Empowering Scientific Discovery

Shimadzu GC-2014 Used Gas Chromatograph

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shimadzu
Origin China (Beijing)
Instrument Type Laboratory Gas Chromatograph
Application Field Environmental Analysis
Model GC-2014
Condition Refurbished & Fully Qualified

Overview

The Shimadzu GC-2014 is a robust, benchtop gas chromatograph engineered for reliable separation and quantitative analysis of volatile and semi-volatile organic compounds. Based on capillary column gas chromatography with flame ionization detection (FID) or optional electron capture (ECD), thermal conductivity (TCD), or nitrogen-phosphorus (NPD) detectors, the system operates on the fundamental principle of differential partitioning between a mobile phase (carrier gas) and a stationary phase (capillary column). Designed for routine laboratory use in environmental monitoring laboratories, the GC-2014 delivers high reproducibility in trace-level analyses—particularly for priority pollutants including BTEX (benzene, toluene, ethylbenzene, xylene), chlorinated hydrocarbons, pesticides, and polycyclic aromatic hydrocarbons (PAHs) in soil, water, and air samples.

Key Features

  • Modular oven architecture with precise temperature control across a wide operating range (typically 30–350 °C, configurable per installation)
  • Programmable temperature ramping (standard heating rate up to 40 °C/min; cooling rate dependent on ambient conditions and optional cryogenic accessories)
  • Dual independent inlet systems supporting split/splitless injection, with pressure and flow control via electronic pneumatic control (EPC) modules
  • Maximum injector temperature up to 350 °C, compatible with thermally stable capillary columns (e.g., DB-5ms, HP-5, Rtx-1)
  • Carrier gas compatibility with helium, hydrogen, or nitrogen; flow range typically 0.1–100 mL/min (dependent on detector configuration and column dimensions)
  • Integrated hardware diagnostics and real-time status monitoring via front-panel LCD and RS-232/USB interface
  • Refurbishment includes full mechanical inspection, detector performance validation, leak testing, column oven calibration, and firmware update to latest supported revision

Sample Compatibility & Compliance

The GC-2014 supports liquid, gaseous, and headspace-derived samples through standard 10–100 µL syringe injection or automated liquid sampler (ALS) integration. It complies with method requirements outlined in EPA Methods 502.2, 524.2, 8021B, and 8260C for environmental volatiles and semivolatiles. When configured with ECD or NPD, it meets select criteria under ISO 10301 (water quality — determination of organochlorine pesticides) and ASTM D5845 (determination of benzene in gasoline). All refurbished units undergo verification per Shimadzu’s internal QC protocol aligned with GLP principles, including baseline noise assessment (<0.5 pA), retention time stability (<0.02 min RSD), and area repeatability (<2.0% RSD for 5 injections of 1 ppm standard).

Software & Data Management

Data acquisition and processing are performed using Shimadzu’s GCsolution software (v2.7 or later), supporting dual-channel chromatogram display, peak integration with customizable baselines, calibration curve generation (linear, quadratic, or multi-point), and report export in PDF, CSV, or XML formats. The software supports audit trail functionality compliant with FDA 21 CFR Part 11 when deployed in validated environments—requiring user authentication, electronic signatures, and immutable event logging. Raw data files (.gcd) are stored in a hierarchical folder structure with timestamped metadata, enabling full traceability from acquisition to final report.

Applications

  • Environmental testing: VOC analysis in drinking water, wastewater, landfill leachate, and ambient air (via sorbent tube desorption)
  • Soil and sediment screening for petroleum hydrocarbons (TPH), PCBs, and organochlorine pesticides
  • Regulatory compliance monitoring for industrial effluents under local discharge permits
  • Method development and validation in contract testing laboratories serving municipal and third-party environmental service providers
  • Academic research in atmospheric chemistry, bioremediation kinetics, and contaminant fate modeling

FAQ

Is this instrument supplied with original Shimadzu documentation and certificates?
Yes—each unit includes scanned copies of the original factory shipment documents, service history logs (where available), and a post-refurbishment Certificate of Inspection signed by our ISO 9001-certified technical team.
What detector configurations are available for the GC-2014?
Standard configuration includes FID; optional detectors include ECD, TCD, and NPD—all verified for sensitivity and linearity during refurbishment.
Can the GC-2014 be integrated into a LIMS environment?
Yes—GCsolution supports ODBC-compliant database connectivity and can export structured results directly to LIMS platforms via defined schema templates.
What is the typical lead time for delivery and installation support?
Delivery occurs within 10–15 business days after order confirmation; on-site installation, qualification (IQ/OQ), and operator training are available as optional add-on services.
Does the instrument include a warranty?
All refurbished GC-2014 systems carry a 12-month limited parts-and-labor warranty covering defects in materials and workmanship under normal laboratory use conditions.