Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDM-600(III)
Instrument TypePortable
PrincipleInfrared Spectrophotometry (Fourier-transform-free dispersive IR)
Measurement Range0.00–64,000 mg/L
Detection Limit0.0012 mg/L (as oil in water)
Accuracy±2% of reading
Spectral Resolution1 cm⁻¹
Analysis Time per Sample≤60 s
Wavenumber Accuracy±1 cm⁻¹
Absorbance Range0.00000–2.00000 AU
Wavenumber Range2400–3400 cm⁻¹
Operating Temperature−5 to 50 °C
Relative Humidity20–95% RH (non-condensing)
Power SupplyInternal Li-ion battery (≥8 h continuous operation) or 12 V DC automotive input
Compatible Extraction SolventsTetrachloroethylene (PERC) and Carbon Tetrachloride (CCl₄)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-6000
Price RangeUSD 21,000 – 28,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAC-10
Digestion MethodRapid Thermal Digestion
Heating ModuleSingle Aluminum Block Heater
Batch Capacity12 Samples
Temperature Range32 °C to 399 °C
Temperature Accuracy±1 °C
Total Digestion Volume per Batch204 mL (12 × 17 mL vials)
Timer Accuracy±0.1 s over 10 min duration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelAL-8
Instrument TypeLaboratory
PrincipleInfrared Spectrophotometry
Measurement Range0.00–1000 mg/L
Detection Limit<0.0012 mg/L (C₂Cl₄ extract, 4 cm quartz cuvette)
Accuracy±0.5 mg/L (C < 10 mg/L)
Resolution0.01 mg/L
Wavenumber Range3400–2400 cm⁻¹
Absorbance Range0.0000–3.000 AU
Baseline Drift<0.001 AU/60 min
Dimensions550 × 380 × 150 mm
Weight15 kg
Power Supply220 ± 22 V, 50–60 Hz, 35 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General (Qingdao Ailun)
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-3010
PriceUSD 1,550 (approx.)
Flow Range0–40 m³/s
Sampling Frequency3 Hz
Level Measurement Accuracy≤ ±0.5 mm
Flow Measurement Accuracy≤ ±1% FS
Level Resolution≤ 0.1 mm
Output InterfaceUSB
Operating Temperature0–40 °C
Operating Humidity≤ 85% RH
Battery24 V DC Li-ion
Continuous Operation Time72 h
Dimensions400 × 300 × 110 mm
Weight4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General (Qingdao Ailun)
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-3020
Liquid Level Range0–1000.0 mm (0.1 mm resolution, ≤ ±0.5 mm accuracy)
Atmospheric Pressure Range60–120 kPa (0.1 kPa resolution, ±0.5 kPa accuracy)
Ambient Temperature Range−40 to +85 °C (0.1 °C resolution, ±2 °C accuracy)
Flow Measurement Error≤ ±1%
Compatible Weirs & FlumesTriangular Notch Thin-Plate Weir, Rectangular Notch Thin-Plate Weir, Constant-Width Thin-Plate Weir, Parshall Flume
Operating Temperature−5 to +40 °C
Operating Humidity0–95% RH (non-condensing)
Noise Level<50 dB
Host Weight~3.0 kg
Dimensions280 × 246 × 106 mm
Battery14.8 V / 10 Ah Li-ion, ≥12 h runtime
Power Input220 V AC, 50 Hz
Power Consumption≤40 W
Enclosure RatingIP67
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-AC140
Measurement ParameterTotal Phosphorus
Instrument TypeLaboratory-Based Analyzer
Measurement PrincipleAcid Digestion + Molybdenum Blue Colorimetry
Measurement Range0–10 mg/L (expandable and adjustable)
Detection Limit0.01 mg/L
Repeatability≤5% RSD
Zero Drift≤0.01 mg/L
Span Drift≤1.0% over 24 h
Measurement Cycle20–120 min (adjustable in 1-min increments)
Digestion TimeConfigurable
Sampling Interval10–9999 min or on-the-hour mode
Calibration Interval1–99 days, user-definable start time
Maintenance IntervalMonthly (~30 min per session)
Output InterfacesRS-232, RS-485, 4–20 mA (optional)
Environmental RequirementsIndoor controlled temperature (+5 to +28 °C), humidity ≤90% non-condensing
Power SupplyAC 230 ±10 V, 50 ±10 Hz, 5 A
Accuracy (Standard Solution)±8.0% at 2.0 mg/L, ±5.0% at 5.0 mg/L, ±3.0% at 8.0 mg/L
Memory Effect≤0.3 mg/L at 2.0 mg/L standard, ≤0.2 mg/L at 8.0 mg/L standard
Field Sample Comparison≤0.2 mg/L for samples <2.0 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAC-100
Digestion MethodRapid Closed-Vessel Catalytic Digestion
Heating ModuleSingle Aluminum Alloy Heating Block
Batch Capacity17 samples
Temperature Range32–399 °C
Temperature Accuracy±1 °C
Digestion Volume Capacity1700 mL (total, distributed across 17 positions)
Timer Accuracy±0.1 s at 10 min setting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-SZ5000
Instrument TypeLaboratory Water Quality Analyzer
Measured ParametersCOD, Ammonia Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN)
Measurement RangeCOD 5–10,000 mg/L
Display7-inch color LCD touchscreen
Optical SystemImported fiber-optic detection system
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Spectral Bandwidth4 nm
Light SourceImported 12 V / 20 W halogen lamp (rated life >100,000 h)
Detection MethodCuvette-based colorimetry with pre-filled reagent vials
Resolution0.001 mg/L (for applicable ranges)
Accuracy≤±5% FS
Repeatability≤±2% RSD
Pre-stored Calibration Curves100 factory-loaded standard curves + 10 user-definable fitting curves
Data StorageUp to 1,000,000 measurement records with timestamped retrieval
Auto-calibrationYes, with fixed reference channel
Digestion UnitIntegrated 16-position digestion block (standard configuration)
PrinterBuilt-in thermal printer for real-time and historical data output
Data InterfaceUSB port + RS-232 serial interface
Compliance StandardsHJ 535-2009, GB 11893-1989, HJ/T 399-2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-6800
Measurement Range0–200 µg/L (standard), 0–2000 µg/L (extended)
Accuracy±2% F.S.
Resolution0.1 µg/L
Repeatability≤1.5%
Stability±1.5% F.S. / 4 h
Display7.0-inch color TFT touchscreen
Power Supply85–265 VAC, 45–65 Hz
Power Consumption30 W
Dimensions (L×W×H)280 × 310 × 180 mm
Weight5 kg
EnclosureStainless steel, IP65-rated housing
ComplianceDesigned for ISO/IEC 17025-aligned laboratory environments, supports GLP data integrity requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginQingdao, Shandong, China
ModelAL-AC120
Instrument TypeOnline Water Quality Analyzer
Measuring ParameterChemical Oxygen Demand (COD)
Measurement Range0–5000 mg/L
LOD≤15 mg/L (±30% error at low end)
Repeatability≤±5%
Low-Concentration Drift±5 mg/L
High-Concentration Drift≤5%
Minimum Cycle Time20 min
Adjustable Sampling Interval10–9999 min
Digestion TimeConfigurable per application
Calibration Interval1–99 days
Maintenance Interval~30 days (~60 min/session)
Output InterfacesRS-232, RS-485, 4–20 mA (optional)
Operating Temperature+5 to +28 °C (climate-controlled indoor environment)
Relative Humidity≤90% non-condensing
Power SupplyAC 220 V ±10%, 50 Hz ±10%, 5 A
Accuracy (Standard Solution Validation)±10.0% at 40.0 mg/L
Memory Effect±10.0% at 40.0 mg/L
Field Sample Comparison Tolerance≤5 mg/L for samples <50.0 mg/L
Chloride Interference ToleranceStandard mode ≤2.5 g/L Cl⁻
Control SystemPanasonic PLC-based embedded controller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelISC-10
Instrument CategoryAutomatic Sampler
Sampling ModeTime-Programmed & Volume-Controlled
Instrument Form FactorPortable Water Sampler
Single Sample Volume8000 mL
Sampling Volume Accuracy±0.01 mL
Sampling Speed Range0.01–15 mm/min
Programmable Sampling IntervalYes
Minimum Sampling Depth≥1.0 m
Rainfall Detection Threshold≥0.02 mm/h or ≥0.5 mm raindrop diameter
Rain Gauge Range0–4 mm/min
Rainfall Measurement Accuracy±0.4 mm (≤10 mm)
Rain Gauge Resolution0.1 mm
Data Storage Capacity≥1000 rainfall events
Operating Temperature−40 °C to +50 °C
Relative Humidity Toleranceup to 99% RH
Wind Resistance≤ Beaufort Scale 9
Power SupplyAC 220 V, 50 Hz / DC backup capable
Standby Power Consumption2 W
Compliance StandardHJ/T 174–2005
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
ModelUV-300
Instrument TypeLaboratory
Measurement PrincipleUltraviolet Spectrophotometry
Measurement Range0–50 mg/L
Detection Limit0.01 mg/L
Accuracy±2%
Spectral Resolution1 cm⁻¹
Analysis Cycle Time5–10 min per sample
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-SZ5000Plus
Detection ParametersCOD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity
Measurement RangeCOD 5–10,000 mg/L
Wavelength Range340–900 nm
Optical Bandwidth4 nm
Wavelength Accuracy±1 nm
Display7-inch color LCD touchscreen
Data StorageUp to 1,000,000 measurement records
Pre-stored Calibration Curves280 standard + 50 user-fittable curves
Photometric SystemFiber-optic detection architecture
Light SourceImported 12 V / 20 W halogen lamp (≥100,000 h lifetime)
Detection ModesRotating 360° cuvette holder (pre-filled reagent vials) + dual-channel automatic cuvette loader (powder/solid reagents)
Repeatability≤±2%
Accuracy≤±5%
Inter-channel Error≤±2%
Digestion UnitIntegrated 16-position heating block compliant with HJ/T 399–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General / Qingdao Ailun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelISC-8
Instrument TypeLaboratory-Based Automatic Water Sampler
Sampling ModeQuantitative Sampling
Single Sample Volume9000 mL
Sampling Volume Accuracy±0.02 mL
Sampling Speed0.01–15 mm/min
Programmable Sampling IntervalYes
Maximum Sampling Depth≥1.0 m
Collection Funnel Diameter200 mm
Max Collection Bucket Capacity10 L
Power Consumption40 W
Data Storage Capacity255 Rain Events (Start/Stop Time + Duration)
Lightning ProtectionMulti-Stage Integrated Surge Suppression
Environmental Operating Range-20°C to +60°C
Housing MaterialStainless Steel with Anti-Contamination Liner
Sensor TypeCoupled Pulse Sensor Array (Multi-Point Rain Detection)
MicrocontrollerSamsung S3C2440A ARM9-based Embedded Processor
Power Failure ProtectionNon-Volatile Memory Backup
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun General
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-GM100
Measurement PrincipleAcidic Potassium Permanganate Oxidation (Standardized Wet Chemical Method)
Instrument TypeBenchtop Laboratory Analyzer
Range0–5 mg/L
Repeatability±2% RSD
Accuracy±3% of reading
LOD0.05 mg/L
Dispensing Resolution1 µL
Analysis Time per Sample4 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun (Qingdao Ailun)
OriginShandong, China
ModelAL-AC130
Measurement PrincipleColorimetric Method (Nesslerization or Salicylate-based)
Measurement Range0–500 mg/L NH₃–N (expandable)
Detection Limit≤0.15 mg/L (±30% error at LOD)
Accuracy±8.0% at 2.0 mg/L
Repeatability≤2% RSD
Low-concentration Drift≤0.02 mg/L/24h
High-concentration Drift≤1.0 mg/L/24h
Minimum Cycle Time20 min (color development time adjustable from 5–120 min)
Sample Throughput10 samples per batch
Sampling Interval10–9999 min programmable + on-the-hour mode
Calibration Interval1–99 days, user-defined start time
Maintenance Interval>720 hours
Output InterfacesRS-232, RS-485, 4–20 mA (optional)
Operating Environment+5 to +28 °C, ≤90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz ±10%, 5 A
Memory Effect≤0.3 mg/L at 2.0 mg/L standard
Field Validation≤0.2 mg/L bias for samples <2.0 mg/L