| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2000L |
| Instrument Category | Flue Gas Sampling System |
| Target Analyte | Hydrogen Chloride (HCl) |
| Compliance Standards | HJ 547–2017, HJ 548–2016, HJ 549–2016 |
| Sampling Configuration | Heated Probe + PTFE Filter Cartridge + Temperature-Controlled Absorption Bottles + Condensation Management Unit |
| Heating Range | 0–60 °C |
| Temperature Control Accuracy | ±2 °C |
| Absorption Bottle Capacity | 6 positions (including blank and sample) |
| Filter Medium | Cellulose Acetate Microporous Membrane |
| Tubing Material | Fluorosilicone Insulated Tubing with Anti-Adsorption Lining |
| Internal Probe Liner | PTFE (non-adsorptive) |
| Filter Housing & Support Mesh | PTFE-coated |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2100 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sampled Gases | O₂, SO₂, NO, NO₂, CO, H₂S, CO₂ (configurable) |
| Sampling Flow Rate | 0–100 L/min |
| Flow Accuracy | ≤ ±2.5% FS |
| Flue Gas Velocity Range | 1–45 m/s |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GHK-2000Q |
| Instrument Category | Flue Gas Sampling System |
| Target Analytes | Aldehydes and Ketones (e.g., formaldehyde, acetaldehyde, acetone, propionaldehyde) |
| Operating Temperature Range | −30 °C to +50 °C |
| Sampling Gun Heating Range | 0–200 °C |
| Dual-Channel Flow Control | Independent constant-flow sampling (±10% tolerance |
| Data Storage | 200 entries with time-stamped flow, temperature, pressure, and volume data |
| Power Supply | Integrated high-capacity lithium battery powering host, heated box, trace-heated line, and sampling probe |
| Compliance | GB/T 16157–1996, HJ 1153–2020 |
| Key Features | Light-shielded isothermal sample preservation, anti-backflow desiccant bottle, real-time standard-volume correction (STP), ambient temperature & barometric pressure sensing, brushless diaphragm pump, IP-rated weather-resistant enclosure |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2900 |
| Instrument Type | Flue Gas Sampling Preconditioner |
| Dehumidification Technology | Integrated Peltier Cooling + Nafion® Membrane Permeation |
| Filtration | Dual-stage particulate filtration (≤0.3 µm) |
| Temperature Control | PID-regulated heating & cooling (±0.8 °C stability) |
| Condensate Management | Programmable peristaltic pump drainage |
| Sample Line | Fully heated sampling probe and PTFE-lined transport tubing |
| Real-time Monitoring | Displayed dew point temperature and absolute humidity (g/m³) |
| Origin | Qingdao, Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3012H |
| Pricing | Available Upon Request |
| Sampling Principle | Isokinetic Sampling via Pitot Tube + Gravimetric Collection |
| Gas Detection Method | Potentiostatic Electrolysis |
| Operating Power | AC 220 V ±10%, 50 Hz or DC 12 V |
| Dimensions | 450 × 168 × 410 mm |
| Weight | ~10.0 kg |
| Noise Level | <65 dB(A) |
| Power Consumption | <180 W |
| Data Storage Capacity | >100,000 measurement records |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK1052 |
| Instrument Type | Flue Gas Sampling System |
| Target Analytes | SO₂, NOₓ, and other combustion gases |
| Flow Accuracy | ±1% FS |
| Sampling Flow Rate | 1.5 L/min |
| Flue Gas Throughput Capacity | >2 L/min |
| Moisture Removal Efficiency | ≤4 °C dew point output (at 25 °C ambient, 1 L/min gas flow) |
| Heating Gun Setpoint Range | 20–120 °C (adjustable, 0.1 °C resolution, ±2 °C accuracy) |
| Refrigeration Setpoint Range | 0–10 °C (adjustable, 0.1 °C resolution, ±2 °C accuracy) |
| Inlet Gas Temperature Limit | ≤150 °C |
| Compressor Cooling Capacity | 470 W |
| Heating Time (20→120 °C) | ≤6 min |
| Cooling Time (25→2 °C) | ≤6 min |
| Sample Probe Length | 1 m (customizable) |
| Heated Tubing Length | 2 m (customizable) |
| Probe Material | 304 stainless steel |
| Filtration | Removable 0.1 µm PTFE filter |
| Gas Path Material | Entirely PTFE (no metal contact) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤300 W |
| Operating Ambient Temperature | −20 to +55 °C |
| Host Dimensions (L×W×H) | 32 × 21 × 20 cm |
| Host Weight | <6.5 kg |
| Noise Level | ≤55 dB(A) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GHK-2000 |
| Instrument Type | Flue Gas Sampler |
| Sample Type | Flue Gas |
| Sampling Flow Rate | 0.1–1.5 L/min |
| Flue Gas Velocity | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GHK-2200 |
| Instrument Type | Flue Gas Particulate Sampler |
| Flue Gas Velocity Range | 1–45 m/s |
| Measurement Principle | Beta-Ray Absorption Gravimetry |
| Regulatory Compliance | GB/T 16157–1996, HJ/T 397–2007, DB37/T 3785–2019 |
| Optional Modules | Integrated Humidity Sensor, Heated Filter Tape Transport System, Modular Pitot Tube, IoT Data Transmission Module, USB Mass Storage Export |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2300 |
| Instrument Type | Flue Gas Sampling and Analysis System |
| Sampling Flow Rate | 1.0 L/min |
| Flue Gas Velocity Range | 1–45 m/s |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Key Measured Gases | SO₂, NOₓ (NO/NO₂), CO₂, CO, H₂S, O₂, CH₄, N₂O |
| Integrated Humidity Sensor | Yes |
| Operating Temperature Range | –20 °C to 50 °C |
| Power Supply | DC 12–26 V / AC 80–260 V |
| Battery Runtime | >4 h (host + probe) |
| Data Storage | High-Capacity Internal Memory with USB Export |
| Connectivity | Bluetooth (printer), Optional IoT Module for Remote Transmission |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GHK-2901 |
| Instrument Type | Flue Gas Preconditioner |
| Sample Type | Flue Gas |
| Compliance Standard | HJ/T 47–1999 “Technical Specifications for Flue Gas Samplers” |
| Cooling Method | High-Power Compressor-Based Refrigeration |
| Minimum Refrigeration Temperature | –10 °C |
| Heating & Cooling Control | Dual-Screen PID Control |
| Sample Line Material | PTFE-Lined Tubing |
| Filtration | Dual-Stage — Sintered Metal + PTFE Membrane |
| Condensate Removal | External Peristaltic Pump with Visual Chamber |
| Electrical Safety | Low-Voltage DC for Heating/Refrigeration Circuits |
| Connection Interface | Quick-Connect Fittings for Gas and Power |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GHK-2000E |
| Instrument Category | Flue Gas and Particulate Sampler |
| Sampling Flow Rate | 5–60 L/min |
| Moisture Content Range | 0–60% |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | GHK-2000W |
| Instrument Type | Flue Gas VOC Sampler |
| Compliance Standards | HJ 734–2014, HJ 644–2013, HJ 583–2010, HJ 584–2010, HJ 801–2016 |
| Sampling Method | Solid-phase Adsorption with Thermal Desorption |
| Cooling Range | 0–5 °C (adsorbent tube compartment) |
| Filtration | Integrated 2 µm sintered metal filter |
| Heating Control | PID-regulated, ±2 °C accuracy |
| Data Storage | Up to 1000 sampling records |