Purification Equipment
Filter
Showing 931–960 of 1249 results
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SMART-R15U |
| Pricing | Available Upon Request |
| Purified Water Grade | ASTM Type I (Ultrapure) |
| Resistivity | ≥18.2 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | <10 ppb |
| Particles (>0.22 µm) | <1 particle/mL |
| Bacterial Count | <0.1 CFU/mL |
| Feed Water | Municipal tap water (5–40 °C, 1.0–1.5 bar) |
| Production Rate | 15 L/h |
| Primary Water Output | Conductivity <5 µS/cm @ 25 °C (ASTM Type III compliant) |
| Dimensions (Main Unit) | 423 × 445 × 280 mm (W × H × D) |
| Power Supply | 220 VAC, 100 W |
| Max Dispense Flow Rate | 2 L/min |
| Integrated Pressure Tank Options | 20 L (450 × 300 mm H × D) or 40 L (600 × 400 mm H × D) |
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Spring-S / Spring-R |
| Pure Water Grade | Type I (ASTM D1193-20) |
| Resistivity | ≥18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <15 ppb (UV-equipped models: <5 ppb) |
| Feed Water | Municipal tap water (5–40°C, pressure ≥0.1 MPa) |
| RO Configuration | Single-stage (S-series) or Dual-stage (R-series) |
| RO Recovery Rate | 30–60% (S), 20–30% (R) |
| Ion Removal Efficiency | 96–98% |
| Microbial & Particulate Removal (>0.22 µm) | >99% |
| Conductivity | <5 µS/cm |
| Max Flow Rate | ≥1.8 L/min |
| Quantitative Dispensing Range | 0.1–25 L (±2% accuracy) |
| Dimensions (W×H×D) | 423 × 445 × 280 mm |
| Power Supply | 220 V AC, 50–100 W |
| Certifications | NSF/ANSI Standard 58 & 61 compliant materials (NSF-certified wetted components) |
| Brand | RSJ |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | UNIQ |
| Quotation | Upon Request |
| Purified Water Grade | Type I (ASTM D1193-06 Grade I / GB/T 6682-2008 Grade I) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.01 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.2 µm) | <1 particle/mL |
| Integrated TOC Monitor Range | 1.0–999 ppb |
| Dual-Grade Dual-Quantitative Dispensing | Up to 2 L/min, ±1% volumetric accuracy |
| Storage Capacity | 25 L (modular expansion available) |
| Feed Water | Municipal tap water, 5–40 °C, 1–6 bar pressure |
| Disinfection | RO/UP circuit UV-LED + chemical-free thermal or ozone-compatible protocol |
| Power Input | AC 100–240 V, 50 Hz |
| Rated Power | 120 W |
| Dimensions (Reservoir Unit) | 280 × 490 × 555 mm (W×D×H) |
| (Main Unit w/ EZ-DSP Faucet) | 330 × 575 × 545 mm (W×D×H) |
| Brand | LabTech |
|---|---|
| Model | RWAI |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Sample Handling | Waste Liquid Monitoring and Overflow Prevention |
| Compatibility | Universal for Chromatography Systems and Sample Preparation Instruments |
| Pressure Equalization | Integrated Micro-Ventilation Port in Sealed Lid |
| Customization | OEM-Compatible Sealing Adapters and Drain Fittings for Existing Instrument Tubing |
| Container Support | 10 L, 20 L, and Other Standard Waste Carboys |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYPR00SIA1 |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYPR0LSIA1 |
| Pricing | Available Upon Request |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CYPR00S001 |
| Pricing | Available Upon Request |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ST-D12SY |
| Heating Method | Water Bath Heating |
| Sample Capacity | 12-position |
| Construction Material | Stainless Steel (304) |
| Temperature Control | PID Digital Controller with Dual LED Display, Timer Function, Over-Temperature Alarm & Dry-Run Protection |
| Gas Flow Control | Individual Adjustable Needle Valve per Channel |
| Sample Holder | Spring-Loaded Tube Clamps with Numbered Positions & Height-Adjustable Support Plate |
| Structural Design | Rotatable Circular Base for Easy Access to Water Bath |
| Safety Compliance | Compatible with Fume Hood Operation for Toxic Solvent Concentration |
| Gas Compatibility | Optimized for High-Purity Nitrogen (N₂) Delivery |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | INC-8A |
| Price Range | USD 14,000 – 28,000 |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient to 99 °C |
| Temperature Stability | ±0.1 °C |
| Sample Capacity | 0–32 positions (expandable from 8-base configuration) |
| Heating Power | 40 W |
| Gas Flow Control | Intelligent, position-independent pneumatic regulation |
| Tube Compatibility | Dedicated conical-bottom vials (specification-defined geometry) |
| Position Independence | Per-channel programmable gas flow, temperature, and endpoint volume |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | INC-8A+ |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | User-Programmable |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Volume Capacity per Vial | 0–40 mL |
| Maximum Channel Capacity | 32 (expandable from base 8-channel configuration) |
| Quantitative Target Range | 0.2–10 mL (including dry-down and near-dry endpoints) |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SPT-A |
| Heating Method | Water Bath |
| Temperature Range | 5–40 °C |
| Temperature Stability | ±1 °C |
| Tube Diameter Compatibility | 18 mm |
| Gas Flow Rate | 0–12 L/min |
| Sample Positions | 12 or 45 positions |
| Heating Power | 800 W |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | SPT-H |
| Price Range | USD 420 – 1,400 (FOB) |
| Heating Method | Water Bath |
| Temperature Stability | ±1 °C |
| Sample Tube Diameter Compatibility | 10–20 mm |
| Gas Flow Rate | 0–12 L/min |
| Sample Positions | 8 or 24 |
| Heating Power | 800 W |
| Control Interface | Touchscreen |
| Compatible with Conical Flasks | 50–100 mL |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium Mini |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <1 ppt |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Daily Output Capacity | Up to 10 L |
| Footprint Width | 28 cm (37 cm with optional mobile dispensing unit) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 DI |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Operating Weight | 23.6 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <4 ppb |
| Particulates | <1 particle/mL @ ≥0.2 µm |
| Microbial Content | <1 CFU/mL |
| Flow Rate | 1.7 L/min |
| Application Suitability | AA, IC, ICP, ICP-MS, HPLC |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 UF |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Weight (dry/operational) | 16.8 / 25.3 kg |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | <4 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles | <1 particle/mL @ ≥0.2 µm |
| Microbial count | <1 CFU/mL |
| Flow rate | 1.5 L/min |
| Filtration technology | Integrated ultrafiltration (UF) final polishing module |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 UV |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Weight (operational) | 24.8 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Particulates | <1 particle/mL @ ≥0.2 µm |
| Microbial Content | <1 CFU/mL |
| Flow Rate | 1.7 L/min |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® 611 VF |
| Dimensions (W×H×D) | 30.2 × 11.3 × 15.7 cm |
| Unit Weight | 17.4 kg |
| Operating Weight | 26.4 kg |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | <1 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles | <1 particle/mL @ ≥0.2 µm |
| Microbial Contamination | <1 CFU/mL |
| Flow Rate | 1.5 L/min |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® advance EDI |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Maximum Flow Rate | 10 L/h |
| Resistivity (at 25 °C) | 5–15 MΩ·cm |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 30 ppb |
| Particles (>0.1 µm) | < 1 particle/mL |
| Ion Removal Efficiency (EDI-based) | >99% for monovalent ions |
| Organic Removal (MW >300 Da) | >99% |
| Microbial Reduction | >99% (via integrated 0.22 µm final filter) |
| Storage | Integrated sealed bag-in-box reservoir (prevents ambient recontamination) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® Comfort I |
| Purified Water Grade | ASTM Type 3 |
| Ultrapure Water Grade | ASTM Type 1 |
| Resistivity | 18.2 MΩ·cm (at 25 °C) |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Count | < 1 CFU/1000 mL |
| Endotoxins | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate (Ultrapure) | up to 2 L/min |
| Flow Rate (Pure) | up to 3 L/min |
| Storage Tank Options | Bag-type, disposable, 42 L standard |
| Conductivity Monitoring | Inlet & outlet, temperature-compensated to 25 °C |
| UV Wavelengths | 185 nm & 254 nm |
| Final Filtration | Sartopore® 2 150 capsule filter (0.45 + 0.2 µm PES) |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Comfort II |
| Pure Water Grade | ASTM Type II |
| Ultrapure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 2 ppb |
| Microbial Contamination | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Technology | Electrodeionization (EDI) + Dual-Stage Filtration + Integrated UV (185/254 nm, optional) |
| Storage | Sealed, single-use Arium® Bag Tank |
| Compliance | Meets ASTM D1193, ISO 3696, CLSI EP21-A, and supports GLP/GMP data integrity requirements |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | Arium® Mini Extend |
| Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <1 ppt |
| Total Organic Carbon (TOC) | ≤5 ppb |
| Microbial Count | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Daily Output Capacity | Up to 10 L |
| Footprint | 28 cm width (base unit) |
| Display | Full-color capacitive touchscreen interface |
| Feedwater Compatibility | Pre-treated water (e.g., reverse osmosis or deionized feed) |
| Technology | Integrated Bagtank™ disposable reservoir system |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® Pro Basic |
| Purified Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | < 0.1 ppm |
| Total Organic Carbon (TOC) | < 1000 ppb (feed water) / < 20 ppb (product water) |
| Particles (> 0.2 µm) | < 1 per mL |
| Bacteria | < 1 CFU/1000 mL |
| Feed Water Requirements | DI, RO, or EDI with conductivity ≤ 100 µS/cm, TOC ≤ 1000 ppb, turbidity < 1 NTU, silica < 1000 ppb, minimum inlet pressure 6.9 bar |
| Max. Flow Rate | 2 L/min at 2 bar |
| Dimensions (W×D×H) | 350 × 451 × 492 mm |
| Weight (empty/fully loaded) | 17 kg / 27 kg |
| Power Supply | 100–240 V AC, 50–60 Hz, max. 130 VA |
| Interfaces | RS232 (printer), touchscreen GUI with real-time monitoring and service alerts |
| Compliance | Meets or exceeds ASTM D1193-23, ISO 3696:1987, USP <1231>, CLSI EP21-A |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | arium® pro |
| Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppm |
| Total Organic Carbon (TOC) | ≤2 ppb |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1/mL |
| Microbial Count | <1 CFU/1000 mL |
| UV Lamps | Dual-wavelength (185 nm & 254 nm) |
| Ultrafiltration Module | 5 kDa MWCO |
| Final Filtration | Sartopore® 2 150, 0.45 + 0.2 µm PES |
| Conductivity Monitoring | Inlet & Outlet |
| Data Storage | SD card, RS-232, optional printer interface |
| User Interface | Touchscreen glass panel with PIN-protected configuration |
| Flow Rate | Adjustable 0.1–2.0 L/min (manual), programmable quantitative/timed dispensing |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000 |
| Instrument Type | Sub-boiling Distiller |
| Cooling Method | Passive (Air) Cooling |
| Distillation Endpoint Control | Automatic |
| Power Supply | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excluding funnel) |
| Capacity | 125 mL – 1 L |
| Wetted Materials | Molded PFA Only |
| Compliance | ASTM D511, ISO 17294-2, USP <645>, FDA 21 CFR Part 11 (software-enabled audit trail optional) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000 |
| Power Input | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excl. funnel) |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA |
| Cooling | Air-cooled (no water required) |
| Drainage | Integrated gravity-fed drain channel |
| Temperature Control | Adjustable, sub-boiling range |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000A |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Resistive Heating (Corrosion-Resistant Heater Sleeve) |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 1000 mL/24 h |
| Warm-up Time | 30 min |
| Endpoint Control | Manual |
| Heating Element | Corrosion-Resistant PFA-Encapsulated Heater Sleeve |
| Power Input | 70 W |
| Voltage Options | 100/115/230 VAC ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 20 × 20 × 43 cm (excl. funnel) |
| Weight | 4.6 kg |
| Maximum Capacity | 1 L |
| Material of Wetted Parts | Injection-Molded PFA |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000B |
| Power Input | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15" × 10.15" × 16.92") |
| Height with Funnel | 51 cm (20.08") |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA Fluoropolymer |
| Cooling | Air-cooled (no water required) |
| Temperature Control | Adjustable, sub-boiling range |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-1000N |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Silicone Rubber Heating Mantle |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | Up to 500 mL per 12 hours |
| Warm-up Time | 30 minutes |
| Endpoint Control | Temperature-based Setpoint Activation |
| Heating Element | Silicone Rubber Heating Mantle |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-4000 |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Resistive Heating (Corrosion-Resistant Heater Sleeve) |
| Cooling Method | Passive Air Cooling |
| Endpoint Control | Automatic |
| Heating Element | PFA-Encapsulated Resistive Heater in Corrosion-Resistant Protective Sleeve |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (excluding funnel) |
| Weight | 4.6 kg |
| Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA (Perfluoroalkoxy Alkane) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | DST-4000S |
| Instrument Type | Sub-boiling Distiller |
| Heating Method | Encircling Electric Heating Mantle |
| Cooling Method | Natural Air Cooling |
| Distillation Rate | 500 mL/24 h |
| Warm-up Time | 60 min |
| Endpoint Control | Max. 4 L total distillate volume |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15″ × 10.15″ × 16.92″) |
| Reservoir Capacity | 125 mL – 1 L |
| Material of Wetted Parts | Molded PFA |