Brand York Instruments
Origin Germany
Manufacturer Type Manufacturer
Origin Category Imported
Model CPG2500
Price Upon Request
Internal Pressure Range 2.5 kPa to 290 MPa
External Pressure Range 2.5 kPa to 40 MPa
Sensor Configuration Three-channel (two internal, one external)
Accuracy Options 0.008 % IS-33 / 0.008 % IS-50 / 0.01 % IS-50 (k=2, total measurement uncertainty)
Uncertainty Components Intrinsic instrument performance, reference standard uncertainty, long-term stability, environmental influence (temperature, ambient pressure), zero-drift compensation range, thermal effects

Overview

The York Instruments CPG2500 High-Precision Pressure Display Instrument is a metrologically traceable, multi-channel digital pressure indicator engineered for primary and secondary calibration laboratories, national metrology institutes (NMIs), and high-integrity industrial process validation environments. It operates on the principle of high-stability analog-to-digital conversion of conditioned sensor signals, with real-time compensation for thermal drift, nonlinearity, and hysteresis—enabling direct comparison against primary standards such as deadweight testers or laser-interferometric pressure standards. Unlike conventional panel meters, the CPG2500 integrates dual internal pressure transducers and a configurable external sensor input, allowing simultaneous monitoring and cross-comparison across three independent pressure domains. Its architecture supports both gauge and absolute pressure measurements, with factory-traceable calibration certificates issued per ISO/IEC 17025 requirements. Designed for use in controlled laboratory settings and certified cleanrooms, the unit complies with EN 61326-1 (EMC for test and measurement equipment) and meets mechanical robustness criteria defined in IEC 60068-2 for vibration and shock resistance.

Key Features

  • Triple-sensor architecture: Two built-in high-stability piezoresistive or quartz-based pressure transducers plus one isolated external sensor port—enabling concurrent measurement, redundancy verification, and inter-channel differential analysis.
  • Ultra-high accuracy options: Configurable to 0.008 % of reading (IS-33 or IS-50 definition, k=2), validated across full span and sub-span ranges; uncertainty budget explicitly accounts for long-term stability (≤15 ppm/year typical), temperature coefficient (≤0.0005 %/°C), and zero-shift compensation efficacy.
  • Intelliscale™ adaptive scaling algorithm: Dynamically adjusts resolution and linearity correction based on actual operating pressure, maximizing effective digits across low- and high-pressure regimes without manual range switching.
  • Modular sensor interface: Supports hot-swappable, NIST-traceable pressure modules (e.g., CT25.021 series) with embedded EEPROM calibration data; automatic recognition and parameter loading upon insertion.
  • Front-panel zero suppression and span adjustment with audit trail logging—compliant with FDA 21 CFR Part 11 for electronic records and signatures when used with optional software configuration.

Sample Compatibility & Compliance

The CPG2500 accepts a broad spectrum of pressure media—including dry gases (N₂, Ar, He), inert liquids (silicone oil, mercury-free hydraulic fluids), and vacuum environments down to 10⁻³ mbar (when equipped with absolute sensors). It is compatible with all York Instruments-certified pressure modules rated for media compatibility per ASTM E2877-22 (guidance for pressure calibration systems) and ISO 5725-2 (accuracy and precision of measurement methods). All factory calibrations are performed under GLP-compliant conditions and documented with full uncertainty budgets per GUM (JCGM 100:2008). The instrument satisfies functional safety prerequisites outlined in IEC 61508 SIL 2 for use in safety-related process control loops when integrated with certified isolation barriers.

Software & Data Management

The CPG2500 interfaces via RS-232, USB-CDC, and optional Ethernet (TCP/IP) to York’s CalSoft Pro v4.x platform—a Windows-based application supporting automated calibration sequence execution, deviation reporting, and certificate generation per ISO/IEC 17025 Annex A3. Raw time-series data is exportable in CSV, XML, and HDF5 formats. Audit trail functionality records all user-initiated configuration changes, zero adjustments, and calibration events with timestamps, operator ID, and reason-for-change fields—fully compliant with ALCOA+ data integrity principles. Optional firmware upgrade path enables future integration with LIMS via OPC UA (IEC 62541) and supports digital signature workflows aligned with EU Annex 11 and USP .

Applications

  • Primary calibration of pressure transmitters, gauges, and digital manometers in accredited metrology labs.
  • In-process verification of high-pressure hydraulic systems in aerospace component testing (e.g., landing gear actuation, fuel system validation).
  • Reference-grade monitoring during creep and burst testing of composite pressure vessels per ASME BPVC Section VIII, Div. 3.
  • Traceable pressure referencing in pharmaceutical water-for-injection (WFI) distribution loop validation (USP , EU GMP Annex 15).
  • Cross-checking of deadweight tester outputs during periodic verification cycles—reducing downtime through parallel operation capability.

FAQ

What does “IS-33” accuracy mean, and how is it different from IS-50?
IS-33 denotes an accuracy specification where uncertainty is expressed as 0.008 % of reading above 33 % of full scale, and as 0.008 % of span below that threshold. IS-50 applies the same tolerance but shifts the breakpoint to 50 % of full scale—offering tighter relative uncertainty at mid-range pressures.
Can the CPG2500 be used with third-party pressure sensors?
Only York Instruments–certified, digitally encoded modules (e.g., CT25.021 series) are supported due to hardware-level encryption of calibration coefficients and thermal compensation parameters.
Is the unit suitable for hazardous area installations?
No—the CPG2500 is rated for general-purpose laboratory and control room use (IP20 enclosure); intrinsic safety requires external barrier integration and system-level certification.
How often does the unit require recalibration?
York Instruments recommends annual calibration against a higher-tier standard; however, stability data supports extended intervals up to 24 months in stable thermal environments when combined with quarterly in-house zero checks.
Does the device support absolute pressure simulation with zero-point drift compensation?
Yes—when configured with a factory-calibrated absolute pressure module, the CPG2500 performs active zero-point tracking and thermal zero-shift compensation, minimizing drift-induced errors over extended measurement sessions.