OriginShandong, China
ModelAL-3019A
Instrument TypePortable
Detection TargetSingle-component CO₂
Measurement Range0–0.500% (configurable to 0–1.000%)
Resolution0.001%
Repeatability≤1% FS
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3h
Response Time (t₀–t₉₀)≤15 s
Flow Rate0.5–1.0 L/min
Temperature Error≤±2% FS/10°C (10–45°C)
CO Interference≤±0.3% FS at 1250 mg/m³ CO
Warm-up Time≤10 min
Data Storage CapacityUp to 10,000 records
Power SupplyAC 220 V (±10%) or rechargeable Li-ion battery
Dimensions235 × 160 × 145 mm
Weight≤2 kg
ComplianceGB/T 18204.2–2014, GBZ/T 300.37–2017, HJ 870–2017, JJG 635–2011
Calibration TraceabilityCertified to Class II accuracy per Chinese national metrological standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAL-HW6010
Instrument TypePortable
Detection TargetMulti-component Gaseous Analyte
Minimum Detectable Rangeppm-level
Repeatability≤1% F.S.
ResolutionCO: 0.1 ppm
CO₂0.001%
Response TimeCO: t₀–t₉₀ ≤45 s
CO₂t₀–t₉₀ ≤15 s
Zero Drift≤±2% F.S./h
Span Drift≤±2% F.S./3 h
Linearity Error≤±2% F.S.
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
ModelAL-3020
TypePortable Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurement Range0–50.0 ppm CO / 0–0.500% CO₂ (or 0–200.0 ppm CO / 0–1.000% CO₂)
Resolution0.1 ppm CO / 0.001% CO₂
Repeatability≤1% F.S.
Zero Drift≤±2% F.S./h
Span Drift≤±2% F.S./3h
Linearity Error≤±2% F.S.
Response Time (t₀–t₉₀)≤45 s (CO), ≤15 s (CO₂)
Warm-up Time≤30 min
Flow Rate0.5–2.0 L/min
Data StorageUp to 10,000 records
InterfaceRS232 with dedicated data transfer software
Operating Temperature10–45 °C
Temperature-Induced Error≤±2% F.S./10 °C
CO Interference Tolerance≤±0.3% F.S. at 1250 mg/m³ CO
Display Unitsppm, mg/m³, % (auto-convertible)
Environmental MonitoringIntegrated temperature & humidity sensing
Sampling MethodBuilt-in diaphragm pump (up to 30 m sampling distance)
ComplianceGB/T 18204.2–2014, GB/T 9801–1988, JJG 635–2011, HJ 965–2018, GBZ/T 300.37–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-3015F
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Target GasesCarbon Monoxide (CO) and Carbon Dioxide (CO₂)
Measurement RangesCO: 0.0–50 ppm (extendable to 100 ppm / 200 ppm)
CO₂0.0–0.500% vol or 0.0–1.000% vol
ResolutionCO: 0.1 ppm
CO₂0.001% vol
Repeatability≤1% FS
Linearity Error≤±2% FS
Zero Drift≤±1% FS/h
Span Drift≤±2% FS/3h
Response Time (T₉₀)CO ≤60 s, CO₂ <45 s
Preheat Time30 min
Flow Rate0.5–2.0 L/min
Power SupplyAC 220 V ±10% or internal rechargeable battery
Battery Life4 h
Dimensions282 mm × 213 mm × 108 mm
Weight4.2 kg
Data StorageInternal memory (5,000 records) + microSD card support
CommunicationRS485, Wi-Fi (AP mode), Bluetooth-enabled mobile app integration
Environmental Operating Range5–40 °C, 10–95% RH
ComplianceGBZ/T 300.37–2017, GB/T 9801–1988, JJG 635–2011, Class II metrological accuracy per Chinese national standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAilun
OriginShandong, China
ModelAL-3018A
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Target GasCarbon Monoxide (CO)
Measurement Range0.0–50 ppm (standard), optional 200/1000 ppm ranges
Resolution0.1 ppm
Linearity Error≤ ±2% FS
Repeatability≤ 1.0%
Zero Drift≤ ±2% FS / 3 h
Response Time (t₀–t₉₀)≤ 45 s
Warm-up Time30 min
Flow Rate0.5–2.0 L/min
Temperature Range−20 to +60 °C
Relative Humidity Range10–95% RH
Data Storage Capacity10,000 measurement records
Display Unitsppm and mg/m³ (auto-convertible)
ComplianceGB/T 9801–1988, GB/T 18204.23–2000, JJG 635–2011, HJ 965–2018, GB/T 18204.2–2014, GBZ/T 300.37–2017