Thermo Scientific Orion 310D-24 Precision Benchtop Biochemical Oxygen Demand (BOD) Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin USA
Manufacturer Type Authorized Distributor
Origin Category Imported
Model 310D-24
Pricing Upon Request
Conductivity Range 0.000–3000 mS/cm
Conductivity Resolution Up to 0.001 µS/cm (4 significant digits)
Conductivity Accuracy ±0.5% of reading or ±0.01 µS/cm (whichever is greater)
Resistivity Range 0.0001–100 MΩ·cm
Salinity Range 0.01–80.0 ppt NaCl
TDS Range 0–19,999 mg/L
Cell Constant Range 0.001–199.9 cm⁻¹
Reference Temperatures 15°C, 20°C, or 25°C
Electrode Compatibility Two-electrode, four-electrode, and planar conductivity cells
Calibration Points 1–5 point
Temperature Range −5°C to 105°C
Temperature Resolution 0.1°C (−5°C to 99.9°C), 1.0°C (>99.9°C)
Temperature Accuracy ±0.1°C
Temperature Compensation Automatic or manual
Display Backlit LCD
Sensor Interfaces Conductivity – miniDIN
Communication Bidirectional RS232, optional USB cable
Data Storage 200 GLP-compliant measurements
Calibration History Last 10 calibrations
Method Storage 10 user-defined methods
Self-Diagnostic Function Yes
Password Protection Yes
Firmware/Method Update Network-enabled
Power Supply 4 × AA batteries or universal AC adapter (benchtop)
Safety Certifications CE, CSA, UL, TÜV, FCC Class A
Operating Environment 5–45°C, 5–85% RH
Ingress Protection IP54 (benchtop)

Overview

The Thermo Scientific Orion 310D-24 Precision Benchtop Biochemical Oxygen Demand (BOD) Analyzer is a dedicated, GLP-compliant instrument engineered for accurate, reproducible, and traceable BOD₅ and dissolved oxygen (DO) quantification in environmental, municipal wastewater, and regulatory compliance laboratories. Unlike generic DO meters, the 310D-24 integrates an auto-stirring polarographic or optical DO sensor (standard configuration) with intelligent oxygen consumption kinetics modeling—enabling direct, real-time BOD estimation via Winkler-based or respirometric principles per ASTM D5210, ISO 5815-1, and EPA Method 405.1. Its core architecture combines high-stability analog signal conditioning, temperature-compensated amperometric detection, and dual-mode measurement logic (static DO endpoint vs. dynamic O₂ depletion rate), ensuring metrological integrity across diverse sample matrices—from low-conductivity surface waters to high-salinity industrial effluents. Designed for routine batch analysis of up to 24 samples per run (hence the “24” designation), it supports standardized 5-day incubation workflows while maintaining full auditability under regulated environments.

Key Features

  • Integrated auto-stirring DO electrode with optimized diffusion membrane and built-in magnetic stir control—eliminates manual agitation variability and ensures uniform oxygen mass transfer during BOD incubation.
  • Intelligent Smart Stability™ algorithm dynamically adjusts response threshold based on signal noise profile, reducing stabilization time by up to 40% without compromising precision.
  • Smart Averaging™ function applies weighted moving-average filtering to raw sensor output, improving repeatability (RSD < 0.8% at 8 mg/L DO) in turbid or particulate-laden samples.
  • Full conductivity module (0.000 µS/cm–3000 mS/cm) enables simultaneous salinity, TDS, and resistivity verification—critical for correcting BOD results per USP and ISO 5815-2 dilution factor validation.
  • Onboard self-test diagnostics verify electrode polarization voltage, reference junction integrity, temperature sensor linearity, and internal power rail stability prior to each measurement cycle.
  • 10 password-protected method slots allow lab managers to preconfigure BOD protocols—including incubation duration, temperature setpoint (20°C ±0.5°C), blank correction logic, and unit reporting (mg/L O₂ or ppm)—for operator-specific SOP enforcement.

Sample Compatibility & Compliance

The 310D-24 accommodates standard 300-mL BOD bottles (glass or PET), as well as custom vials compatible with multi-position incubators. Its conductivity and temperature modules support validation of sample dilution water per Standard Methods 5210B and ISO 5815-1 Annex A—ensuring conductivity ≤ 2.0 µS/cm and temperature equilibration within ±0.2°C. The system complies with FDA 21 CFR Part 11 when equipped with optional secure software licensing, delivering electronic signatures, audit trails for all calibration events and data edits, and immutable storage of raw sensor timestamps. All stored records meet GLP requirements per OECD 113 and EU Directive 2009/128/EC, including mandatory fields: operator ID, sample ID, instrument serial number, calibration date/certification ID, ambient pressure, and incubation start/stop times.

Software & Data Management

Data are stored locally in non-volatile memory with full GLP metadata embedding: 200 measurement records retain date/time stamps, sensor serial numbers, calibration coefficients, and user annotations. The last 10 calibration logs include slope/mV offset, zero current, cell constant, and standard concentrations used—exportable via RS232 or USB to LIMS or Excel-compatible CSV files. Firmware and method updates are performed over Ethernet or Wi-Fi using Thermo’s Orion Link Desktop Suite, which enforces cryptographic signature verification. Optional Orion Connect cloud service provides remote instrument monitoring, automated backup, and role-based access control aligned with ISO/IEC 27001 data governance frameworks.

Applications

  • Regulatory BOD₅ testing for NPDES permit compliance and wastewater treatment plant discharge reporting (EPA 40 CFR Part 136).
  • Drinking water source monitoring per USP and pharmacopeial validation of purified water systems.
  • Environmental impact assessments requiring ISO 5815-1–compliant respirometry in river, lake, and estuarine sampling programs.
  • Industrial pretreatment verification for food processing, pharmaceutical, and pulp/paper facilities subject to local sewer authority limits.
  • Academic and research laboratories conducting microbial respiration kinetics, biodegradability screening (OECD 301 series), and ecotoxicity endpoint correlation studies.

FAQ

Does the 310D-24 perform actual 5-day BOD incubation, or is it a rapid estimation tool?

The 310D-24 does not incorporate an incubator; it is a precision measurement endpoint device. Users perform standard 5-day incubation in external BOD incubators (e.g., Thermo Scientific Forma Series), then measure DO depletion using the 310D-24’s calibrated sensor.

Can the instrument validate dilution water conductivity per Standard Methods 5210B?

Yes—the integrated conductivity module measures down to 0.001 µS/cm with NIST-traceable accuracy, satisfying the ≤2.0 µS/cm requirement for BOD dilution water.

Is the stirring function programmable or manually triggered?

Stirring is automatically engaged upon sensor immersion and maintained at a fixed, optimized speed (300 rpm nominal) to ensure hydrodynamic consistency per ASTM D888.

How is traceability ensured for audit purposes?

Each data record includes embedded digital signatures, timestamped calibration history, and immutable metadata—fully exportable with audit trail integrity verified against NIST SP 800-53 controls.

What electrode types are supported for BOD applications?

Standard configuration includes a Clark-type polarographic DO probe with integral stirrer; optional optical (luminescent) DO sensors are available for chloride-rich or sulfide-containing samples where electrochemical interference is a concern.