Empowering Scientific Discovery

Qingdao Environmental Control Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGHK-2000L
Instrument CategoryFlue Gas Sampling System
Target AnalyteHydrogen Chloride (HCl)
Compliance StandardsHJ 547–2017, HJ 548–2016, HJ 549–2016
Sampling ConfigurationHeated Probe + PTFE Filter Cartridge + Temperature-Controlled Absorption Bottles + Condensation Management Unit
Heating Range0–60 °C
Temperature Control Accuracy±2 °C
Absorption Bottle Capacity6 positions (including blank and sample)
Filter MediumCellulose Acetate Microporous Membrane
Tubing MaterialFluorosilicone Insulated Tubing with Anti-Adsorption Lining
Internal Probe LinerPTFE (non-adsorptive)
Filter Housing & Support MeshPTFE-coated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelGHK-2100
Instrument TypeFlue Gas and Particulate Sampler
Sampled GasesO₂, SO₂, NO, NO₂, CO, H₂S, CO₂ (configurable)
Sampling Flow Rate0–100 L/min
Flow Accuracy≤ ±2.5% FS
Flue Gas Velocity Range1–45 m/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelGHK-2000Q
Instrument CategoryFlue Gas Sampling System
Target AnalytesAldehydes and Ketones (e.g., formaldehyde, acetaldehyde, acetone, propionaldehyde)
Operating Temperature Range−30 °C to +50 °C
Sampling Gun Heating Range0–200 °C
Dual-Channel Flow ControlIndependent constant-flow sampling (±10% tolerance
Data Storage200 entries with time-stamped flow, temperature, pressure, and volume data
Power SupplyIntegrated high-capacity lithium battery powering host, heated box, trace-heated line, and sampling probe
ComplianceGB/T 16157–1996, HJ 1153–2020
Key FeaturesLight-shielded isothermal sample preservation, anti-backflow desiccant bottle, real-time standard-volume correction (STP), ambient temperature & barometric pressure sensing, brushless diaphragm pump, IP-rated weather-resistant enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGHK-2900
Instrument TypeFlue Gas Sampling Preconditioner
Dehumidification TechnologyIntegrated Peltier Cooling + Nafion® Membrane Permeation
FiltrationDual-stage particulate filtration (≤0.3 µm)
Temperature ControlPID-regulated heating & cooling (±0.8 °C stability)
Condensate ManagementProgrammable peristaltic pump drainage
Sample LineFully heated sampling probe and PTFE-lined transport tubing
Real-time MonitoringDisplayed dew point temperature and absolute humidity (g/m³)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginQingdao, Shandong, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
Model3012H
PricingAvailable Upon Request
Sampling PrincipleIsokinetic Sampling via Pitot Tube + Gravimetric Collection
Gas Detection MethodPotentiostatic Electrolysis
Operating PowerAC 220 V ±10%, 50 Hz or DC 12 V
Dimensions450 × 168 × 410 mm
Weight~10.0 kg
Noise Level<65 dB(A)
Power Consumption<180 W
Data Storage Capacity>100,000 measurement records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGHK1052
Instrument TypeFlue Gas Sampling System
Target AnalytesSO₂, NOₓ, and other combustion gases
Flow Accuracy±1% FS
Sampling Flow Rate1.5 L/min
Flue Gas Throughput Capacity>2 L/min
Moisture Removal Efficiency≤4 °C dew point output (at 25 °C ambient, 1 L/min gas flow)
Heating Gun Setpoint Range20–120 °C (adjustable, 0.1 °C resolution, ±2 °C accuracy)
Refrigeration Setpoint Range0–10 °C (adjustable, 0.1 °C resolution, ±2 °C accuracy)
Inlet Gas Temperature Limit≤150 °C
Compressor Cooling Capacity470 W
Heating Time (20→120 °C)≤6 min
Cooling Time (25→2 °C)≤6 min
Sample Probe Length1 m (customizable)
Heated Tubing Length2 m (customizable)
Probe Material304 stainless steel
FiltrationRemovable 0.1 µm PTFE filter
Gas Path MaterialEntirely PTFE (no metal contact)
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption≤300 W
Operating Ambient Temperature−20 to +55 °C
Host Dimensions (L×W×H)32 × 21 × 20 cm
Host Weight<6.5 kg
Noise Level≤55 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelGHK-2000
Instrument TypeFlue Gas Sampler
Sample TypeFlue Gas
Sampling Flow Rate0.1–1.5 L/min
Flue Gas Velocity1–45 m/s
Moisture Content Range0–60%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Regional ClassificationDomestic (China)
ModelGHK-2200
Instrument TypeFlue Gas Particulate Sampler
Flue Gas Velocity Range1–45 m/s
Measurement PrincipleBeta-Ray Absorption Gravimetry
Regulatory ComplianceGB/T 16157–1996, HJ/T 397–2007, DB37/T 3785–2019
Optional ModulesIntegrated Humidity Sensor, Heated Filter Tape Transport System, Modular Pitot Tube, IoT Data Transmission Module, USB Mass Storage Export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGHK-2300
Instrument TypeFlue Gas Sampling and Analysis System
Sampling Flow Rate1.0 L/min
Flue Gas Velocity Range1–45 m/s
Measurement PrincipleNon-Dispersive Infrared (NDIR) Absorption
Key Measured GasesSO₂, NOₓ (NO/NO₂), CO₂, CO, H₂S, O₂, CH₄, N₂O
Integrated Humidity SensorYes
Operating Temperature Range–20 °C to 50 °C
Power SupplyDC 12–26 V / AC 80–260 V
Battery Runtime>4 h (host + probe)
Data StorageHigh-Capacity Internal Memory with USB Export
ConnectivityBluetooth (printer), Optional IoT Module for Remote Transmission
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelGHK-2901
Instrument TypeFlue Gas Preconditioner
Sample TypeFlue Gas
Compliance StandardHJ/T 47–1999 “Technical Specifications for Flue Gas Samplers”
Cooling MethodHigh-Power Compressor-Based Refrigeration
Minimum Refrigeration Temperature–10 °C
Heating & Cooling ControlDual-Screen PID Control
Sample Line MaterialPTFE-Lined Tubing
FiltrationDual-Stage — Sintered Metal + PTFE Membrane
Condensate RemovalExternal Peristaltic Pump with Visual Chamber
Electrical SafetyLow-Voltage DC for Heating/Refrigeration Circuits
Connection InterfaceQuick-Connect Fittings for Gas and Power
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelGHK-2000E
Instrument CategoryFlue Gas and Particulate Sampler
Sampling Flow Rate5–60 L/min
Moisture Content Range0–60%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHUANKONG
OriginShandong, China
Manufacturer TypeOEM/ODM Producer
Country of OriginChina
ModelGHK-2000W
Instrument TypeFlue Gas VOC Sampler
Compliance StandardsHJ 734–2014, HJ 644–2013, HJ 583–2010, HJ 584–2010, HJ 801–2016
Sampling MethodSolid-phase Adsorption with Thermal Desorption
Cooling Range0–5 °C (adsorbent tube compartment)
FiltrationIntegrated 2 µm sintered metal filter
Heating ControlPID-regulated, ±2 °C accuracy
Data StorageUp to 1000 sampling records
OptionalBluetooth thermal printer module
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0