Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelTQ-01A
ApplicationPharmaceutical Dissolution Media Deaeration
DisplayHigh-Resolution Touchscreen LCD
Heating Range35–42 °C (adjustable to non-heating mode)
Volume Accuracy±1% (for set volumes ≥2 L)
Dispensing Resolution0.1 L
Flow Rate1.6 L/min
Dimensions (L×H×W)500 mm × 340 mm × 295 mm
Rated Power1700 W
Temperature Control Accuracy±2 °C
Residual Dissolved Oxygen3.0–5.0 mg/L (upgradable to <2.8 mg/L)
Minimum Inlet Medium Temperature≥18 °C
Pre-Filter Options40 µm / 25 µm / 20 µm Stainless Steel Mesh
Compatible MediaPurified water, distilled water (pH 1–14, surfactant-free)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601
Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Laser SourceDual-narrow-beam laser diode array (8th-generation)
Sensor Resolution1000 channels, down to 0.01 µm
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow regulation
Sample Volume Accuracy< ±1%
Counting Accuracy±3% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤2.5% at 1000 particles/mL
Channel FlexibilityUser-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c))
Flow Rate RangeSample: 5–150 mL/min
Rinse5–500 mL/min
Fluid Temperature Range0–80 °C
Ambient Operating Range−15–50 °C
ComplianceChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368
SoftwareV8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery)
Calibration StandardsNIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601*
Sensor8th-generation dual-laser narrow-beam particle sensor
Detection PrincipleLight Blockage (Optical Obstruction)
Measurement Range1–500 µm (optional 0.03–3000 µm)
Channel Count1000 adjustable channels (down to 0.01 µm resolution)
Sampling Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Sample Temperature Range0–80 °C
Accuracy±3% typical (per ChP 2020 & USP <788>)
Coincidence Limit≤2.5% at 1000 particles/mL
Resolution>95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated)
ComplianceChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015
SoftwareV8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection
InterfaceTouchscreen + optional wireless keyboard/mouse
Calibration StandardsJJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials