Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelTQ-01A
ApplicationPharmaceutical Dissolution Media Deaeration
DisplayHigh-Resolution Touchscreen LCD
Heating Range35–42 °C (adjustable to non-heating mode)
Volume Accuracy±1% (for set volumes ≥2 L)
Dispensing Resolution0.1 L
Flow Rate1.6 L/min
Dimensions (L×H×W)500 mm × 340 mm × 295 mm
Rated Power1700 W
Temperature Control Accuracy±2 °C
Residual Dissolved Oxygen3.0–5.0 mg/L (upgradable to <2.8 mg/L)
Minimum Inlet Medium Temperature≥18 °C
Pre-Filter Options40 µm / 25 µm / 20 µm Stainless Steel Mesh
Compatible MediaPurified water, distilled water (pH 1–14, surfactant-free)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601
Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Laser SourceDual-narrow-beam laser diode array (8th-generation)
Sensor Resolution1000 channels, down to 0.01 µm
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow regulation
Sample Volume Accuracy< ±1%
Counting Accuracy±3% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤2.5% at 1000 particles/mL
Channel FlexibilityUser-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c))
Flow Rate RangeSample: 5–150 mL/min
Rinse5–500 mL/min
Fluid Temperature Range0–80 °C
Ambient Operating Range−15–50 °C
ComplianceChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368
SoftwareV8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery)
Calibration StandardsNIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULL
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPull-GP4-1000
Capacity1 L
MaterialStainless Steel (AISI 316 or equivalent)
Design Pressure4 MPa
ComplianceGB 8570–2008 “Sampling of Laboratory Samples of Anhydrous Liquid Ammonia”
PricingUSD 450 (FOB China, subject to quotation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelPLD-269C
PricingAvailable Upon Request
Maximum Penetration Range75 mm
Penetration Resolution±0.1 mm
Timing Accuracy0.1 s
Standard ConeCompliant with GB/T 269
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of ManufactureChina
ModelPQ-2A
PriceUSD 64,500 (FOB China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601*
Sensor8th-generation dual-laser narrow-beam particle sensor
Detection PrincipleLight Blockage (Optical Obstruction)
Measurement Range1–500 µm (optional 0.03–3000 µm)
Channel Count1000 adjustable channels (down to 0.01 µm resolution)
Sampling Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Sample Temperature Range0–80 °C
Accuracy±3% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤2.5% at 1000 particles/mL
Resolution>95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated)
ComplianceChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015
SoftwareV8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection
InterfaceTouchscreen + optional wireless keyboard/mouse
Calibration StandardsJJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPLD-3535D
Temperature Range60 °C to −38 °C
Temperature Resolution0.1 °C
Sample Channels2
Cooling MethodAir-Cooled Compressor System
Detection MethodTop-Mounted Photoelectric Liquid-Level Sensor with Micro-Tilt Mechanism
Temperature Interval Setting1–10 °C (user-defined)
Power SupplyAC 220 V ±10%, 50 Hz ±2 Hz
Display128×64 Dot-Matrix LCD (Chinese Characters)
Printer20-Column Dot-Matrix Thermal Printer (Chinese Characters)
Compliance StandardGB/T 510