- All
- Favorite
- Popular
- Most rated
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | HG-600 Geno/Grinder |
| Power | 245 W |
| Operating Frequency Range | 8–30 Hz |
| Vertical Stroke Amplitude | 8–30 mm |
| Max. Sample Capacity | 576 samples (e.g., 6 × 96-well plates) |
| Dimensions (W×L×H) | 38 cm × 52 cm × 64 cm |
| Weight | 39.5 kg |
| Safety Certification | CE |
| Voltage/Frequency | AC 230 V, 50 Hz |
| Timer Range | 0–20 min (LCD display in mm:ss format) |
| Clamp Height Limit | ≤57 mm (2.25 in) |
| Motor Rating | 1/3 HP |
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | CG-200 Freezer/Mill |
| Instrument Type | Cryogenic Grinder |
| Sample Compatibility | Frozen & Temperature-Sensitive Materials |
| Output Particle Size | < 0.01 mm |
| Input Sample Size | ≤ 3 cm |
| Batch Capacity | 0.1–10 g |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Precooling Time | 4.5 min to −196 °C |
| Grinding Time | Adjustable, typically 2 min |
| Chamber Volume | 20 mL (standard) |
| Precooling Chamber Volume | 100 mL |
| Power | 225 W |
| Voltage | 230 V / 50 Hz |
| Frequency Range | 5–15 Hz |
| Dimensions | 48 × 27 × 32 cm |
| Weight | 11.8 kg |
| Certifications | CE, RoHS, WEEE compliant |
| Data Interface | USB port for program upload/download and diagnostics |
| Stored Methods | Up to 20 user-defined protocols |
| Safety Features | LN₂ level sensor with auto-shutdown, interlocked lid, coil overheat protection |
| Brand | SSI |
|---|---|
| Origin | USA |
| Model | ReaXus Series |
| Flow Rate | 0.1–300 mL/min |
| Maximum Pressure | 10–25,000 psi |
| Fluid Path Materials | Stainless Steel, PEEK, Hastelloy C-276 (model-dependent) |
| Drive Type | Positive Displacement with Eccentric Cam or Servo-Motor Actuation |
| Control Interface | Front-panel keypad, RS-232, USB |
| Compliance | Designed for GLP/GMP environments |
| Maintenance | Zero calibration requirement |
| Brand | PYNN |
|---|---|
| Origin | USA |
| Model | EVAPT 5 |
| Instrument Type | Vacuum-Free Centrifugal Concentrator |
| Key Patents | US 8,061,056 B2 (Self-Generated Blow-Down Technology) |
| Operating Temperature Range | 0–55 °C |
| Timer Range | 0–1000 min |
| Dimensions | 20.3 cm × 30.5 cm × 45.7 cm (W×D×H) |
| Sample Capacity Options | 6×20 mL scintillation vials |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 7 |
| Chamber Class | Industrial-Grade |
| Batch Capacity | 40 samples |
| Microwave Source | Dual Magnetron |
| Max Temperature | 350 °C |
| Temp Measurement Accuracy | ±0.1 °C |
| Temp Control Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 3000 psi |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Clean-STAR |
| Chamber Class | Industrial-Grade |
| Sample Capacity | 2–6 positions |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 500 °C |
| Operating Pressure | Ambient (Atmospheric) |
| Vessel Options | PTFE (30 mL, 70 mL), Quartz (100 mL) |
| Software | STAR LINK™ PC Interface, 20 Predefined Methods, Real-Time Temp/Time Curve Visualization, Endpoint Detection via Moisture/Volatility Sensing, Integrated Gas Absorption Module |
| Safety | Automated Interlock, Overtemperature & Overpressure Monitoring, HEPA-Filtered Inert Gas Purge (N₂ or Clean Air) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Voyager (Single-Mode) |
| Temperature Range | −80 °C to 300 °C |
| Pressure Range | 0–500 psi with intelligent pressure-triggered microwave cutoff |
| Microwave Power | 900 W |
| Reaction Volume | 300 mL |
| Flow Cell Capacity | 80 mL glass vessel |
| Pump Type | Peristaltic pump |
| Temperature Sensing | Fiber-optic or IR-based real-time monitoring |
| Pressure Sensing | Direct inline transducer |
| Valve Configuration | Dual valves (4-position and 6-position options) |
| Reagent Sensors | Two integrated reagent presence detectors |
| Operating Limits | Up to 220 °C or 200 psi continuous operation |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | DISCOVER 2.0 |
| Temperature Range | Up to 200 °C |
| Pressure Range | Up to 200 psi (13.8 bar) |
| Microwave Power | 900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Electromagnetic Stirring |
| Reaction Vessel Capacity | 10 mL |
| Gas Compatibility | H₂, O₂, CO₂, CO, N₂, Ar (non-corrosive only) |
| Temperature Monitoring | Fiber-Optic Probe |
| Pressure Monitoring & Control | Real-time digital pressure sensor with vacuum purge and vent capability |
| Gas Dosing | Programmable mass-flow-controlled gas introduction |
| System Integration | Fully compatible with CEM DISCOVER modular platform |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Discover 2.0 (Single-Mode) |
| Temperature Range | 0–300 °C |
| Pressure Range | 0–35 bar (500 psi) |
| Microwave Power Output | 0–900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Modes | Electromagnetic + Optional Mechanical Stirring |
| Reaction Volume Capacity | 300 mL |
| Cavity Type | Ring-Focused Single-Mode |
| Cooling Technology | PowerMAX Synchronized Active Cooling |
| Control Interface | 10.1" Touchscreen with TimeWave Embedded OS |
| Camera Integration | 5 MP Real-Time Imaging Module |
| Compliance | ISO 9001, CE, ETL, FDA 21 CFR Part 11 Ready (via Synergy PC Software) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | ETC |
| Cleaning Agents | HNO₃, HCl, HF, H₂SO₄ |
| External Dimensions | Ø330 mm × 400 mm (H) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DISCOVER SP-D |
| Price | Upon Request |
| Cavity Class | Industrial-Grade |
| Sample Capacity | Automated 48/72/96-Position |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 300 °C |
| Max Pressure | 27 bar |
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | BM-400/450 |
| Instrument Type | High-Energy Ball Mill |
| Sample Compatibility | Hard and brittle materials |
| Feed Size | <20 mm |
| Final Particle Size | <5 nm |
| Batch Capacity | 0.1–10 g per vial |
| Motion Type | Patented ∞-shaped 3D eccentric oscillation |
| Vial Displacement | ±59 mm (front-rear), ±25 mm (left-right) |
| Oscillation Frequency | 1060 cycles/min |
| Motor Speed | 1725 rpm |
| Cooling | Integrated forced-air cooling for clamp and motor housing |
| Control Interface | Programmable LCD touchscreen with time-based automation (up to 10,000 min) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORACLE |
| Quotation | Upon Request |
| Extraction Chamber Volume | 10 mL |
| Receiving Bottle Volume | 110 mL |
| Temperature Range | Ambient |
| Temperature Control Accuracy | ±1°C |
| Number of Channels | 1 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Instrument Type | Single-Mode Microwave Reactor |
| Temperature Range | –80 °C to 300 °C |
| Pressure Range | 0–35 bar |
| Microwave Power Output | 0–600 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Modes | Electromagnetic + Mechanical Stirring |
| Reaction Vessel Capacity | 300 mL |
| Brand | ThalesNano |
|---|---|
| Origin | Hungary |
| Model | PhotoCube |
| Temperature Range | 20–80 °C |
| Reaction Mode | Batch & Flow |
| Batch Volumes | 4 mL & 25 mL (glass) |
| Flow Loop Volume | 5–25 mL |
| Loop Material Options | FEP or PFA |
| Wavelengths | 365, 395, 457, 500, 523, 595, 623 nm + White LED |
| Max LED Power per Channel | 128 W |
| User-Configurable Parameters | Wavelength Selection, Irradiance Intensity, Stirring Speed, Temperature Setpoint & Feedback Control |
| Safety Features | Interlocked Light Shielding, UV/Visible Radiation Containment |
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | XP-400 (formerly 3636) |
| Type | Fully Automated Hydraulic Pellet Press |
| Application | Analytical Pellet Preparation for XRF and FTIR |
| Cycle Time | ≤60 s per pellet |
| Max Platen Width | 80 mm |
| Adjustable Stroke Range | 50–150 mm |
| Nominal Clamping Force | 40 tons (357 kN) |
| Operation Mode | Vertical (Top-Bottom) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | MARS 6 |
| Batch Capacity | 0–40 samples |
| Microwave Source | Single or Dual Magnetron |
| Max Temperature | 260 °C / 330 °C |
| Temp Accuracy | ±0.1 °C |
| Temp Stability | ±0.1 °C |
| Temp Uniformity | ±0.1 °C |
| Max Pressure | 500 psi / 2200 psi |
| Cavity Volume | 66 L |
| Microwave Output Power | 1800 W (IEC 705:1988) |
| Operating Voltage | 220 VAC, 50 Hz, 15 A |
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | CG-500 |
| Instrument Type | Cryogenic Grinder |
| Sample Applicability | Frozen & Temperature-Sensitive Materials |
| Final Particle Size | <0.01 mm |
| Maximum Feed Size | <5 cm |
| Batch Capacity | 0.1–200 g |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Precooling Time | 4.5 min to −196 °C |
| Grinding Time | Adjustable, typically 2 min |
| Electromagnetic Impact Frequency | 5–15 Hz |
| Power | 700 W |
| Voltage | 230 V / 50 Hz |
| Dimensions | 50.8 × 53.34 × 64.77 cm |
| Weight | 35 kg |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFC-24 |
| Price | Upon Request |
| Flow Rate | 0.01–24.0 mL/min |
| Maximum Pressure | 10,000 psi |
| Pressure Accuracy | ±2% of full scale |
| Flow Accuracy | ±5% (gas-volume-based liquid flow calculation) |
| Cooling System | Integrated Peltier module |
| Fluid Path Material | Stainless steel (except aluminum pump head) |
| Pressure Sensor | Built-in electronic transducer |
| Control Interface | Front-panel keypad with LED display, RS-232 serial port, TTL start/stop input, 0–10 V analog flow setpoint, 0–10 kHz frequency-based flow control |
| Constant-Pressure Mode | User-selectable pressure setpoint with automatic flow modulation |
| Dimensions | 14.6 × 28.3 × 53.7 cm (H × W × D) |
| Weight | 16.3 kg |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Explorer (Single-Mode) |
| Temperature Range | 0–350 °C |
| Pressure Range | 0–500 psi |
| Microwave Power | 900 W |
| Magnetron Frequency | 2450 MHz |
| Stirring Method | Electromagnetic |
| Reaction Vessel Volume | 300 mL |
| Cavity Type | Circular Single-Mode |
| Real-Time Pressure Monitoring | 0–35 bar |
| Low-Temperature Capability | Down to –80 °C |
| Automation | XYZ Robotic Arm with 12/24/48-Position Auto-Sampler |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EDGE |
| Instrument Type | Liquid–Solid Extraction |
| Temperature Range | 100–200 °C |
| Pressure Range | 13.8 MPa |
| Extraction Cell Volumes | 11 / 22 / 34 / 66 mL |
| Extraction Time | 5 min per sample |
| Instrument Dimensions | 360 mm (W) |
| Sample Capacity | 24 positions (dual rack, 12 per run) |
| Brand | Teledyne ISCO |
|---|---|
| Origin | USA |
| Model | X-Series (e.g., 1000X, 500X, 500XV, 260X, 65X) |
| Flow Rate | 0.00001–408 mL/min |
| Maximum Pressure | 30,000 psi (2,068 bar) |
| Flow Accuracy | ±0.3–0.5% of setpoint |
| Pressure Accuracy | ±0.1–0.5% of full scale |
| Drive Resolution | 2.5–63.4 nL per step |
| Operating Temperature | 5–40 °C (optional high-temp up to 200 °C) |
| Wetted Materials | Nitronic 50, PTFE, Hastelloy C-276 |
| Communication Interfaces | RS-232, analog I/O, dry-contact DCS, LabVIEW-compatible |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | PHOENIX Black |
| Instrument Type | Box-Type Microwave Muffle Furnace |
| Max Temperature | 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power Output | 1950 W |
| Ramp Time to Max Temperature | 10 min |
| Heating Method | Microwave |
| Internal Chamber Dimensions | 24.6 × 16.7 × 10.1 cm |
| Chamber Volume | 1.8 L (standard) / 5 L (optional) |
| Airflow Capacity | 100 CFM (standard), up to 130 CFM (with optional Airwave Amplifier) |
| Crucible Cooling Time | <30 s (1200 °C → ambient) |
| Brand | SPEX SamplePrep |
|---|---|
| Origin | USA |
| Model | BM-450 |
| Instrument Type | High-Energy Ball Mill |
| Sample Suitability | Hard & Brittle Materials |
| Feed Size | <30 mm |
| Final Particle Size | <5 nm |
| Batch Capacity | 2 jars per run |
| Operating Speed | 1725 rpm |
| Motion Type | Patented 3D Figure-Eight Oscillation |
| Clamp Stroke | ±59 mm (front-back), ±25 mm (left-right) |
| Clamp Frequency | 1060 cycles/min |
| Cooling | Integrated Air-Cooling System for Clamp Assembly |
| Control Interface | Programmable LCD Touch Panel |
| Max Program Duration | 10000 minutes |
| Grinding Jar Design | Seamless Arc-Profile Interior (No Dead Zones) |
Show next