- All
- Favorite
- Popular
- Most rated
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Ailun 6080 |
| Price | USD 118,000 (FOB Qingdao) |
| Detection Principle | Passive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs) |
| Instrument Type | Portable |
| Typical Configuration | Dual-Mode VOC Imaging & Precision Thermography System |
| Thermal Sensitivity (NETD) | ≤0.01 °C @ 30 °C |
| Volumetric Leak Detection Sensitivity | ≤0.001 mL/s (for methane, propane, and common C1–C4 hydrocarbons under ISO 16000-22–compliant field conditions) |
| Detector Type | Cooled Type-II Strained-Layer Superlattice (T2SL) focal plane array |
| Weight | 2.4 kg |
| Explosion Protection Rating | Ex ic nC op is IIC T6 Gc (IEC 60079-0, -7, -11, -15, -31) |
| Data Storage | Internal SD card (up to 512 GB, FAT32 formatted), supports JPEG thermal images, radiometric MP4 video, and CSV metadata export |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DM-600(III) |
| Instrument Type | Portable |
| Principle | Infrared Spectrophotometry (Fourier-transform-free dispersive IR) |
| Measurement Range | 0.00–64,000 mg/L |
| Detection Limit | 0.0012 mg/L (as oil in water) |
| Accuracy | ±2% of reading |
| Spectral Resolution | 1 cm⁻¹ |
| Analysis Time per Sample | ≤60 s |
| Wavenumber Accuracy | ±1 cm⁻¹ |
| Absorbance Range | 0.00000–2.00000 AU |
| Wavenumber Range | 2400–3400 cm⁻¹ |
| Operating Temperature | −5 to 50 °C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Supply | Internal Li-ion battery (≥8 h continuous operation) or 12 V DC automotive input |
| Compatible Extraction Solvents | Tetrachloroethylene (PERC) and Carbon Tetrachloride (CCl₄) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-6000 |
| Price Range | USD 21,000 – 28,000 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL6000 |
| Detection Principle | Passive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs) |
| Instrument Type | Portable Handheld Thermal Imaging Gas Detector |
| Configuration | Integrated Dual-Sensor System (Uncooled VOx Microbolometer + Spectrally Filtered IR Detector Array) |
| Temperature Resolution | ≤0.05 °C @ 30 °C |
| Spatial Resolution | 320 × 240 pixels (native IR detector) |
| Thermal Sensitivity (NETD) | <40 mK |
| Minimum Detectable Leak Rate | ~0.1 g/hr (methane equivalent, 10 m distance, 1 m/s wind) |
| Response Time | 1–5 minutes (per localized scan area, dependent on plume concentration, background contrast, and integration time) |
| Accuracy | ±1% of reading (gas concentration estimation via calibrated radiometric back-calculation) |
| Detection Limit | Sub-ppm·m path-integrated concentration (dependent on compound-specific absorption cross-section) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-10 |
| Digestion Method | Rapid Thermal Digestion |
| Heating Module | Single Aluminum Block Heater |
| Batch Capacity | 12 Samples |
| Temperature Range | 32 °C to 399 °C |
| Temperature Accuracy | ±1 °C |
| Total Digestion Volume per Batch | 204 mL (12 × 17 mL vials) |
| Timer Accuracy | ±0.1 s over 10 min duration |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6020 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Measured Gases | O₂, SO₂, NO, NO₂, CO, CO₂, H₂S |
| Flow Accuracy | ≤ ±4.0% |
| Maximum Cumulative Sampling Volume | 999,999.9 L |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-8 |
| Instrument Type | Laboratory |
| Principle | Infrared Spectrophotometry |
| Measurement Range | 0.00–1000 mg/L |
| Detection Limit | <0.0012 mg/L (C₂Cl₄ extract, 4 cm quartz cuvette) |
| Accuracy | ±0.5 mg/L (C < 10 mg/L) |
| Resolution | 0.01 mg/L |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Absorbance Range | 0.0000–3.000 AU |
| Baseline Drift | <0.001 AU/60 min |
| Dimensions | 550 × 380 × 150 mm |
| Weight | 15 kg |
| Power Supply | 220 ± 22 V, 50–60 Hz, 35 VA |
| Brand | Ailun General (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-3010 |
| Price | USD 1,550 (approx.) |
| Flow Range | 0–40 m³/s |
| Sampling Frequency | 3 Hz |
| Level Measurement Accuracy | ≤ ±0.5 mm |
| Flow Measurement Accuracy | ≤ ±1% FS |
| Level Resolution | ≤ 0.1 mm |
| Output Interface | USB |
| Operating Temperature | 0–40 °C |
| Operating Humidity | ≤ 85% RH |
| Battery | 24 V DC Li-ion |
| Continuous Operation Time | 72 h |
| Dimensions | 400 × 300 × 110 mm |
| Weight | 4 kg |
| Brand | Ailun General (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-3020 |
| Liquid Level Range | 0–1000.0 mm (0.1 mm resolution, ≤ ±0.5 mm accuracy) |
| Atmospheric Pressure Range | 60–120 kPa (0.1 kPa resolution, ±0.5 kPa accuracy) |
| Ambient Temperature Range | −40 to +85 °C (0.1 °C resolution, ±2 °C accuracy) |
| Flow Measurement Error | ≤ ±1% |
| Compatible Weirs & Flumes | Triangular Notch Thin-Plate Weir, Rectangular Notch Thin-Plate Weir, Constant-Width Thin-Plate Weir, Parshall Flume |
| Operating Temperature | −5 to +40 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Noise Level | <50 dB |
| Host Weight | ~3.0 kg |
| Dimensions | 280 × 246 × 106 mm |
| Battery | 14.8 V / 10 Ah Li-ion, ≥12 h runtime |
| Power Input | 220 V AC, 50 Hz |
| Power Consumption | ≤40 W |
| Enclosure Rating | IP67 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-F1000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Configuration | Multi-range Composite VOC Detector |
| Detection Range | 1 ppb – 10,000 ppm |
| Resolution | 0.001 ppm |
| Display | 2.4" TFT Color LCD (240 × 320) |
| Sampling Method | Built-in Pump Aspiration |
| Operating Temperature | −30 °C to +50 °C |
| Dimensions | 190 × 80 × 30 mm³ |
| Weight | < 0.5 kg |
| Battery Life | > 6 hours (rechargeable Li-ion) |
| Data Storage | 500,000 records (expandable), up to 65,536 data points per record |
| Environmental Compliance | GB 12358–2006, HJ 872–2017, HJ 1019–2019, HJ 1230–2021 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-FS2010 |
| Price | Upon Request |
| Detector | Large-volume Geiger-Müller (GM) tube |
| Dose Equivalent Rate Range | 0.1 µSv/h – 10 mSv/h |
| Cumulative Dose Range | 0 µSv – 9999 mSv |
| Energy Response | 48 keV – 1.5 MeV |
| Basic Relative Error | ±25% (rate), ±15% (cumulative dose) |
| Display Units | µSv/h, µR/h, CPM / µSv, mSv |
| Alarm Response Time | ≤5 s (at ≥15 µSv/h) |
| Measurement Intervals | 1 s, 60 s, 120 s, 300 s selectable |
| Programmable Alarm Thresholds | 0.25, 0.5, 1.0, 2.5, 5.0, 10, 20, 50, 100 µSv/h |
| LCD Display | Dot-matrix |
| Interface | Mini-USB |
| Power Consumption | ≤2.5 mW |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤90% at 35 °C |
| Weight | 90 g |
| Dimensions | 116 × 60 × 22 mm |
| Data Management | PC-compatible personal dosimetry software with audit-ready export and time-stamped logging |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-AC140 |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Laboratory-Based Analyzer |
| Measurement Principle | Acid Digestion + Molybdenum Blue Colorimetry |
| Measurement Range | 0–10 mg/L (expandable and adjustable) |
| Detection Limit | 0.01 mg/L |
| Repeatability | ≤5% RSD |
| Zero Drift | ≤0.01 mg/L |
| Span Drift | ≤1.0% over 24 h |
| Measurement Cycle | 20–120 min (adjustable in 1-min increments) |
| Digestion Time | Configurable |
| Sampling Interval | 10–9999 min or on-the-hour mode |
| Calibration Interval | 1–99 days, user-definable start time |
| Maintenance Interval | Monthly (~30 min per session) |
| Output Interfaces | RS-232, RS-485, 4–20 mA (optional) |
| Environmental Requirements | Indoor controlled temperature (+5 to +28 °C), humidity ≤90% non-condensing |
| Power Supply | AC 230 ±10 V, 50 ±10 Hz, 5 A |
| Accuracy (Standard Solution) | ±8.0% at 2.0 mg/L, ±5.0% at 5.0 mg/L, ±3.0% at 8.0 mg/L |
| Memory Effect | ≤0.3 mg/L at 2.0 mg/L standard, ≤0.2 mg/L at 8.0 mg/L standard |
| Field Sample Comparison | ≤0.2 mg/L for samples <2.0 mg/L |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-8000 |
| Price Range | USD 140 – 2,100 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HA-6012D2 |
| Price Range | USD 1,400–2,800 |
| Flow Range | 3–30 L/min (selectable) |
| Maximum Vacuum Pressure | >3,000 Pa |
| Flow Accuracy | <±5% |
| Flow Stability | ≤5% |
| Timing Accuracy | <0.1% |
| Sampling Duration | Up to 99 h 59 min |
| Continuous Operation Time | >240 min |
| Noise Level | <70 dB(A) |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | ≤95% RH |
| Dimensions | 210 × 90 × 150 mm |
| Weight | ~2.4 kg |
| Intrinsic Safety Certification | Ex ib I Mb |
| Certified by SHExC (Certificate No. | SHExC20.1643) |
| Preseparator Types | Total Dust Cyclone & Respirable Dust Impactors (BMRC-curve compliant) |
| Battery | High-Capacity Rechargeable Li-ion |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2022 |
| Instrument Type | 24-Hour Isothermal & Isokinetic Gas Sampler |
| Configuration | Dual-Channel Sampling System |
| Flow Range | 0.1–1.0 L/min |
| Flow Accuracy | ±2.5% of reading |
| Flow Stability | ±2.5% over time |
| Temperature Control Range | 15–30 °C |
| Pre-Pressure Measurement | –35 to +35 kPa (±2.5% accuracy) |
| Barometric Pressure Range | 60–120 kPa (±0.5 kPa accuracy) |
| Operating Ambient | –20 to +45 °C, 0–95% RH |
| Battery Runtime | >15 h (7.4 V / 10 Ah Li-ion) |
| Noise Level | <55 dB(A) |
| Power Consumption | <50 W |
| Dimensions | 255 × 163 × 240 mm |
| Weight | ~2.5 kg |
| Compliance | HJ/T 375–2007, JJG 956–2013 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-6022 |
| Price Range | USD 140–1,150 (FOB) |
| Measurement Principle | Laser Light Scattering |
| Safety Classification | Non-Explosive Atmosphere Rated |
| Measurement Range | 0–50 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±15% FS |
| Repeatability | ≤10% CV |
| Detectable Fractions | PM₂.₅, PM₁₀, TSP |
| Sampling Method | Pump-Aspirated |
| Flow Rate | 1.1 L/min |
| Display | LED |
| Power Supply | Internal Rechargeable Li-ion Battery (16.8 V charger included), 10 h continuous operation |
| Operating Temperature | −20 °C to 50 °C |
| Storage Humidity | ≤85% RH (non-condensing) |
| Dimensions | 178 × 94 × 150 mm |
| Weight | 1.0 kg |
| Data Interfaces | RS-232, USB, optional analog output (4–20 mA), optional wireless module |
| Data Storage Capacity | 1,800 records (standard), 30 records for occupational hygiene logging |
| Alarm Outputs | Audible alert + configurable digital switch output (optional) |
| Calibration | Dynamic auto-zero compensation |
| Compliance | JJG 846–2015 (China National Verification Regulation for Dust Concentration Meters) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2051 |
| Sampling Flow Rate | 0.2–1.5 L/min |
| Flow Accuracy | ±0.1% (full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | >15 h |
| Operating Temperature | −20 to +45 °C |
| Operating Humidity | 0–95% RH |
| Dimensions | 240 × 180 × 240 mm |
| Weight | ~2 kg |
| Compliance | HJ/T 47–1999 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-100 |
| Digestion Method | Rapid Closed-Vessel Catalytic Digestion |
| Heating Module | Single Aluminum Alloy Heating Block |
| Batch Capacity | 17 samples |
| Temperature Range | 32–399 °C |
| Temperature Accuracy | ±1 °C |
| Digestion Volume Capacity | 1700 mL (total, distributed across 17 positions) |
| Timer Accuracy | ±0.1 s at 10 min setting |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | AL-4 |
| Instrument Type | Portable |
| Configuration | Multi-Gas VOC Detector |
| Detection Range | Selectable (0–50, 100, 200, 1000, 2000, or 10,000 ppm) |
| Resolution | 0.01 ppm |
| Accuracy | ±3% FS |
| Repeatability | ≤±2% |
| Linearity | ≤±2% |
| Response Time (T90) | ≤20 s |
| Sampling Method | Integrated Active Pump |
| Flow Rate | 500 mL/min |
| Display | 2.3-inch High-Resolution Color LCD |
| Interface Languages | English & Chinese |
| Data Storage | 100,000 records |
| Communication | USB port (RS232 optional) |
| Battery | 4500 mAh Li-Polymer rechargeable |
| Charging | Micro-USB |
| Alarm | Triple-mode (audible, visual, vibration) |
| Ingress Protection | IP65 |
| Explosion Protection | Ex ia II CT6 |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–99% RH (non-condensing) |
| Dimensions | 165 × 75 × 30 mm |
| Weight | 0.3 kg |
| Standard Accessories | Host unit, USB charger, hydrophobic dust filter, aluminum carrying case, certificate of conformity, warranty card, user manual |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-SZ5000 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measured Parameters | COD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN) |
| Measurement Range | COD 5–10,000 mg/L |
| Display | 7-inch color LCD touchscreen |
| Optical System | Imported fiber-optic detection system |
| Wavelength Range | 340–900 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 4 nm |
| Light Source | Imported 12 V / 20 W halogen lamp (rated life >100,000 h) |
| Detection Method | Cuvette-based colorimetry with pre-filled reagent vials |
| Resolution | 0.001 mg/L (for applicable ranges) |
| Accuracy | ≤±5% FS |
| Repeatability | ≤±2% RSD |
| Pre-stored Calibration Curves | 100 factory-loaded standard curves + 10 user-definable fitting curves |
| Data Storage | Up to 1,000,000 measurement records with timestamped retrieval |
| Auto-calibration | Yes, with fixed reference channel |
| Digestion Unit | Integrated 16-position digestion block (standard configuration) |
| Printer | Built-in thermal printer for real-time and historical data output |
| Data Interface | USB port + RS-232 serial interface |
| Compliance Standards | HJ 535-2009, GB 11893-1989, HJ/T 399-2007 |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-6800 |
| Measurement Range | 0–200 µg/L (standard), 0–2000 µg/L (extended) |
| Accuracy | ±2% F.S. |
| Resolution | 0.1 µg/L |
| Repeatability | ≤1.5% |
| Stability | ±1.5% F.S. / 4 h |
| Display | 7.0-inch color TFT touchscreen |
| Power Supply | 85–265 VAC, 45–65 Hz |
| Power Consumption | 30 W |
| Dimensions (L×W×H) | 280 × 310 × 180 mm |
| Weight | 5 kg |
| Enclosure | Stainless steel, IP65-rated housing |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, supports GLP data integrity requirements |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-3019A |
| Instrument Type | Portable |
| Detection Target | Single-component CO₂ |
| Measurement Range | 0–0.500% (configurable to 0–1.000%) |
| Resolution | 0.001% |
| Repeatability | ≤1% FS |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3h |
| Response Time (t₀–t₉₀) | ≤15 s |
| Flow Rate | 0.5–1.0 L/min |
| Temperature Error | ≤±2% FS/10°C (10–45°C) |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Warm-up Time | ≤10 min |
| Data Storage Capacity | Up to 10,000 records |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 235 × 160 × 145 mm |
| Weight | ≤2 kg |
| Compliance | GB/T 18204.2–2014, GBZ/T 300.37–2017, HJ 870–2017, JJG 635–2011 |
| Calibration Traceability | Certified to Class II accuracy per Chinese national metrological standards |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HA-6012D |
| Flow Range | 5–30 L/min |
| Maximum Negative Pressure | >3000 Pa |
| Sampling Modes | Respirable & Total Dust (dual-head configuration) |
| Battery Runtime | >180 min (typical) |
| Flow Stability | ≤5% |
| Noise Level | <65 dB(A) |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤85% RH |
| Ambient Pressure Range | 80–110 kPa |
| Weight | ~2.0 kg |
| Dimensions | 200 × 75 × 140 mm |
| Explosion Protection | Ex ib I Mb (IEC 60079-0, IEC 60079-11) |
| Timer Range | 00:00 to 99:59 h:min (user-selectable) |
| Flow Accuracy | ±5% FS |
| Compliance | MT162–1995, Q/FY-02–2005, GB 3836.1–2010 / GB 3836.4–2010, CPA Type Approval Certificate Available |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-6023 |
| Measurement Principle | Laser Light Scattering |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0–300,000 µg/m³ (PM₂.₅/PM₁₀/TSP) |
| Resolution | 1 µg/m³ |
| Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% (100–300,000 µg/m³) |
| Flow Rate | 1.0 L/min ±2.5% |
| Display | 4.3″ capacitive touchscreen |
| Data Storage | ≥500 records (general mode), ≥50 records (occupational hygiene mode) |
| Battery | 7.4 V / 7.8 Ah Li-ion, >8 h continuous operation |
| Dimensions | 210 × 100 × 190 mm |
| Weight | ~1.8 kg |
| Communication | USB, optional Bluetooth, RS232/RS485, 4G module |
Show next