BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2
PriceUSD 72,800 (FOB)
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Sensor Generation8th-Generation Dual-Laser Optical Sensor
Flow ControlPrecision Plunger Pump + Electromagnetic Flow Regulation
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368
Measurement Range0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c)
Sampling Accuracy<±1%
Counting Accuracy±3% typical
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Output Interface4–20 mA analog output,超标 alarm relay (customizable)
Data OutputiPad-compatible wireless acquisition, touchscreen GUI + optional PC software (V8.3 Integrated Edition)
Power Supply100–265 VAC, 50–60 Hz
Compliance ArchitectureSeparated analytical testing & metrological calibration modules
Regulatory AlignmentSupports FDA 21 CFR Part 11 audit trail configuration (via optional software license), GLP/GMP-compliant reporting templates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2
Sensor Technology8th-Generation Dual-Laser Narrow-Beam Detection
Detection Range0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c))
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% at 1000 particles/mL
Calibration StandardsJJG 1061, ISO 21501-2, NIST-traceable latex spheres
Output4–20 mA analog interface with customizable alarm thresholds
Data ReportingParticles per mL & ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI)
ComplianceDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2CCS
Detection Threshold100 nm
Sensor Technology8th-Generation Dual-Laser Narrow-Beam Optical Sensor
Measurement Range0.1–0.5 µm (with customizable ranges: 1–100 µm or 4–70 µm(c), down to 0.1 µm(c))
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Calibration StandardsJJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres
Output Interface4–20 mA Analog Signal
Alarm FunctionConfigurable Particle Exceedance Alert
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for ISO 14644-1/2, SEMI F57, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows