SANXIN MP526 Dual-Parameter Conductivity & Dissolved Oxygen Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand SANXIN
Model MP526
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Measurement Range (Conductivity) 0–2000 mS/cm (6-range auto-scaling)
Measurement Range (DO) 0–40.00 mg/L and 0–200.0 % saturation
Accuracy (Conductivity) ±0.5% FS
Accuracy (DO) ±0.10 mg/L
Temperature Range −10 to 110 °C
Temp. Compensation (Conductivity) 0–50 °C
Temp. Compensation (DO) 0–45 °C
Salinity Compensation (DO) 0–45 ppt
Barometric Compensation (DO) 80–105 kPa
Data Storage 900 sets
Interface RS232
Power Supply DC 9 V / 300 mA
Dimensions & Weight 160 × 190 × 70 mm / 880 g
IP Rating IP54
GLP Compliance Yes

Overview

The SANXIN MP526 Dual-Parameter Conductivity & Dissolved Oxygen Meter is a benchtop laboratory instrument engineered for precision, reproducibility, and operational efficiency in routine water quality analysis. It integrates two fundamental electrochemical measurement principles—conductivity (via four-electrode or two-electrode AC conductivity cell methodology) and dissolved oxygen (via Clark-type polarographic sensing)—into a single, unified platform. The instrument employs frequency-adaptive excitation and automatic gain control to ensure stable, low-noise signal acquisition across six decades of conductivity (0.00 µS/cm to 2000 mS/cm), while its polarographic DO sensor features rapid polarization (3–5 min), integrated temperature, salinity, and barometric pressure compensation—enabling trace-level accuracy under variable field and lab conditions. Designed for compliance-driven environments, the MP526 conforms to GLP (Good Laboratory Practice) data integrity requirements, including timestamped measurement records, user-accessible calibration logs, and audit-ready parameter history.

Key Features

  • Auto-ranging conductivity measurement with six programmable segments and automatic electrode constant recognition (K = 0.1, 1.0, or 10)
  • One-point conductivity calibration capability for full-scale accuracy up to 100 mS/cm using K = 1 electrodes—enabled by proprietary auto-variable frequency and voltage regulation
  • Polarographic DO probe with replaceable membrane cap (DO503), pre-filled electrolyte (DO502), and <5-minute polarization time
  • Integrated barometric pressure sensor (80–105 kPa range) for real-time DO compensation without external input
  • Non-linear temperature compensation algorithm optimized for ultrapure water (≤10 µS/cm), eliminating systematic drift in low-conductivity applications
  • Automatic standard solution recognition for eight certified conductivity standards—supporting both US/EU (e.g., KCl 1413 µS/cm) and Chinese national standard series
  • Smart stirrer (Model 901) with synchronized speed control to minimize convection artifacts during DO and low-conductivity measurements
  • IP54-rated enclosure with silicone-sealed ports and ruggedized housing for humid or splash-prone lab environments

Sample Compatibility & Compliance

The MP526 is validated for use across diverse aqueous matrices—including drinking water, wastewater effluents, surface water, boiler feedwater, pharmaceutical purified water (PW), and cleanroom rinse solutions. Its conductivity module supports ASTM D1125 (Standard Test Methods for Electrical Conductivity and Resistivity of Water) and ISO 7888 (Water Quality — Determination of Electrical Conductivity). For dissolved oxygen, it aligns with ISO 5814 (Water Quality — Determination of Dissolved Oxygen — Electrochemical Probe Method) and APHA Standard Method 4500-O. All calibration, measurement, and maintenance events are timestamped and stored with operator ID (if enabled), satisfying GLP documentation requirements. While not FDA 21 CFR Part 11–certified out-of-the-box, the RS232 interface enables integration with validated LIMS or ELN systems supporting electronic signature and audit trail protocols.

Software & Data Management

Measurements are stored locally in non-volatile memory (900 datasets maximum), each containing date/time stamp, measured parameters (conductivity, DO, temperature, salinity, pressure), electrode IDs, calibration status, and operator notes (via optional keyboard input). Data export is supported via RS232 serial interface using ASCII-based protocol compatible with generic terminal emulators or custom Python/Excel VBA scripts. Firmware includes built-in diagnostics—electrode impedance monitoring, open-circuit detection, and battery voltage reporting—to preempt measurement failure. Clock synchronization, auto-shutdown timer, and stable-signal hold indicators further enhance procedural consistency during batch analysis.

Applications

  • Environmental monitoring labs performing EPA-compliant surface water and groundwater profiling
  • Pharmaceutical QC laboratories verifying conductivity specifications per USP for Purified Water and Water for Injection
  • Power generation facilities conducting boiler feedwater and condensate resistivity trending
  • Academic research groups studying oxygen dynamics in aquatic microcosms or bioreactor effluents
  • Food & beverage QA departments validating rinse water conductivity thresholds for CIP validation
  • Municipal wastewater treatment plants monitoring aeration basin DO setpoints and influent conductivity surges

FAQ

Does the MP526 support automatic calibration for both conductivity and dissolved oxygen?
Yes—conductivity supports one-point or multi-point calibration with automatic standard identification; DO supports dual-point calibration using air-saturated water and water-saturated air protocols.
Can the instrument measure high-conductivity samples such as seawater or brine?
Yes—when equipped with the optional 2310-C electrode (K = 10), the MP526 extends its upper range to 2000 mS/cm, suitable for concentrated saline solutions and industrial process streams.
Is temperature compensation applied independently for conductivity and DO measurements?
Yes—two independent thermal sensors enable simultaneous, parameter-specific compensation: 0–50 °C for conductivity and 0–45 °C for DO, both with configurable algorithms.
What is the minimum detectable conductivity level for ultrapure water applications?
With the DJS-0.1 electrode and activated non-linear compensation, the MP526 achieves reliable resolution down to 0.01 µS/cm in Type I ultrapure water (ASTM D5127), minimizing thermal drift artifacts.
How does the MP526 handle data integrity for regulated environments?
All measurements include embedded timestamps, calibration verification flags, and electrode usage counters—enabling traceability per GLP Annex 11 and ISO/IEC 17025 documentation requirements.