Empowering Scientific Discovery

Qingdao Environmental Control Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
ModelGHK-4100G
TypePortable Multi-Component Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) for CO and CO₂
Measurement Range (typical)CO: 0–1000 ppm
CO₂0–5000 ppm
O₂0–25% vol
Accuracy±2% FS (CO, CO₂)
Response Time (T90)<30 s
Operating Temperature0–40 °C
Relative Humidity0–95% RH (non-condensing)
Flow Rate0.5–2.0 L/min
Data Storage>8000 records
Battery Life>4 h (Li-ion, rechargeable)
CommunicationUSB, RS232, optional Bluetooth
ComplianceJJG635–2011, GBZ/T 300.37–2017, GB/T 18204.2–2014, GB 8982–2009, YY 1468–2016
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasesMulti-component (CO₂, CO, CH₄, C₃H₈, C₂H₄, C₂H₅OH, C₂H₄O, CH₃Br, SF₆)
Repeatability±1% of Full Scale (F.S.)
Resolution0.01% vol (for CO₂)
Response Time (T₉₀)<20 s
Flow ControlElectronic mass flow meter with closed-loop regulation
Power SupplyRechargeable high-energy Li-ion battery (≥8 h continuous operation)
ComplianceGB 12358–2006, HJ/T 44–1999, JJG 635–2011, GB/T 19666–2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
ModelGHK-4100W
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Gas TargetsCO, CO₂, O₂ (simultaneous)
PortabilityHandheld, Battery-Powered
Measurement Range (Configurable)CO: 0–1000 ppm / 0–5000 ppm
CO₂0–2000 ppm / 0–100 % vol
O₂0–25 % vol
Accuracy±2 % FS (typical, per gas channel)
Response Time (T₉₀)<30 s
Operating Temperature−10 to +50 °C
Relative Humidity Range0–95 % RH (non-condensing)
Data Storage Capacity≥5000 measurement records
Sampling Flow Rate0.5–2.0 L/min (adjustable)
Power SupplyRechargeable Li-ion battery (≥4 h continuous operation)
Communication InterfacesUSB, RS232, optional Bluetooth printing module
AlarmConfigurable audible & visual alarms with user-defined thresholds
Unitsppm, mg/m³, % vol (switchable)
Environmental CompensationIntegrated temperature & humidity sensors with real-time compensation algorithm
Compliance StandardsJJG635-2011, HJ870-2017, HJ/T44-1999, GBZ/T300.37-2017, GB/T18204.2-2014, GB/T18204.23-2000, GB/T18204.24-2000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasesMulti-component (CO₂, CH₄, C₃H₈, C₂H₄, C₂H₅OH, C₂H₄O, CH₃Br, SF₆)
Resolution0.01% vol
Response Time<20 s
Power SupplyRechargeable High-Capacity Lithium Battery (≥8 h continuous operation)
Flow ControlElectronic Mass Flow Meter with Closed-Loop Regulation
AlarmConfigurable Dual-Level Audible/Visual Alarm
Data OutputReal-time ppm, % vol, mg/m³ units
OptionalBluetooth Thermal Printer Module
ComplianceJJG 635–2011, HJ/T 44–1999, GB 12358–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Instrument TypePortable
Detection TargetMulti-component Gases
Minimum RangeCustomizable
Repeatability±1% F.S.
Resolution0.01 ppm (CO₂) / 1 ppm (CO)
Response Time<15 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
ModelGHK-4100
TypePortable NDIR Gas Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR)
Measurable GasesCO, CO₂, CH₄, C₃H₈, C₂H₄, C₂H₅OH, C₂H₄O, CH₃Br, SF₆
Repeatability±1% of Full Scale
Operating Flow Rate0.5–2.0 L/min
Data Storage Capacity>8,000 records
Power SupplyRechargeable Li-ion battery (≥4 h continuous operation)
Communication InterfacesUSB, RS232, Bluetooth (optional)
DisplayColor touchscreen with dual-mode output (digital + analog-style gauge)
AlarmConfigurable audible/visual alarm with user-defined thresholds
Unitsppm, mg/m³, % (switchable)
Environmental CompensationIntegrated temperature & humidity sensors with real-time correction algorithm
CalibrationDual zeroing mode (catalytic converter or N₂ gas)