- All
- Favorite
- Popular
- Most rated
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy 2.0 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 4–250 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 300 bar |
| Wavelength Range | 190–500 nm |
| Wavelength Repeatability | ±3 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash EZ Prep |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–200 mL/min |
| Flow Rate Precision | RSD ≤ 1% |
| Maximum Operating Pressure | 3500 psi (240 bar) |
| Wavelength Range | 200–400 nm (UV), 200–800 nm (UV-VIS) |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 200 Hz |
| Column Compatibility | Up to 50 mm ID, down to 5 µm particle size packing |
| Solvent Switching | Fully Automated, User-Initiated or Method-Triggered (Normal-Phase to Reversed-Phase) |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash NextGen |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | RSD ≤ 0.01% |
| Flow Precision | RSD ≤ 0.1% |
| Maximum Operating Pressure | 300 psi (20 bar) |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Options | UV, UV-Vis, ELSD, Mass Spectrometry (MS)-compatible interface |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash Torrent |
| Application Level | Industrial-Scale Preparation |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1 L/min |
| Flow Accuracy | <1% |
| Flow RSD | <1% |
| Maximum Operating Pressure | 100 psi |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Sample Capacity | Up to 600 g per run |
| Column Compatibility | RediSep® (80 g – 3 kg), glass columns, third-party cartridges |
| Software | PeakTrak™ v5.0 with real-time gradient editing, method scaling, and RFID-enabled column recognition |
| Detection | Dual-wavelength UV/Vis detector with auto-zero baseline correction |
| Fraction Collection | Foxy R2 fraction collector or motorized 6-port switching valve |
| Safety Systems | Integrated pressure transducer, solvent vapor sensor, automatic shutdown on fault |
| Fluidic Architecture | Fully grounded stainless-steel and PEEK tubing, large-bore flow path |
| Brand | Teledyne ISCO |
|---|---|
| Origin | USA |
| Model | AccQ Prep HP150 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–150 mL/min (pump head not required for range adjustment) |
| Flow Accuracy | RSD < 0.05% |
| Flow Precision | RSD ≤ 1% |
| Maximum Operating Pressure | 6000 psi |
| Wavelength Range | 1 nm resolution |
| Wavelength Repeatability | ±1 nm |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 200 Hz |
| Detector Options | UV (200–400 nm), UV-Vis (200–800 nm), ELSD, MS interface (optional) |
| Integrated Touchscreen Control | Yes |
| RFID-enabled Fraction Collection | Yes |
| Solvent & Waste Level Monitoring | Yes |
| Auto-sampler Module | Optional (supports unattended operation, multi-injection, column switching across 4 columns) |
Show next