| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Ailun 6080 |
| Price | USD 118,000 (FOB Qingdao) |
| Detection Principle | Passive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs) |
| Instrument Type | Portable |
| Typical Configuration | Dual-Mode VOC Imaging & Precision Thermography System |
| Thermal Sensitivity (NETD) | ≤0.01 °C @ 30 °C |
| Volumetric Leak Detection Sensitivity | ≤0.001 mL/s (for methane, propane, and common C1–C4 hydrocarbons under ISO 16000-22–compliant field conditions) |
| Detector Type | Cooled Type-II Strained-Layer Superlattice (T2SL) focal plane array |
| Weight | 2.4 kg |
| Explosion Protection Rating | Ex ic nC op is IIC T6 Gc (IEC 60079-0, -7, -11, -15, -31) |
| Data Storage | Internal SD card (up to 512 GB, FAT32 formatted), supports JPEG thermal images, radiometric MP4 video, and CSV metadata export |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL6000 |
| Detection Principle | Passive Infrared Absorption Imaging (Mid-Wave IR, 3.2–3.5 µm spectral band optimized for hydrocarbon VOCs) |
| Instrument Type | Portable Handheld Thermal Imaging Gas Detector |
| Configuration | Integrated Dual-Sensor System (Uncooled VOx Microbolometer + Spectrally Filtered IR Detector Array) |
| Temperature Resolution | ≤0.05 °C @ 30 °C |
| Spatial Resolution | 320 × 240 pixels (native IR detector) |
| Thermal Sensitivity (NETD) | <40 mK |
| Minimum Detectable Leak Rate | ~0.1 g/hr (methane equivalent, 10 m distance, 1 m/s wind) |
| Response Time | 1–5 minutes (per localized scan area, dependent on plume concentration, background contrast, and integration time) |
| Accuracy | ±1% of reading (gas concentration estimation via calibrated radiometric back-calculation) |
| Detection Limit | Sub-ppm·m path-integrated concentration (dependent on compound-specific absorption cross-section) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6020 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Measured Gases | O₂, SO₂, NO, NO₂, CO, CO₂, H₂S |
| Flow Accuracy | ≤ ±4.0% |
| Maximum Cumulative Sampling Volume | 999,999.9 L |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-F1000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Configuration | Multi-range Composite VOC Detector |
| Detection Range | 1 ppb – 10,000 ppm |
| Resolution | 0.001 ppm |
| Display | 2.4" TFT Color LCD (240 × 320) |
| Sampling Method | Built-in Pump Aspiration |
| Operating Temperature | −30 °C to +50 °C |
| Dimensions | 190 × 80 × 30 mm³ |
| Weight | < 0.5 kg |
| Battery Life | > 6 hours (rechargeable Li-ion) |
| Data Storage | 500,000 records (expandable), up to 65,536 data points per record |
| Environmental Compliance | GB 12358–2006, HJ 872–2017, HJ 1019–2019, HJ 1230–2021 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HA-6012D2 |
| Price Range | USD 1,400–2,800 |
| Flow Range | 3–30 L/min (selectable) |
| Maximum Vacuum Pressure | >3,000 Pa |
| Flow Accuracy | <±5% |
| Flow Stability | ≤5% |
| Timing Accuracy | <0.1% |
| Sampling Duration | Up to 99 h 59 min |
| Continuous Operation Time | >240 min |
| Noise Level | <70 dB(A) |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | ≤95% RH |
| Dimensions | 210 × 90 × 150 mm |
| Weight | ~2.4 kg |
| Intrinsic Safety Certification | Ex ib I Mb |
| Certified by SHExC (Certificate No. | SHExC20.1643) |
| Preseparator Types | Total Dust Cyclone & Respirable Dust Impactors (BMRC-curve compliant) |
| Battery | High-Capacity Rechargeable Li-ion |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2022 |
| Instrument Type | 24-Hour Isothermal & Isokinetic Gas Sampler |
| Configuration | Dual-Channel Sampling System |
| Flow Range | 0.1–1.0 L/min |
| Flow Accuracy | ±2.5% of reading |
| Flow Stability | ±2.5% over time |
| Temperature Control Range | 15–30 °C |
| Pre-Pressure Measurement | –35 to +35 kPa (±2.5% accuracy) |
| Barometric Pressure Range | 60–120 kPa (±0.5 kPa accuracy) |
| Operating Ambient | –20 to +45 °C, 0–95% RH |
| Battery Runtime | >15 h (7.4 V / 10 Ah Li-ion) |
| Noise Level | <55 dB(A) |
| Power Consumption | <50 W |
| Dimensions | 255 × 163 × 240 mm |
| Weight | ~2.5 kg |
| Compliance | HJ/T 375–2007, JJG 956–2013 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-6022 |
| Price Range | USD 140–1,150 (FOB) |
| Measurement Principle | Laser Light Scattering |
| Safety Classification | Non-Explosive Atmosphere Rated |
| Measurement Range | 0–50 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±15% FS |
| Repeatability | ≤10% CV |
| Detectable Fractions | PM₂.₅, PM₁₀, TSP |
| Sampling Method | Pump-Aspirated |
| Flow Rate | 1.1 L/min |
| Display | LED |
| Power Supply | Internal Rechargeable Li-ion Battery (16.8 V charger included), 10 h continuous operation |
| Operating Temperature | −20 °C to 50 °C |
| Storage Humidity | ≤85% RH (non-condensing) |
| Dimensions | 178 × 94 × 150 mm |
| Weight | 1.0 kg |
| Data Interfaces | RS-232, USB, optional analog output (4–20 mA), optional wireless module |
| Data Storage Capacity | 1,800 records (standard), 30 records for occupational hygiene logging |
| Alarm Outputs | Audible alert + configurable digital switch output (optional) |
| Calibration | Dynamic auto-zero compensation |
| Compliance | JJG 846–2015 (China National Verification Regulation for Dust Concentration Meters) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2051 |
| Sampling Flow Rate | 0.2–1.5 L/min |
| Flow Accuracy | ±0.1% (full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | >15 h |
| Operating Temperature | −20 to +45 °C |
| Operating Humidity | 0–95% RH |
| Dimensions | 240 × 180 × 240 mm |
| Weight | ~2 kg |
| Compliance | HJ/T 47–1999 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | AL-4 |
| Instrument Type | Portable |
| Configuration | Multi-Gas VOC Detector |
| Detection Range | Selectable (0–50, 100, 200, 1000, 2000, or 10,000 ppm) |
| Resolution | 0.01 ppm |
| Accuracy | ±3% FS |
| Repeatability | ≤±2% |
| Linearity | ≤±2% |
| Response Time (T90) | ≤20 s |
| Sampling Method | Integrated Active Pump |
| Flow Rate | 500 mL/min |
| Display | 2.3-inch High-Resolution Color LCD |
| Interface Languages | English & Chinese |
| Data Storage | 100,000 records |
| Communication | USB port (RS232 optional) |
| Battery | 4500 mAh Li-Polymer rechargeable |
| Charging | Micro-USB |
| Alarm | Triple-mode (audible, visual, vibration) |
| Ingress Protection | IP65 |
| Explosion Protection | Ex ia II CT6 |
| Operating Temperature | −40 °C to +70 °C |
| Operating Humidity | 0–99% RH (non-condensing) |
| Dimensions | 165 × 75 × 30 mm |
| Weight | 0.3 kg |
| Standard Accessories | Host unit, USB charger, hydrophobic dust filter, aluminum carrying case, certificate of conformity, warranty card, user manual |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-3019A |
| Instrument Type | Portable |
| Detection Target | Single-component CO₂ |
| Measurement Range | 0–0.500% (configurable to 0–1.000%) |
| Resolution | 0.001% |
| Repeatability | ≤1% FS |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3h |
| Response Time (t₀–t₉₀) | ≤15 s |
| Flow Rate | 0.5–1.0 L/min |
| Temperature Error | ≤±2% FS/10°C (10–45°C) |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Warm-up Time | ≤10 min |
| Data Storage Capacity | Up to 10,000 records |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 235 × 160 × 145 mm |
| Weight | ≤2 kg |
| Compliance | GB/T 18204.2–2014, GBZ/T 300.37–2017, HJ 870–2017, JJG 635–2011 |
| Calibration Traceability | Certified to Class II accuracy per Chinese national metrological standards |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HA-6012D |
| Flow Range | 5–30 L/min |
| Maximum Negative Pressure | >3000 Pa |
| Sampling Modes | Respirable & Total Dust (dual-head configuration) |
| Battery Runtime | >180 min (typical) |
| Flow Stability | ≤5% |
| Noise Level | <65 dB(A) |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤85% RH |
| Ambient Pressure Range | 80–110 kPa |
| Weight | ~2.0 kg |
| Dimensions | 200 × 75 × 140 mm |
| Explosion Protection | Ex ib I Mb (IEC 60079-0, IEC 60079-11) |
| Timer Range | 00:00 to 99:59 h:min (user-selectable) |
| Flow Accuracy | ±5% FS |
| Compliance | MT162–1995, Q/FY-02–2005, GB 3836.1–2010 / GB 3836.4–2010, CPA Type Approval Certificate Available |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-6023 |
| Measurement Principle | Laser Light Scattering |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0–300,000 µg/m³ (PM₂.₅/PM₁₀/TSP) |
| Resolution | 1 µg/m³ |
| Accuracy | ±10 µg/m³ (≤100 µg/m³), ±10% (100–300,000 µg/m³) |
| Flow Rate | 1.0 L/min ±2.5% |
| Display | 4.3″ capacitive touchscreen |
| Data Storage | ≥500 records (general mode), ≥50 records (occupational hygiene mode) |
| Battery | 7.4 V / 7.8 Ah Li-ion, >8 h continuous operation |
| Dimensions | 210 × 100 × 190 mm |
| Weight | ~1.8 kg |
| Communication | USB, optional Bluetooth, RS232/RS485, 4G module |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AL-HW6010 |
| Instrument Type | Portable |
| Detection Target | Multi-component Gaseous Analyte |
| Minimum Detectable Range | ppm-level |
| Repeatability | ≤1% F.S. |
| Resolution | CO: 0.1 ppm |
| CO₂ | 0.001% |
| Response Time | CO: t₀–t₉₀ ≤45 s |
| CO₂ | t₀–t₉₀ ≤15 s |
| Zero Drift | ≤±2% F.S./h |
| Span Drift | ≤±2% F.S./3 h |
| Linearity Error | ≤±2% F.S. |
| Brand | Ailun |
|---|---|
| Model | AL-3020 |
| Type | Portable Gas Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–50.0 ppm CO / 0–0.500% CO₂ (or 0–200.0 ppm CO / 0–1.000% CO₂) |
| Resolution | 0.1 ppm CO / 0.001% CO₂ |
| Repeatability | ≤1% F.S. |
| Zero Drift | ≤±2% F.S./h |
| Span Drift | ≤±2% F.S./3h |
| Linearity Error | ≤±2% F.S. |
| Response Time (t₀–t₉₀) | ≤45 s (CO), ≤15 s (CO₂) |
| Warm-up Time | ≤30 min |
| Flow Rate | 0.5–2.0 L/min |
| Data Storage | Up to 10,000 records |
| Interface | RS232 with dedicated data transfer software |
| Operating Temperature | 10–45 °C |
| Temperature-Induced Error | ≤±2% F.S./10 °C |
| CO Interference Tolerance | ≤±0.3% F.S. at 1250 mg/m³ CO |
| Display Units | ppm, mg/m³, % (auto-convertible) |
| Environmental Monitoring | Integrated temperature & humidity sensing |
| Sampling Method | Built-in diaphragm pump (up to 30 m sampling distance) |
| Compliance | GB/T 18204.2–2014, GB/T 9801–1988, JJG 635–2011, HJ 965–2018, GBZ/T 300.37–2017 |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-3015F |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gases | Carbon Monoxide (CO) and Carbon Dioxide (CO₂) |
| Measurement Ranges | CO: 0.0–50 ppm (extendable to 100 ppm / 200 ppm) |
| CO₂ | 0.0–0.500% vol or 0.0–1.000% vol |
| Resolution | CO: 0.1 ppm |
| CO₂ | 0.001% vol |
| Repeatability | ≤1% FS |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±1% FS/h |
| Span Drift | ≤±2% FS/3h |
| Response Time (T₉₀) | CO ≤60 s, CO₂ <45 s |
| Preheat Time | 30 min |
| Flow Rate | 0.5–2.0 L/min |
| Power Supply | AC 220 V ±10% or internal rechargeable battery |
| Battery Life | 4 h |
| Dimensions | 282 mm × 213 mm × 108 mm |
| Weight | 4.2 kg |
| Data Storage | Internal memory (5,000 records) + microSD card support |
| Communication | RS485, Wi-Fi (AP mode), Bluetooth-enabled mobile app integration |
| Environmental Operating Range | 5–40 °C, 10–95% RH |
| Compliance | GBZ/T 300.37–2017, GB/T 9801–1988, JJG 635–2011, Class II metrological accuracy per Chinese national standards |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | HB6080 |
| Detection Principle | Electrochemical Sensor Technology |
| Form Factor | Portable |
| Response Time | ≤30 s |
| Target Gases | SO₂, NO, CO |
| Repeatability | ±2% FS (typical for electrochemical sensors) |
| Compliance | Meets Chinese national standards for toxic and indoor air quality gas detection (e.g., HJ 693–2014, GB/T 18204.2–2014) |
| Sensor Interface | Auto-recognizing digital sensor module |
| Enclosure Rating | IP54 (dust- and splash-resistant) |
| Power Supply | Rechargeable Li-ion battery (≥10 h continuous operation) |
| Data Output | RS232/USB interface, optional Bluetooth 5.0 |
| Operating Temperature | –10 °C to +50 °C |
| Storage Temperature | –20 °C to +60 °C |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6040 |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | In-situ UV Absorption Flue Gas Analyzer |
| Measured Gases | SO₂, NO, NO₂, CO, CS₂, H₂S, NH₃ |
| Flow Accuracy | ≤ ±2 % FS |
| Sampling Flow Rate | 0.5–1.5 L/min |
| Flue Gas Velocity Range | 5–30 m/s |
| Moisture Content Measurement Range | 0.1–40.0 % v/v |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | AL-HB6200 |
| Pricing | Upon Request |
| Brand | Ailun (Qingdao Ailun) |
|---|---|
| Origin | Shandong, China |
| Model | GIC-YC9000 |
| Instrument Type | Online Aerosol and Gaseous Ion Analyzer |
| Liquid Sampling Resolution | 0.01 mL |
| Gas Absorption Efficiency | ≥98.2% |
| Aerosol Collection Efficiency | ≥99.1% |
| Measured Species | F⁻, Cl⁻, NO₃⁻, NO₂⁻, SO₄²⁻, Na⁺, NH₄⁺, K⁺, Mg²⁺, Ca²⁺, HF, HCl, HNO₂, HNO₃, SO₂, NH₃ |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-3018A |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gas | Carbon Monoxide (CO) |
| Measurement Range | 0.0–50 ppm (standard), optional 200/1000 ppm ranges |
| Resolution | 0.1 ppm |
| Linearity Error | ≤ ±2% FS |
| Repeatability | ≤ 1.0% |
| Zero Drift | ≤ ±2% FS / 3 h |
| Response Time (t₀–t₉₀) | ≤ 45 s |
| Warm-up Time | 30 min |
| Flow Rate | 0.5–2.0 L/min |
| Temperature Range | −20 to +60 °C |
| Relative Humidity Range | 10–95% RH |
| Data Storage Capacity | 10,000 measurement records |
| Display Units | ppm and mg/m³ (auto-convertible) |
| Compliance | GB/T 9801–1988, GB/T 18204.23–2000, JJG 635–2011, HJ 965–2018, GB/T 18204.2–2014, GBZ/T 300.37–2017 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HA6012 |
| Instrument Type | 24-Hour Constant-Temperature Constant-Flow Gas Sampler |
| Instrument Architecture | Dual-Channel Parallel Gas Sampler |
| Flow Range | 100 L/min |
| Maximum Vacuum Pressure | 60–130 kPa |
| Flow Stability | ±2% |
| Flowmeter Accuracy | ±2% |
| Service Life Under Max Flow & Backpressure | >20,000 h |
| Adjustable Sampling Duration | 1 min to 99 h 59 min |