Empowering Scientific Discovery

Pye Unwin Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelLiberty PRO
PricingUpon Request
Amino Acid DeliveryAutomated
Reagent DeliveryAutomated
Synthesis Scale15–1000 mmol
Reactor Count3
Reactor Volume Options3 L, 8 L, 15 L (max. 15 L capacity)
Crude Peptide Yield per BatchUp to 1 kg
Synthesis Purity≥99%
Temperature ControlNIST-Traceable Internal Sensor
Stirring ModesMechanical Agitation + N₂ Sparging
Regulatory CompliancecGMP-Compliant Materials & Architecture
Key Patented TechnologiesCarboMAX™ Coupling, HE-SPPS (High-Efficiency Solid-Phase Peptide Synthesis), No-Wash Deprotection/Coupling
Core PatentsUS7393920
Software ComplianceFDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Role-Based Access Control
Validation DocumentationFAT, IQ/OQ, FDS/SDS, Leachables & Extractables Reports, ATEX Hazard Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
ModelDISCOVER SPS
Reaction ModeSingle-Mode Microwave
Max. Reaction Volume300 mL
Sample Throughput14 samples per run
Temperature Range0–300 °C
Typical Enzymolysis Temperature55 °C
Temperature Accuracy±1 °C
Temperature SensingIn-situ Fiber-Optic Probe
MixingMagnetic Stirring
Cooling5 PSI Forced Air
Sample Vial Format1.5 mL Microcentrifuge Tubes
Minimum Sample Volume30 µL
Hydrolysis Time (Typical)10–15 min
Enzyme-to-Protein Ratio Range1:100 to 1:10
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelMultiPep 1 (SLi) / MultiPep 2 (RSi)
Amino Acid DeliveryAutomated
Reagent DeliveryAutomated
User AuthenticationPassword + Facial Recognition
Audit TrailYes
Synthesis Scale0.001–0.3 mmol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelCleavagePro
Amino Acid AdditionAutomated
Reagent AdditionAutomated
Synthesis Scale1–10 μmol
Reaction Vessel Count48
Reaction Vessel Capacity Options15 mL / 50 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelInsituPro Vsi
Instrument TypeIn Situ Hybridization System
Temperature Range6–75 °C (Basket Mode), 10–70 °C (Slide Mode)
Buffer Volumes2×1000 mL, 3×50 mL, 6×125 mL, 7×50 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelLiberty Prime 2.0
QuotationUpon Request
Amino Acid DeliveryAutomated
Reagent DeliveryAutomated
Synthesis Scale0.0005–5 mmol
Number of Reactors3
Reactor Volume Range10–125 mL
Syringe Pump Accuracy±0.01 mL
Crude Peptide Purity>70%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
ModelLibertyBlue 2.0
Amino Acid DeliveryAutomated
Reagent DeliveryAutomated
User AuthenticationPassword + Facial Recognition
Audit TrailYes
Synthesis Scale0.005–5 mmol
Reactor Count4
Reactor Volume Range10–125 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
ModelLiberty Lite 2.0
Amino Acid AdditionAutomated
Reagent AdditionAutomated
Synthesis Scale0.005–5 mmol
Reactor Count4
Reactor Volume Range10–125 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelRAZOR
Amino Acid AdditionAutomated
Reagent AdditionAutomated
Operator AuthenticationPassword + Facial Recognition
Audit TrailYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCEM
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelDiscover Hydrolysis
QuotationUpon Request
Reaction MethodSingle-Mode Microwave
Reaction Time10 minutes
Sample Volume per Vial300 µL (up to 10 vials)
Temperature Control Range0–300 °C
Hydrolysis Scale1 pmol – 1 fmol
Vial FormatHPLC-compatible glass autosampler vials (100–300 µL)
Temperature SensorIn-situ fiber-optic probe (RT–300 °C)
Vacuum Level25 mmHg
Stirring MechanismMagnetic stirring
Atmosphere ControlAlternating vacuum/N₂ purging via integrated valve panel
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0