- All
- Favorite
- Popular
- Most rated
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range (Octane Number) | 70–105 |
| Accuracy | ±0.1 ON |
| Analysis Time | 60 seconds |
| Sample Volume | 10 mL |
| Compliance | GB/T 33648–2017 (Illicit Additives), ASTM D6227 (Benzene), ASTM D5845 (Oxygenates) |
| Spectral Range | 631–45,890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Built-in Density Measurement | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Interface Options | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Power Supply | 85–264 VAC / 47–63 Hz / 70 W or 12 VDC / 8 A (vehicle power) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Brand | ERALYTICS |
|---|---|
| Origin | Imported |
| Model | ERASPEC DIESEL |
| Measurement Principle | Mid-IR Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Items | Cetane Number (CN), Cetane Index (CI), Fatty Acid Methyl Esters (FAME), Total Aromatics, Polycyclic Aromatic Hydrocarbons (PAH), Distillation Temperatures (T85, T90, T95), Cetane Improvers, Biodiesel Content, Fatty Acid Ethyl Esters (FAEE), Rapeseed Oil, Dimethoxymethane (DMM), etc. |
| Sample Volume | 10 mL |
| Analysis Time | ≤ 60 s |
| Portability | Fully Portable (Lab & Field-Deployable) |
| Spectral Range | 631–45890 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ (data acquisition at 0.5 cm⁻¹) |
| Wavelength Accuracy | < 0.01 cm⁻¹ |
| Signal-to-Noise Ratio | > 10,000:1 |
| Density Measurement Accuracy | ±0.0001 g/cm³ |
| Data Storage Capacity | ~6,000 results |
| Power Supply | 85–264 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 8 A (vehicle-compatible) |
| Dimensions | 290 × 350 × 340 mm |
| Weight | 9.7 kg |
| Compliance | GB/T 33648–2017 (detection of illegal diesel additives), EN 14078, GB 23801 |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC JET |
| Application | Gasoline Octane Number and Diesel Cetane Number Analysis |
| Portability | Portable |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Measurement Range | 0–170 (Octane/Cetane Scale) |
| Accuracy | ±0.01 |
| Measurement Time | 60 s |
| Sample Volume | 10 mL |
| Spectral Range | 4000–400 cm⁻¹ |
| Data Points | Up to 3000 per spectrum |
| Density Measurement Accuracy | ±0.0001 g/cm³ (integrated Anton Paar density module) |
| Dimensions | 220 × 320 × 280 mm |
| Weight | 8 kg |
| Power Supply | 85–263 VAC, 47–63 Hz, 70 W |
| DC Input | 12 V / 4 A (vehicle-compatible) |
| Storage Capacity | ≥2000 test records |
| Interfaces | 3× USB, 1× Ethernet, 1× RS232, LIMS-ready |
Show next