York Instruments
Filter
Showing all 12 results
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CPC4000 |
| Operating Principle | Electronic Pressure Control |
| Display | Digital |
| Control Stability | < 0.005 % FS |
| Control Speed | < 10 s |
| Accuracy | 0.02 % of reading (50–100 % FS), 0.02 % of half-scale (0–50 % FS) |
| Pressure Range | –0.1 to 21 MPa |
| Uncertainty Budget | Expanded uncertainty (k = 2) per ISO/IEC 17025, incorporating sensor intrinsic performance, reference standard uncertainty, long-term drift, thermal effects, zero-shift beyond auto-compensation range, and environmental influences |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPG 500 |
| Pricing | Available Upon Request |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPG2500 |
| Price | Upon Request |
| Internal Pressure Range | 2.5 kPa to 290 MPa |
| External Pressure Range | 2.5 kPa to 40 MPa |
| Sensor Configuration | Three-channel (two internal, one external) |
| Accuracy Options | 0.008 % IS-33 / 0.008 % IS-50 / 0.01 % IS-50 (k=2, total measurement uncertainty) |
| Uncertainty Components | Intrinsic instrument performance, reference standard uncertainty, long-term stability, environmental influence (temperature, ambient pressure), zero-drift compensation range, thermal effects |
| Brand | York Instruments |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CPH 6000 |
| Price | Upon Request |
| Pressure Range | 0–25 kPa to 0–600 MPa |
| Accuracy | ±0.025 % of reading (including accredited calibration certificate) |
| Sensor Interface | Hot-swappable internal/external pressure sensors with automatic range recognition |
| Cable Length for Remote Sensor | ~1 m |
| Operating Modes | Measurement, Calibration, Pressure Switch Test |
| Included Accessories | Dedicated calibration software, comprehensive maintenance kit (including hand pump) |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DM9200 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled Mirror Condensation |
| Operating Temperature Range | −30 to +90 °C |
| Accuracy | ±0.15 °C |
| Repeatability | ±0.05 °C |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Condensation |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C (dew point) |
| Repeatability | ±0.05 °C (dew point) |
| Display | High-Resolution Capacitive Touch LCD |
| User Interface | Graphical, Multilingual (English/Chinese), Step-by-Step Guidance |
| Mirror Control | Digital Fuzzy Logic with Auto-Balance Algorithm |
| Mirror Maintenance | Integrated Mirror Inspection and Automated Cleaning Sequence |
| Diagnostics | Real-Time Self-Diagnostic Engine with Fault Classification |
| Communication Interfaces | RS-485, USB 2.0 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | DM9600P |
| Measurement Principle | Chilled-mirror hygrometry |
| Display | 7-inch capacitive touchscreen LCD with bilingual (EN/CN) UI |
| Control System | Digital fuzzy logic control with auto-balance dew point stabilization algorithm |
| Communication Interfaces | RS-485, USB 2.0 |
| Data Storage | SD card slot (up to 32 GB, FAT32 formatted) |
| Compliance | Designed per ISO 8503-1 (surface profile), ASTM E104 (controlled humidity environments), and aligned with calibration traceability requirements of ISO/IEC 17025 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -20 °C to +40 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -70 °C to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for 10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (accuracy ±5%) |
| Pressure Sensor Range | 0–200 kPa (abs), accuracy ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, accuracy ±0.1 °C, cable length <2 m |
| Power Supply | 80–264 VAC, 47–63 Hz, 400 W |
| Analog Outputs | 4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V (3-channel, user-configurable) |
| Alarm Outputs | 2 programmable SPDT relays (250 VAC/5 A, 30 VDC/5 A, resistive load) |
| Communication | USB, RS-485, Modbus RTU protocol |
| Data Storage | SD card (FAT32, up to 32 GB) |
| Display | 7" LCD touch screen, 1024×600 RGB WVGA, 16:9 aspect ratio |
| Supported Units | °C, °F, ppmv, ppmw, %RH, g/kg, mg/m³ |
| Sample Gas Temp | -20 °C to +40 °C |
| Sample Gas Pressure | 0–200 kPa (abs) |
| Sample Flow Rate | 0.3–1 L/min |
| Environmental Humidity Limit | <80% RH |
| Storage Temperature | -20 °C to +50 °C (optimal at 20 °C) |
| Dimensions | 190 mm (H) × 483 mm (W) × 498 mm (D) |
| Weight | 15 kg |
| Gas Inlet Fitting | 1/4" stainless steel compression fitting |
| Enclosure Material | Aluminum alloy |
| Gas Path Materials | 316L stainless steel |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | 10–35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | −90 to +20 °C |
| Resolution | 0.01 °C |
| Response Time | ≤60 s (for ±10 °C step change) |
| Mirror Material | Chromium-Plated Copper |
| Flow Rate Range | 0–2 L/min (±5% FS) |
| Pressure Range | 0–200 kPa (abs), ±0.25% FS |
| Remote Temperature Sensor | 4-wire PT100, ±0.1 °C |
| Display | 9.7" LCD, 1024×768 RGB, 4:3 aspect ratio |
| Analog Outputs | 3-channel configurable (4–20 mA / 0–20 mA / 0–24 mA / 0–5 V / 0–10 V) |
| Digital Interfaces | USB, RS-485 (Modbus RTU) |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Enclosure | 6U 19″ rack-mountable aluminum chassis (278 × 483 × 578 mm, 40 kg) |
| Gas Inlet/Outlet | 1/4″ VCR (in), 1/4″ stainless steel compression (out) |
| Wetted Materials | 316L stainless steel, chromium-plated copper mirror |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Chilled-Mirror Hygrometry |
| Operating Temperature | -10 °C to +35 °C |
| Accuracy | ±0.1 °C |
| Repeatability | ±0.05 °C |
| Dew Point Range | -95 °C to +20 °C (at 20 °C ambient) |
| Display | 9.7" TFT LCD Touchscreen |
| Resolution | 0.01 °C |
| Output Options | 4–20 mA, 0–10 V, RS-485 (Modbus RTU), USB |
| Data Storage | SD Card (FAT32, up to 32 GB) |
| Sample Flow Rate | 0.3–1 L/min |
| Sample Pressure | 0–200 kPa (abs) |
| Sample Temperature | -20 °C to +40 °C |
| Mirror Material | Rhodium-plated Copper |
| Enclosure | Aluminum Alloy |
| Dimensions | 278 mm (H) × 483 mm (W) × 578 mm (D) |
| Weight | 40 kg |
| Power Supply | 198–254 VAC, 47–63 Hz, 1000 W |
| Brand | York Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Smart Pad |
| Instrument Type | Upright |
| Humidity Control Method | Dew Point Generation System |
| Temperature & Humidity Uniformity | High Precision (±0.3°C, ±1.5% RH typical) |
| Controller | Smart Pad — 60-Stage Programmable, Real-Time Display, Standard Alarm Outputs & RS-485 Communication |
| Brand | York Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | SS4-A2 |
| Pricing | Upon Request |
| Spectral Range | UV 185–260 nm, Visible 400–700 nm, IR 700–3500 nm |
| Detection Angle | 120° conical field of view |
| Sensitivity Options | 15 / 30 / 45 / 60 ft (1 ft² gasoline flame) |
| Response Time | 2–5 s at 60 ft |
| Operating Voltage | 24 VDC (20.5–34 VDC) |
| Relay Output | 1.0 A / 24 VAC |
| Operating Temperature | −40 °C to +85 °C |
| Humidity Range | 10–90% RH (non-condensing) |
| Hazardous Location Certification | Class I, Div 1 & 2, Groups B, C, D |