Empowering Scientific Discovery

Qingdao Elun General Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelAilun 6080
PriceUSD 118,000 (FOB Qingdao)
Detection PrinciplePassive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs)
Instrument TypePortable
Typical ConfigurationDual-Mode VOC Imaging & Precision Thermography System
Thermal Sensitivity (NETD)≤0.01 °C @ 30 °C
Volumetric Leak Detection Sensitivity≤0.001 mL/s (for methane, propane, and common C1–C4 hydrocarbons under ISO 16000-22–compliant field conditions)
Detector TypeCooled Type-II Strained-Layer Superlattice (T2SL) focal plane array
Weight2.4 kg
Explosion Protection RatingEx ic nC op is IIC T6 Gc (IEC 60079-0, -7, -11, -15, -31)
Data StorageInternal SD card (up to 512 GB, FAT32 formatted), supports JPEG thermal images, radiometric MP4 video, and CSV metadata export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDM-600(III)
Instrument TypePortable
PrincipleInfrared Spectrophotometry (Fourier-transform-free dispersive IR)
Measurement Range0.00–64,000 mg/L
Detection Limit0.0012 mg/L (as oil in water)
Accuracy±2% of reading
Spectral Resolution1 cm⁻¹
Analysis Time per Sample≤60 s
Wavenumber Accuracy±1 cm⁻¹
Absorbance Range0.00000–2.00000 AU
Wavenumber Range2400–3400 cm⁻¹
Operating Temperature−5 to 50 °C
Relative Humidity20–95% RH (non-condensing)
Power SupplyInternal Li-ion battery (≥8 h continuous operation) or 12 V DC automotive input
Compatible Extraction SolventsTetrachloroethylene (PERC) and Carbon Tetrachloride (CCl₄)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-6000
Price RangeUSD 21,000 – 28,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL6000
Detection PrinciplePassive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs)
Instrument TypePortable Handheld Thermal Imaging Gas Detector
ConfigurationIntegrated Dual-Sensor System (Uncooled VOx Microbolometer + Spectrally Filtered IR Detector Array)
Temperature Resolution≤0.05 °C @ 30 °C
Spatial Resolution320 × 240 pixels (native IR detector)
Thermal Sensitivity (NETD)<40 mK
Minimum Detectable Leak Rate~0.1 g/hr (methane equivalent, 10 m distance, 1 m/s wind)
Response Time1–5 minutes (per localized scan area, dependent on plume concentration, background contrast, and integration time)
Accuracy±1% of reading (gas concentration estimation via calibrated radiometric back-calculation)
Detection LimitSub-ppm·m path-integrated concentration (dependent on compound-specific absorption cross-section)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAC-10
Digestion MethodRapid Thermal Digestion
Heating ModuleSingle Aluminum Block Heater
Batch Capacity12 Samples
Temperature Range32 °C to 399 °C
Temperature Accuracy±1 °C
Total Digestion Volume per Batch204 mL (12 × 17 mL vials)
Timer Accuracy±0.1 s over 10 min duration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHB6020
Instrument TypeFlue Gas and Particulate Sampler
Measured GasesO₂, SO₂, NO, NO₂, CO, CO₂, H₂S
Flow Accuracy≤ ±4.0%
Maximum Cumulative Sampling Volume999,999.9 L
Flue Gas Velocity Range1–45 m/s
Moisture Content Range0–60%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelAL-8
Instrument TypeLaboratory
PrincipleInfrared Spectrophotometry
Measurement Range0.00–1000 mg/L
Detection Limit<0.0012 mg/L (C₂Cl₄ extract, 4 cm quartz cuvette)
Accuracy±0.5 mg/L (C < 10 mg/L)
Resolution0.01 mg/L
Wavenumber Range3400–2400 cm⁻¹
Absorbance Range0.0000–3.000 AU
Baseline Drift<0.001 AU/60 min
Dimensions550 × 380 × 150 mm
Weight15 kg
Power Supply220 ± 22 V, 50–60 Hz, 35 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General (Qingdao Ailun)
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-3010
PriceUSD 1,550 (approx.)
Flow Range0–40 m³/s
Sampling Frequency3 Hz
Level Measurement Accuracy≤ ±0.5 mm
Flow Measurement Accuracy≤ ±1% FS
Level Resolution≤ 0.1 mm
Output InterfaceUSB
Operating Temperature0–40 °C
Operating Humidity≤ 85% RH
Battery24 V DC Li-ion
Continuous Operation Time72 h
Dimensions400 × 300 × 110 mm
Weight4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General (Qingdao Ailun)
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-3020
Liquid Level Range0–1000.0 mm (0.1 mm resolution, ≤ ±0.5 mm accuracy)
Atmospheric Pressure Range60–120 kPa (0.1 kPa resolution, ±0.5 kPa accuracy)
Ambient Temperature Range−40 to +85 °C (0.1 °C resolution, ±2 °C accuracy)
Flow Measurement Error≤ ±1%
Compatible Weirs & FlumesTriangular Notch Thin-Plate Weir, Rectangular Notch Thin-Plate Weir, Constant-Width Thin-Plate Weir, Parshall Flume
Operating Temperature−5 to +40 °C
Operating Humidity0–95% RH (non-condensing)
Noise Level<50 dB
Host Weight~3.0 kg
Dimensions280 × 246 × 106 mm
Battery14.8 V / 10 Ah Li-ion, ≥12 h runtime
Power Input220 V AC, 50 Hz
Power Consumption≤40 W
Enclosure RatingIP67
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelAL-F1000
Detection PrinciplePhotoionization Detection (PID)
Instrument TypePortable
ConfigurationMulti-range Composite VOC Detector
Detection Range1 ppb – 10,000 ppm
Resolution0.001 ppm
Display2.4" TFT Color LCD (240 × 320)
Sampling MethodBuilt-in Pump Aspiration
Operating Temperature−30 °C to +50 °C
Dimensions190 × 80 × 30 mm³
Weight< 0.5 kg
Battery Life> 6 hours (rechargeable Li-ion)
Data Storage500,000 records (expandable), up to 65,536 data points per record
Environmental ComplianceGB 12358–2006, HJ 872–2017, HJ 1019–2019, HJ 1230–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-FS2010
PriceUpon Request
DetectorLarge-volume Geiger-Müller (GM) tube
Dose Equivalent Rate Range0.1 µSv/h – 10 mSv/h
Cumulative Dose Range0 µSv – 9999 mSv
Energy Response48 keV – 1.5 MeV
Basic Relative Error±25% (rate), ±15% (cumulative dose)
Display UnitsµSv/h, µR/h, CPM / µSv, mSv
Alarm Response Time≤5 s (at ≥15 µSv/h)
Measurement Intervals1 s, 60 s, 120 s, 300 s selectable
Programmable Alarm Thresholds0.25, 0.5, 1.0, 2.5, 5.0, 10, 20, 50, 100 µSv/h
LCD DisplayDot-matrix
InterfaceMini-USB
Power Consumption≤2.5 mW
Operating Temperature−10 °C to +50 °C
Relative Humidity≤90% at 35 °C
Weight90 g
Dimensions116 × 60 × 22 mm
Data ManagementPC-compatible personal dosimetry software with audit-ready export and time-stamped logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-AC140
Measurement ParameterTotal Phosphorus
Instrument TypeLaboratory-Based Analyzer
Measurement PrincipleAcid Digestion + Molybdenum Blue Colorimetry
Measurement Range0–10 mg/L (expandable and adjustable)
Detection Limit0.01 mg/L
Repeatability≤5% RSD
Zero Drift≤0.01 mg/L
Span Drift≤1.0% over 24 h
Measurement Cycle20–120 min (adjustable in 1-min increments)
Digestion TimeConfigurable
Sampling Interval10–9999 min or on-the-hour mode
Calibration Interval1–99 days, user-definable start time
Maintenance IntervalMonthly (~30 min per session)
Output InterfacesRS-232, RS-485, 4–20 mA (optional)
Environmental RequirementsIndoor controlled temperature (+5 to +28 °C), humidity ≤90% non-condensing
Power SupplyAC 230 ±10 V, 50 ±10 Hz, 5 A
Accuracy (Standard Solution)±8.0% at 2.0 mg/L, ±5.0% at 5.0 mg/L, ±3.0% at 8.0 mg/L
Memory Effect≤0.3 mg/L at 2.0 mg/L standard, ≤0.2 mg/L at 8.0 mg/L standard
Field Sample Comparison≤0.2 mg/L for samples <2.0 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-8000
Price RangeUSD 140 – 2,100
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHA-6012D2
Price RangeUSD 1,400–2,800
Flow Range3–30 L/min (selectable)
Maximum Vacuum Pressure>3,000 Pa
Flow Accuracy<±5%
Flow Stability≤5%
Timing Accuracy<0.1%
Sampling DurationUp to 99 h 59 min
Continuous Operation Time>240 min
Noise Level<70 dB(A)
Operating Temperature−20 °C to +40 °C
Relative Humidity≤95% RH
Dimensions210 × 90 × 150 mm
Weight~2.4 kg
Intrinsic Safety CertificationEx ib I Mb
Certified by SHExC (Certificate No.SHExC20.1643)
Preseparator TypesTotal Dust Cyclone & Respirable Dust Impactors (BMRC-curve compliant)
BatteryHigh-Capacity Rechargeable Li-ion
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelAL-2022
Instrument Type24-Hour Isothermal & Isokinetic Gas Sampler
ConfigurationDual-Channel Sampling System
Flow Range0.1–1.0 L/min
Flow Accuracy±2.5% of reading
Flow Stability±2.5% over time
Temperature Control Range15–30 °C
Pre-Pressure Measurement–35 to +35 kPa (±2.5% accuracy)
Barometric Pressure Range60–120 kPa (±0.5 kPa accuracy)
Operating Ambient–20 to +45 °C, 0–95% RH
Battery Runtime>15 h (7.4 V / 10 Ah Li-ion)
Noise Level<55 dB(A)
Power Consumption<50 W
Dimensions255 × 163 × 240 mm
Weight~2.5 kg
ComplianceHJ/T 375–2007, JJG 956–2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-6022
Price RangeUSD 140–1,150 (FOB)
Measurement PrincipleLaser Light Scattering
Safety ClassificationNon-Explosive Atmosphere Rated
Measurement Range0–50 mg/m³
Resolution0.001 mg/m³
Accuracy±15% FS
Repeatability≤10% CV
Detectable FractionsPM₂.₅, PM₁₀, TSP
Sampling MethodPump-Aspirated
Flow Rate1.1 L/min
DisplayLED
Power SupplyInternal Rechargeable Li-ion Battery (16.8 V charger included), 10 h continuous operation
Operating Temperature−20 °C to 50 °C
Storage Humidity≤85% RH (non-condensing)
Dimensions178 × 94 × 150 mm
Weight1.0 kg
Data InterfacesRS-232, USB, optional analog output (4–20 mA), optional wireless module
Data Storage Capacity1,800 records (standard), 30 records for occupational hygiene logging
Alarm OutputsAudible alert + configurable digital switch output (optional)
CalibrationDynamic auto-zero compensation
ComplianceJJG 846–2015 (China National Verification Regulation for Dust Concentration Meters)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelAL-2051
Sampling Flow Rate0.2–1.5 L/min
Flow Accuracy±0.1% (full scale)
Power SupplyAC 220 V ±10%, 50 Hz
Continuous Operation Time>15 h
Operating Temperature−20 to +45 °C
Operating Humidity0–95% RH
Dimensions240 × 180 × 240 mm
Weight~2 kg
ComplianceHJ/T 47–1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAC-100
Digestion MethodRapid Closed-Vessel Catalytic Digestion
Heating ModuleSingle Aluminum Alloy Heating Block
Batch Capacity17 samples
Temperature Range32–399 °C
Temperature Accuracy±1 °C
Digestion Volume Capacity1700 mL (total, distributed across 17 positions)
Timer Accuracy±0.1 s at 10 min setting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelAL-4
Instrument TypePortable
ConfigurationMulti-Gas VOC Detector
Detection RangeSelectable (0–50, 100, 200, 1000, 2000, or 10,000 ppm)
Resolution0.01 ppm
Accuracy±3% FS
Repeatability≤±2%
Linearity≤±2%
Response Time (T90)≤20 s
Sampling MethodIntegrated Active Pump
Flow Rate500 mL/min
Display2.3-inch High-Resolution Color LCD
Interface LanguagesEnglish & Chinese
Data Storage100,000 records
CommunicationUSB port (RS232 optional)
Battery4500 mAh Li-Polymer rechargeable
ChargingMicro-USB
AlarmTriple-mode (audible, visual, vibration)
Ingress ProtectionIP65
Explosion ProtectionEx ia II CT6
Operating Temperature−40 °C to +70 °C
Operating Humidity0–99% RH (non-condensing)
Dimensions165 × 75 × 30 mm
Weight0.3 kg
Standard AccessoriesHost unit, USB charger, hydrophobic dust filter, aluminum carrying case, certificate of conformity, warranty card, user manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-SZ5000
Instrument TypeLaboratory Water Quality Analyzer
Measured ParametersCOD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN)
Measurement RangeCOD 5–10,000 mg/L
Display7-inch color LCD touchscreen
Optical SystemImported fiber-optic detection system
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Spectral Bandwidth4 nm
Light SourceImported 12 V / 20 W halogen lamp (rated life >100,000 h)
Detection MethodCuvette-based colorimetry with pre-filled reagent vials
Resolution0.001 mg/L (for applicable ranges)
Accuracy≤±5% FS
Repeatability≤±2% RSD
Pre-stored Calibration Curves100 factory-loaded standard curves + 10 user-definable fitting curves
Data StorageUp to 1,000,000 measurement records with timestamped retrieval
Auto-calibrationYes, with fixed reference channel
Digestion UnitIntegrated 16-position digestion block (standard configuration)
PrinterBuilt-in thermal printer for real-time and historical data output
Data InterfaceUSB port + RS-232 serial interface
Compliance StandardsHJ 535-2009, GB 11893-1989, HJ/T 399-2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-6800
Measurement Range0–200 µg/L (standard), 0–2000 µg/L (extended)
Accuracy±2% F.S.
Resolution0.1 µg/L
Repeatability≤1.5%
Stability±1.5% F.S. / 4 h
Display7.0-inch color TFT touchscreen
Power Supply85–265 VAC, 45–65 Hz
Power Consumption30 W
Dimensions (L×W×H)280 × 310 × 180 mm
Weight5 kg
EnclosureStainless steel, IP65-rated housing
ComplianceDesigned for ISO/IEC 17025-aligned laboratory environments, supports GLP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-3019A
Instrument TypePortable
Detection TargetSingle-component CO₂
Measurement Range0–0.500% (configurable to 0–1.000%)
Resolution0.001%
Repeatability≤1% FS
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3h
Response Time (t₀–t₉₀)≤15 s
Flow Rate0.5–1.0 L/min
Temperature Error≤±2% FS/10°C (10–45°C)
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Warm-up Time≤10 min
Data Storage CapacityUp to 10,000 records
Power SupplyAC 220 V (±10%) or rechargeable Li-ion battery
Dimensions235 × 160 × 145 mm
Weight≤2 kg
ComplianceGB/T 18204.2–2014, GBZ/T 300.37–2017, HJ 870–2017, JJG 635–2011
Calibration TraceabilityCertified to Class II accuracy per Chinese national metrological standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHA-6012D
Flow Range5–30 L/min
Maximum Negative Pressure>3000 Pa
Sampling ModesRespirable & Total Dust (dual-head configuration)
Battery Runtime>180 min (typical)
Flow Stability≤5%
Noise Level<65 dB(A)
Operating Temperature−10°C to +40°C
Relative Humidity≤85% RH
Ambient Pressure Range80–110 kPa
Weight~2.0 kg
Dimensions200 × 75 × 140 mm
Explosion ProtectionEx ib I Mb (IEC 60079-0, IEC 60079-11)
Timer Range00:00 to 99:59 h:min (user-selectable)
Flow Accuracy±5% FS
ComplianceMT162–1995, Q/FY-02–2005, GB 3836.1–2010 / GB 3836.4–2010, CPA Type Approval Certificate Available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-6023
Measurement PrincipleLaser Light Scattering
Safety RatingNon-explosion-proof
Measurement Range0–300,000 µg/m³ (PM₂.₅/PM₁₀/TSP)
Resolution1 µg/m³
Accuracy±10 µg/m³ (≤100 µg/m³), ±10% (100–300,000 µg/m³)
Flow Rate1.0 L/min ±2.5%
Display4.3″ capacitive touchscreen
Data Storage≥500 records (general mode), ≥50 records (occupational hygiene mode)
Battery7.4 V / 7.8 Ah Li-ion, >8 h continuous operation
Dimensions210 × 100 × 190 mm
Weight~1.8 kg
CommunicationUSB, optional Bluetooth, RS232/RS485, 4G module
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0