, Inversion Recovery, IR-CPMG, Diffusion-Weighted, 2D T₁–T₂, Gradient-Selected Slice Imaging |
| Gradient Selection | Constant-Gradient Slice Selection for Layered Analysis |
| Mechanical Integration | Pseudo-Triaxial Loading Compatibility |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MacroMR-5 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance Analyzer |
| Sample Type | Solid-Liquid Dual-Phase |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MacroMR12 |
| Quotation | Upon Request |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Dual-Phase |
| Operating Mode | Pulsed Fourier Transform |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.3 ± 0.05 T |
| Magnet Geometry | C-Shaped Open Configuration |
| Sample Temperature Range | Ambient to 100 °C |
| Optional Constant-Pressure/Constant-Flow Displacement Pump (0–40 MPa, Pressure Accuracy | ±0.25% FS |
| Flow Rate | 0.1–15 mL/min, Flow Accuracy: ±0.1 mL) |
| Optional Gas Booster System (Max Boost Pressure | ≤25 MPa) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MacroMR12-150H-1 |
| Magnet Type | Permanent Magnet (NdFeB) |
| Static Field Strength | 0.3 ± 0.05 T |
| Larmor Frequency | 12.8 MHz |
| Probe Coil Diameter | 150 mm |
| Effective Sample Volume | Ø150 mm × 100 mm |
| System Form Factor | Upright Cabinet with C-Shaped Magnet Bore |
| Sample Loading | Horizontal Sliding Tray |
| Digitization | Fully Digital NMR Spectrometer Platform |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | MacroMR12-150H-4 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Combined |
| Magnetic Field Strength | 0.3 T ± 0.03 T |
| Magnet Homogeneity | ≤50 ppm |
| Magnet Configuration | C-Type Open Design |
| Sample Access | Horizontal and Vertical |
| Maximum Sample Diameter | 4 inches (101.6 mm) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | MacroMR12-150H-HTHP |
| Magnetic Field Strength | 0.3 T ± 0.03 T |
| Sample Orientation | Transverse/Longitudinal |
| Magnet Type | C-shaped Open Permanent Magnet (NdFeB) |
| Maximum Sample Dimensions | Ø ≤ 25.4 mm × L ≤ 80 mm (under HTHP conditions) |
| Sample Compatibility | Solid–Liquid Dual-Phase Rock Cores |
| Temperature & Pressure Capability | Integrated High-Temperature High-Pressure (HTHP) Probe Support |
| Gradient System | High-Precision Active Gradient Coil Assembly |
| RF Probe | Temperature-Stabilized Broadband Tunable Probe |