Empowering Scientific Discovery

Pye Unwin Limited

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERASPEC
PortabilityPortable
Detection PrincipleMid-Infrared Spectroscopy
Measurement Range (Octane Number)70–105
Accuracy±0.1 ON
Analysis Time60 seconds
Sample Volume10 mL
ComplianceGB/T 33648–2017 (Illicit Additives), ASTM D6227 (Benzene), ASTM D5845 (Oxygenates)
Spectral Range631–45,890 cm⁻¹
Spectral Resolution2 cm⁻¹
Wavenumber Accuracy< 0.01 cm⁻¹
Signal-to-Noise Ratio> 10,000:1
Built-in Density Measurement±0.0001 g/cm³
Data Storage Capacity~6,000 results
Interface Options5× USB, 1× Ethernet, 1× RS232, LIMS-ready
Power Supply85–264 VAC / 47–63 Hz / 70 W or 12 VDC / 8 A (vehicle power)
Dimensions290 × 350 × 340 mm
Weight9.7 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginImported
ModelERASPEC DIESEL
Measurement PrincipleMid-IR Fourier Transform Infrared (FTIR) Spectroscopy
Measurement ItemsCetane Number (CN), Cetane Index (CI), Fatty Acid Methyl Esters (FAME), Total Aromatics, Polycyclic Aromatic Hydrocarbons (PAH), Distillation Temperatures (T85, T90, T95), Cetane Improvers, Biodiesel Content, Fatty Acid Ethyl Esters (FAEE), Rapeseed Oil, Dimethoxymethane (DMM), etc.
Sample Volume10 mL
Analysis Time≤ 60 s
PortabilityFully Portable (Lab & Field-Deployable)
Spectral Range631–45890 cm⁻¹
Spectral Resolution2 cm⁻¹ (data acquisition at 0.5 cm⁻¹)
Wavelength Accuracy< 0.01 cm⁻¹
Signal-to-Noise Ratio> 10,000:1
Density Measurement Accuracy±0.0001 g/cm³
Data Storage Capacity~6,000 results
Power Supply85–264 VAC, 47–63 Hz, 70 W
DC Input12 V / 8 A (vehicle-compatible)
Dimensions290 × 350 × 340 mm
Weight9.7 kg
ComplianceGB/T 33648–2017 (detection of illegal diesel additives), EN 14078, GB 23801
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERALYTICS
OriginAustria
ModelERASPEC JET
ApplicationGasoline Octane Number and Diesel Cetane Number Analysis
PortabilityPortable
Measurement PrincipleFourier Transform Infrared (FTIR) Spectroscopy
Measurement Range0–170 (Octane/Cetane Scale)
Accuracy±0.01
Measurement Time60 s
Sample Volume10 mL
Spectral Range4000–400 cm⁻¹
Data PointsUp to 3000 per spectrum
Density Measurement Accuracy±0.0001 g/cm³ (integrated Anton Paar density module)
Dimensions220 × 320 × 280 mm
Weight8 kg
Power Supply85–263 VAC, 47–63 Hz, 70 W
DC Input12 V / 4 A (vehicle-compatible)
Storage Capacity≥2000 test records
Interfaces3× USB, 1× Ethernet, 1× RS232, LIMS-ready
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0